Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.2 LAccepted-AOC PANDUA NAKSIMAHALLA 712149 | PANDUA | HOOGHLY | WEST BENGAL | 712149 | L1 | Accepted-AOC L1 Bidder | |
| 2 | L2₹11.0 L+₹83,791 (8.24%)Rejected-AOC | L2 | Rejected-AOC L2 Bidder | |
| 3 | L3₹14.6 L+₹4.5 L (44.1%)Rejected-AOC | L3 | Rejected-AOC L3 Bidder |
Tender Value
₹11.4 L
EMD Value
₹22,867
Closing Date
6 Dec 2024, 2:30 pmClosed
REGIONAL MANAGER
Hooghly Region Chinsurah Ram Mandir WBSEDCL
Supply Erection Fabrication and Fixing of Sub station Structure for Renovation of Vastara 33 11 KV Substation Switch Yard with allied works under Tarakeswar Division of Hooghly Region
2024_WBSED_770698_1
RM/HG/ELECT/TENDER/2024-25/29
Open Tender
ELECTRICAL WORKS ORG
Item Rate
60 days
vastara serampore
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹22,867
29.11.2024
20 Jan 2025
19 Nov 2024
10 Dec 2024
26 Nov 2024
6 Dec 2024
26 Nov 2024
29 Nov 2024
Amount
Erection of Gantry Structure for Isolator cum LA support structure with 9 mtr PCC pole along with supply of all nuts, bolts & LA with foundation Base plate 430x430x8 mm (as per drawing PLN/(D)/SS/112)
Supply, Delivery & Erection of Galvanised (as per IS Specification) Structure along with G.I Foundation Bolt, Plate, Nuts,Bolts and erection of the same Structure on existing Concrete foundation of H/L Isolator Structure (as per drawing PLN/(D)/SS/81)
Supply, Delivery & Erection of Galvanised (as per IS Specification) Structure along with G.I Foundation Bolt, Plate, Nuts,Bolts and erection of the same Structure on existing Concrete foundation of L/L Isolator Structure (as per drawing PLN/(D)/SS/82)
Supply, Delivery & Erection of Galvanised (as per IS Specification) Structure along with G.I Foundation Bolt, Plate, Nuts,Bolts and erection of the same Structure on existing Concrete foundation of 33 KV CT Structure (as per drawing PLN/(D)/SS/57)
Supply, Delivery & Erection of Galvanised (as per IS Specification) Structure along with G.I Foundation Bolt, Plate, Nuts,Bolts and erection of the same Structure on existing Concrete foundation of 33 KV PT Structure (as per drawing PLN/(D)/SS/57)
Supply, Delivery & Erection of Galvanised (as per IS Specification) Structure along with G.I Foundation Bolt, Plate, Nuts,Bolts and erection of the same Structure on existing Concrete foundation of LT Cable Support Structure.
Supply, Delivery & Erection of Galvanised (as per IS Specification) Structure along with G.I Foundation Bolt, Plate, Nuts,Bolts and erection of the same Structure on existing Concrete foundation of 33KV HG Fuse Unit (as per drawing RE/HT/36)
Erection of 33KV, 400A, CR Type Isolator H.L with E.S
Erection of 33KV, 400A Centre Rotation Isolator H.L. w/o E.S
Erection of 33KV, 400A Centre Rotation Isolator L.L. w/o E.S
Erection of 33KV, C&R Panel SCADA compatible for Feeder control with Directional relay.
Erection of 36KV VCB O/D Type SCADA compatible
Erection of 33KV 400-200/1-1 A
Erection of 33KV PT (1Ph O/D Type)
Laying of 1.1KV 4Cx185Sqmm PVC Cable
Laying & Fixing of 1.1Kv 4Cx2.5Sqmm Copper Control Cable with Supply of Cable Lugs, Glands, Tapes, Sockets etc.
Laying & Fixing of 1.1Kv 8Cx2.5Sqmm Copper Control Cable with Supply of Cable Lugs, Glands, Tapes, Sockets etc.
Laying & Fixing of 1.1Kv 12Cx2.5Sqmm Copper Control Cable with Supply of Cable Lugs, Glands, Tapes, Sockets etc.
Erection of 42KV class Gapless Lightning arrestor with supply of compression Connector (3Nos in One Set)
Making End Termination joint including Supply of Cable lugs, glands, tapes, sockets etc of 1.1KV, 4CX185sq mm PVC/XLPE cable
Erection of ACSR 200 Sq. mm (PANTHER) Conductor (3 Wire) including laying, hoisting, jointing etc.
Supply & Making of Compression Joint for ACSR "PANTHER" Conductor.
Fixing of 33 KV Pin Insulator
Fixing of 33 KV Post Insulator
Supply, Delivery & Installation of C.T Junction Box
Supply, Delivery & Installation of P.T Junction Box
Supply, Delivery & Installation of LT Distribution Box for Station Service
Dismantling & Installation of 100KVA, 33/0.4Kv Stn Service Transformer
Shifting 33KV VCB along with Structure
Shifting of 33KV 200-100/1-1-1A CT
Assorted Dismantling Works & Store Return
Supply, Delivery & Erection of 1.5 inch Inner dia, (Outer dia 2.0") Aluminium pipe as per IS Specification with extruded Aluminium Connectors [Isolator Pad to Pipe Bus (138Nos), Flexible Pad for Isolastor to Pipe (6Nos), Bus Pipe to Pipe Connector (12 Nos),Bus Pipe to Pipe Tee Connector (36 Nos) Rigid Bus Support, Bus Pipe End Caps, Isolator Pad to ACSR Panther Bi-metallic connector(36Nos) Etc.] for running 33 KV Bus including jointing (Only Bus Support Post Insulators to be supplied by WBSEDCL).
Supply of Hot Dip G.I.flat 65x6 mm and earthing of different Structures, Shielding Poles and Equipments ( 33KV & 11 KV VCBs, CTs, PTs, CR Panels, AC & DC Panels, Chargers etc) by rising the flat from Earth mat / Pit by mean of welding & bolting as per Indian Standard, approved drawing & design of WBSEDCL and direction of Supervisory Officer. Welding must be done with using good quality sticker and G.I. Spray, including proper scraping and smoothing the surface.
Supply of perforated G.I. Pipe 40 mm diameter of 3 mtr. Long ISI marked of make (TATA / Jindal) and driven the said pipes in the soil with filling pentonite powder in the pit as per Indian Standard, approved drawing & design of WBSEDCL and direction of Supervisory Officer.
Fabrication of Iron materials (Angle, Channel, Flat etc which will be Supplied by WBSEDCL) for hot dip galvanisation and cleanning till good surface finish (the minimum coating of the zinc comply with IS:2629 and IS:2633).
M/S. BASANTI ELECTRIC WORKS (BID ID -5816991)
Zenith Enterprise (BID ID -5809420)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .