Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.2 LAccepted-AOC A 111 JHILMIL COLONY EAST DELHI 110095 | SHAHDARA | DELHI | 110095 | ₹4.2 L | L1 | Accepted-AOC work order has been awarded |
| 2 | L2₹4.5 L+₹29,882.15 (7.15%)Rejected-Finance | ₹4.5 L+₹29,882.15 (7.15%) | L2 | Rejected-Finance Not L1 |
Tender Value
₹4.9 L
EMD Value
₹10,250
Closing Date
30 Mar 2026, 11:00 amClosed
EEE-II
MUNICIPAL CORPORATION OF DELHI OFFICE OF THE Ex. ENGINEER (ELECT)-II/SSZ 2 nd Floor Technical Laboratory Near NH-24 Ghazipur Delhi
Provision of lighting arrangement at SLF Ghazipur. Sub-Head Provision of Semi high mast pole with LED lights at gate no. 2 SLF Gazipur landfill site.
2026_MCD_273098_1
EEE-II/2025-26/79.4
Open Tender
Electrical Works
Percentage
60 days
work
Please refer to tender documents
4 documents required · 4 mandatory
₹590
₹10,250
27 Jul 2026
25 Mar 2026
30 Mar 2026
25 Mar 2026
30 Mar 2026
25 Mar 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1javascript:void(0)(javascript:void(0)塹ᴻ䡿ⲯ嶂藄挧ꮥ) | |||||
| 2Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required. | |||||
| 3Providing and laying eaarth connection From earth electrode with 6 SWG dia G.I wire in 15 mm Dia G.I pipe from earth electrode including connection with G.I thimble excavation and re-filling as required | |||||
| 4Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1KV grade of following size in the existingRCC/Hume/Stoneware/Metal pipe as required. (a) Up to 35 Sqmm | |||||
| 5Laying of one number PVC insulated PVC sheathed power cable of 1.1 KV grade of following size in the existing masonary open duct etc as reqd(a) up to 35 Sqmm . | |||||
| 6Fabrication,Supplying,Installation,testing,Commissioning of 12 mts.high mast System with its accessories ,Mast shaft shall be in one section , hot dip galvanized 4mm thick(Single dip ) inside & out sides &suitable for wind velocity as per IS 875 part3 .There shall be in longitudinal seam weld per section and No circumferential weld. It should also included accessories For High Mast head frame ,2 point suspension system,5x2.5 sqmm ccopper conductor with steel wire rope 5mm dia. (7/19construction) single drum winch ,galvanized lantern carriage arrangement suitable for 4/6 Nos. Flood Light luminaries symmetrically And its control gears boxes and lighting finial ,the mast shall have integral type manual tool mounted at the base compartment of its raising and lowering operation with foundation bolts and Anchor plate and control panel housing suitable RCC (1:2:4) shallow foundation of size 1m(L) x 1m wide and 2m deep i/c excavation of earth, providing cutting, bending and placing in position, reinforcement of cold twisted bars of 12 mm dia -2100mm long (approx.) - 16 nos.and reinforcement of cold twisted bar of 8 mm dia - 3700 mm (approx.) - 13 nos. (with 150 mm spacing) as required with positioning of foundation bolts and providing DWC HDPE pipe for cable entry & exit as required for the high mast considering The safe soil bearing capacity at site as 10T/sqm at 2mts. Depth with all material i/c 4Nos S.P MCB,63Amp.DPIsolator etc as reqd. Logo/Name of manufacturer shall be embossed on the pole. Galvanization as per relevant IS. | |||||
| 7Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket,bend, couplers etc. conforming to IS 14930, Part IIcomplete with fitting and cutting, jointing etc. in the existing trench, complete as required | |||||
| 8Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket,bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. | |||||
| 9Supply and fabrication of pole protection system made up of 8SWG steel wire mesh of size 25mmX75mm rectangular with 50mmx50mmx6mm MS angle iron for supporting the mesh i/c MV danger plate and grounding the protection system in suitable quality of CC etc. as req. | |||||
| 10Supplying, installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminum body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP- 66,IK-10, CRI >80 , under voltage and over voltage protection, EMIEMC as per CISPR -15 , lenses for beam angle 30 deg-120deg as per the application and the (LED,Driver & electrical circuitary) of minimum 50000 Burning Hours with project requirement deg., suitable tilt able fitting, life time 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy 105 <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-inCharge as per requirement. (Thermal management: heat sink ofaluminum housing such that LED junction temperature shall not rise above 90°C).150 WATT | |||||
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.46 MB
condition4.pdf
Tender Documents • 0.27 MB
BOQ_318740.xls
BOQ • 0.28 MB
viewsbd.pdf
Additional Documents • 15.52 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .