Loading…
Loading…
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
Refer Docs
EMD Value
₹1 Cr
Closing Date
17 Oct 2026, 11:00 am7d left
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
JGM DC CS
TCIL Bhawan GK 1 New Delhi 110048
Selection of Implementation Partner for Design, Supply, Installation, Implementation and Maintenance of ICT Components for Noida Safe City Project of Noida Authority, Uttar Pradesh
2026_TCIL_293758_1
TCIL/ITTIV/370/2026
Open Tender
Miscellaneous Works
EOI
1825 days
New Delhi
Please refer Tender documents.
2 documents required · 2 mandatory
₹11,800
Yes
Telecommunications Consultants India Limited
₹1 Cr
Yes
7 Oct 2026
7 Oct 2026
19 Oct 2026
7 Oct 2026
17 Oct 2026
7 Oct 2026
City Communication Network
Cost estimate for Bandwidth requirement as per the requirement - Connectivity from Field Equipment to ICCC / DC - Connectivity of all Police Thanas on Optic Fibre - Internet Requirement of 100Mbps at ICCC / DC Include below major activities but not limited to Supply of HDPE, DWC Duct,Optical Fiber Cabel,Joint Closer Box, Joint Chamber, LIU, SFP, Route Indicator, GI Pipe, POP Aggregation Switch etc and Implementation of Same
Integrated Command and Control Center (ICCC)
Asthetics
Control Room Interior As per Approximate minimum Area 14650mmx14650mm include below activities but not limited to Supply of Panelling, metal & glass partition, Doors, Ceiling, Lighting, Flooring, Paint, Wall Putty, Privacy Film etc. and implementation of the same Control Room Desk / Furniture As per approximate minimum Area include below activities but not limited to Supply of minimum 20 Control Desk , 5 Work Station Desk, 2 three seater Sofa, 2 Center Table, 32 Chair, 1 Conference Table, 2 Printer Table etc. and implementation of the same
Electrical
Distribution Board Cables Point Wiring Cable Trays and Raceways Earthing Miscellaneous
UPS 100KVA Minimum 30 Minutes backup in full load
GG Set 140KVA
Extra Low Voltage (ELV) System
Fire Alarm System (Different types of Sensors, Fire Alarm Panel, Cabling etc. )
Public Addressing System (10 Speakers with Amplifier, Microphone, Voice Alarm Controller and Wiring)
Indoor CCTV Surveillance System (12 Cameras with NVR, POE Switch, CAT 6 Cable and PVC Conduit)
Access Control System (6 Biometric Reader with electromagnetic door lock, attendance software, Push Button, CAT 6 Cable and PVC Conduit)
Data and Voice System (Cabling and accessories for 25 different touchpoints of seating locations)
Audio Video System for Conference Room - 75" Interactive Display Screen - PTZ Camera - DSP and Amplifier - Gooseneck, Mic and USB Extension - Cables and Connectors - Installation and Commissioning
Fire Fighting System
Sprinkler, Piping and Accessories Fire Extenguishers (2 Qty)
Novec Gas Suppression System (Server Room and UPS Room)
HVAC and VRF Air Conditioning System
Supply (Outdoor Unit + Indoor Unit) with Consealed Unit and Refnet Joint
Installation, Commissioning and Testing of Unit with other accessories (Power Cable, Cable Tray, Circular Inline Fans, Ducting etc.)
Control Room + Seating Area
Video Wall Cubes, Video Wall Controller with wall management software
Video Wall 65inch LED Cubes (2x2 Matrix) with Decoder for Community Surveillance Monitoring
Workstations (2 Screen)
Multifunction Laser Printer
IP Phones with Head Sets
Joysticks for PTZ Control (incl integrations)
MIC Controller Station for Panic Button and PA System
Softwares
Integrated Command and Control Center Solutions
Video Management System
Video Management System for Community Surveillance
Public Addressing and Emergency Panic Button System
Video Analytics (150 Licenses)
Face Recognition System (150 Licenses)
Automatic Number Plate Recognition (100 Licenses)
Variable Message Signboard Software
CTI Platform with IVRS System
Digital Forensics
Agentic AI Digital Investigation Platform (1 user)
Mobile Forensic Solution
Forensic Imaging and Analysis Tool
Open-Source Intelligence
Digital Twin Platform
Creation of Basemap and attribute linking for City 3D Model
Element and Network Management System
Holo Wall / Floor with Software
Data Centre
Rack Server (with actual number of Racks)
GPU Server (with actual number of Racks)
Primary Storage with SAN Switch/Controller (3PB)
Secondary Storage with Backup Software (1PB)
Backbone Spine
TOR cum Leaf Switch
Management Swtich (KVM)
Softwares (Virtualization, OS and DB)
Firewall cum Internet Router
Anti-Virus License
Hardware for IVRS Server + IPBX System with 4 PRI Trunk and 100 IP User License
PRI Line (Dual Redundancy)
Miscellaneous (Racks, Cable Management, Patch Cords, LIU etc)
Data Centre - Project Management and Implementation
Data Centre Equipment - Community Surveillance
Rack Server (with actual number of Racks)
Storage for Community Surveillance Monitoring (2PB)
Switch (24 Port Switch with 12 port Fiber)
TOR Switch
Softwares (Virtualization, OS and DB)
PoE L2 Access Switch for DC with KVM Module
Firewall with Inbuilt Router
CCTV based City Surveillance System
5MP Box / Bullet General Surveillance
2MP PTZ Camera
5MP ANPR Camera
IR Illuminator (to be provided external with ANPR cameras)
Local Processing Unit (LPU) (as per Bidder solution)
6.5 Meter Poles with Cantilever Arm (as per site requirements)
8 Port POE+ Switch with 2 SFPs (L2 Switch)
12U Pole Mounted Rack
LIU 6 Port
2KVA UPS with internal batteries (Backup for 2Hrs)
Fiber Patch Cords, Power Cables and CAT 6 Cables
Passive Components and Site Preparation (Supply and Services inclusive) - SFP Modules (set of Rx and Tx) - RJ 45 Connectors - HDPE Pipe (40mm) - Manual Moleing / Open Trenching for Laying of HDPE Pipe - Electrical Accessories such as Flexible Pipe, Clips, Tagging, Tops etc. - Bitumen and Reconcillation of site - Cost of Manpower for Maintenance of the Records, DPR, As build Drawings, Cordination, Per Location Cleaning, Dressing, and other expenses, Transportation, Local expenses, office etc
Passive Components and Site Preparation (Meter Connection and Electrical Connectivity) - Application Form - MCB Switch - HDPE Pipe (40mm) - Manual Moleing / Open Trenching for Laying of HDPE Pipe - Electrical Accessories such as Flexible Pipe, Clips, Tagging, Tops etc. - Bitumen and Reconcillation of site etc.
Chemical Earthing with 2mtr rod
Public Address System – IP based PA with speakers (One per Location with inbuilt Amplifier)
Emergency Panic Button (Call Box)
Variable Message Signboard (Display Size (W x H) 2.88Mx1.92M or Bigger / 9.45Fx 6.29F or Bigger)
Mounting Structure with Poles
Civil Work for VaMS
Peripherals for Police Thanas
2 Workstation with Single Screen 13 Police Thanas with 2 WorkStations Per Thanas
65 inch LED Display 13 Police Thanas with 2 Screens Per Thanas
2 IP Phones with Head Sets 13 Police Thanas with 2 Phones Per Thanas
Network Switch
6U Rack
Printer
Cabling and Implementation Services
Map Procurement and Processing
Base Map Procurement using Satellite Stereoscopic imagery and Processing.
Implementation Team
Project Manager (1 nos)
Solution Architect (1 nos)
Security & Surveillance Expert (1 nos)
GIS cum Data Expert (1 nos)
Command and Control Centre Expert (1 nos)
Network Architect (1 nos)
Data Centre Expert (1 nos)
Electrical Expert (1 nos)
Operations (Manpower Cost)
Operations
Operations
Operations
Operations
Operations
Maintenance
Maintenance
Maintenance
Maintenance
Maintenance
Maintenance
Total in Words
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.85 MB
Boq.xls
Other Document • 0.05 MB
RFPVolume1.pdf
Other Document • 2.42 MB
RFPVolume2.pdf
Other Document • 8.00 MB
RFPVolume3.pdf
Other Document • 2.83 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .