GE (AF) GORAKHPUR
GE (AF) GORAKHPUR Pin-273008
PROVISION OF EXTERNAL SERVICES TO NFS BUILDING REPLACEMENT OF VOLTAGE STABILIZER AND CERTAIN MINOR WORKS AT AF STATION GORAKHPUR
2020_MES_395951_1
8743/E8
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
GE (AF) GORAKHPUR
as per tender documents
7 documents required · 7 mandatory
₹500
Yes
GE (AF) GORAKHPUR
₹56,000
Yes
14 Jan 2021
18 Nov 2020
18 Dec 2020
18 Nov 2020
17 Dec 2020
5 Dec 2020
60 days
Amount
Surface excavation n.exc. 30 centimeter deep and averaging 15 centimeter deep and getting out in soft/ loose soil complete all as specified and directed.
Removing surplus excavated material not exc 50 mtrs and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed.
M&L for PCC type C-2 1:3:6 using 40 mm graded aggregate as in foundation filling, bed blocks and mass concrete complete all as specified and directed.
M&L for hard core of broken stone or boulders of gauge n.exc 63 mm deposited spread and leveled in layers n.exc 15 cm thick watered and rammed to a true surface complete all as specified and as directed.
M&L for 150mm thick PCC 1:2:4 type B-2 using 40mm graded mechanically crushed stone aggregate as in floor laid in alternate panels finished with rolling and spiked rolled to surfaces making impression of expanded metal complete all as specified and directed.
M&L for forming Contraction joint 30mm deepx10mm wide, filled with sealing compound grade ‘B’ complete all as specified and directed.
M&L for forming Contraction (Dummy) joints 65mm deepx10mm wide, filled with sealing compound grade ‘B’ complete all as specified and directed.
Excavation in trenches in soft/loose soil n.exc 1.5 mtr wide and n.exc 1.5 mtr depth and getting out complete all as specified and directed.
Returning, filling in including spreading, leveling, watering and well ramming in layers not exc 25 cm thick complete all as specified and directed.
Cutting of cast iron pipes of 150mm bore in position for insertion of new tees, branches, etc. including diverting due to residual water in pipes complete all as specified and directed.
Cutting of cast iron pipes of 80mm bore in position for insertion of new tees, branches, etc. including diverting due to residual water in pipes complete all as specified and directed.
S&F 25mm dia steel water tubing galvanized medium grade with all fittings of medium grade laid in trenches complete all as specified and directed.
S&F 40mm dia steel water tubing galvanized medium grade with all fittings of medium grade laid in trenches complete all as specified and directed.
S&F 25mm dia gun metal, globe or gate valves, with iron wheel hand, screwed both ends for iron pipes complete all as specified directed.
S&F 40mm dia gun metal, globe or gate valves, with iron wheel hand, screwed both ends for iron pipes complete all as specified directed.
M&L for Provision of brick masonry valve pit/chamber of 600x600x600mm size (internal dimensions) including necessary excavation & earthwork and frame with cover complete all as specified and shown in drg No CEAFALD/TD and directed.
Supply and providing sand cushioning with dry clean sand 15 cm below cable and 8 cm above the cable complete all as specified and directed. Note: Punned thickness shall be measured for the purpose of payments.
Supply and laying burnt bricks old size sub class-B laid in trenches for cable protection with length of brick perpendicular to length of cable complete all as specified and directed.
S&F 80mm bore GI pipe, light grade with all fittings laid in trenches, road crossing and fixed to walls, on poles etc for cable protection complete all as specified and directed.
S&F 150mm bore GI pipe, light grade with all fittings laid in trenches, road crossing and fixed to walls, on poles etc for cable protection complete all as specified and directed.
Supply, laying and testing 120 Sqmm, 3.5 Core XLPE insulated, armoured heavy duty electric cable, screened PVC bedded, galvanised steel strip or wire, with aluminium conductor 1100 V grade, laid in trenches/ along poles, ducts or through sleeve complete all as specified and directed Note: Earth work, sand cushioning and bricks will be measured and paid separately under relevant items.
All as per item No. 21 above but for 150Sqmm, 3.5 core XLPE cable.
S&F MCCB, 4 pole, 250 Amp, 415 volts, 35 KA breaking capacity complete all as specified and directed .
Supplying, installation, testing and commissioning of Voltage stabilizer (confirming to BIS 9815: Part1: 1994) for automatic operation, three phase, copper wound, oil immersed, indoor type, digital micro controlled servo stabilizer including first filling of fresh oil and standard fittings & phase unbalanced type and designed for input variation between 300 V to 480 V with output voltage stabilized at 415 with accuracy ± 2.5% and speed of correction 8 Volts per second with overload/short circuit protection, High low voltage cut off and of capacity 50 KVA complete all as specified and directed.
All as per item No. 24 above but for 150 KVA.
All as per item No. 24 above but for 300 KVA.
Supply and install and testing window type air conditioner of capacity 1.5 Ton, 3 star rating inverter type for working on 230 volt, SP, 50 Hz supply complete including cutting of existing wall and proper fixing making good disturbed surface with existing surface complete all as specified and directed. Make : Carrier/Voltas/Bluestar/Hitachi/LG
S&F sheet metal enclosures with socket plug top and MCBs with a two pin and earth plug and socket complete with one single pole MCB 20 Amp complete all as specified.
S&F MCB, SP, 10 to 32 Amps, 'C' curve, 10 KA breaking capacity, 240 volts complete all as specified and directed.
M&L for sub main wiring with 2 Nos single core PVC insulated unsheathed 6.0 sqmm stranded copper conductor cable and 1 No single core PVC insulated-unsheathed 4.0 sqmm stranded copper conductor cable for earth continuity, drawn in & including suitable PVC casing & capping /PVC pipe with all fittings ISI mark complete all as specified and directed. (length of 2 No 6.0 sqmm conductor cable, 1 No 4.0 sqmm conductor earth continuity cable and accessories shall be measured as one unit length)
S&F automatic voltage stabilizer for low and high voltage correction equipped with electronic transistorized relay suitable for operation single phase, AC, 50 HZ complete with Voltmeter, indicators and designed for input voltage 130 to 300 stabilized between 215 V to 220 V of capacity 4 KVA (not less than 17 amp) complete all as specified and directed. Make : BLUE BIRD/Microtek /V Guard/ Logicstate
Supply and install and testing split type air conditioner of capacity 1.5 Ton, 3 star rating inverter type for working on 230 volt, SP, 50 Hz supply complete including cutting of existing wall and proper fixing making good disturbed surface with existing surface and providing water pipe upto ground level complete all as specified and directed. Make : Carrier/Voltas/Bluestar/Hitachi/LG
M&L for earthing complete as in replacement with galvanized steel earth plate 60cmx60cmx6 mm thick buried vertically in ground to depth not less than 2.25 metres below ground level, with top edge of earth plate not less than 1.5 m below ground level, connected to earth lead GI 4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron and connection to main switch board of panel, including watering pipe GI 20 mm bore light grade, including protection pipe GI medium grade 15mm bore for earthing lead, wire mesh, funnel, salt, charcoal dust, excavation and refilling pit with PCC 1:2:4 type B1, precast RCC cover using XPM reinforcement weighing not less 4kg/sqm in lieu of CI cover and frame all as shown in electric plate of SSR part-I (2009), including testing on completion all as directed.
S&F sheet metal enclosure (MCCB DBs) three phase and neutral with 200 Amps rated bus bar 6 way double door type suitable for on MCCB as incomer and 18 Nos SPN MCB for outgoing complete all as specified and directed.
S&F MCCB, 4 pole, 125 Amp, 415 volts, 16 KA breaking capacity complete all as specified and directed .
S&F MCB, SPN, 32 Amps, 'C' curve, 10 KA breaking capacity, 240 volts complete all as specified and directed.
M&L for mild steel iron grill duly painted with synthetic enamel paint for safe guard of window type AC 1.5 Ton capacity complete all as specified and directed.
Hindustan Power Corporation
sri krishna construction
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .