Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.4 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹38.4 L+₹11,575 (0.30%)Rejected-Finance 5 6 MINTO ROAD ALLAHABAD 211001 | PRAYAGRAJ | UTTAR PRADESH | 211001 | L2 | Rejected-Finance Not Reasonable | |
| 3 | L3₹38.5 L+₹27,275 (0.71%)Rejected-Finance 46 HUSENI LAKDA BAZAAR 242 BELLASIS ROAD MUMBAI 400008 | MUMBAI | MAHARASHTRA | 400008 | L3 | Rejected-Finance Not Reasonable | |
| 4 | L4₹39.1 L+₹81,385 (2.13%)Rejected-Finance | L4 | Rejected-Finance Not Reasonable | |
| 5 | L5₹40.3 L+₹2.0 L (5.31%)Rejected-Finance ROOM NO D 297 PART III GANESH MURTI NAGAR CUFF PARADE ROAD COLABA MUMBAI 400005 | MUMBAI | MAHARASHTRA | 400005 | L5 | Rejected-Finance Not Reasonable |
Tender Value
₹45.6 L
EMD Value
₹91,200
Closing Date
28 Jul 2022, 6:00 pmClosed
Saurabh Gupta, EE
GE (W) Colaba, Mumbai
REPAIRS TO GALVALUME SHEET ROOF WATERPROOFING TREATMENT, CERTAIN B/R WORKS AT CERTAIN MD AND OTM ACCN OF AREA III (NML AREA) AND DRAIN , STROME DRAIN OF AGE B/R CENTRAL AT COLABA, MUMBAI
2022_MES_532566_1
8643/E8
Open Tender
Civil Works
Item Rate
180 days
GE (W) Colaba
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE (W) Colaba, Mumbai
₹91,200
Yes
3 Aug 2022
21 Jun 2022
30 Jul 2022
21 Jun 2022
28 Jul 2022
29 Jun 2022
Amount
Taking down cement plaster on brick/stone or concrete surface including racking out joints, hacking for key, scrubbing down with water to receive plaster, including removing debris/rubbish materials off the site out side MD land all as specified and directed. Note : Height of Bldg Up to fourth floor.
Taking down cement plaster on brick/stone or concrete surface including racking out joints, hacking for key, scrubbing down with water to receive plaster, including removing debris/rubbish materials off the site out side MD land all as specified and directed. Note : Height of Bldg above five Up to Eight floor.
Material and labour for 15-25 mm thick ready mix plaster in multy layer with liquid water proofing compound on fair faces of brick wall or concrete surfaces, finished even and fair, including use of scaffolding, for height of bldgs upto Four stories, all as specified and directed.by Engr-in-Charge. Name of Manufacturer: M/s Premier Floor to Roof Materials pvt. ltd/ M/s Walplast Products pvt. ltd/ M/s Ultratech Cement Ltd/M/s Sound buildcare pvt. Ltd/ or other approved equivalent make.
Material and labour for 15-25 mm thick ready mix plaster in multy layer with liquid water proofing compound on fair faces of brick wall or concrete surfaces, finished even and fair, including use of scaffolding, for Height of Bldg above five Up to Eight floor all as specified and directed.by Engr-in-Charge. Name of Manufacturer: M/s Premier Floor to Roof Materials pvt. ltd/ M/s Walplast Products pvt. ltd/ M/s Ultratech Cement Ltd/M/s Sound buildcare pvt. Ltd/ or other approved equivalent make.
Material and labour for 12 mm thick Ready Mix Plaster in single layer of make / brand - ACC's Accoplast / CK Birla's Aerocon / Speed Dry Mix's Ecoplaster / Magic Plast / Build well, on other than fair faces of concrete surfaces in wall ( internal surface ) and finished even and smooth without using extra cement, all as specified and directed. by Engr-in-Charge. Name of Manufacturer: M/s Premier Floor to Roof Materials pvt. ltd/ M/s Walplast Products pvt. ltd/ M/s Ultratech Cement Ltd/M/s Sound buildcare pvt. Ltd/ or other approved equivalent make.
Firstly old loose spelled concrete should be chiseled from roof ceiling with the help of scrapers chisel & hammer after that cleaning of rust from mild steel rod and applying cement spray 3.00 Kg per sqm by paint brush over cleaned surfaces and applying 20-50 mm thick ready mix plaster in Multi layer for ceiling on fair faces of brick wall or concrete surfaces, finished surfaces even and fair Including three coats of white wash all as specified and directed by Engr-in-charge
Material and Labour for preparation of newly plastered surface of wall and applying two coats of oil emulsion distemper over a coat of alkali resistant primer through authorised applicators of paint manufacturers only of approved shade all as specified and directed. Make: "Tractor Uno" of Asian Paints / "Jadoo"of Berger Paints / Nerolac Beauty of Nerolac paints as approved by GE all as specifeid .
Demolition of brick work or stone/ boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars etc but excluding ashlar facing dressed stone work and precast concrete articles including removing debris out side MD land complete all as specified and directed.
Material and Labour for Brick work with sub class 'B' bricks straight or curved on plan exc 6 mtr mean radius built in CM 1:6 all as specified and directed.
Material and Labour for preparing newly plastered surfaces of walls / ceilings by scrapping / rubbing and applying two coats of weather proof acrylic exterior paint (100% Acrylic) Base coat of Apex ultima protek duralife and top coat of Apex Ultima protek, Make : Asian Paints) over a coat of alkali resistent primer through authorized applicator only including use of scaffoldings from Ground floor upto 04 storeys height of bldgs bldgs all as specified and directed. Make: "Apex Ulitima" of Asian Paints "trucare" Primer/ "Weather coat all Guard"of Berger Paints / Dulux weather shield Max of Dulux Paints/Excel top Guard of Nerolac paints as approved by GE all as specifeid .
Material and Labour for preparing newly plastered surfaces of walls / ceilings by scrapping / rubbing and applying two coats of weather proof acrylic exterior paint (100% Acrylic) Base coat of Apex ultima protek duralife and top coat of Apex Ultima protek, Make : Asian Paints) over a coat of alkali resistent primer through authorized applicator only including use of scaffoldings from 5th floor upto 08th storeys height of bldgs bldgs all as specified and directed. Make: "Apex Ulitima" of Asian Paints "trucare" Primer / "Weather coat all Guard" of Berger Paints / Dulux weather shield Max of Dulux Paints/Excel top Guard of Nerolac paints as approved by GE all as specifeid .
M&L for preparation of old plastered or unplastered surface of wall including cornices etc. by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salt and trading oil and greasy spots and removal of vegetation and applying two coats of acrylic Elastomeric water proofing coating Make : Dr fixit rain coat WPC/ equvqlient to Asian Paints) through authorized applicator only including use of scaffoldings up to fourth floor all as specified and directed. Make and colour as approved by GE all as specified and directed.
All as per item No. 12 above but 5th to 8th floor all as specified and directed.
Dismantling asbestos cement sheets corrugated, semi corrugated in roof coverings including ridges all as specified and directed.
Dismantling timber in scantlings 40 Sqcm and over in section, in unframed work in any position all as specified and directed.
S&F rolled mild steel sections conforming to Gde Fe-290(Gde-165-E) as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails & guides for sliding doors, fixed with angle cleats or other connecting plates all as specified and directed.
M&L multi-rib TM profile high tensile 550 MPA yield strength colour coated galvalume corrugated steel sheet having maximum pitch of 250mm, c/c and minimum 30mm crest depth in length as per site requirement. The feed material is to be manufactured out of 0.50mm (TCT). Total coated thickness with 18-20 microns top coat over 5 microns primer and 8-10mm alkyd backer, zinc aluminium alloy of AZ-150. The sheet shall have a hot dip metallic zinc aluminium alloy coating of zinc 43.5%, aluminium (55%)and silicon (1.5%) with total mass coating of 150 gms/sqm on both sides. Covered width will be 1020mm and sheet length as per site requirement. The profile is having return leg for proper side lap. The sheet shall be fixed using self drilling/self tapping screws with EDPM seal or fixed with 'L' or 'J' type or cranked hook bolts in roof all as specified and directed by Engr-in-charge.
M&L for preparation of new untreated steel surfaces of any description exc 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer all as specified and as directed.
M&L multi-rib TM profile high tensile 550 MPA yield strength colour coated galvalume plain steel sheet having maximum pitch of 250mm, c/c and minimum 30mm crest depth in length as per site requirement. The feed material is to be manufactured out of 0.50mm (TCT). Total coated thickness with 18-20 microns top coat over 5 microns primer and 8-10mm alkyd backer, zinc aluminium alloy of AZ-150. The sheet shall have a hot dip metallic zinc aluminium alloy coating of zinc 43.5%, aluminium (55%) and silicon (1.5%) with total mass coating of 150 gms/sqm on both sides. Covered width will be 1020mm and sheet length as per site requirement. The profile is having return leg for proper side lap. The sheet shall be fixed using self drilling/self tapping screws with EDPM seal or fixed with 'L' or 'J' type or cranked hook bolts in roof all as specified and directed by Engr-in-charge.
Taking up or down steel tubing and connection including cleaning for refixing or removal to store for 15 mm bore all as specified and directed
S&F tubes medium grade galvanized with all fittings and fixed to walls and ceilings or laid in floor for 15 mm bore all as specified and directed
Demolition and breaking up drain pipes (SGSW, AC or RCC, CI) of internal dia 75/110 mm, set in cement mortar all as specified and directed.
S&F PVC (SWR) pipes, single socketed, in any length with rubber ring joints, fixed to walls, 110mm bore all as specified and directed.
S&F PVC (SWR) pipes, single socketed, in any length with rubber ring joints, fixed to walls, 75 mm bore all as specified and directed.
S&F PVC (SWR) bends any radius, 110 mm bore all as specified and directed.
S&F PVC (SWR) bends any radius, 75 mm bore all as specified and directed.
S&F PVC (SWR) branch piece, single ( single Y) equal or unequal radius, 110 mm bore all as specified and directed.
S&F for PVC (SWR) branch piece, single ( single Y) equal or unequal radius, 75 mm bore all as specified and directed.
S&F PVC (SWR) branch piece, single ( single T) equal or unequal radius, 110 mm bore all as specified and directed.
S&F PVC (SWR) branch piece, single ( single T) equal or unequal radius, 75 mm bore all as specified and directed.
S&F PVC (SWR) reducers, 110 mm bore all as specified and directed.
M&L for minor cleaning work, removal of loose concrete and filling cracks with polymer modified mortar using SmartCare RP or Epoxy Mortar and supplying and applying High performance hybrid polyurea elastomeric waterproofing coating cold applied of spray / brush applied, SmartCare Ultron liquid membrane with an elongation of 600% and tensile strength of 12.6 N/mm2 as per ASTM D 2370, crack bridging ability of 3mm as per ASTM C1305, shore A Hardness of min. 75 as per ASTM D 2240. The system includes final base preparation, epoxy primer application and applying SmartCare Ultron or approved equivalent in two coats at 1.5 kg per Sqm etc, complete as per Manufacturer specifications. Supplying and applying High performance hybrid polyurea elastomeric waterproofing coating cold applied of spray / brush applied, SmartCare Ultron liquid membrane with an elongation of 600% and tensile strength of 12.6 N/mm2 as per ASTM D 2370, crack bridging ability of 3mm as per ASTM C1305, shore A Hardness of min. 75 as per ASTM D 2240. The system includes final base preparation, epoxy primer application and applying SmartCare Ultron or approved equivalent in two coats at 1.5 kg per Sqm etc. as per Manufacturer specifications over and including padding of ready mixed micro cement concrete Type B1, 1:2:4 , 35 mm average thick concrete on RCC roof surfaces and all other similar works all as specified and directed Make:SmartCare Ultron Hybrid Polyurea/ Dr fixit flexi PU
S&F PVC (SWR) reducers, 75 mm bore all as specified and directed.
S&F PVC (SWR) vent cowl, 110 mm bore all as specified and directed.
S&F PVC (SWR) "P" trap, 110 mm bore all as specified and directed.
S&F PVC (SWR) "P" trap, 75 mm bore all as specified and directed.
S&F PVC (SWR) "Q" trap, 110 mm bore
S&F PVC (SWR) "Q" trap, 75 mm bore
M&L for cleaning of drains/culverts including removing & re-covering of RCC/CI/Steel covers by completely removing silt, soil, mud sludge, vegetation growth etc. and removing the same to out side MoD land all as directed by Engr-in-Charge for any width of drains and depth of drains exc 0.45m but n exc 0.90m all as specified and directed.
Demolition of RCC of any description and in any position not otherwise specifically provided for incluing reinforcement cut as required to facilitate demolition and separating scrap and cleaning of reinforcement and including removing debris/rubbish materials off the site out side MoD land all as specified and directed.
Demolition of cement concrete of any description and in any position not otherwise specially provided for such as bottom and sides of drain etc including removing debris/rubbish materials off the site out side MoD land all as specified and directed.
M&L for PCC 1:2:4 type B-0 (using 12.5 mm graded crushed stone aggregate) as in coping, bed concrete and all other similar work incluidng necessary formwork all as specified and directed by Engineer- in-charge.
As per item N0 9 here in before but except bricks all as specified and directed.
M&L PCC 1:3:6 type C2 (using 40mm graded crushed stone aggregate) as in surface channel and drains and like all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided including removing debris/rubbish materials off the site out side MoD land all as specified and directed.
S&F mild steel work such as grills, gratings etc with the ends of bars shoulder and/ or riveted or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters; walk ways; railings; framework of water tanks and similar work, rail & similar fixing with bolts where required conforming to grade E165 as per IS 15911: 2010 all as specified and as directed.
M&L for preparation of new untreated steel surface of any description exc 10cm width or girth and applying two coats of black Japan paint over a coat of red oxide primer all as specified and as directed.
Demolition of cement concrete(unreinforced) in ground floor & pavings n.exc 15 cm thickness (below or above GL) including removing debris/rubbish materials off the site out side MoD land all as specified and directed.
M&L hardcore of guage exc 63mm but n exc. 100 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rolled/rammed to a true surface all as specified and directed.
M&L 75mm thick plain cement concrete 1:3:6 type C-2 (using 40mm graded aggregate ) as in plinth protection including necessary expansion joint filling with bitumen at a certain distance all as specified and directed.
M&L PCC 1:4:8 type D2 as in sub base to floor 75 mm thick (using 40mm graded crushed stone aggregate) finished surfaces even and fair all as specified and directed.
M&L 30mm thick sand filling below paver block including watering & cosolidation all as specified & directed.
M&L machine pressed glossy coloured precast concrete interlocking paver block in any shape and sizes, coloured, with grey cement & pigment, M-40 grade concrete 80 mm thick, conforming to IS 15658-2006 all as specified and directed.
M&L machine pressed glossy coloured precast concrete interlocking paver block in any shape and sizes, coloured, with grey cement & pigment, M-35 grade concrete 60 mm thick, conforming to IS 15658-2006 all as specified and directed.
M&L PCC (1:2:4) type B1 using 20 mm graded crushed stone aggregate as in kerb stone all as specified and directed.
M&L two coats of synthetic enamel paint over a coat of plaster priming surfaces including preparation new steel surfaces all as specified and directed .
M&L for preparing old painted brick or concrete surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of floor coat emulsion paint PLATINUM SERIES all as specified and directed. Make : INDIGO / Equivalent
S&F factory made precast RCC drain cover of size 900 mm x 600 mm x 100 mm thick and fixed to drain in CM (1:4) all as specified and directed.
S&F for polymeric HDPE LED Kerb stone of size 50 cm x 20 cm x 15 cm jointed in cement mortar (1:6 ) and struck flush including load carrying capacity 800 kg LED strip length 465 mm operational voltage reqd 36 volts with 2 nos connectors (1 male 1 female) and 5 N0 foundation rods dismentling of old PCC kerb stone coloured of kerb stone approved by GE all as specified and directed. Make Hydrose or equvalient , approved sample as kept in GE Office.
S&F SMPS LED Kerb stone driver output 9.7 a, 36 v with 16 A double pole MCB and junction box (brand Sintex) all as specified and directed.
Frends Enterprises
Unitech Enterprises
SRI SAIRAM COUNSTRUCTION
GANGAJAL
vikas construction
PRABHU ASSOCIATES
Bidder Name
Unitech Enterprises
Frends Enterprises
SRI SAIRAM COUNSTRUCTION
PRABHU ASSOCIATES
vikas construction
GANGAJAL
SAI SIDDHI CONSTRUCTION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .