Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.9 LAccepted-AOC HOUSE NO 95 STREET NO 08 JAWAHAR COLONY NEAR LAXMI DAIRY FARIDABAD SECTOR 22 HARYANA 121005 | FARIDABAD | HARYANA | 121005 | L1 | Accepted-AOC Being L1 Bidder | |
| 2 | L2₹33.9 L+₹5.9 L (21.2%)Rejected-AOC B 87 SHAM NAGAR KHAYALA ROAD NEW DELHI 110018 | NEW DELHI | NEW DELHI | DELHI | 110018 | L2 | Rejected-AOC Not L1 Bidder | |
| 3 | L3₹34.1 L+₹6.2 L (22.2%)Rejected-AOC | L3 | Rejected-AOC Not L1 Bidder | |
| 4 | L4₹36.2 L+₹8.2 L (29.4%)Rejected-AOC A 303 VEENA CGHS LTD PLOT NO 5D SECTOR 22 DWARKA NEW DELHI 110077 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110077 | L4 | Rejected-AOC Not L1 Bidder | |
| 5 | L5₹37.3 L+₹9.4 L (33.6%)Rejected-AOC | L5 | Rejected-AOC Not L1 Bidder |
Tender Value
₹44 L
EMD Value
₹88,000
Closing Date
20 Apr 2024, 6:00 pmClosed
GE (U)(W/S) DELHI CANTT
GE (U)(W/S) DELHI CANTT-110010
REPAIR/REPLACEMENT/IMPROVEMENT OF LT ELECTRICAL PANELS INCLUDING STARTER AND OTHER ACCESSORIES AND STANDBY DG SETS AT VARIOUS WATER SUPPLY INSTALLATIONS AND CONNECTED WORKS IN THE AREA OF AGE (U) WATER SUPPLY NO-III UNDER GE (U) WATER SUPPLY
2024_MES_647509_1
GE/WS/IFA-168/Token 75 OF 2023-24
Open Tender
Civil Works
Item Rate
180 days
GE (U)(W/S) DELHI CANTT
AS PER NIT AND TENDER DOCUMENTS
6 documents required · 6 mandatory
₹500
GE(U)(W/S) DELHI CANTT
₹88,000
3 Sept 2024
23 Mar 2024
22 Apr 2024
23 Mar 2024
20 Apr 2024
7 Apr 2024
Amount
M/L for maintenance and servicing of following standby DG Set of any capacity complete by replacing the fuel filter, lubricating oil filter, check & clean air cleaner, change air cleaner elements, check coolant level & make up the same, drain the fuel filter & water separator, filling the starting batteries with electrolyte/distilled water to maintain the required specific gravity, replace the u/s brass connectors for batteries, cleaning of battery terminals & applying petroleum jelly to battery terminal posts & brass connectors, checking of exhaust leakage, governor, breathers etc, adjust/set the same for proper functioning of DG Set, checking of fuel, oil and water/ coolant level etc, adjusting and keeping the fan belts to the desired tension, tightening all the bolts and nuts to the required torque etc, cleaning the DG Set with accessories as prescribed by the manufacturer and test for satisfactory running of DG set for two hour minimum at connected load and record shall be made in respect of RPM , oil pressure , oil temprature , coolant temprature, voltage , frequancy, load current , battery charging , fuel consumption & noise level etc complete all as specidied and directed . Note:- (i) Major Spares parts/oil/coolent etc required for maintenance will be measured and paid seprately under relevant items. (ii) Minor spare parts i.e. nut bolt, washer, petroleum jelly deemed to be included in the quoted unit rate of this item(iii) DHPP will be issued by dept for testing only. (iv) Servicing to be carried out as per manufacturer’s specifications/ instructions (v) The work of maintenance , repair and overhauling shalll be carried out through respective authorized dealer whose certificate shall be produced to Engineer - in - charge. (vi) Proper record & test results of the same shall be maintained as directed. (vii) Work shall be carried out at site at different location
(a) 160 to 380 KVA DG set
(b) 100 to 125 KVA DG set
(c) 40 to 82.5 KVA DG set
Supply only of following items for DG Sets Capacity of 160 KVA to 380 KVA (Required under Sl item No. 1 (a) above)
(a) Air Filter
(b) Fuel Filter
(c) Lubricating oil filter
(d) Diesel return pipe
(e) Ignition switch for starting DG set with key.
(f) Diesel Fuel Hose pipe from diesel tank to fuel filter
(g) Fuel injector pipe from fuel pump to Injector
Supply only of following items for DG Sets Capacity of 100 to 125 KVA (Required under Sl item No. 1 (b) above)
(a) Air Filter
(b) Fuel Filter
(c) Lubricating oil filter
(d) Diesel return pipe
(e) Ignition switch for starting DG set with key.
(f) Diesel Fuel Hose pipe from diesel tank to fuel filter
(g) Fuel injector pipe from fuel pump to Injector
Supply only of following items for DG Sets Capacity of 40 to 82.5 KVA (Required under Sl item No. 1 (c) above)
(a) Air Filter
(b) Fuel Filter
(c) Lubricating oil filter
(d) Diesel return pipe
(e) Ignition switch for starting DG set with key.
(f) Diesel Fuel Hose pipe from diesel tank to fuel filter
(g) Fuel injector pipe from fuel pump to Injector
Supply only Fan Belt complete suitable for 160 to 380 KVA DG set compete all as specified and as directed.
Supply only Fan Belt complete suitable for 100 to 125 KVA DG set compete all as specified and as directed.
Supply only Fan Belt complete suitable for capacity 40 to 82.50 KVA DG set compete all as specified and as directed by Engr-in charge.
Supply only Belt for battery charging alternator complete suitable for 82.5 to 200 KVA DG set compete all as specified and as directed.
Supply only Belt for battery charging alternator complete suitable for capacity 40 to 70 KVA DG set compete all as specified and as directed by Engr-in charge.
Supply only Rubber Hose pipe set for water circuit with clamps complete suitable for 160 to 380 KVA DG set compete all as specified and as directed.
Supply only Rubber Hose pipe set for water circuit with clamps complete suitable for 100 to 125 KVA DG set compete all as specified and as directed.
Supply only Rubber Hose pipe set for water circuit with clamps complete suitable for 40 to 82.5 KVA DG set compete all as specified and as directed.
Supply only Engine oil, multi grade premium Genuine oil 20W/ 40 as per manufacturer recommendations in DG sets complete all as specified and as directed.
Supply and applying Petrolium Jelly (01 Kg plastic sealed container) complete all as specified and as directed.
Supply and fill distilled water for topping up in lead acid batteries complete all as specified and as directed.
Supply and fill electrolyte of suitable specific gravity for lead acid batteries in sealed container complete all as specified and as directed.
M & L for Battery leads of PVC insulated, multistranded, copper conductor of size 70 sqmm of 1.25 mtr long ach duly fixed with brass clamps, copper lugs suitable for DG set batteries installed at different locations complete including removal of extg unserviceable one complete all as specified and as directed.
M & L for Battery leads of PVC insulated, multistranded, copper conductor of size 25 sqmm of 1.25 mtr long ach duly fixed with brass clamps, copper lugs suitable for DG set batteries installed at different locations complete including removal of extg unserviceable one complete all as specified and as directed.
M & L for battery teriminal brass clamps including removal of extg unserviceable one compete all as specified and as directed by Engr-in charge.
M & L for disconnecting all electrical connections from DG set alternator of any capacity from base plate by opening nuts & bolts keeping aside the alternator for inspection and taking out to work shop for rewinding including testing & commissioning complete all as specified & directed.
Rewinding of alternator field coil with super enamelled copper winding wire of class 'F' insullation as per existing size and gauge including heating, varnishing and testing of following size complete all as specified and as directed.
(a) 50.00 KVA DG set to 82.50 KVA DG set
(b) 100 KVA DG set to 125 KVA DG set
(c) 160.00 KVA DG set to 200 KVA DG set
M & L for water temperature guage including sensor and cable complete as per sample including removal of extg unserviceable one complete all as specified and as directed.
M & L for dismantaling the radiator taking to work shop for overhauling & cleaning, de-scaling with acid, removal of leakage including soldering and welding, brazing as required and renewal of gaskets, nuts, bolts, mounting pads,hoses,clips, etc and refixing its original position for following capacities of DG set complete all as specified and directed.
(a) 40.00 KVA DG set to 82.5 KVA DG set
(b) 100.00 KVA DG set to 125.00 KVA DG set
(c) 160.00 KVA DG set to 200.00 KVA DG set
M & L for repair and calibration of FIP and injectors from authorised dealer for petty repairs to make the FIP functional as per standard calibration procedure and norms including replacement of minor spares, gasket etc for smooth functioning of FIP and refixing its original position including testing at site for following capacities of DG set complete all as specified and as directed. Note :- A certificate to the effect that the calibration and repairs has been carried out by the authorised dealer shall be submitted by the contractor to Engineer-in-charge.
(a) 40.00 KVA DG set to 82.5 KVA DG set
(b) 100.00 KVA DG set to 125.00 KVA DG set
(c) 160.00 KVA DG set to 380.00 KVA DG set
M & L for Repair/ overhauling of self starting system of DG set including replacement of carbon brushes, bearings, bushes, rewinding of armature and field coil etc and varnishing of capacity 24 volts with necessary connections incluing testing and commissioing complete all as specified and as directed.
M & L for Repair/ overhauling of self starting system of DG set including replacement of carbon brushes, bearings, bushes, rewinding of armature and field coil etc and varnishing of capacity 12 volts with necessary connections incluing testing and commissioing complete all as specified and as directed.
M & L for repairing of battery charging alternator engine mounted with replacement of any of the unserviceable part such as rectifier with voltage regulator, diode plate, corbon brushes of capacity 24 volts including testing and commissioing complete all as specified and as directed.
M & L for repairing of battery charging alternator engine mounted with replacement of any of the unserviceable part such as rectifier with voltage regulator, diode plate, corbon brushes of capacity 12 volts including testing and commissioing complete all as specified and as directed.
M & L for AVR (automatic voltage regulator) control unit assembly suitable for 40 KVA DG set to 82.5 KVA DG set including removal of extg unserviceable one compete all as specified and as directed by Engr-in charge.
M & L for AVR (automatic voltage regulator) control unit assembly suitable for 100 KVA DG set to 380 KVA DG set including removal of extg unserviceable one compete all as specified and as directed by Engr-in charge.
M & L for canopy hinges for auqastic doors with suitable bolts and nuts of DG set including removal of extg unserviceable one compete all as specified and as directed by Engr-in charge.
M & L for Anti vibration pads with suitable bolts and washers including removal of extg unserviceable one compete all as specified and as directed by Engr-in charge.
Supply only for digital type frequency meter 96 x 96 mm flush /square pattern including removal of extg unserviceable one compete all as specified and as directed by Engr-in charge.
Supply only for LED indicator lamps R, Y, B with holder 15 mm screw type including removal of extg unserviceable one compete all as specified and as directed by Engr-in charge.
Supply only for CT cast resin type of ratio 400/5 Amps of suitable VA burden including removal of extg unserviceable one compete all as specified and as directed by Engr-in charge.
Supply only for CT cast resin type of ratio 200/5 Amps of suitable VA burden including removal of extg unserviceable one compete all as specified and as directed by Engr-in charge.
S & F for CT cast resin type of ratio 100/5 Amps of suitable VA burden including removal of extg unserviceable one compete all as specified and as directed by Engr-in charge.
M & L for solenoid switch assembly 24 volts suitable for 100 KVA DG set to 380 KVA DG set including removal of extg unserviceable one compete all as specified and as directed by Engr-in charge.
M & L for solenoid switch assembly 12 volts suitable for 40 KVA DG set to 82.5 KVA DG set including removal of extg unserviceable one compete all as specified and as directed by Engr-in charge.
M & L for self starter assembly 12 volts complete suitable for 40KVA DG set to 83 KVA DG setincluding removal of extg unserviceable one complete all as specified and as directed. Make:- Lucas/ TVS
M & L for self starter assembly 24 volts complete suitable for 100 KVA DG set to 380 KVA DG set including removal of extg unserviceable one complete all as specified and as directed.
M & L for SMPS (system main power supply) type control unit assembly suitable for 12 volts battery charger for including removal of extg unserviceable one compete all as specified .
M & L for SMPS (system main power supply) type control unit assembly suitable for 24 volts battery charger for including removal of extg unserviceable one compete all as specified .
S & F for single phase preventer suitable for operation on 415 Volts 50 Hz AC supply including removal of extg unserviceable one compete all as specified and as directed by Engr-in charge.
S & F for battery low maintenance lead acid of capacity 12 volts 180 AH with initial charging including removal of extg unserviceable one and hand over to store yard compete all as specified and as directed by Engr-in charge.
S & F battery low maintenance lead acid of capacity 12 volts 150 AH with initial charging including removal of extg unserviceable one and hand over to store yard compete all as specified and as directed by Engr-in charge.
S & F battery low maintenance lead acid of capacity 12 volts 135 AH with initial charging including removal of extg unserviceable one and hand over to store yard compete all as specified and as directed by Engr-in charge.
M & L for welding MS pipe heavy duty 100 mm dia suitable for exhaust manifold of DG set with necessary scraping cutting to size as required and painting with two coats silver paint over a coat of redoxide primer including removal of extg unserviceable one compete all as specified and as directed.
S & F for solenoid valve suitable for following capacity of DG sets for smooth function of DG sets including removal of extg unserviceable one complete all specified and as directed
(a) 40.00 KVA DG set to 82.5 KVA DG set
(b) 100.00 KVA DG set to 125.00 KVA DG set
(c) 160.00 KVA DG set to 380.00 KVA DG set
M & L for Engine complete overhauling of DG set capacity 100/125 KVA of Kirloskar/ Crompton Greaves makes by opening the top cover complete including dismatlling the engine head, cylinder liner and piston assembly, crankshaft assembly, radiater fan belt and radiator fan, gear assembly complete removing of engine side for repair/ replacement of parts i.e gasket, washer, 'O' ring all types etc including grinding polishing of crank shaft , head repairing and overhauling valve seat cutting and replacing, valve tapping, head assemble and testing of DG set after necessary repair with and authorised dealer fix at site reassembling of DG set and testing on full load upto entire satisfaction of Engineer in Charge all as directed (Note :- 1. Measure spare parts will be measured and paid seperately under relevent items. 2. Quantities of Parts/ spare shall be assessed by department however when engine of DG Set opened for overhauling certain minor parts required to be replaced of worth of Rs 500/- will be provided by contractor for fully functional of engine without any extra claim of Govt. Quoted unit rate will deemed included for this aspects. 3. Contractor shall have no claim on account of variation of quantities of above items or non execution of above item(s) within permissible limits as per GCC IAFW-2249.)
(a) Supply only Piston assembly
(b) Supply only Piston ring set
(c) Supply only full engine gasket
(d) Supply only Main bearing set
(e) Supply only Main cylinder liner
(f) Supply only Main cylinder head copper sleeves
(g) Supply only Lock nut
(h) Supply only Big end bearing
(i) Supply only Timing Belt
(j) Supply only benjo bolt
(k) Supply only Timing belt tension adjuster
(l) Supply only inlet valve
(m) Supply only Exhaust Valve
(n) Supply only head gasket
(o) Supply only oil pump assembly
(p) Supply only Thrust washer
(q) Supply only Crank case gasket
(r) Supply only Head nozzle plug set
M & L for Engine complete overhauling of DG set capacity 50 to 82.50 KVA of Kirloskar/ Crompton Greaves makes by opening the top cover complete including dismatlling the engine head, cylinder liner and piston assembly, crankshaft assembly, radiater fan belt and radiator fan, gear assembly complete removing of engine side for repair/ replacement of parts i.e gasket, washer, 'O' ring all types etc including grinding polishing of crank shaft , head repairing and overhauling valve seat cutting and replacing, valve tapping, head assemble and testing of DG set after necessary repair with and authorised dealer fix at site reassembling of DG set and testing on full load upto entire satisfaction of Engineer in Charge all as directed (Note :- 1. Measure spare parts will be measured and paid seperately under relevent items. 2. Quantities of Parts/ spare shall be assessed by department however when engine of DG Set opened for overhauling certain minor parts required to be replaced of worth of Rs 500/- will be provided by contractor for fully functional of engine without any extra claim of Govt. Quoted unit rate will deemed included for this aspects. 3. Contractor shall have no claim on account of variation of quantities of above items or non execution of above item(s) within permissible limits as per GCC IAFW-2249.)
(a) Supply only Piston assembly
(b) Supply only Piston ring set
(c) Supply only full engine gasket
(d) Supply only Main bearing set
(e) Supply only Main cylinder liner
(f) Supply only Main cylinder head copper sleeves
(g) Supply only Lock nut
(h) Supply only Big end bearing
(i) Supply only Timing Belt
(j) Supply only benjo bolt
(k) Supply only Timing belt tension adjuster
(l) Supply only inlet valve
(m) Supply only Exhaust Valve
(n) Supply only head gasket
(o) Supply only oil pump assembly
(p) Supply only Thrust washer
(q) Supply only Crank case gasket
(r) Supply only Head nozzle plug set
S & F for pressure gauge 0 to 7 Kg/ sqcm along with sensor and cables for DG set including removal of extg unserviceable one complete all specified and as directed.
S & F for microprocessor based multifunction relay suitable for DG sets operation of any capacity and showing the various parameters such as volt, ampere, frequency, RPM etc complete as per site requirment including removal of extg unserviceable one complete all specified and as directed.
S & F for electric shock treatment coloured chart of English and Hindi languages of size 2' x 3' dully framing with second class hard wood bedding of 1" x 1" with front side PVC transperent sheet and back side with plywood cover of 3 mm thick including suitable hanging arrangement all as directed
M & L for chart/ diagram/ name plates/ details of DG sets made out of bakeite hylem sheet, ISI marked, 3 mm thick , cutting to shape /size including fixing of adhesive transperent filament of red/ blue colour including cutting of filament of letters/ figures/ diagrames/ details of suitable size/ type all as directed inclluding fixing to the wall by wooden screw and PVC hold fast etc complete all as directed and specified. Note :- Matter/ figure/ chart/ diagrames/ letter shall be given by the Engineer- in- Charge)
S & F connecting and testing MCCB in existing Panel of the following capacity, suitable for 415 volts, 50 Hz, with extended terminals type, connecting and testing complete including removal of exiting unsv all as specified and directed.
(a) 3 pole 63 Amps with thermal magnetic release breaking capacity 16 KA, Ics=100% Icu
(b) 3 pole 100 Amps with thermal magnetic release breaking capacity 25 KA, Ics=100% Icu
(c) 3 pole 125 Amps with thermal magnetic release breaking capacity 25 KA, Ics=100% Icu
(d) 3 pole 160 Amps with thermal magnetic release breaking capacity 25 KA, Ics=100% Icu
(e) 3 pole 200 Amps with thermal magnetic release breaking capacity 25 KA, Ics=100% Icu
(f) 4 pole 250 Amps with thermal magnetic release breaking capacity 36 KA, Ics=100% Icu
(g) 4 pole 350 Amps with thermal magnetic release breaking capacity 36 KA, Ics=100% Icu
S & F connecting and testing open execution on load change over in existing Panel of the following capacity, suitable for 415 volts, 50 Hz, with extended terminals type, interlocked to prevent opening when the Switch is in ON Position, connecting and testing complete including removal of exiting unsv all as specified and directed.
(a) 4 pole 63 Amps
(b) 4 pole 100 Amps
(c) 4 pole 125 Amps
(d) 4 pole 160 Amps
(e) 4 pole 200 Amps
Disconnecting, taking out and removing old existing unserviceable underground, LT XLPE/PVC insulated Aluminium conductor cable of any description and in any position complete including taking down existing protection pipe etc, of any size of any core from ducts / trenches / poles /pipes etc complete all as specified and directed. ( Excavation earth work, sand cushioning, brick protection shall be measured and paid separately)
supply and Laying of LT XLPE insulated, heavy duty armoured electric cable with aluminium conductor 1100 Volts grade, cross-sectional area 35 sqmm 3.5 core laid in trenches/ducts, floors, fixed to walls etc. all as Specified and as directed by the Engineer-in-Charge.
supply and Laying of LT XLPE insulated, heavy duty armoured electric cable with aluminium conductor 1100 Volts grade, cross-sectional area 50 sqmm 3.5 core laid in trenches/ducts, floors, fixed to walls etc.all as Specified and as directed by the Engineer-in-Charge.
supply and Laying of LT XLPE insulated, heavy duty armoured electric cable with aluminium conductor 1100 Volts grade, cross-sectional area 70 sqmm 3.5 core laid in trenches/ducts, floors, fixed to walls etc.all as Specified and as directed by the Engineer-in-Charge.
supply and Laying of LT XLPE insulated, heavy duty armoured electric cable with aluminium conductor 1100 Volts grade, cross-sectional area 120 sqmm 3.5 core laid in trenches/ducts, floors, fixed to walls etc.all as Specified and as directed by the Engineer-in-Charge.
supply and Laying of LT XLPE insulated, heavy duty armoured electric cable with aluminium conductor 1100 Volts grade, cross-sectional area 25 sqmm 3.5 core laid in trenches/ducts, floors, fixed to walls etc.all as Specified and as directed by the Engineer-in-Charge.
supply and Laying of LT XLPE insulated, heavy duty armoured electric cable with aluminium conductor 1100 Volts grade, cross-sectional area 16 sqmm 4 core laid in trenches/ducts, floors, fixed to walls etc.all as Specified and as directed by the Engineer-in-Charge.
supply and Laying of LT XLPE insulated, heavy duty armoured electric cable with aluminium conductor 1100 Volts grade, cross-sectional area 10sqmm 4 core laid in trenches/ducts, floors, fixed to walls etc.all as Specified and as directed by the Engineer-in-Charge.
M&L cable jointing kit for 1.1 KV grade cable for straight through heat shrinkble type joint complete with jointing material suitable 3.5 core XLPE aluminum conductor cable size 35 sqmm to 120 Sqmm all as Specified and as directed by the Engineer-in-Charge.
Excavation in trenches not exc 1.5 Mtr wide and not exc 1.5 Mtr deep for pipe line/cable in any type of soil getting out and levelling of bottom surface to required level complete all as specified and as directed.
Returning filling in, including spreading, leveling, watering and well ramming in layers not exc 25Cum thick complete all as specified and as directed.
Removing excavated material from site to a distance not exc 50 mtr away and depositing where directed not exc 1.5mtr from the starting point complete all as specified and as directed.
Supplying and laying of Sub class 'B' bricks in trenches for protection to cable complete all as specified and as directed.
Supplying and filling in trenches Jamuna Sand for cushioning complete all as specified and as directed.
Supply installation commissioning and testing of Retrofitting of Emission Control Devices/ Equipment on DG Set of 160 KVA of any make alternator & 6G11TAG29 model primover & leory somer make alternator having a minimum specified particulate matter capturing efficiency of at least of 70% in 5 mode D2 cycle, reduction efficiency of CO, HC and PM 2.5&10. Notes:- (i) System to be robust enough for cold start and start up oil emissions such that there is no impact an overall maintenance cycle timelines. (ii) Operating back pressure limit to be <3.3 KPa at Rated load. (iii) Maintenance cycle to be 5-6 months or 500 hours whichever is earlier. (iv) Noise levels to be within CPCB guidelines without silencer. (v) Passive regeneration to be achieved with max 10% duty cycle above 25%load. (vi) Overall power consumption to be lower than 1% of DG rated power. (vii) The Emission Control Device/ Equipment must be tested over an ISO-8178 5 mode D2 cycle for equivalent KVA rating at any one of the five Central Pollution Control Board. Govt of India, recognized/ approved laboratories as given below: a. Automative Research Association of India, Pune (Maharashtra) b. International Centre for Automative Technology, Manesar (Haryana) c. Indian Oil Corporation, Research and Developmeent Centre, Faridabad (Haryanan) d.Vehicle Research Development Establishment, Ahmednagar(Maharashtra)
Supply installation commissioning and testing of Retrofitting of Emission Control Devices/ Equipment on DG Set of 200 KVA of any make alternator having a minimum specified particulate matter capturing efficiency of at least of 70% in 5 mode D2 cycle, reduction efficiency of CO, HC and PM 2.5&10. Notes:- (i) System to be robust enough for cold start and start up oil emissions such that there is no impact an overall maintenance cycle timelines. (ii) Operating back pressure limit to be <3.3 KPa at Rated load. (iii) Maintenance cycle to be 5-6 months or 500 hours whichever is earlier. (iv) Noise levels to be within CPCB guidelines without silencer. (v) Passive regeneration to be achieved with max 10% duty cycle above 25%load. (vi) Overall power consumption to be lower than 1% of DG rated power. (vii) The Emission Control Device/ Equipment must be tested over an ISO-8178 5 mode D2 cycle for equivalent KVA rating at any one of the five Central Pollution Control Board. Govt of India, recognized/ approved laboratories as given below: a. Automative Research Association of India, Pune (Maharashtra) b. International Centre for Automative Technology, Manesar (Haryana) c. Indian Oil Corporation, Research and Developmeent Centre, Faridabad (Haryanan) d.Vehicle Research Development Establishment, Ahmednagar(Maharashtra)
S&F in replacement 3 pole power contactor ML-3, 28-42 Amps 415 volts, 50 HZ suitable for fixing in existing panel complete all as specified and directed by Engineer-in-Charge
S&F in replacement 3 pole power contactor ML-02, 20-32 Amps 415 volts, 50 HZ suitable for fixing in existing panel complete all as specified and directed by Engineer-in-Charge
S&F in replacement 3 pole power contactor ML-1.5, 25 Amps suitable for fixing in existing panel complete all as specified and directed by Engineer-in-Charge
S&F in replacement of fully automatic star - delta straters in sheet enclosure type ML-1.5 FASD complete all as specified and directed by Engineer-in-Charge
Supply and fixing in replacement of fully automatic star delta starter type ML-2 complete all as specified and directed by Engineer-in-Charge
S&F in replacement of fully automatic star - delta straters in sheet enclosure type ML-3 FASD complete all as specified and directed by Engineer-in-Charge
Supply and fixing in replacement of fully automatic star delta starter type ML-4 complete all as specified and directed by Engineer-in-Charge
S&F in replacement offload changeover switch 4 pole 250 Amps in sheet enclosure compete all as specified and directed by Engr-in-Charge.
S&F in replacement offload changeover switch 4 pole 320 Amps sheet enclosure compete all as specified and directed by Engr-in-Charge.
S&F in replacement offload changeover switch 4 pole 400 Amps sheet enclosure compete all as specified and directed by Engr-in-Charge.
S&F in replacement of electromagnetic Flow meter of size 80mm with inline monitoring, IP 68 flow sensor protection, IP 65 display enclosure, accuracy +/- 0.5% of MV, IP 65 display enclosure complete all as specified and directed.
S & F in replacement of street light energy saving envoirmental friendly long life LED street light/Bldg security light made of pressure die cast aluminium housing with with high power LED 60 Watt as light source confirming to IP 66 complete all as specified and directed.
Supply and fill genuine coolant in 5 ltrs plastic sealed container for topping up in Radiator of DG set located at different locations as directed by Engr-in-Charge complete all as specified and as directed.
M&L cleaning oil fuel tank of DG sets of any make and capacity including replacement of fuel level indicating tube and markings of suitable quantity of OEM recommendation all as specified and directed.
M&L painting of DG set with two coats of spray painting by spray machine with synthetic enamel paint as per colour code after preparation of old painted surfaces and writing SM/MES nos etc all as directed ofr the following Capacity :-
(a) 100 to 200 KVA Capacity DG Set
(b) 50 to 75 KVA Capacity DG Set
(c) 50 to 250 KVA capacity DG Set but only inside and outside for the aucustic enclosure of the DG set.
S&F in repair of Battery charger with variable voltage for 12V,upto 180AH battery complete all as directed.
S&F in repair of Battery charger with variable voltage for 2x12V,upto 180AH battery complete all as directed.
supply and fix in replacement street light bracket 1.2 mtr long made out of 40 mm dia light grade GI tuing made to shape including two sets of flat iron clamps , nuts , bolts washers complete all as specifiedand directed. ( Clamp shall be made of 40 x6 mm flat iron and fixed with 15mm dia x 50 mm long bolts nuts . Wt of each clamp shall not be more than 5 kg including wt of nuts and bolts . Providing two coats of aluminium paint over one coat of red oxide primer shall be part of item at extra c no cost .)
Supplying and fixing in replacement of 1.5 sqmm of PVC insulated copper conductor,three core cable in the existing surface /recessedPVC/Steel conduit /PVC casing caping as required complete all as specified and directed.
Supplying and fixing of chequerred rubber matting of size 2Mx1Mx10mm complete all as specified and directed.
M & L for Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground earth pit not less than 2.25mtr deep below normal ground level with top edge of the plate not less than 1.5 mtr below ground level connected to galvanized iron strep 32 x 6 mm as earthing lead by mean of nut/bolt and washer of galvanized iron or steel drawn through 40 mm dia light grade GI pipe as shown in electrical plate no 3 of SSR part I of 2009 including necessary excavation and earth work GI pipe 20mm dia light grade for watering PCC chamber with PCC cover in cement concrete 1:2:4 Type B1(20mm graded aggregate), funnel, wire mesh, charcoal dust, salt etc, connected to panel board as indicated including testing complete.
(Note For sl item no-1 to 100:- (a) Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of parts in 'Each' , cables in 'RM' , copper winding in 'kg' , lights and electrical fittings in 'Each',battery in 'Each' 'shall be taken into account and attach with RAR/F Bill)
New Era Engineers
Microsys Controls India
Ridhi engineers and builders
SREE BABA TRADERS
KUSHAL ENTERPRISES
Surjit and Sons
B.R. Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .