Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.2 LAccepted-AOC COLLEGE ROAD CHABUA PO CHABUA DIST DIBRUGARH ASSAM 786184 | DIBRUGARH | ASSAM | 786184 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹5.0 L+₹63,254.25 (14.5%)Rejected-Finance 16 BAITHAKKHANA ROAD 16 BAITHAKKHANA ROAD SEALDAH BAITHAKKHANA ROAD SEALDAH BAITHAKKHANA ROAD SEALDAH KOLKATA | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹5.3 L+₹88,816 (20.3%)Rejected-Finance 1389 RADHETENAMENT SOCIETY SARDAR ROAD SURENDRANAGAR SURENDRA NAGAR GUJARAT 363001 | SURENDRANAGAR | GUJARAT | 363001 | L3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | L4₹5.3 L+₹93,457.75 (21.4%)Rejected-Finance AT ROAD NEAR RENUKA CINEMA P O DIST TINSUKIA ASSAM PIN 786125 | TINSUKIA | TINSUKIA | ASSAM | 786125 | L4 | Rejected-Finance OTHER THAN LOWEST | |
| 5 | L5₹5.5 L+₹1.1 L (24.8%)Rejected-Finance | L5 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹5 L
EMD Value
₹10,000
Closing Date
6 Jan 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Commander Works Engineer Dinjan
Headquarters Commander Works Engineer Dinjan Military Engineer Services Post - Panitola, Dist - Dibrugarh Pin Code - 786 183 (Assam)
REPAIR/MAINT OF EXTERNAL ELECTRIC SUPPLY AT ALONG MIL STN UNDER GE 872 EWS
2020_MES_400841_1
83049/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
ALONG UNDER GE 872 EWS
As per tender documents
7 documents required · 7 mandatory
₹500
GE 872 EWS
₹10,000
Yes
25 Feb 2021
4 Dec 2020
7 Jan 2021
4 Dec 2020
6 Jan 2021
24 Dec 2020
4 Dec 2020 - 23 Dec 2020
60 days
Amount
Dismantling steel poles/ struts, any size, setting aside for reuse within 50 metres
Dismantling cross-arms of mild steel channel or angle sections etc. complete and setting aside for re-use or removing to store or for schedule of credit
Dismantling earth wire or copper conductor, service feeder or distributor span removing to store or taken on schedule of credit complete all as specified and as directed.
Dismantling ACSR or AAC conductors removing to store or taken on schedule of credit complete all as specified and as directed.
Dismantling stay assembly complete (Note: Demolition of concrete, etc. and excavation measured shall be measured and paid separately separately.)
Disconnecting & Taking down/out unserviceable LT Cable of any size and any description from trenches, floors, walls, GI Pipes, etc including serviceable cables, bricks etc keep in safe custody for re-use complete all as specified and as directed. NOTE : Nesessary earth works will be measured & paid seperately under appropriate items.
Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. or for cable laying or not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in soft/ loose soil complete all as specified and as directed.
Excavating in trenches not exceeding 1.5 m wide and exceeding 1.5 m but not exceeding 3.0 in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. or for cable laying or not exceeding 10 sqm on plan and exceeding 1.5 m but not exceeding 3 m in depth and getting out in soft/ loose soil complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/ loose/ hard/ dense soil complete all as specified and as directed.
Removing excavated material (soils) not exceeding 50 m and depositing where directed at a level n exc. 1.5 m above the starting point
M & L for cement concrete in foundation, filling and mass concrete in M7.5(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate complete all as specified and as directed.
M & L for cement concrete in foundation, filling and mass concrete in M10(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate complete all as specified and as directed.
M & L for cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate in roof kerbs or mud stops, rounded or chamfered on edges complete all as specified and as directed.
M & L for steel tubular swaged pole 410 SP-31 (9.0 metre long) including CI base plate, finial taper plug, bolts, nuts & screws as per IS 2713 Part -I & II including painting with two coats of aluminium paint over a coat of red oxide zinc chrome primer on exposed portion and making strips of width 30 cm upto 1.5 m from the ground level in black and yellow shade in alternate layer including numbering of poles using two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer and two coats of anticorrosive paint over a coat of red oxide primer to embedded portion of pole including making good to match existing area complete all as specified and as directed.
M & L for cross arms, bracings, supports, clamps, back plates and stay clamp fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and applying two coats of aluminium paint over a coat of red oxide primer complete all as specified and as directed.
S & F pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100 mm height, 65 mm dia for 1100 volts grade complete all as specified and as directed.
S & F shackle type porcelain vitreous white brown or green insulator for working pressure 11000 volts of 150 mm dia and 150 mm height including galvanised steel straps of 38 mm X 5 mm size insulator bolt, washer & nuts complete all as specified and as directed.
M & L for Loop type insulator, small size, with overall dimensions 90 mm X 65 mm, cable hole dia 16 mm, creepage distance 41 mm, minimum failing load 44000 N, vitreous porcelain, white, brown or green, Designation A as per IS 5300: 1969 complete all as specified and as directed.
S & F galvanised mild steel wire 3.15 mm or 4 mm dia in overhead lines complete all as specified and as directed.
Supply, fixing and stringing ACSR (aluminium conductor galvanized steel-reinforced) of any size and type in accordance with site requirement and binding on insulator by means of 22 gauge aluminium binding wire to permissible sag complete all as specified and as directed.
Fixing and stringing only ACSR (aluminium conductor galvanized steel-reinforced) of any size and type in accordance with site requirement and binding on insulator by means of 22 gauge aluminium binding wire to permissible sag complete all as specified and as directed.
S&F PVC Fibre separator for LT Line 1100 Volt over head conductor 2/3/4- wire system for horizontal spacing of conductor complete with nut and bolts minimum 2 No. to prevent the lines touching each other on heavy winds as a preventive arrangement to the existing system, complete all as specified and as directed.
M & L for stay assembly of stay rod of diameter 16 mm complete with accessories as shown in electrical plate No. 1 complete all as specified and as directed .(Note: Loop type insulator, stay clamps, excavation and concrete shall be measured and paid separately.)
M & L painting on steel tubular swaged pole 410 SP-22 (8.5 metre long) with two coats of aluminium paint over a coat of aluminium red oxide primer on exposed portion including painting on cross arms, street light brackets and including making strips upto 1.5 m from the ground level by black/ yellow paint in alternate layer and including numbering of poles complete all as specified and as directed.
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 2 core, nominal cross sectional area of main conductor 6 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed.
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 2 core, nominal cross sectional area of main conductor 10 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed.
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 4 core, nominal cross sectional area of main conductor 16 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed.
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 3 core with reduced neutral conductors (3½ core), nominal cross sectional area of main conductor 70 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed.
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 3 core with reduced neutral conductors (3½ core), nominal cross sectional area of main conductor 120 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed.
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 3 core with reduced neutral conductors (3½ core), nominal cross sectional area of main conductor 25 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed.
S&F Straight through joint with jointing kit suitable for 1100 Volt grade UG LT PVC insulated sheathed, armoured, cable with aluminium conductor, cross-sectionsl area 16 Sqmm 4 core to 95 Sqmm 3.5 core complete with all accessories, complete all as specified and as directed.
Supply & spreading in trenches dry river sand cushioning to underground cable in trenches including spreading, levelling hand punning down complete all as specified and directed Note:- Depth of sand cushioning will be measured after punning down and levelling the sand properly.
M&L for HDPE double wall corrugated (DWC) high density polythene pipes cut to length/size as per site requirement having corrugation on the outer wall and plain surface on the inner wall confirming to IS : 14930 (Part I & II) for protection og underground cable/in PCC with and incl all fitting as required at site for outer dia 40mm, inner dia 32mm including cutting floor & making good the same to match the existing adjoining surface etc complete all as specified and as directed. Make : Rex Poly Extrusions (Eldrex) or equivalent make (ISI Marked) Note : Rates also included accessories for fixing DWC pipe along wall/roof/cable trays.
Supply & laying unreinforced precast concrete cable cover class LV type 2, flat shape, dimension 300 mm X 180 mm X 40 mm as per IS 5820: 1970 complete all as specified and directed.
M & L for MCCB 3 Pole, 415 V, fixed type, 63 Amps with breaking capacity 25 kA complete all as specified and as directed.
M & L for MCCB 4 Pole, 415 V, fixed thermal & fixed magnetic setting type, 100 Amps with breaking capacity 25 kA complete all as specified and as directed.
M & L for MCCB 4 Pole, 415 V, Adjustable type, 160 Amps with breaking capacity 25 kA complete all as specified and as directed.
M & L for MCCB 4 Pole, 415 V, adjustable thermal & adjustable magnetic setting, 200 Amps with breaking capacity 25 kA complete all as specified and as directed.
M & L for MCCB 4 Pole, 415 V, adjustable thermal & adjustable magnetic setting, 200 Amps with breaking capacity 36 kA complete all as specified and as directed.
S & F onload change over switch 100 Amps, 4 pole, 415 volts, AC, 50 Hz in sheet metal enclosure front operating type with all necessary fixing accessories such as nuts, bolts, clamps, etc. complete all as specified and as directed.
S & F onload change over switch 63 Amps, 415 volts, four pole, AC, 50 Hz in sheet enclosure with all necessary fixing accessories such as nuts, bolts, clamps, etc. as per Havells catalogue Part No. IHCFFE0063 complete all as specified and as directed.
M&L Cleaning, Scraping of exposed surfaces of LT Panel/Feeder pillar/pole bax, indoor/outdoor type and applying one coat of synthetic enamel paint (paint & shade as approved) with spray painting machine including writing MES No. and Machine No. with Black paint, letter 50mm high and 15mm wide, complete all as specified and as directed.
M & L for earthing complete with galvanised steel plate earth electrode 600 mm X 600 mm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to earthing lead of 4.0 mm dia galvanised mild steel wire by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 20 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and as directed by the Engineer-in-charge.
Taking down insulator pin/insulator shackle type/insulator loop type etc. any type and size complete all as specified and as directed.
Taking down main switch/MCB DB/ sheet metal enclosure by disconnecting the electric supply including MCB/MCCB/Cut out etc. any type and size complete all as specified and as directed.
Taking down onload change over switch any type and size complete all as specified and as directed.
M/s HALDER ENTERPRISE
M/S S. P. ENTERPRISE
STANDARD ELECTRIC WINDERS
FREEZCON
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .