Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹89.4 LAccepted-AOC | 1 | Accepted-AOC LOWEST | |
| 2 | 2₹99.9 L+₹10.0 L (11.1%)Rejected-Finance RAVI KIRAN MARKET JIWAJI CHOWK BADA LASHKAR GWALIOR M P 474001 | GWALIOR | GWALIOR | MADHYA PRADESH | 474001 | 2 | Rejected-Finance NOT LOWEST | |
| 3 | Rejected-Technical | - | Rejected-Technical Firm is not enlisted in eligible Category | |
| 4 | Rejected-Technical | - | Rejected-Technical Firm enlisted for air conditioning and refrigeration repair works only | |
| 5 | Rejected-Technical 84 A VIJAY NAGAR COLONY LALGHATI PO NAYAPURA BHOPAL 462032 | 462032 | - | Rejected-Technical Firm enlisted for air conditioning and refrigeration repair works only |
Tender Value
₹1.0 Cr
EMD Value
₹1.8 L
Closing Date
23 Mar 2023, 6:00 pmClosed
CWE (AF) Gwalior
CWE (AF) Gwalior
PROVN OF CENTRAL ELINT COMPLEX AT EWR AND SPECIAL REPAIR /REPLACEMENT OF CHILLER PLANTS, PACKAGE UNITS AT EWS AND HOT BLOWER AT SES PARACHUTE BAY AT AF STN GWALIOR
2023_MES_577696_1
85044
Open Tender
Civil Works
Item Rate
270 days
Gwalior
Please refer Tender documents.
9 documents required · 9 mandatory
₹1,000
GE (AF) TECH AREA GWALIOR
₹1.8 L
Yes
26 Apr 2023
28 Jan 2023
27 Mar 2023
28 Jan 2023
23 Mar 2023
9 Mar 2023
Amount
S&F powder coated aluminium deco grills size 4mmx4mm, 8mm thick and aperture not exceeding 80 mm X 80 mm width and including fixing with aluminium channel, 1 mm thick with steel screw and tint match with existing complete all as specified and as directed.
Taking down chowkats or frames with shutters (without taking off shutters from the frames) exceeding 1.5 Sqm but not exceeding 4 Sqm each including builders hardware etc complete all as specified and directed.
Taking down chowkats or frames with shutters (without taking off shutters from the frames) not exceeding 1.5 Sqm each etc. including builders hardware etc. complete all as specified and directed .
M&L for framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete of Fe-410- W(Gde E-250) quality B complete all as specified and directed.
M&L for framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe-290 Gde-E-165 complete all as specified and directed.
M&L for preparing new surface of steel over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed.
M&L for preparing new surface of steel n.exc 10cm in width or girth applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed.
S&F galvanised mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed.
S&F MS galvanised powder coated suspended false ceiling system with grid of size 605mm x 605mm, consisting of mild steel galvanised powder coated main runner of size 24mmx32mm and cross Tee of size 24mm x 27 mm and wall angle of size 22.2mmx22.2mm, suspended with 4 mm dia GI wire hanger at 1200 mm spacing, fixed with steel dash fasteners or from purlin of roofs with butterfly clips etc includding12mm thick gypsum board (Semi-perforted) in ceiling fixed to GI snap grid framework with hold screws, of any height upto 8.5m with adjustable cleat of J hook including making provision for housing light fitting, AC grills, etc. complete including fixing, re-fixing false ceiling lights, wastage T&P as per manufacturer's instructions complete all as specified and directed.
Taking down cement plaster on brick or stone masonry, etc. including raking out joints , hacking for key and scrubbing down with water, etc complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
M&L for 25mm thick cement concrete type B-0, 1:2:4 (using 12.5mm graded stone aggregate) as in sub-base of floor tiles or roof surfaces complete all as specified and directed.
Material and Labour for machine cut Kota stone slab 20 to 25mm mm thick in treads, landings of staircase, over cement screed bed laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including and grinding polishing, over and including screed bed 20mm thick in CM 1:6 etc complete all as specified and as directed.
Material and Labour for machine cut Kota stone slab 20 to 25 mm thick as in skirting, risers, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing with mirror polish granite finish including backing coat 15 mm thick in CM 1:6 complete all as specified and as directed.
M&L for Vitrified coloured ceramic tiles, double charged 10 mm thick (Square/rectangular) area of each tile not exceeding 0.36 Sqm, in floors etc set & jointed in neat cement slurry and pointed in cloured cement to match the shade of tiles over & including 15 mm thick screed bed in cement mortar (1:6) etc complete all as specified & directed.
M&L for coloured glazed ceramic tiles of size 350 x 250 x 7/450 x 350 x 7mm thick on vertical surfaces such as in dado/skirting set and jointed in neat cement slurry and pointed in white or colour cement to match and rendering in and including 10mm thick Cement mortar 1:3, on fair faces of wall surfaces etc, complete all as specified and directed.
M&L for non skid joint free coloured ceramic floor tiles 7-8 mm thick (Square/rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm, in floors etc set & jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles, over & including 15 mm thick screed bed in cement mortar (1:6) complete all as specified & directed.
M&L for providing and fixing stainless steel (ISI marked Grade 304) railing made of hollow tubes, channels, plates, etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts including fixing the railing with necessary accessories & stainless steel dash fasteners, etc., of required size, on the top of wall, floor or the side of waist slab with suitable arrangement complete all as specified and directed.
S&F sinks with drainage board made of stainless steel 1 mm thick as in kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x160mm etc complete all as specified and directed.
Taking up or down steel water tubing and connections of 15mm bore including cleaning for refixing or removal to store complete all as specified and as directed.
Taking up or down steel water tubing and connections of 20mm bore including cleaning for refixing or removal to store complete all as specified and as directed.
S&F steel tubing 15mm bore medium grade with all fittings and fixed to wall, floor and ceiling etc complete all as specified and directed
S&F steel tubing 20mm bore medium grade with all fittings and fixed to wall, floor and ceiling etc complete all as specified and directed
M&L for cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves lintels, etc. and cutting chases for concealed water tubing and making good, cutting not exc. 10cm girth complete all as specified and directed
S&F rotational moulded ployethylene water storage tank (cylindrical vertical with closed top) hoisted and fixed in position all as specified of 2000 Ltr capacity complete all as specified and directed.
S&F float valve/ball valve high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe ( Min. wt. 20 mm -210 gms ) suitable for 20 mm dia Pipe complete all as specified and directed.
S&F in repair 20mm dia Gun metal globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
S&F in repair 15mm dia Gun metal globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed..
S&F Toilet paper holder, vitreous china, box type coloured complete all as specified and directed.
Supply only PVC connection 15 mm size 600mm long with PTMT nut complete all as specified and directed .
S&F in repair vitreous china wash down water closet pan (pedestal pattern), white, with and including plastic water closet seat, white, closed pattern with flat bottom and cover and mild steel chromium plated or aluminised hinging device, (excluding fixing bolts, flushing cistern and flush pipe), including connection to drain (or outgoing pipe) and to flushing pipe, anti -syphonage pipe, etc., complete all as specified and directed.
S&F vitreous china urinal full stall urinal complete including providing and fixing plug bedding urinal against wall in CM 1:2 securing urinal to plugs with & including 60mm brass screws pointing around urinal back in cement, including fixing CP water spreader with brackets, flush pipe, CP grating and union for discharge pipe, including any accessories which are required to stall the urinal complete all as specified and directed.
S&F PVC valve less, symphonic action type low level flushing cistern white with inlet ball valve, float and handle including brackets, 10 ltr capacity complete with flush pipe (Long bend) 32mm dia complete all as specified & directed.
S&F in repairs 15 mm dia bore bib taps cast copper alloy with fancy type, chromium plated capstan head long body with wall flange, screwed for iron pipe, or for brass ferrule complete all as specified and as directed.
S&F in repair 15 mm dia bore cast copper alloy chromium plated fancy type angular stop cock with flange complete all as specified and as directed.
Supply and fix 15 mm bore pillar taps, cast copper alloy, with capstan heads, chromium plated , fancy type screwed down for pipe, high pressure , with or without lettered ' 'HOT' or 'COLD' with long screwed shanks and fly-nuts , screwed for iron pipe complete all as specified and directed.
S&F as in repair 32 mm brass chromium plated bottle traps for wash basins with inlet and outlet screwed for pipes or connections including necessary packing union cap complete all as specified and directed.
S&F sheet glass self assembly consisting of 5.5 mm thick sheet glass shelf 12 cm wide with chromium plated bracket guard and railing 60 cm long complete all as specified and directed.
S&F in repairs soap dish of vitreous china, white size 160mmx160mmx190mm embedded to wall complete all as specified and as directed.
M&L for 100mm dia cast iron floor trap including 100mm dia PTMT Gratting doom including jointing to waste pipe fixed in PCC (1:2:4) type B-1, complete all as specified and directed.
S&F in repairs vitreous china counter top wash hand basin, white, flat back, size 560 x 455mm excluding taps, waste pipe & PTMT waste coupling of 32mm dia complete all as specified and directed.
S&F chromium plated brass tubular towel ring fixed with CP screws and wood cleats with wall complete all as specified and directed.
S&F in repairs satinless steel CP towel rack 600mm long with lower hangers fixed with CP screws and wood cleats with wall complete all as specified and directed.
S&F in repairs stainless steel CP hand shower (heath faucet) with 1 metre flexible pipe with wall hook complete all as specified and directed.
S&F solid PVC door frame of size 50 mm x 47 mm made out of 5 mm thick plain colour PVC sheet reinforced with MS Square tube complete all as specified and directed.
S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top & bottom rails MS frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20 mm width stuck in side with solvent cement for styles and plain colour PVC sheet for top rail ,lock rail & bottom rail on either sides and as gap insert for top rail & bottom rail ,panelling of plain colour PVC sheet to be fitted in the MS frame welded -sealed to the styles & rails with suitable PVC sheet beading, and joint together with solvent cement complete all as specified and directed.
S&F stainless steel butt hinges medium weight cold rolled and fixed 100 mm long complete all as specified and directed.
S&F stainless steel tower bolts of extruded section and fixed 150 mm long complete all as specified and directed.
S&F stainless steel handle 150 mm long complete all as specified and directed.
S&F stainless steel sliding door bolt with hasp staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding both of extruded sections of cast aluminium alloy 300 mm long all as specified and directed.
M&L for brickwork with sub class 'B' bricks straight or curved on plan exc 6m mean radius built in cement mortar (1:6) complete all as specified and as directed.
M&L for complete removal of existing treatment from old surface of wall, shall be sanded through mechanical wall sander to remove all the previous layer and exposes the plaster surface, including filling depression of scrapped surfaces and apply two coats of distemper oil emulsion (OBD) over a layer of wall care putty not less than 1mm thick complete all as specified and directed. Note: (i) .Putty shall be prepared in liquid form as per manufacturer's specifications and shall be allowed to dry for 6 to 8 hours. (ii) The work shall be executed by authorised applicators of make approved by GE.
M&L for preparation of old surface of ceiling and applying one coat of distemper oil emulsion, white or tinted, complete all as specified and as directed.
Material and Labour for rendering 15 mm thick in cement mortar (1:6) on fair faces of brickwork or concrete surface, finished even and fair without using extra cement complete all as specified and directed.
M&L for preparation of newly plastered surfaces of wall and applying two coat distemper emulsion (OBD) with roller finish over a coat of cement wall primer (for same manufacturing of OBD) over and including layer of wall care putty not less than 3mm thick complete all as specified and directed.
Material & Labour for applying one coat of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new & old surfaces complete all as specified and directed.
M&L for providing and fixing Gypsum Board 12mm thick in walling fixed with screw including anodised aluminium snap grid for framework complete all as specified and directed.
S&F UPVC luxury casement sound-proof side hung (Tilt & Turn type) windows and frame with double glass glazing 65mm/C65PS3/Z-SASH, DG INS, TGH ( 5T+12+5T) internal plain and external tinted with cylinder of one side key, one side thumb turn and locking system including necessary builders' hardware etc complete weight not less than 32 Kg/Sqm complete all as specified and directed.
S&F UPVC sound-proof door and frame with double tinted glass glazing 65mm/C65PS3/Z-SASH, DG INS, TGH ( 5T+12+5T)with cylinder of one side key , one side thumb turn and locking system including necessary builders hardware etc complete weight not less than 32 Kg/Sqm complete all as specified and directed.
Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth for foundation, laying pipes cables, etc n.exc 10 sqm on plan and n.exc 1.5m depth and getting out in soft /loose soil complete all as specified and directed.
S&F Reinforced concrete pipes, class NP-2, laid and jointed complete with collars - Bore of pipe 150mm complete all as specified and directed.
Material and Labour for cement concrete (1:3:6) type C-2 (using 40mm graded crushed stone aggregate) as in concrete bed to drain pipe including packing under and haunching against the sides of pipe after they are laid and tested complete for pipe of 150mm bore complete all as specified and directed.
M&L for cement concrete (1:4:8) type D-2 (using 40mm graded stone aggregate) as in foundation , filling and mass concrete complete all as specified and directed.
M&L for PCC 1:2:4 type B-0 (using 12.5mm graded stone aggregate) as in coping and benching for manholes including necessary form work complete all as specified and directed..
Extra for forming fair finished drain or channel 30cm inner girth in cement concrete using extra cement including forms moulds etc. complete all as specified and directed.
Add or deduct item No 67 for each 25mm girth over and under 30mm or part thereof complete all as specified and directed.
M&L RCC precast cement concrete 1:2:4 type B-1 (20mm graded stone aggregate ) for MH cover, set in CM 1:6 complete all as specified and directed. Note : Steel for reinforcement shall be measured and paid separately.
Material and Labour for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking bending spirally for hooping for column,, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, etc complete all as specified and directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers of 25 cm thick after the cables etc. are laid, jointed and tested, if any, complete all as specified and directed by Engineer-in-Charge.
Removing excavated material ie. soils, exc 250m but n.exc 500m and depositing where directed at a level not exc 1.5 Mtrs above starting point complete all as specified and directed.
M&L for Construction of Septic Tank for 50 users including necessary earth work in excavation in soft/loose soil , plain cement concrete 1:2:4 type B-2 ( using 40 mm graded crushed stone aggregate ) as in foundation , brickwork with using sub class "A" class bricks cement mortar 1:4 , reinforced cement concrete M-25 ( design mix) as in slab cover including pre-cast manhole cover slab having 8 mm dia TMT bar reinforcement @ 75 mm c/c & 6 mm thick mild steel plate embedded all around of cover slab, 15 mm thick plaster in cement sand mortar in 1:4 on wall, vent shaft, sludge chamber, formwork to sides and soffits, 150 mm dia SGSW inlet & outlet pipes up to 3 m from outer face of wall, CI vent pipe, sludge chamber, RCC baffle wall, returning filling & removal etc, complete all as shown on drawing No.TD-217 sheet1/2 & 2/2 and as specified.
Excavation over areas, n exc 1.5 m deep and getting out in soft/loose soil complete all as specified and directed.
Removing excavated material exc. 1.50 km but n exc. 5 km and depositing where directed at a level not exc 1.5 Mtrs above starting point complete all as specified and directed.
M&L for 100mm thick hardcore using broken stone or boulders of gauge n.exc.63mm.deposited spread and levelled in layers n. exc.15 cm thick, watered and rammed to true surface complete all as specified and directed.
M&L for 100 mm thick PCC 1:4:8 type D-2, (using 40mm graded stone aggregate) as in sub base/ floor complete all as specified and directed.
M&L for Cement Concrete M-25 design mix using 20mm graded stone aggregate for road and pavement complete all as specified and directed.
M&L for Forming Contraction (dummy) joints 65mm deep x 10mm wide filling with sealing compound Grade B complete all as specified and directed
Taking down carefully existing unserviceable copper/ aluminium point wiring of any description & in any position with and including pvc/steel conduit all fitting, accessories & fixtures such as switches, ceiling roses, pendants, regulators, socket, light fittings call bell, lamp holders etc and making good the disturbed surface of walls, floors, ceiling etc to match with the existing surfaces complete all as specified and directed. Note: Old fittings/fixtures/accessories like switch, sockets, lamp holders, regulators light fittings etc found in serviceable condition shall be removed carefully for reuse in the work and shall be paid for separately under appropriate item of Schedule `A’.
Material and labour for point wiring for one light /fan/Exhaust fan point controlled by one switch with using 1.5 Sqmm (nominal area) stranded copper conductor, single core, PVC insulated & unsheathed cable FRLSH,1100 volts grade in and including concealed PVC conduits (Medium grade) of size not less than 20 mm dia all as directed with sunken type pressed steel terminal box and junction boxes 1.6mm thick of suitable size, duly painted with one coat of red oxide primer and two coats of black bituminous paint for mounting fittings and wiring to be terminated in pressed steel sunken boxes with laminated top sheet of 3 mm thick for housing of switches, sockets, regulators etc including all accessories and using 1.5 Sqmm (nominal area) stranded copper conductor single core conductor, PVC insulated & unsheathed cable as in earth wire connected to common earth dolly complete all as specified and directed. Note :-(I) The portion of point wiring at ceiling shall be in surface PVC conduit/ casing & caping of suitable size fixed on ceiling surface with using PVC rawl plugs. (ii) Fittings like switches, sockets, regulators, lamp holders, light fittings shall be measured and paid for separately under appropriate item of Schedule `A'. (iii) The quoted rates shall be deemed to be inclusive for provision of covering sunken boards/terminal boxes / junction boxes of any shape and size with 3mm thick laminated sheet fixed with suitable brass screws and cup washers.
All as per item No 81 here-in-before but point wiring for 5 pin switch socket outlet combination, 5/6 Amps on independent board complete all as specified and directed..
All as per item No 81 here-in-before but point wiring for two way point for calling bell/stair case etc complete all as specified and directed..
Material and labour for point wiring for one light /fan/Exhaust fan point controlled by one switch with using 2.5 Sqmm (nominal area) stranded copper conductor, single core, PVC insulated & unsheathed cable FRLSH,1100 volts grade in and including concealed PVC conduits (Medium grade) of size not less than 20 mm dia all as directed with sunken type pressed steel terminal box and junction boxes 1.6mm thick of suitable size, duly painted with one coat of red oxide primer and two coats of black bituminous paint for mounting fittings and wiring to be terminated in pressed steel sunken boxes with laminated top sheet of 3 mm thick for housing of switchs, sockets, regulators etc including all accessories and using 2.5 Sqmm (nominal area) stranded copper conductor single core conductor, PVC insulated & unsheathed cable as in earth wire connected to common earth dolly complete all as specified and directed. Note :-(I) The portion of point wiring at ceiling shall be in surface PVC conduit/ casing & capping of suitable size fixed on ceiling surface with using PVC rawl plugs.(ii) Fittings like switches, sockets, regulators, lamp holders, light fittings shall be measured and paid for separately under appropriate item of Schedule `A'.(iii) The quoted rates shall be deemed to be inclusive for provision of covering sunken boards/terminal boxes / junction boxes of any shape and size with 3mm thick laminated sheet fixed with suitable brass screws and cup washers.
S&F switch Modular type flush type single pole one way 6 Amps,1 module complete all as specified and directed.
S&F moduler switch socket 6 Amps -2/3 pin combined 2 module, complete all as specified and directed.
S&F Modular Switch socket 6/ 16 Amps 2/3 Pin combined 2 module complete all as specified and directed.
Supply and fixing in repair step type electronic fan regulator single phase, 230 volt, 100/120 watt complete all as specified and directed.
Supply and fixing ceiling fans complete with blades, down rods and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed.
Taking down carefully existing light fittings from its original position by unscrewing and making good the disturbed surfaces of walls, ceiling floors etc all as directed. complete all as directed by Eng-in-Charge.
Supply and fixing 8 Watt Recess mounted fixed LED down light made of extruded aluminium housing and high power LED as light source with diffuser and driver complete all as specified and directed by Engr-in-charge.
Supplying & fixing 40 watt Stout plus LED is a complete range of industrial LED batten to replace traditional T8 batten. The range is perfect for lighting large areas such as corridor ,warehouses & general purpose spaces including all accessories, pre-wired and connecting the same to ceiling rose with & including three core PVC insulated and sheathed copper conductor 1.5 sqmm cable with all accessories and fixing arrangement for fixing the light fitting to walls / roof surface complete all as specified and directed.
Supplying, fixing & testing decorative recess mounting 36 watt LED full out put luminaries which provides soft light glare free symmetrical illumination suitable for Armstrong/Grid ceiling, white powder coated sheet steel housing with paralite P5 square parabolic louver block in metallic perforated frame for low glare, aluminium reflector and accessories and PIR sensor/motion sensor ,connecting the same to electric source with and including copper conductor 23/0.0076 flexible twisted twin core cable , including all accessories and fixing arrangements for fixing the light fitting to false ceiling complete all as specified and directed.
Supply and fixing LED street light fitting 35 Watt 230V AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp bracket with impact and corrsion resistant including thermal management in multiple optics complete with Ip-66 protection complete all as specified and directed.
S&F ceiling rose, surface bakelite 18 mm X 50 mm AC, 230 V polycarbonate isolated body, two or three terminals complete all as specified and directed.
Taking down carefully existing DB from its original position by unscrewing and making good the disturbed surfaces of walls etc all as directed. complete all as directed by Eng-in-Charge.
Supply and fixing of sheet metal enclosure Double door for DB’s 4 way 240 Volts with 200 Amps rated bus bar for single phase and neutral supply complete fixed properly on in concealed position and to connect their incoming/outgoing electric connections by means of suitable sizes of lugs/thimbles and to provide required sizes of flexible conduit at any open surfaces near DB’s of cables/wires all as directed.
Supply and fixing of sheet metal enclosure Double door for DB’s 8 way 240 Volts with 200 Amps rated bus bar for single phase and neutral supply complete fixed properly on in concealed position and to connect their incoming/outgoing electric connections by means of suitable sizes of lugs/thimbles and to provide required sizes of flexible conduit at any open surfaces near DB’s of cables/wires all as directed.
Taking down carefully existing MCCB/MCB from its original position by unscrewing and making good the disturbed surfaces of walls etc all as directed. complete all as directed by Eng-in-Charge.
S&F MCB SP 6 to 32 Amps ('B' Series) having current rating 10 kA, 240 V complete all as specified and as directed.
S&F MCB SPN 6 to 32 Amps ('B' Series) having current rating 10 kA, 240 V complete all as specified and as directed.
Supply and fixing factory made epoxy powder coated distribution board VTP & N 4 ways (TPN MCCB DB) with metal double door (IP-54 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with Knockouts and suitable for one TP-MCCB 160Amps as incomer and 12 SP MCBs or 4 TP MCBs (or any combination of SP/TP MCBs ) outgoings complete all as specified and directed.
Supply and Fix, for MCCB , 4 pole 160 Amps, 16 KA 415 Volts all as specified and repturing capacity 16 KA. complete all as specified and directed.
M&L for Earthing complete with galvanised steel earth plate electrode, 600mm x 600mm x 6mm thick, buried directly in the ground (earth pit not less than 2.25m deep below normal (ground level) with top edge of the plate not less than 1.50m below ground level connected to galvanized iron wire 4mm dia as earth lead by means of bolts, nuts and washers of GI up to test point, GI tubing 20 mm bore light grade protection pipe, GI watering pipe 20mm bore medium grade with funnel and wire mesh, charcoal, magnesium, salt, etc. & 50mm thick pre-cast RCC (1:2:4) type B-1 (Nominal mix) cover reinforced with 8 mm dia TMT bar @100 mm centre to centre both ways with mild steel handle 12 mm dia, plastering 12 mm thick in cement mortar (1:6) internally and upto 150 mm below ground level externally with suitable steel handle and angle iron 40X40X6mm frame and chamber of PCC (1:3:6) type C-1 (including earth work in any type of soil, removal of surplus soil to a distance n.exc.50m) and connecting, testing on completion, all as shown on electric plate No. 03 of SSR-2009 Part-I, including taking down of existing earthing complete all as directed. Notes: 1. Earth lead & protection pipes length upto & including 7.50 metre is included in the quoted rate. 2. Earth filling shall be done by vegetable soil. 3. Soil should be free from stone, boulders, aggregate, gravels etc.
Taking down carefully existing sub main wiring from its original position and making good the disturbed surfaces of walls etc all as directed. complete all as directed by Eng-in-Charge.
M&L for surface/concealed submain wiring as required with two single core FRLSH PVC insulated and unsheathed copper stranded conductor of size 4 Sqmm 1100 Volts and one run of copper stranded conductor of size 4 Sqmm for continuous earthing drawn in and including rigid non metallic PVC conduit pipe ISI marked of size not less than 20 mm dia including to connect their incoming/outgoing electric connections by using required sizes of lugs/thimbles as well as flexible conduit of suitable sizes shall also be used at any open surfaces of conductor complete all as specified and directed. Note :- (i) Two single core cable and one run of earth copper conductor including conduit will be measured and paid as one unit length. (ii) The quoted rate shall be deemed to be inclusive for cutting chases in wall/pillars/columns etc of any description for concealing the conduits to required depth and making good the disturbed surface in cement mortar 1:4 including finishing the surface to match with the existing surface. .
M&L for surface/concealed submain wiring as required with two single core FRLSH PVC insulated and unsheathed copper stranded conductor of size 6 Sqmm 1100 Volts and one run of copper stranded conductor of size 6 Sqmm for continuous earthing drawn in and including rigid non metallic PVC conduit pipe ISI marked of size not less than 20 mm dia including to connect their incoming/outgoing electric connections by using required sizes of lugs/thimbles as well as flexible conduit of suitable sizes shall also be used at any open surfaces of conductor complete all as specified and directed. Note :- (i) Two single core cable and one run of earth copper conductor including conduit will be measured and paid as one unit length. (ii) The quoted rate shall be deemed to be inclusive for cutting chases in wall/pillars/columns etc of any description for concealing the conduits to required depth and making good the disturbed surface in cement mortar 1:4 including finishing the surface to match with the existing surface.
M&L for surface/concealed submain wiring as required with Four single core FRLSH PVC insulated and unsheathed copper stranded conductor of size 6 Sqmm 1100 Volts and one run of copper stranded conductor of size 6 Sqmm for continuous earthing drawn in and including rigid non metallic PVC conduit pipe ISI marked of size not less than 20 mm dia including to connect their incoming/outgoing electric connections by using required sizes of lugs/thimbles as well as flexible conduit of suitable sizes shall also be used at any open surfaces of conductor complete all as specified and directed. Note :- (i) Four single core cable and one run of earth copper conductor including conduit will be measured and paid as one unit length. (ii) The quoted rate shall be deemed to be inclusive for cutting chases in wall/pillars/columns etc of any description for concealing the conduits to required depth and making good the disturbed surface in cement mortar 1:4 including finishing the surface to match with the existing surface.
Supply and fix UPS for 30 min back-up single phase AC input 160 V to 260 V and output 230V +/- 1% of 10 kVA with battery bank unit complete with all connected accessories complete all as specified and directed.
Supply, fixing and commissioning (maximum energy efficient type) water heater storage type 25 litres capacity, vertical, plastic body including grouting of studs in wall in cement mortar (1:3) nuts, washers and provision of two numbers PVC connection 600mm long with brass nuts and two number brass chromium plated angular valve suitable for 15mm bore pipe for water supply connection complete all as specified and directed.
Supply and fixing non metallic 25 mm dia PVC conduit inclusive of tees, bends, elbows, reducers, bells mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc complete all as specified and directed.
Supply and fixing RJ-45 socket alongwith mounting boxes complete all as specified and directed.
M&L for earthing complete with galvanised steel earth plate electrode 60cm x 60 cm x 6.3 mm thick buried directly in ground (earth pit not less than 2.25m below ground level) with top edge of the plate not less than 1.5m below ground level connected to and including galvanised iron strip 25 x 4mm as earthing lead by means of GI bolts nuts check nuts and washers of galvanised iron or steel all as shown in electric plate No 5 SSR Part-I, connected to earthing etc all as specified including testing on completion with all necessary excavation in any kind of strata, earth work, PCC earth Pit in 1:3:6 CI RCC cover, CI funnel, GI watering Pipe 20 mm complete. Note :- (i) The length of the galvanised strip beyond 7.5m will be measured and paid separately. (ii) All joints of galvanised strips shall be of brass only. (iii) Test rresult of earthing to be submitted by the contractor for all earthing . (iv) Earth result of the pit shall be less than 5 ohms, during the maintenance period also to be maintained earth resistance less than 5 Ohms falling which new earthing to be provided by the contractor with out any extra cost. (v) The rates quoted by the contractor is deemed to be inclusive of cost of MS sheet for marking the result and its purpose of use of size 300mmX 300mmX3mm size fixed with necessary nuts and bolts on angle iron of length 60cm and size 40X40x5mm grouted in the ground with PCC (1:3:6) using 20mm grade stone masonry of size 200mmX200mmX250mm including necessary earth work. (vi) the rate quoted by the contractor shall also be deemed to be including (vii) Testing submission of earth result as desired. (viii) Excavation upto 2.25 mtrs depth and returning filling in any type of soil.
Supply, laying , jointing & testing XLPE insulated, screened ,PVC bedded, galvanised steel strip or wire armoured, electric power cable ( heavy duty) with standard aluminium conductor , 1100 Volts grade of cross sectional area 25 Sqmm 4 core complete all as specified and directed. Note : Excavation , earth work, sand cushioning for cable and cable protection cover shall be measured & paid under respective item.
Supply, laying , jointing & testing XLPE insulated,screened ,PVC bedded, galvanised steel strip or wire armoured, electirc power cable ( heavy duty) with standard aluminium conductor , 1100 Volts grade of cross sectional area 70 Sq mm 3.5 core complete all as specified and directed. Note : Excavation , earth work, sand cushioning for cable and cable protection cover shall be measured & paid under respective item.
Supply, laying , jointing & testing XLPE insulated, screened ,PVC bedded, galvanised steel strip or wire armoured, electric power cable ( heavy duty) with standard aluminium conductor, 1100 Volts grade of cross sectional area 150 Sq mm 3.5 core complete all as specified and directed. Note : Excavation , earth work, sand cushioning for cable and cable protection cover shall be measured & paid under respective item.
Removing excavated material to a distance n.exc 50 mtr and depositing where directed at a level n.exc 1.5 mtr above the starting point complete all as specified and directed..
Supply and spreading clean, dry, fine river sand for UG electric cable in two layers (8 cm thick before laying the cable & 15 cm thick after laying cable ) total 23 cm thick including gently punning the sand up to 18 cm (total thickness) and consolidated around cable for protection of under ground cable complete all as specified and directed. ( Note:- Only punned thickness shall be measured for payment).
Supply & laying unreinforced precast concrete cable cover class LV, Type I flat of size 250mm x150 mm x 40 mm (ISI marked) complete all as specified & directed. complete all as specified and directed by Engr-in-charge.
Supply and fix double wall corrugated (DWC) HDPE pipe 90mm OD for protection of LT/HT UG cables for crossing roads/on wall/poles etc including coupling/ jointing fittings complete if any all as directed and specified
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 MPa working pressure complete all as specified and directed by Engr-in-charge.
Supply, commissioning, erecting and testing complete of manufacturer or OEM manufactured, static silent (Sound Proof enclosure) Diesel Engine Driven Generating Set of capacity 100 KVA or next higher capacity, water cooled, 415 Volts (AC three phase, 4 Wire system of supply) 50 Hz at power factor 0.8 minimum. The DG Set shall consists of diesel engine coupled to a matching alternator, through flexible coupling and mounted on common base frame and complete with control panel standardized by manufacturer, fuel tank with mounting arrangements and inlet, outlet return inlet oil arrangement, exhaust pipe complete and suitable for conditions prevalent at Gwalior including PCC foundation (of suitable size leaving at least 0.5m all around for ease of movement and 0.5 M height), anti-vibration pads complete all as specified and directed, including all features to comply with latest CPCB guidelines and comprising of followings:-
Item No 122 cont.... (i) ENGINE (Prime Mover): Diesel Engine 1500 RPM, direct injection, multi cylinders, four stroke, confirming to IS:10000/ISO3046/BS:649/BS:5514 amended up to date, for continuous running capable of taking 10% overload for one hour in 12 hour, water cooled, naturally turbo charged, capable of giving adequate BHP to drive Alternator capable of delivering 250 KVA or next higher capacity at outdoor atmospheric conditions at Gwalior, fitted with following accessories:-
Item No 122 cont.... (a) Dynamically balanced fly wheel (b) Air cleaned oil bath type. (c) Electronic governer Class 1A. (d) Dry exhaust manifold with suitable exhaust residential grade silencer to reduce the noise level. (e) Radiator cooling. (f) Radiator fan with guard. (g)Vaccum indicator. (h) Fuel filter and fuel hoses. (j) Fuel injection pump (FIP) (k) Fan and water pump assembly. (l) Lubricating oil filter and pump. (m) Electrical starting system with battery charging alternator and axial type starter motor including adequate number of high capacity maintenance free lead acid battery, 12 Volts DC as per manufacturer recommendation including interconnecting cable/ leads with terminal complete with start/ stop switch. (n) Engine safety shut down system against low oil pressure and high water pressure. (o) Exhaust gas driven turbo charger. (p) Oil filter. (q) Lube oil cooler. (r) Engine maintenance manual with spare parts list. (s) Suitably designed acoustic enclosure as per CPCB regulation. (t) Any other item not included/ specified but is a standard design of the manufacturer.
Item No 122 cont.... (ii) ENGINE INSTRUMENT ELECTRONIC PANEL:- Engine instrument panel shall comprising of the following control : (a) Starting on/ off switch. (b) Water temperature display. (c) Hour meter cum RPM display. (d) Lub oil pressure display. (e) Lub oil temperature display. (f) Battery charging display. (g) Safety alarm against high water temperature and low oil pressure. (h) Automatic on/off of engine facility with GCU. (j) Any other item not included/ specified but is a standard design of the manufacturer.
Item No 122 cont.... (iii) ALTERNATOR:- Alternator shall be self excited, self regulated, brushless for 100 KVA or next higher capacity continuous operation at the speed of 1500 RPM at 415 Volts, 50 Hz, Three Phase, 4 Wire system with advance electronic voltage regulator to ensure high voltage accuracy with + / -1% with class H insulation and SPDP enclosure directly coupled with engine through flexible coupling and confirming to IS-4722 complete-01 No Note:- Alternator should be able to deliver output rating at actual site conditions.
Item No 122 cont.... (iv) Common fabricated base frame for engine and alternator made from structural channel leak proof PCC 1:2:4 mix, type B1 foundation including adequate number of suitable anti vibration pad all as per the recommendation of the manufacturer-01 Number (v) Bottom mounted (or as per manufacturer design) steel fuel tank fabricated out of 14 SWG MS sheet of capacity not less than 12 Hour continuous operation inside canopy with fuel level gauge, drain plug, locking arrangement etc with and including GI pipe connection duly laid as per Engineering practice complete.
Item No 122 cont.... (vii) Bypass arrangement by providing separate panel made out of 14 Gauge CRCA sheet, outdoor type with connecting copper bus bar of suitable size from change over and set of 3 Nos indication lamp for R, Y and B and 2 Nos 4 Pole on load change over switch front handle operated of capacity 400 amp is to be installed near AMF panel complete all as specified and directed. (viii) Hours run meter (ix) Any other item not included/ specified but is a standard design of the manufacturer.
Supply, Installed, Testing and Commissioning CPRI approved cubical type LT Panel floor mounted out door type for 415V, 3 phase 4 wire system 50 Hz AC supply with Copper bus bar duly colour coded, for neutral supported with DMC/SMC insulators colour coded with heat shrinkable sleeve having short circuit current with stand minimum 21 KA for one second complete connection from bus bar to breakers with suitable copper cable , factory made fabricated with CRCA sheet totally enclosed, dust weather and vermin proof for outer shell and 2 mm thick for inner shell having TPN copper bus bar rating 1.5 times that of controlling MCCB supported on SMC insulator with short circuit withstand capacity 35 MVA for 1 second, bottom base channel MS section not less than 100mm x 50mm x 5 mm thick, entire panel shall have a common copper earth bar of size 25mm x 5mm at the rear with 2 Nos earth stud, solid connection from main bus bar to switchgears with required size of copper wiring with minimum 1.5 Sqmm PVC insulated copper conductor cable , cable alleys, cable gland plates in two half including tamper proof digital energy meter to measure voltage current PF, KWH,KVAH,KVAR) and general construction confirming to IS-8623/93 and mounted on suitable PCC foundation for the complete panel base with following detailed specification & control :- complete with suitable fixing accessories.
Item No 130 cont.... OUTER SHELL :- The outer shell shall be made of 3. mm thick CRCA body & MS angle section 50x50x6 mm frame with front & back openable, single door system lockable/ openable by keys from both sides having flush pattern fancy locks with louvers & air vent gasket for natural flow of air. The bottom of the outer shell contains a detachable plate a hinge provision for entry of armoured cable of adequite size of glands. The dimension of the outer shell should be adequite to accododate inner shell described below figing 50 mm space all around and shall be fabricated in such a way that the comple inner shell alongiwth its control gears and accessories should be taken outside without disturbing outer shell. The outer shell shall be mounted on a zinc metal coated stand. Provision of threaded earthing studs at bottom and lifting lugs of suitable size at top to lift the feeder pillar box safely shall be made. Computer cut self adhesive vinly danger notice plate having conventional symbol of bone and skull shall be provided. The degree of protection of outer shell shall be IP-54.
Item No 130 cont....INNER SHELL :- Inner shell made of 2.0 mm thick CRCA body compartmentalized for each control gear, front openable single door system lockable/openable by keys from both sides having chromium plated fancy locks (2 Nos in each compartment) having louvers and air vents gasket for natural flow of air "U' type gasket shall be used to make the inner shell completely vermin proof and to accomodate incoming/outgoing MCCB's and TPN copper bus bar and extension links of rating not less than the 1.5 times rated capacity of the respective MCCB's. The TPN bus bar and extension links shall be insulated with colour coated heat, shrikable sleeve and shall be mounted on suitable size 'F' class through out the length of the TPN bus bar. Computer cut slef adhesive vinyl danger notice plate having conventional symbol of bone and skull shall be provided on bus bar chamber. All control wires shall be with not less than 1.5 Sqmm multistranded copper conductor and shall be properly bunched. tied, ferruled for proper identification and crimped with adequite size of lugs. The cubical shall have a bottom channel of size 75x50mm duly coated with zinc metal coating. A detachable predrilled gland plate of thickness 3.15 mm zinc metal coated should be used at the bottom, indicating lamps LED type, 230 Volt, AC at the incomer of the unit to show three phase availability at the incomer. An inspection lamp with 11 Watt CFL shall be fitted on top side of inner shell. The degree of protection for inner shell shall be IP-42 and carry the flowing control :-
S & F air termination single pointed alluminium rod, single pointed at top and properly threaded at bottom end 300 mm long, 12 mm dia complete all as specified and directed by Engineer-in-charge
Supply and fixing aluminium strip 25x3.15 mm with saddles and fixing screws etc for roof conductors and down conductors above ground complete all as specified and directed
Supply and fixing galvanized iron strip 32x6 mm buried under ground complete all as specified and directed.
M & L for providing test point terminal block made out of Gun metal or phosphorous bronze of size 75 mmx75 mm x25 mm drilled and screwed including 03 nos 8 mm dia 25 mm long hexagonal head screws complete all as specified and directed
M & L for PCC 1:2:4, type B-1 using 20 mm graded stone aggregate complete all as specified and directed.
S&F GI tubing medium grade 50mm dia for mechanical protection of earth continuity conductor complete all as specified and as directed by Engr-in-charge.
Supply, install, commissioning and testing of split type wall mounted Air conditioner of capacity 2 TR (6000 K Cal/hr) single phase, (Non CFC/HCHC) suitable for 230 Volt + 10% , 50 Hz, AC supply complete with cordless remote control unit , complete comprising of following :- (a) Indoor unit with three speed blower fan of appropriate capacity including PCB, thermostatic control, air filter and drain for condensing water. (b) Out door unit comprising . Compressor with motor,. air cooled copper condenser with fan and motor .unit shall be installed out side the building/ on roof. (c) Refrigerant copper pipe for suction and discharge line with insulation , condensing water drain pipe & protected by suitable size of flexible PVC conduit with control valves & safety accessories including control wiring for evaporator & condensing unit with suitable size of copper cable. (d) Making good the disturbed surface to match the existing surface after plugging the hole etc. (e) PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) as in plinth suitable for installation of outdoor unit or powder coated MS bracket fixed on wall as per Manufacture's instruction with necessary grouting MS hold fast, bolts, washers duly painted and making good to disturbed surfaces suitable for installing outdoor unit of 2 TR AC complete all as specified and directed. (f) Electrical cable required to connect outdoor unit and indoor unit to voltage stablizer inclusive in above rate.
Supply and fixing voltage stablizer electronic type for automatic operation single phase naturally air cooled, indoor type, wall mounted for input variation between 170 V to 280 V with output voltage stabilized at 200V to 245 V with accuracy of + 1% and of capacity 5.0 KVA complete all as specified and directed
Supply and fix sheet metal enclosure three pin, single phase, 240 volits with plug top, 20 Amp for split AC 1.5/2.0 TR complete all as specified and directed.
Supply and Fix, for MCCB , 4 pole 63 Amps 415 Volts all as specified and repturing capacity 25KA complete all as specified and as directed.
S&F MCB single pole 40 Amps ('B' Series) having current rating 10 kA, 240 V complete all as specified and as directed.
Excavation in trenches in hard / dence soil, not exc 1.5 m in width and not exc 1.5 m in depth for laying of cable lines etc and getting out including forming bottom surface, complete all as specifed and directed. NOTE :- (i) Contractor shall take written approval of entire route for excavation before commencing excavation work. (ii) Proper care shall be taken for existing underground services, pipe line / cable during execution. Any damage to the services done during the excavation will be resorted within 24 hrs at his own cost by the Contractor. (iii) For any delay beyond 24 Hrs for whatsoever reason, Penalty of Rs 1000/- per day will be levied upon the contractor.
Dismantling and taking down 03 Nos old unserviceable BER Hot blower units from SES bldg of capacity 1 x 30 KW with all equipments and accessories like filters , motor and including making good the disturbed PCC base surface as per existing as directed by Engr-in-charge. Note : Dismantled hot blower assembly shall be deposited to AGE (E/M) store yard for safe custody.
Supply ,installation ,testing & commissioning of Servo Voltage stabilizer for automatic operation, three phase naturally oil cooled indoor type & designed for input variation between 340 V to 460 V with output voltage stabilized at 415 with accuracy ± 2.5% and speed of correction 8 Volts per second and of capacity 100 KVA . The Voltage stabilizer shall conform to BID BIS 9815:Part1 :1994) with following specifications. i) Naturally Oil cooled ii) Indoor unbalanced type copper wound iii) 1st filling of Transformer oil of approved make ISI marked upto required level iv) Rated frequency 50 Hz v) No distortion in wave form vi) Response time not to exceed 20 mille seconds vii) Sensitivity (+/-)1% viii) Rate of correction 8 Volt/second for single phase and 13 V/seconds for phase to phase ix) Efficiency more than 95% x) Type of load : three phase , unbalanced type xi) Digital display Voltmeter/Ammeter Protection:- i) Over load/Short Circuit protections ii) High/Low voltage cut off iii) By pass arrangement in case of emergency iv) Single phase sequence change protection Note: i) Contractor to approve the drawings by th accepting officer before going for procurement. ii) Contractor to conduct all the Manufacurer factory and site tests as menioned in para 9 of BIS 9815 para 1 reaffirmed 2019 and tes reports in this this regard shall be forwarded. iii) The quoted price shall be inclusive of necessary PCC platform complete all as directed by the Engr-in-Charge.
Supply, installation, testing and commissioning of 03 Nos ,10,000.00 CFM Air blower double-skin type horizental floor mounted top discharge air handling units having corrosion resistant extruded aluminium hollow profile with thermal break heavy gauge galvanised steel channel base frame 25mm double skin panel with pressure injected CFC & HCFC free PUF with k value of 0.02 W / ⁰Cm & density 40kg/cum, pre-coated pre-plasticized glavinized outer and inner skin 0.60mm thick, air-tight casing gaskets and self adhesive tampers, AMCA certified energy efficient fans with double inlet double width forward or backward curved impellers for high static pressure mounted on aluminium extruded slide rail base frame, 10 micron pre-filters, inspection windows/doors, mixing box and supply/return dampers, 30 KW Strip Heaters complete all as specified and as directed.
RAVINDRA SALES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .