Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.9 LAccepted-AOC | ₹36.9 L | L1 | Accepted-AOC L1 bidder |
| 2 | L2₹38.8 L+₹1.8 L (4.90%)Rejected-Finance 25 13 1 AMBEGAON PATHAR PUNE 411046 | PUNE | MAHARASHTRA | 411046 | ₹38.8 L+₹1.8 L (4.90%) | L2 | Rejected-Finance Other than L1 bidder |
| 3 | L3₹40.5 L+₹3.6 L (9.73%)Rejected-Finance | ₹40.5 L+₹3.6 L (9.73%) | L3 | Rejected-Finance Other than L1 bidder |
| 4 | L4₹40.9 L+₹3.9 L (10.6%)Rejected-Finance NIL | ₹40.9 L+₹3.9 L (10.6%) | L4 | Rejected-Finance Other than L1 bidder |
| 5 | L5₹41.0 L+₹4.0 L (10.9%)Rejected-Finance | ₹41.0 L+₹4.0 L (10.9%) | L5 | Rejected-Finance Other than L1 bidder |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
15 Jun 2020, 6:00 pmClosed
CWE (AF) Bagdogra
Commander Works Engineers (AF) Bagdogra Bagdogra Airport (WB) Pin- 734 421 Tele 0353 - 2698308
SPECIAL REPAIR/ REPLACEMENT TO DUCT TYPE CENTRAL AC PLANT AT AF STN BAGDOGRA UNDER GE (AF) Bagdogra
2020_MES_343814_1
8414/BAG/2020-21/E8
Open Tender
Machineries/ Mechanical Engg Items
Item Rate
180 days
Bagdogra
MES Contractor enlisted as Class D category c(i) having deposited Standing Security of Rs 1,00,000.00 with dept. Contractors not enlisted in MES should meet the MES enlistment criteria corresponding to appropriate class and category.
10 documents required · 10 mandatory
₹500
GE (AF) Bagdogra
₹80,000
Yes
28 Aug 2020
11 May 2020
22 Jun 2020
11 May 2020
15 Jun 2020
1 Jun 2020
11 May 2020 - 8 Jun 2020
Amount
Note 1: (Applicable for all parts/items) : The bidders/ contractors are advised to read tender document, all drawings & all corrigendum/amendments and general condition of contracts before entry/quoting the rates. Note 2:- Attention to bidder is hereby invited to upload revised BOQ if published during their bid submission. Uploading of incorrect/ pre-revised BOQ shall be treated as non bonafide and rejected. Fixed credit has been given in technical documents which shall be taken into account during acceptance of bid/tender.
Supply, install, testing & commisioning of 415v ± 10 % volt, 3Ph- 50 Hz Top Discharge type & modular type Variable referigerant flow system suitable for operation with R 410a referigerant and having capacity 56HP-(03 Working+01 standby) Nos complete all as specified and as directed. Outdoor unit:- All inverter multiple scroll compressors,in each module unit able to operate in case of break down one compressors with heating and cooling mode, air cooled condenser with protective coated fins, low noise propeller type fan with motor, auto address setting, auto check function for connection error, electronic expansion valve,refrigerant cooled PCB,outdoor mounting frame,micro processor panel and other standard accessories as per specification.The unit shall be operational in very very silent mode(approx 40 db) in night time operation. The indoor unit variable refrigerant flow 220-240 v/1Ph/50 Hz Indoor Unit :-Ductable units type such as 6.0 TR-01 No, 5.0 TR-02 Nos, Cassettes units type such as 1.0 TR-01 No, 1.7 TR- 02 Nos, 2.8 TR- 02 Nos and Hi-wall unit such as 1.3 TR- 02 Nos, 1.5 TR- 03 Nos, 2.5 TR- 01 No, 2.8 TR- 01 No comprising of coil, filter, fan complete with all standard accessories. Control device :- Corded controller - 03 Nos, Cordless Controller -12 Nos, canvas connection-03 Nos , Y joints/ Distribution Joints for out door & indoor unit networking - 17 Nos Central controller for all IDUs on central point and refrigeration network joint as required complete all as specified and as directed. Note:- All carpentary and masonery works for installation of AC plant & making good of disturbed surface as per existing are deemed to be included in this rate.
Supply, installation and commisioning of the following size CU referigerant pipes duly insulated with 19mm/13mm close cell elastomeric nitrile rubber insulation between each set of outdoor and indoor units complete all as specified and as directed.
Supply, installation and commisioning of PVC pipe medium class (for drainge of water from IDU) of the following size with 6mm nitrile rubber insulation complete all as specified and as directed.
Supply, installation, testing and commissioning of GSS ducting of size 24 Gauge including necessary support, adjustable dampers complete all as specified and as directed.
Supply, installation, testing and commissioning of GSS ducting of size 22 Gauge including necessary support, adjustable dampers complete all as specified and as directed.
Supply and fix 9 mm thick XLPE insulation for duct insulation complete all as specified and as directed.
Supply and fix open cell nitrile rubber acoustic insulation complete all as specified and as directed.
Supply, fixing, testing and commissioning of supply air diffusers/ grill of powder coated aluminium with aluminium volume control dampers complete all as specified and as directed.
Supply, fixing, testing and commissioning of return air diffusers/ grill of powder coated aluminium without aluminium volume control dampers complete all as specified and as directed.
Supply and fix 2 Core x 0.75 sheilded cable with conduit for communication cabling between ODU and IDU as per OEM specification with all fitting on roof/ wall / ceiling making good the same with cement plaster in cement morter(1:6) and painting complete to match with the existing surfaces complete all as specified and directed.
Supply and fix sequential timer for server room complete all as specified and as directed.
Taking down old existing AC plant including its fittings & fixtures from site and deposite to MES Store yard complete all as specified and as directed.
M & L for sub main wiring with PVC insulated unsheathed copper conductor FRLS cable of size 1.5 Sqmm two run drawn through and including PVC casing caping on wall including 1.5 sqmm insulated unsheathed copper conductor cable for continuous earthing from main earth dolly complete all as specified & directed. Note :- Two run of 1.5 Sqmm copper cable + one run of 1.5 Sqmm copper cable earthed wire + one run of PVC casing caping of suitable size will be measured as one unit.
M & L for sub main wiring with PVC insulated unsheathed copper conductor FRLS cable of size 2.5 Sqmm two run drawn through and including PVC casing caping of suitable size on wall including 2.5 sqmm insulated unsheathed copper conductor cable for continuous earthing from main earth dolly complete all as specified & directed. Note :- Two run of 2.5 Sqmm copper cable + one run of 2.5 Sqmm copper cable earthed wire + PVC casing caping of suitable size will be measured as a single unit.
S & F of MCCB distribution boards TPN, 4 way, 415 volts 50 Hz, AC double door vertical loadline DBs are fitted with isolated copper bus bar, IP-54 protection, cement Spill Protector, mechanical impact strenfgth IK 09, surrounded neutral link, earth link, earthing suitably for MCCB's upto 250 Amp as I/C (Frame 2) and SP/TP MCB's as outgoing complete all as specified and directed.
S & F adjustable thermal setting class II front face suitable for isolation adjustable overload setting Ir=(0.8 to 1.0) X In, adjustable short circuit setting Isd=(5-10) X In, MCCB 160 Amp, 4 Pole, breaking capacity 36 KA, 415 Volt, 50 Hz complete all and specified and directed.
S & F MCB ,TPN of 415 volts ,AC ,50 Hz of capacity 32 Amps 10 KA rupturing capacity complete all as specified and as directed.
M & L in replacement Earthing complete with galvanized steel earth plate electrode 60 cm X 60 cm X 6.3 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below ground level connecting to the GI strip 32 x 6mm, by means nut bolt, nuts, check nuts and washer of the GI Earth wire protected by provision of GI light grade pipe 40 mm incl provision of concrete pit in PCC (1:2:4) type B-1 using 20 mm graded stone aggregated with 40 mm thick cover with RCC (1:2:4) reinforced with XPM (weight not less than 4 Kg / Sqm) and frame of angle iron 25mm X 25 mm X 3mm with lugs 2 Nos and with 6 mm dia MS bar handle made to shape, GI light grade 20 mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling, taste point made out of phosphorus bronze with fixing arrangement, funnel, wire mesh and earth work , returning filling in and removal of surplus soil to a distance not exceeding than 50 mtr, all as per electric plate No 3 of SSR Part I 2009 and connection to earth test point all as specified incl testing on completion”.
M & L Galvanised iron stip 32 x 6 mm burried in ground all as specified and directed by Engr-in-charge
M & L for sub main wiring with PVC insulated unsheathed copper conductor FRLS cable of size 10 Sqmm two run drawn through and including suitable size of PVC casing caping on wall including 10 sqmm insulated unsheathed copper conductor cable for continuous earthing form main earth dolly complete all as specified & directed. Note :- Two run of 10 Sqmm copper cable + one run of 10 Sqmm copper earthed cable + one run of PVC casing caping of suitable size will be measured as a one unit.
M & L for sub main wiring with PVC insulated unsheathed copper conductor FRLS cable of size 6 Sqmm two run drawn through and including suitable size of PVC casing caping on wall including 6 sqmm insulated unsheathed copper conductor cable for continuous earthing form main earth dolly complete all as specified & directed. Note :- Two run of 6 Sqmm copper cable + one run of 6 Sqmm copper earthed cable + one run of PVC casing caping of suitable size will be measured as a one unit.
M & L for sub main wiring with PVC insulated unsheathed copper conductor FRLS cable of size 4 Sqmm two run drawn through and including suitable size of PVC casing caping on wall including 4 sqmm insulated unsheathed copper conductor cable for continuous earthing form main earth dolly complete all as specified & directed. Note :- Two run of 4 Sqmm copper cable + one run of 4 Sqmm copper earthed cable + one run of PVC casing caping of suitable size will be measured as a one unit.
Supply and fix distribution board sheet metal enlosure double door shutter type factory made fixed flush with wall or outside on wall surface suitable for mounting isolators & MCB's 240 volts SPN 8 ways, 200 Amp rated bus bar with front openable cover complete all as specified & directed.
Supply and fix distribution board sheet metal enlosure double door shutter type factory made fixed flush with wall or outside on wall surface suitable for mounting isolators & MCB's 240 volts, SPN 4 ways, 200 Amp rated bus bar with front openable cover complete all as specified & directed.
Supply and Fixing in replacement of MCB SP 6-32 Amps, 230 Volts, 50 Hz with 10 KA ,'C' series complete all as specified & directed.
S & F RCBOs 63 Amps, 240 volts, AC 50 Hz, IP 20 Protection for earth leakage, overload & short circuit protection double pole, 30 mA,10 KA rupturing capacity complete all as specified and as directed.
S & F sheet metal enclosure single pole and neutral enclosure with a two pin and earth plug & socket complete with one single pole MCB 20 Amp complete all as specified and as directed.
Supply and installation air cooled split unit air conditioner electric driven single phase of capacity 1.5 TR ,3 star rated of ISEER or 5 star as per BEE complete all as specified and as directed.
M & L for sub main wiring with PVC insulated unsheathed copper conductor FRLS cable of size 16 Sqmm four run drawn through and including PVC conduit of suitable size on wall including 10 sqmm two run insulated unsheathed copper conductor cable for continuous earthing from main earth dolly complete all as specified & directed. Note :- Four run of 16 Sqmm copper cable + Two run of 10 Sqmm copper cable + One run of PVC conduit of suitable size will be measured as one unit.
M&L for PCC 1:3:6, type C2 (using 40 mm graded stone aggregates) for foundation of pole, stay incl frame work complete all as specified and as directed.
SAI CONSTRUCTION
BEEPEE AND COMPANY
SHRI PRADEEP PARIK
M/S SARKAR ELECTRIC
M/S East India Traders
M/S BIJAY KUMAR SHIVA
M/S POWER ENGINEERS
M/S S K BOSE AND CO
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .