Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.6 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹34.5 L+₹2.5 L (7.81%)Rejected-Finance 32 GOLA MAHAL P O BARRACKPORE DIST NORTH 24 PARGANAS PIN 700 120 WB | 24 PARAGANAS NORTH | WEST BENGAL | 700120 | L2 | Rejected-Finance Not Being L1 | |
| 3 | L3₹43.3 L+₹11.3 L (35.4%)Rejected-Finance VILL KADUA PO HARIATARA DISTT PASCHIM MEDINIPUR WB PIN 721304 | HARIATARA | PASCHIM MEDINIPUR | WEST BENGAL | 721304 | L3 | Rejected-Finance Not Being L1 | |
| 4 | Rejected-Technical VILL PO KOTA VIA PANAGARH BAZAR DIST BURDWAN WB PIN 713148 | BURDWAN | BURDWAN | WEST BENGAL | 713148 | - | Rejected-Technical Not meet the NIT Criteria |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
19 Mar 2022, 6:00 pmClosed
MAJOR VIPIN BHATT
GE (AF) Kalaikunda PO Kalaikunda Air Field Dist Paschim Medinipore St West Bengal Pin 721303
REPAIR AND MAINTENANCE OF SUMMER AND COOLING APPLIANCES AND OTHER CONNECTED WORKS AND EARTHING PITS/LP,S AT TECH AREA AFS KKD AND DDK RANGE UNDER GE (AF) KALAIKUNDA
2022_MES_508893_1
8739/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AF STN KALAIKUNDA
As per tender documents
7 documents required · 7 mandatory
₹500
GE AF KALAIKUNDA
₹80,000
Yes
31 Mar 2022
17 Feb 2022
21 Mar 2022
17 Feb 2022
19 Mar 2022
4 Mar 2022
Amount
Comprehensive servicing for Window Type Air Conditioner of any make and capacity installed at various location by carrying out necessary repairs,cleaning of filters, adjustments of assemblies, sub-assemblies, check the level of refrigerant, arresting the leakage of any type, replacement of parts, calibration including cleaning of condensor & evaporator coils fins with mild detergent and descaling of condensor coil for window etc. through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved by GE, complete all as specified and as directed.
Comprehensive servicing for Split Type Air Conditioner of any make and capacity installed at various location by carrying out necessary repairs,cleaning of filters, adjustments of assemblies, sub-assemblies, check the level of refrigerant, arresting the leakage of any type, replacement of parts, calibration ncluding cleaning of condensor & eveporator coils fins with mild detergent and descaling of condensor coil for window etc. through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved by GE, complete all as specified and as directed. (NOTES:- (Applicable for BOQ Serial Item No. 1 to 2 here in before) (i)S&F spare parts will be measured and paid separately under relevant item.) (ii) The Contractor shall provide the following comprehensive services arising out of wear and tear of the normal running of Air Conditioners including maintenance of all mechanical, electrical and electronic parts /sub-assemblies. The preventive maintenance report will be as per the Original Equipment manufacturer's instructions and as specified in Particular Specification. (iii) Breakdown Maintenance : The Authorised Service Engineer of OEM or OEM Certified Agencies will carry out all breakdown maintenance after receiving information (written or oral) from GE (AF) KALAIKUNDA officials or their representatives, The OEM's authorised service representative or OEM certified agencies will carry out the required repairs of the units and appraise GE,Engineer-in-Charge and JE the status of the break down repair at site. No payment shall be made on account of any breakdown service during maintenence period including defect liablity period . (iv) The Service Engineer will be called in case of any breakdown and the same shall be attended within 24 Hours of lodging of complaint, failing which a penal recovery of Rs.200.00 (Rupees Two Hundred Only) per day till such time the unit is attended and complaint is resolved,will be recovered from the outstanding dues to the Contractor. (v) Cost of minor items like teflon tape,insulation tape, metal washers, fibre/rubber washers, screws, small nuts & bolts and like shall be deemed to be inclusive of the quoted rate. (vi) Spares required for replacement of defective ones will be measured and paid seperately .
M&L for Shifting of split type AC by taking out AC from MES yard or from existing location to the new location by taking it after taking down, closing the opening of old location with cement mortar cement mortor(1:3) ,white wash to match with the existing colour of the site & making holes in brick wall at new location and fine finishing with cement mortar white wash etc to match with the existing colour of the site installation & commissioning after replacement of insulation of suction & dischare line,charging,electrical connection only. Note:- (i) S&F insulation ,copper tube ,gas and other spare parts will be measured and paid separately under relevant items. (ii) Existing/ new location will be in Technical or Domestic area as per site requirement.)
M&L for Shifting of Window AC by taking out AC from MES yard or from existing location to new location & installation of window type AC by making necessary opening in brick wall/window for and preparing gap well finished by cement morter,white washing or as per existing specification to match with the existing colour, disposal of waste material, including covering of gap with ply wood and beeding work to cover the four side at front of AC & outer surface of plywood required to be painted with two coats of enamel paint over a coat of primer on plywood to match the existing location in all as directed by the Engr-in-charge. Note:- (i) S&F insulation ,copper tube ,gas and other spare parts will be measured and paid separately under relevant items. (ii) Existing/ new location will be in Technical or Domestic area as per site requirement.) Ply wood shall be measured and paid seperately.)
Supply and fixing in replacement of Printed Circuit Board suitable for 2TR Capacity Split Unit Air Conditioners including remote, as per OEMs specifications, complete suitable for existing type etc all as directed by Engr in charge .
Supply and fixing in replacement of Printed Circuit Board suitable for 1.5 TR Capacity Split Unit Air Conditioners including remote, as per OEMs specifications, complete suitable for existing type etc all as directed by Engr in charge .
S&F in repair Rotary compressor suitable for Split / Window AC of capacity 1.5 TR, suitable for R-22/R-32 gas, 220-240 volts, single phase, 50 Hz. as per OEMs specifications, complete all as specified and directed NOTES: (i) Repairs woks shall be carried out through authorised technicians of the OEMs as approved by GE.
S&F Rotary compressor suitable for Split / Window AC of capacity 2 TR suitable for R-22/R-32/R-410 gas, 220-240 volts, single phase, 50 Hz. as per OEMs specifications, complete all as specified and directed NOTES: (i) Repairs woks shall be carried out through authorised technicians of the OEMs as approved by GE.
S&F in repair Reciprocating compressor suitable for Split / Window AC of capacity 1.5 TR. suitable for R-22/R-32/R-410 gas, 220-240 volts, single phase, 50 Hz. as per OEMs specifications, complete all as specified and directed NOTES: (i) Repairs woks shall be carried out through authorised technicians of the OEMs as approved by GE.
S&F in repair Reciprocating compressor suitable for Split / Window AC of capacity 2 TR suitable for R-22 gas, 220-240 volts, single phase, 50 Hz. as per OEMs specifications, complete all as specified and directed NOTES: (i) Repairs woks shall be carried out through authorised technicians of the OEMs as approved by GE.
Supply & filling R-22 gas for Split AC/Window Type AC & other appliances all as specified and directed by Engr-in-Charge. (Contractor shall be check leakage in the system before filling of gas).
Supply & filling Nitrogen gas for vaccum for Split AC/Window Type AC & other appliances all as specified and directed by Engr-in-Charge.
Supply & filling R-32 gas for Split AC/Window Type AC & other appliances all as specified and directed by Engr-in-Charge.(NOTE:Contractor shall be check leakage in the system before filling of gas).
Supply & filling R-410 gas for Split AC/Window Type AC & other appliances all as specified and directed by Engr-in-Charge. (Contractor shall be check leakage in the system before filling of gas).
S& F Magneting Relay coil for AC's as per OEMs specifications, complete all as specified and directed NOTES: (i) Repairs woks shall be carried out through authorised technicians of the OEMs as approved by GE.
S&F Rubber bush for indoor motor of AC's as per OEMs specifications, complete all as specified and directed NOTES: (i) Repairs woks shall be carried out through authorised technicians of the OEMs as approved by GE.
S&F Potential relay suitable for Window type AC 1.5 /2.0 TR including taking down of defective relay as per OEMs specifications, complete all as specified and directed NOTES: (i) Repairs woks shall be carried out through authorised technicians of the OEMs as approved by GE.
S&F Air filter for Split type AC's ( suitable for AC of capacity 1.5/2 TR) as per OEMs specifications, complete all as specified and directed NOTES: (i) Repairs woks shall be carried out through authorised technicians of the OEMs as approved by GE.
M&L for rewinding/ repairing of blower fan motor of AC of capacity 1.5/2 TR Window AC by disconnecting the electrical connection of burnt out electric outdoor motor and dismantaling of parts, removing burnt out windings with insulating materials,cleaning throughly internally and externally, rewinding fan motor with super enamelled copper wires of existing size including provision of all insulating materials and varnishing, lubrication of bearing / bushes using fresh lubricant all as per OEMs reccommendations, replacement of defective parts,re-assembling, fixing in original position including testing and commissioning, complete all as specified and directed. NOTES:- (i) Repairs and rewinding woks shall be carried out through authorised technicians of the OEMs as approved by GE for motor of suitable capacity including removal and re-fixing of the same complete all as specified and dierected by the Engineer -in-charge.
M&L for rewinding/ repairing of blower fan motor of AC of capacity 1.5/2 TR Split AC by disconnecting the electrical connection of burnt out electric outdoor motor and dismantaling of parts, removing burnt out windings with insulating materials,cleaning throughly internally and externally, rewinding fan motor with super enamelled copper wires of existing size including provision of all insulating materials and varnishing, lubrication of bearing / bushes using fresh lubricant all as per OEMs reccommendations, replacement of defective parts,re-assembling, fixing in original position including testing and commissioning, complete all as specified and directed. NOTES:- (i) Repairs and rewinding woks shall be carried out through authorised technicians of the OEMs as approved by GE for motor of suitable capacity including removal and re-fixing of the same complete all as specified and dierected by the Engineer -in-charge.
Supplying and laying in replace of CPVC pipes SDR 11 & plain CPVC SDR 11 of 40 mm dia fittings with all fittings and fixed to walls or through walls / ceiling or laid in floors including cutting, chasing, including clamps and all fittings and fixtures complete all as specified.Make Supreme/Prince.
All as per item No-21 above but here in before but of size 25 mm dia. complete all as specified Make Supreme/Prince.
All as per item No-20 above but here in before but of size 20 mm dia. complete all as specified Make Supreme/Prince.
Supply and fixing in repair anti corrosive outdoor bracket for split type AC with aluminium hexagonal screws and all fittings as per OEMs specifications, complete all as specified and directed
S&F in repair Capacitor aluminium body 45 Mfd +6 450 VAC 50 HZ as per OEMs specifications, complete.Make - GC/Universal/Havells/Epcos/Tibcon
S&F in repair Capacitor aluminium body 55+4 Mfd 450 VAC 50 HZ as per OEMs specifications, complete.Make - GC/Universal/Havells/Epcos/Tibcon
S&F in repair Capacitor aluminium body 45+4 Mfd 450 VAC 50 HZ as per OEMs specifications, complete.Make - GC/Universal/Havells/Epcos/Tibcon
S&F in repair Capacitor aluminium body 60+6 Mfd 450 V AC 50 HZ as per OEMs specifications, complete.Make - GC/Universal/Havells/Epcos/Tibcon
S&F in repair Capacitor aluminium body 60+4 Mfd 450 V AC 50 HZ as per OEMs specifications, complete.Make - GC/Universal/Havells/Epcos/Tibcon
S&F in repair Capacitor aluminium body 36 MFD ±5%, 440V, AC, 50 Hz including taking down of defective capacitor as per OEMs specifications, complete.Make - GC/Universal/Havells/Epcos/Tibcon
S&F in repair Capacitor aluminium body 50 Mfd 450 V AC 50 HZ as per OEMs specifications, complete.Make - GC/Universal/Havells/Epcos/Tibcon
S&F in repair Capacitor aluminium body 45 Mfd 450 V AC 50 HZ as per OEMs specifications, complete.Make - GC/Universal/Havells/Epcos/Tibcon
S&F Capacitor aluminium body 36 MFD, 440V AC 50 Hz including taking down of defective capacitor as per OEMs specifications, complete.Make - GC/Universal/Havells/Epcos/Tibcon.
S&F in repair Capacitor aluminium body 50 Mfd +6 450 V AC 50 HZ as per OEMs specifications, complete.Make - GC/Universal/Havells/Epcos/Tibcon
S&F in repair Capacitor aluminium body 4 Mfd ±5% 440 V AC 50 HZ as per OEMs specifications, complete.Make - GC/Universal/Havells/Epcos/Tibcon
S&F in repair Capacitor PVC 1.5 Mfd rectangular type,±5% 440 V AC 50 HZas per OEMs specifications, complete.Make - GC/Universal/Havells/Epcos/Tibcon
S&F in repair Capacitor of capacity 3.15mfd,±5% 220V,AC as per OEMs specifications, complete.Make - GC/Universal/Havells/Epcos/Tibcon
S&F in repair Capacitor of capacity 2mfd,±5% 220V ,AC as per OEMs specifications, complete.Make - GC/Universal/Havells/Epcos/Tibcon
S&F in repair Capacitor 70 Mfd +6 450 V AC 50 HZ as per OEMs specifications, complete.Make - GC/Universal/Havells/Epcos/Tibcon
S&F in repair Starting capacitor 80/100 mfd, 440 V AC, as per OEMs specifications, complete.Make - GC/Universal/Havells/Epcos/Tibcon
S&F in repair Starting capacitor 100/120 mfd, 440 V AC,as per OEMs specifications, complete.Make - GC/Universal/Havells/Epcos/Tibcon
S&F in repair Strainer (capillary) two way/single way as per OEMs specifications, complete.
Supply & fixing in repair blower motor, 220-240 V, 50 HZ,30-80Watt(as per existing), 4 pole insulation class -B, IP22 as per sample suitable for window AC of any make and 1.5/2 TR capacity.(Contractor shall provide the new motor of reccommended make of OEM of AC in which it has to be fixed, Make of AC : LG/Carrier/Samsung/Amtrex / Videocon / Hitachi/ Blue star any make. Before procurement he will take the approval from Engr-in-Charge for make and model.
S&F Condenser coil copper size of 20x32 for suitable for Split type AC 1.5 /2.0 TR. including taking down of defective coil as per OEMs specifications, complete.
S&F Condenser coil copper size of 22x32 for suitable for Split type AC 1.5 /2.0 TR. including taking down of defective coil as per OEMs specifications, complete.
S&F in repair Condenser coil copper for suitable for Window type AC 1.5 /2.0 TR. as per OEMs specifications, complete.
S&F in repair Fan Blade suitable for Window AC type AC 1.5 /2.0 TR as per OEMs specifications, complete.
S&F in repair Fan Blade suitable for Split type AC outdoor 1.5 /2.0 TR as per OEMs specifications, complete.
Supply & fixing in repair blower motor, 220-240 V, 50 HZ,30-80Watt(as per existing), 4 pole insulation class -B, IP22 of indoor unit as per sample suitable for Split type AC of any make and 1.5/2 TR capacity.(Contractor shall provide the new motor as per OEMs specifications, complete. Make of AC : LG/Carrier/Samsung/Amtrex / Videocon / Hitachi/ Blue star . Before procurement he will take the approval from Engr-in-Charge for make and model.
S & F in repair single pole and neutral enclosure with two pin and earth, plug and socket , suitable for single phase 240 V,complete with one single pole MCB of capacity 20 amps having `C` charactristic, breaking capacity 10 KA, including industial plug top, complete all as specified and as directed. Make : Legrand cat part No. 607841 or equivelent in Schinder/ L&T.
S&F 20 Amp three pin top metal clad suitable for industrial socket including taking down of defective top complete all as specified and directed. Make-Havells (Crabtree)/Anchor/Legrand.
Supply & fixing in repair blower motor, 220-240 V, 50 HZ,30-80Watt(as per existing), 4 pole insulation class -B, IP22 of outdoor unit as per sample suitable for Split type AC of any make and 1.5/2 TR capacity.(Contractor shall provide the new motor as per OEMs specifications, , Make of AC : LG/Carrier/Samsung/Amtrex / Videocon / Hitachi/ Blue star any make. Before procurement he will take the approval from Engr-in-Charge for make and model.
S&F in repair Remote suitable for split type AC 1.5/2 TR indoor unit as per OEMs specifications,
Comprehensive maintenance as per Original Equipment Manufacturer's (OEMs) reccommendations Water Cooler of any make and capacity installed at various locations by carrying out necessary repairs, adjustments of assemblies, sub-assemblies, check the level of refrigerant, arresting the leakage of any type, replacement of parts, calibration etc. through OEMs Authorised Service Centre Engineers or through OEMs Certified Agencies as approved by GE, including refixing the same at the location where directed including making/connecting of water and electric connection complete all as specified and dierected. Make of water cooler : Voltas/Bluestar/Shriram/Videocon or any make.
S&F Compressor for water cooler as per sample including taking down of defective compressor of any make and capacity installed at various locations through OEMs Authorised Service Centre Engineers or through OEMs Certified Agencies as approved by GE, including refixing the same at the location where directed including making/connecting of water and electric connection complete all as specified and dierected. Make of water cooler : Voltas/Bluestar/Shriram/Videocon or any make.
Supply & fixing in repair Potential relays suitable for Water cooler of any make and capacity as per OEMs specifications,
S&F in repair motor assembly of 220-240 V, 50 HZ,30-80Watt(as per existing), 4 pole insulation class -B, IP22 of as per sample suitable for suitable for Water cooler of any make .(Contractor shall provide the new motor as per OEMs specifications, in which it has to be fixed, Make of water cooler : Voltas/Bluestar/Shriram/Videocon or any make. Before procurement he will take the approval from Engr-in-Charge for make and model.
S&F in repair Door Gasket suitable for Water cooler of of any make and capacity as per OEMs specifications,
S&F in repair Magnetic relay suitable for Water cooler of any make or capacity. as per OEMs specifications,
S&F in repair Thermostat switch complete suitable for Water cooler of any make and capacity as per OEMs specifications,
S&F in repair Connection pipe suitable for Water cooler of any make and capacity as per OEMs specifications,
S&F in repair Push Tap suitable for Water cooler of any make or capacity.as per OEMs specifications.
S&F in repair Drain pipe for suitable for Water cooler of any make and capacity as per OEMs specifications.
S&F in repair Chromium plated L type/push type self closing tap of stainless steel of any make and capacity as per OEMs specifications,
S&F in repair Capacitor aluminium body 6 Mfd ±5% 440 V AC 50 HZ as per OEMs specifications, Make -GC/Universal/Havells/Epcos/Tibcon
S&F in repair Capacitor of capacity 10mfd,±5% 220VAC as per OEMs specifications, Make -GC/Universal/Havells/Epcos/Tibcon
S&F in repair Capacitor of capacity 12mfd,±5% 220VAC as per OEMs specifications, Make -GC/Universal/Havells/Epcos/Tibcon
Comprehensive maintenance as per Original Equipment Manufacturer's (OEMs) reccommendations 165 to 340 Litres capacity refrigerators installed at various locations by carrying out necessary repairs,adjustments of assemblies, sub-assemblies, check the level of refrigerant, arresting the leakage of any type, replacement of parts, calibration etc. through OEMs Authorised Service Centre Engineers or through OEMs Certified Agencies as approved by GE, complete all as specified and directed. [Make: LG/Voltas/ Godrej/Kelvinator/ Whirlpool/Blue Star]
Supply & fixing in repair Condenser coil suitable for Refrigerator of any make and capacity as per OEMs specifications
S&F in repair Cooling coil with door and frame suitable for Refrigerator of any make and capacity of any make and capacity as per OEMs specifications
S&F in repair Thermostat switches suitable for Refrigerator of any make and capacity:of any make and capacity as per OEMs specifications
S&F in repair Gasket set complete suitable for Refrigerator of any make and capacity of any make and capacity as per OEMs specifications
S&F in repair Chiller tray suitable for Refrigerator of any make and capacity:Make - as per sample. Make - as per sample
S&F in repair Potential relay suitable for Refrigerator of any make and capacity of any make and capacity as per OEMs specifications
S&F in repair Drier suitable for Refrigerator of any make and capacity of any make and capacity as per OEMs specifications
S&F in repair Bulb thread/pin type suitable for Refrigerator of any make and capacity of any make and capacity as per OEMs specifications
S&F in repair Bi-Metal with timer suitable for Double door Refrigerator of any make and capacity as per OEMs specifications
S&F in repair Grills for keeping products suitable for Refrigerator of any make and capacity as per OEMs specifications
S&F in repair Compressor suitable for refrigerator 1/8 as per OEMs specifications through OEMs Authorised Service Centre Engineers or through OEMs Certified Agencies as approved by GE, complete all as specified and directed.
S&F Tray for keeping products suitable for Refrigerator of any make and capacity including taking down of defective tray per OEMs specifications through OEMs Authorised Service Centre Engineers or through OEMs Certified Agencies as approved by GE, complete all as specified and directed.
S&F in repair Compressor suitable for refrigerator 1/6 as per OEMs specifications through OEMs Authorised Service Centre Engineers or through OEMs Certified Agencies as approved by GE, complete all as specified and directed.
Comprehensive maintenance as per Original Equipment Manufacturer's (OEMs) reccommendations of any capacity and make Deep Freezer installed at various locations by carrying out necessary repairs, adjustments of assemblies, sub-assemblies, check the level of refrigerant, arresting the leakage of any type, replacement of parts, calibration etc. through OEMs Authorised Service Centre Engineers or through OEMs Certified Agencies as approved by GE, complete all as specified and directed. NOTES:- (Applicable for BOQ Serial Item No. 54 to 85 here in before and here in after ) (i) The Contractor shall provide the following comprehensive services arising out of wear and tear of the normal running of Refrigerator/Deep Freezer/Water Cooler. (ii) Preventive and Corrective Maintenance This includes maintenance of all mechanical, electrical and electronic parts /sub-assemblies. The preventive maintenance report will be as per the Original Equipment Manufacturer's instructions and as specified in Particular Specification. (iii) Breakdown Maintenance : The Authorised Service Engineer of OEM or OEM Certified Agencies will carry out all breakdown maintenance after receiving information (written or oral) from officials or their representatives.The OEM's authorised service representative or OEM certified agencies will carry out the required repairs of the units and appraise GE, Engineer-in-Charge and JE the status of the break down repair at site. No payment shall be made on account of any breakdown service to the machinary/equipments during comprehensive maintenence period. The Service Engineer will be called in case of any breakdown and the same shall be attended within 24 Hours of lodging of complaint, failing which a penal recovery of Rs.200.00 (Rupees Two Hundred Only) per day till such time the unit is attended and complaint is resolved,will be recovered from the outstanding dues to the Contract (v) Cost of minor items like teflon tape,insulation tape, metal washers, fibre/rubber washers, screws, small nuts & bolts and like shall be deemed to be inclusive of the quoted rate. (vi) Spares required for replacement of defective ones will be measured and paid seperately
Supply & fix in repair Condensor Motor suitable for Deep freezer of any make and capacity as per OEMs specifications
Supply & fix in repair Condensor coil for deep freezer as per OEMs specifications
Supply & fix in repair Fan Blade for deep freezer as per OEMs specifications
Supply & fix in repair Compressor suitable for Deep freezer as per OEMs specifications
Attending complaints of Geyser of any capacity any type from exiting position for checking of heating element, thermostat, and all accessories removing defected parts and re-assembling the same and refixing to its existing location with testing for its proper functioning complete all as specified and directed by Engr-in-charge. NOTE :1 Complaints should attend within 24 hrs after receipt of complaints from JE E/M. 2 If any spares required then supplied and measured separately under relevant item.
Taking down of Geyser of any capacity any type from exiting position for descaling, removing its accessories removing the scale (white presipated) deposited in it, cleaning the inner tank properly, painting with sparay gun and re-assembling the same and refixing to its existing location with testing for its proper functioning complete all as specified and directed by Engr-in-charge. NOTE : If any spares required then supplied and measured separately under relevant item.
Supply only inner container brass suitable for vertical type geyser 50 ltrs storage capacity including taking down of defective container as per OEMs specifications complete all as specified and directed.
All as per item No above here in before but 25 Ltr Capacity complete all as specified and directed.
S & F in repair Thermostat 0-80 Degree as per exiting size as per OEMs specifications including taking down of defective thermostat complete all as specified and directed
S & F in repair Heating element 1.5 KW, as per OEMs specifications all as specified and directed
S & F in repair Heating element 2 KW, as per OEMs specifications all as specified and directed
S & F in repair Indicator lamp with flexibe copper wire of suitable size Red/Green including taking down of defective indicator lamp complete all as specified and directed.
S & F PVC Connection with steel reinforced pipe for hot water connection of Size 18" x 1/2" including rubber washers including taking down of defective blade complete all as specified and directed
S & F Copper Apperture plate suitable for 25/50 ltrs geyser along with rubber gasket, nuts, bolts,etc as per OEMs specifications including taking down of defective apparture plate complete all as specified and directed
M&L for complete servicing of solar hot water system (solar water heater, flate plate collector type), with cleaning of sluge deposited in pipe line of solar pannel by using cleaning regent, check and repair of pipe line for any leakage, including carring out brazing of copper pipe for leakage, cleaning of glass shell, cleaning of hot water tank, replacement of u/s clamps, adopter, hose pipe including filling of distilled water and coolent in reservior including complete sevicing to keep the plant functional of capacity up to 200 LPD through OEMs Authorised Service Centre Engineers or through OEMs Certified Agencies as approved by GE, complete all as specified and directed
Supply only Distilled water complete all as specified and directed.
M&L in repair for replacement of thermostate, long body, ISI marked of solar water heater of cap up to 200 LPD including taking down of defective thermostate through OEMs Authorised Service Centre Engineers or through OEMs Certified Agencies as approved by GE, complete all as specified and directed
M&L in repair for replacement of electrical heating element of 2.0 KW ISI marked (long thread type, as per existing), ISI marked, of solar water heater of cap up to 200 LPD including taking down of defective element complete all as specified and directed. Make: Solar Element or equivalent make as approved by GE
M&L for replacement in repair hot water pipe insulation with glass wool and aluminium cladding 20 mm bore including all material complete as per OEM recommendation complete all as specified and directed
Supplying & fixing to walls , floor and ceiling 40 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 with and including taking down existing unserviceable complete all as specified and as directed.
All as per item No.103 above herein before but of size 25 mm bore complete all as specified and as directed.
All as per item No.103 above herein before but of size 20 mm bore complete all as specified and as directed.
All as per item No.103 above herein before but of size 15 mm bore complete all as specified and as directed.
S & F Stop valves, 20mm cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as directed by Engr-in-charge.
All as per item No above herein before but t fancy type, chromium plated with long shank and cup (concealed type) complete all as specified and as directed.
S &F 15mm bore Gun-metal, globe or gate valves,with iron wheelhead, screwed both ends for ironpipe and fixed complete all as directed by Engr-in-charge.
S & F 25mm bore Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed including taking down complete all as directed by Engr-in-charge.
S & F rotational moulded polyethylene double layer water tanks (vertical cylindrical with close top) as per IS 12701: 1996 of 500 litres capacity hoisted and fixed in position including provision of 20 mm /15 mm dia medium grade GI pipe for connecting inlet, outlet, over flow and washout pipes all as specified and as directed.
S & F rotational moulded polyethylene double layer water tanks (vertical cylindrical with close top) as per IS 12701: 1996 of 300 litres capacity hoisted and fixed in position including provision of 20 mm /15 mm dia medium grade GI pipe for connecting inlet, outlet, over flow and washout pipes all as specified and as directed.
S & Fix solar collector plate panel as per including taking down through OEMs Authorised Service Centre Engineers or through OEMs Certified Agencies as approved by GE, complete all as specified and directed
Material and labour for sub main wiring wth 2 runs of 4 sq. mm. (Phase & Neutral ) and one run of 4Sq. mm. for earth contunity conductor PVC insulated unsheathed FRLSH grade cable with copper conductors multi stranded 1100 V grade confirming to IS-694 drawn through and including surface PVC casing caping of suitable size, with accessories all as specified and as directed by Engineer -in-charge. NOTE:- (a) 2 runs of 4 Sq.mm. + 1 run of 2.5 Sq.mm. cable for earth + 1 run of casing caping shall be measured as one unit leangth
M&L for point wiring one 3 pin socket ,15 Amps, Independent, with cable 4 sq mm size single core multi standered FR grade copper conductor unshethed PVC insulated 1100V grade cable drwan into and including PVC casing caping with accessories and fitting like bend, elbows, crosses wall crossing etc. with sunken type pressed steel box width 3mm thick plastic laminated sheet top cover of approved make for housing switches, sockets outlet and regulators and with continueus 1 No cable 4 Sq.mm. stranded copper conductor PVC insulated, unshethed FR grade as earth wire connected to earth dolly and to be cconnected boxes of suitable sizes for mounting to fittings etc, with necessary cutting / chasing of wall/ ceiling complete all as specified and as directed for one light point controlled by one switch.
Supply & fixing in repair flexible PVC Water drain pipe suitable for Split AC (upto 5/8 PVC pipe) as per OEMs specifications
S&F in repair Copper refrigerent piping size 1/4" suitable for cooling appliances as per OEMs specifications
S&F in repair Copper refrigerent piping size 1/2" suitable for cooling appliances as per OEMs specifications
S&F in repair Copper refrigerent piping size 5/8" suitable for cooling appliances as per OEMs specifications .
S&F in repair Copper refrigerent piping size 3/8" suitable for cooling appliances.as per OEMs specifications
S&F in repair Capillary tube suitable for cooling appliances as per OEMs specifications
S&F in repair MCB SP 240 volts 6 to 32 Amps, 10 KA breaking capacity, 'C' Curve including connection with suitable size copper lugs complete all as specified and directed by Engr-In-Charge.
Supply only Soldering stick superior quality as per OEMs specifications
S&F in repair PVC insulated PVC sheathed 2.5 sqmm Size 3 core copper cable complete all as specfied and directed . Make:-Havells/Plaza/ Finolex.
S&F in repair temperature sensor suitable for cooling appliances as per OEMs specifications complete all as specified and directed .
S&F in repair PVC insulated PVC sheathed 0.75 sqmm copper cable including taking down complete all as specified and directed by Engr -in-Charge. Make:-Havells/Plaza/ Finolex.
S&F in repair PVC insulated PVC sheathed 0.50 sqmm copper cable including taking down complete all as specified and directed by Engr -in-Charge . Make:-Havells/Plaza/ Finolex.
S&F in repair Nitrile Rubber insulation for AC pipe of size 5/8" as per OEMs specifications complete all as specified and directed
S&F in repair Nitrile Rubber insulation for AC pipe of size 1/4".as per OEMs specifications complete all as specified and directed
S&F in repair Flare Nut of any size (upto 1 inch) as per OEMs specifications complete all as specified and directed
S&F in repair Overload Protector as per OEMs specifications complete all as specified and directed
Supply & charging 134A gas to maintain the required cooling effect as and when required in the Water cooler/Refrigerator charging (Charging costincluding in this item.)
M&L LPG butane gas cartridge of capacity 230 gm for soldering as per OEMs specifications
S&F in repair overload relay for water cooler of any capacity and make as per OEMs specifications
S&F in repair overload relay for Refrigerator of any capacity and make as per OEMs specifications
S&F in repair for Non return valve for charging gas of any capacity and make as per OEMs recommendation complete all as specfied and directed
M&L for repair of PCB Kit for AC/Water cooler/Refrigerator of any capacity and make as per OEMs specifications complete all as specfied and directed
S&F in repair Drain pipe for split type AC indoor unit of any capacity and make as per OEMs specifications complete all as specfied and directed
S&F in repair PVC plug top 15 Amps, single phase, 240 Volts.of any make as per OEMs specifications complete all as specfied and directed
S&F in repair PVC plug top 5 Amps, single phase, 240 Volts.of any make as per OEMs specifications complete all as specfied and directed
Supply and fixing in wooden ply 6mm ISI marked suitable complete all as specfied and directed
Attending of complaints of summer appliances ie, ACs, water cooler, Refrigerator, Deep Freezor, Walk in cold storage, VRF ACs, etc deploying experienced air condition / refrigeration mechanic and helper and rectification of complaints to th entire satisfaction of Engineer-In-Charge and users. Note:-(i) For rectification of complaints if any spares, gas etc required to be replaced the same shall be measured and paid seperately under "supply and fixing" items. (ii) Mechanic engaged by contractor for attending complaints and rectification there of, shall carry the required job card, which shall be supplied by contractor at his own cost. (iii) Sufficient mechanic and staff shall be engaged by contractor in order to rectify the all complaints with in 24 hrs on all working days as well as holidays as given by the Dept.If contractor fails to attend/rectify the complaints within 24 hrs he shall be panalised for Rs. 100 Per complaints. Note for Item No.1 to 142:- i) Being maint contract site will be hand over to contractor as per complaint received from user and as per site requirement. (ii) Contractor trade man should report to AC section daily and take complaints from concern JE E/M and after attending complaint he will give feedback and return complaint slip to concern JE E/M in the evening at 17.30 Hrs on same day.
Taking down old unserviceable GI/Copper earth plate or Chemical earthing from soft and hard soil from any location as directed by Engineer -in- charge.
M&L for Advance encapsulated compound based Chemical earthing CPRI tesed maintenance free , pipein -pipe technology upgraded (Zinc & Alloy coated). , Zinc & Alloy coated (80 -100) microns with pure zinc (99.9%) & Alloy coating (200-250) microns. Earthing system conforming IS 3034. The outer and inner pipe should be 76.2 mm and 41.9 mm dia respectively of 3 mtrs long zinc coated with additional special alloy coating 300 mm on top side for additional protection of the terminal . The annular space between the pipes to be filled up with Compact fill (CF) (Crystalline Conductive) mixture which should be machine pressed in the pipes not disintegrate or collapse when outer pipe corrodes . The inner pipe should be extended with terminals for connectivity.The job includes digging the pits in any type of hard dense soil of min size 1000 X 1000 X 3050 mm depth taking out excavated soil, lowering/ placing the the pipe in pipe earth electrode in pit in center ,filling of pure conductolite back filling compound (BFC Conductolite ) having excellent moisture retaining capacity in 300 mm around the electrode (minimum 4 bags of 25 KG per pit per unit) or more qty of backfill compound as required to fill around the the elctrode in 300 mm in circumfrance of electrode . Contractor has to fill the remaining portion of pit with low resistivity soil (agriculture soil) free from stones etcs, to be bring from out side defence land as the soil resistivity of Stn is very high and mixed with min 3 Bags of 50 Kg each of Bantonide clay. The BFC should be eco friendly it should not contain envernmently hazardous material/metal having ROHS certification from NABL accredited lab.The earth pit should be provided with a FRP earth pit cover for protection and safe guard of terminals. The material of earth electrode should have good electrical conductivity & anti corrosion property in wide range of soil conditions. The job also include M & L for in PCC(1:3:6) type C-1 around the FRP cover for support and foundation and colouring the PCC work with desired colour.complete all as specified and directed. Make : ELMECH (ASHLOK ( Model ASEEL-39 AC 03 mtr length 76.2 mm outer dia and 38.1 mm inner dia. or equivalent make as approved by GE) Note : (i) Design of earth electrode should be of pipein-pipe technology . (ii) Contractor have to submit literature of earth electrode and get the make approved of GE before procurement. (iii) The earth electrode shall be CPRI tested to withstand short current test for 60kA rms for 1.0 second and 150kA for peak current. (iv) Contarctor has to fill pure back fill compound conductolite all around the earth electrode in 300 mm bore up to full depth of bore. (v) Contractor shall refill the pit with low resistivity soil (agriculature soil ) free fron stone etc and mixed with 06 bags of Bentonite of 25 Kg each to achive the low resistance values. (vi) copper strip will be laid below 60 cm from ground level and connected to test point through plinth protection (vii) Necessary cost of repair to plinth protection and connected plate and earth continuity conductor by providing 2 x brass nuts bolts and brazing of joints, bringing argiculture soil from out side defence land and cost of 6 x Bags of bentonide deemed to be included in the item rate. (viii) Contractor has to clear the side and disposed off the excavated soil from pit on completion of work.
M&L for Advance encapsulated compound based Chemical earthing CPRI tesed maintenance free , pipein -pipe technology upgraded (Zinc & Alloy coated). , Zinc & Alloy coated (80 -100) microns with pure zinc (99.9%) & Alloy coating (200-250) microns. Earthing system conforming IS 3034. The outer and inner pipe should be 76.2 mm and 41.9 mm dia respectively of 3 mtrs long zinc coated with with additional special alloy coating 300mm on top side for additional protection of the terminal . The annular space between the pipes to be filled up with Compact fill (CF) (Crystalline Conductive) mixture which should be machine pressed in the pipes not disintegrate or collapse when outer pipe corrodes . The inner pipe should be extended with terminals for connectivity.The job includes boring of 300 mm dia bore up to 5.5 mtr depth in rocky strata for placing / lowering the pipe in pipe electrode , filling of pure conductolite back filling compound (BFC Conductolite ) having excellent moisture retaining capacity in 300 mm bore all around the electrode min 4 bags of 25 KG per pit per unit) or more qty of backfill compound as required to fill around the the elctrode in 300 mm in circumfrance of electrode .The earth pit should be provided with a FRP earth pit cover for protection and safe guard of terminals. The material of earth electrode should have good electrical conductivity & anti corrosion property in wide range of soil conditions. The job also include M & L for in PCC(1:3:6) type C-1 around the FRP cover for support and foundation and colouring the PCC work with desired colour.complete all as specified and directed. Make : ELMECH (ASHLOK ( Model ASEEL-39 AC 03 mtr length 76.2 mm outer dia and 38.1 mm inner dia.) Note : (i) Design of earth electrode should be of pipein-pipe technology . (ii) Contractor have to submit literature of earth electrode and get the make approved of GE before procurement. (iii) The earth electrode shall be CPRI tested to withstand short current test for 60kA rms for 1.0 second and 150kA for peak current. (iv) Contarctor has to fill pure back fill compound conductolite all around the earth electrode in 300 mm bore up to full depth of bore. (v) Copper strip will be laid below 20 cm from ground level and connecting the test point through plinth protection using HDPE pipe for protection, necessary cost of repair to plinth protection and brazing and welding deemed to be included in the item. (vi) Contarctor shall submit the test report of earthing after satisfactorily completion. (vii) Contractor shall remove and disposed off the soil excavated from boring and clear the site before completion of work.
M&L earthing complete with copper earth plate electrode 600 mm x 600 mm x 3 mm thick burried directly in ground (Earth pit not less than 4 mtr deep below ground level) with top edge of the plate not less than 3.25 mtr below ground level connected to copper strip 20 x 3 mm as earth lead by brass nut bolts washer including brazing the copper strip with copper plate as shown in electrical plate No 3 connected to earth test point including necessary excavation in hard dense soil / disintergate rock, filling charcoal and salt around the plate in layers , filling the pit with agriculture soil free from stones, to be bring from out side defence land and mixed with Bentonite (3 bags of 25 Kg each ), construction of inspection pit of brick work of size 600 x 600 x 600 mm with PCC copping of 1 :2: 4 , 12.5 mm aggregate A1 with MS sheet 3 mm plate cover on frame of angle iron of size 40 x 40 x 5 mm with , wire mess, funnel, test point, 40 mm dia GI protection pipe light grade and 32 mm GI peforated pipe for watering etc complete and testing on completion. The electrode and lead shall be of copper all as specified and directed by Engr-in-charge (Copper strip upto 7.5 RM will be included in the item rate and copper strip beyond 7.5 RM will be measured seperately (Note : (i) Contractor shall use Fresh agriculture soil , mixed with 3 x Bags of bentonide of 25 Kg each for refilling the pit to achive the desired resistance. (ii) copper strip will be laid below 60 cm from ground level and connected to test point through plinth protection (iii) Necessary cost of repair to plinth protection and connected plate and earth continuity conductor by providing 2 x brass nuts bolts and brazing of joints, bringing argiculture soil from out side defence land and cost of 3 x Bags of bentonide deemed to be included in the item rate. (iv) Contractor has to clear the side and disposed off the excavated soil from pit on completion of work.
Taking out old unserviceable GI/aluminium/copper earth strip or for relaying/ refixing the same existing strip by providing procline insulators of any size and type in any height and any location as directed by Engineer In charge.
Supply and fixing copper strip of size 20 x 3 mm as earth continuity conductor or main earthing lead fixed on "V" type porcelain insulator, 4 BM, heavy duty ( ceramic bus bar support insulator off white colour of suitable for mounting strip of 20 mm wide x 3 min thick) saddle to wall, buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 20 x 3 mm copper strip brazing to each joints and connected with by providing brass nut bolts and washer all as specified and directed by Engr in Charge. Note : Insulators to be provided on every 50 cm. (Minimum 2 x insulators to be provided in every 1 x metre of strip)
Supply and fixing copper strip of size 32 x 6 mm as earth continuity conductor or main earthing lead fixed on "V" type porcelain insulator 10 BM heavy duty ( ceramic bus bar support insulator off white colour of min size of 36 mm width x 60 mm length with 36 mm width bus bar mounting base) saddle to wall, buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 20 x 3 mm copper strip brazing to each joints and connected with by providing brass nut bolts and washer all as specified and directed by Engr in Charge.Note : Insulators to be provided on every 50 cm. (Minimum 2 x insulators to be provided in every 1 x metre of strip)
Supply and fixing copper strip of size 50 x 6 mm as earth continuity conductor or main earthing lead fixed on "V" type porcelain insulators, 10 BM heavy duty ( ceramic bus bar support insulator off white colour of min size of (ceramic bus bar support insulator off white colour of min size of 50 mm width x 70 mm length with 50 mm width bus bar mounting base)) saddle to wall, buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for earthing etc. as required 50 x 6 mm copper strip brazing to each joints and connected with by providing brass nut boltsand washer all as specified and directed by Engr in Charge. Note : Insulators to be provided on every 50 cm. (Minimum 2 x insulators to be provided in every 1 x metre of strip)
Supply and fixing aluminium strip of size 25 x 3 mm as earth continuity conductor or main earthing lead fixed on "V" type porcelain insulators, 4 BM, heavy duty ( ceramic bus bar support insulator off white colour of suitable size for mounting strip of 20 mm wide x 3 min thick)) saddle to wall, buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required and connected with by providing brass nut bolts and washer all as specified and directed by Engr in Charge. Note : Insulators to be provided on every 50 cm. (Minimum 2 x insulators to be provided in every 1 x metre of strip)
M & L for Refixing of existing serviceable copper / aluminium / GI strip taken out under above, on top of "V" type procelain insulator ( ceramic bus bar support insulator off white colour of suitable size for mounting of insulator) fixing strip on insulator with brass nuts and bolt ,screws, aluminium cleats etc.( Procelain insulator if replaced shall be measured separetly) duly straightened properly and fixing in neat dressed manner as directed by Engineer in charge. Note: (i) Procelain insulator to be measured and paid seperately under relevant item
M& L for porcelain insulater 10 BM heavy duty (ceramic bus bar support insulator off white colour of min size of 50 mm width x 70 mm length with 50 mm width bus bar mounting base for fixing strip of width above 32 mm to 50 mm fixing on wall for supporting the copper strip including suitable size brass nuts and bolts, washers, drilling hole on wall to fix porcelain insulator , fixing insulator by providing steel screws etc complete all as specified and directed by Engineer-in-charge.( Note : Cost of brass nut bolt and washer and steel screw for fixing insulator is deemed to be included in unit rate of item).
M& L for porcelain insulater 4 BM heavy duty (ceramic bus bar support insulator off white colour of min size of 36 mm width x 60 mm length with 36 mm width bus bar mounting base for fixing strip of width up to 32 mm fixing on wall for supporting the copper strip of size 20 x 3 mm and up to 32 mm width including suitable size brass nuts and bolts, washers, drilling hole on wall to fix porcelain insulator , fixing insulator by providing steel screws etc complete all as specified and directed by Engineer-in-charge. ( Note : Cost of brass nut bolt and washer and steel screw for fixing insulator is deemed to be included in unit rate of item).
M&L for carrying out brazing work of copper earth strip joints, after removing the nut bolt, scraping and cleaning the strip surface all as specified by Engr-in-charge. Note : Size of earth strip is 20 x 3 mm to 25 x 3 mm
S&F for thermoplastic(polycarbonate) junction box for test point without terminal block of dimension 130 x 180 x 77 mm IP 66 halogen free and weather proof including four hexagonal anticorrosive screws for out door installation including taking down unserviceable one. Make : Hensel- Cat part No. KF 0600 H or as equivalent in Sintex or equivalent make as approved by GE.
M&L in repair for Test point terminal block made of gun metal or phosphorus bronze size 75 x 75 x 25 mm drilled and screwed incl 3 Nos 8mm dia 25mm long hexagonal head screws for fixing strips to test point including necessary fixing arrangement to fix test point terminal block in junction box all as specified and directed. including taking down unserviceable one.
Supply & Fixing hexagonal head brass nut bolt and washer (Bolt size not less than 30 mm long from under side of head to end and not less than 6 mm dia) as specified and directed by Engr-in -charge.
Supply & Fixing hexagonal head brass nut bolt and washer (Bolt size not less than 50 mm long from under side of head to end and not less than 7 mm dia) as specified and directed by Engr-in -charge.
Taking down old broken and damaged earth pit chamber and M & L for construction of new earth pit chamber of brick work with plaster in outer and inner surface , copping of of PCC 1:2:4 Type A-1. Earth pit shall be of size 600 x 600 x 600 mm embedded in ground below GL 150 mm with openable cover made up of MS sheet of minimum 2.8 mm thickness fixed in angle iron frame and handle including GI funnel and wire mesh , including painting the complete pit with two coat of synthetic enamel paint as per colour code all as specified and directed by Engineer-in-charge. Colour to be painted on complete pit to be obtain from Engr in Charge.
M & L in repair Air termination, single pointed, aluminium rod 12mm dia and 300mm long complete fixed on wall/roof including fixing arrangement all as specified and directed..
M & L in repair Air termination, single pointed, copper rod 12mm dia and 300 mm long complete fixed on wall/roof including fixing arrangement all as specified and directed..
Supply & laying of UPVC pipe of size 25 mm dia for protection of copper earth strips complete all as specified and directed by Engineer -in-charge
M & L for fabrication of display board for earth pit nos, lacation and periodical test results for power circuit earthing, machinary earthing ,lightening conductor earthing, made of MS sheet 3.0 mm thick sheet, rectangular welding on angle iron of 25 x25 x4 mm of 600 mm height from ground level 30 cm including fixing in PCC 1:2:4 with 20 cm X 20 cm X 20 cm (below ground level) grade aggregate foundation to be carried out at different location technical area/domestic area . Dimention of board shall be 30 cm X 25 cm. or any other dimension not more than 0.075 sq mtr of MS Board The instruction shall be written black painted board in white letters not less than 2 " size for all type of boards complete all as specified and dierected by the Engineer -in-charge including taking down unsv one. Note : (a) All necessary MS sheet, aluminium screws and PCC works etc are deemed to the rate quoted by the contractor (b) The matter to be write on board should be collected from Engineer-in-charge..
SENCO
Neha Enterprise
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .