Loading…
Loading…
Tender Value
₹4.3 Cr
EMD Value
₹2.1 L
Closing Date
8 Apr 2026, 5:00 pmClosed
Similar tender results from the same govt authority in the past 3 years.
MR Yognarayan sahu(DFLT)
CE(Raipur)
CONSTRUCTION OF KISDI TO DEVALBHANTHA ROAD, LENGTH 4.20 K.M. I/C. CULVERTS AT DIST. MAHASAMUND( MAHASAMUND DN.).
187272
NIT No. 1084/TC/EinC/PWD/25-26
RESTRICTED TENDER
WORKS
6 days
CE(Raipur)
Required Past Technical Experience: AS PER NIT
Required Financial Turnover (in INR): AS PER NIT
Required Bid Capacity (in INR): AS PER NIT
7 documents required · 7 mandatory
Public Works Department (PWD)
WORKS
MR Yognarayan sahu(DFLT)
RESTRICTED TENDER
PERCENTAGE
A B
CE(Raipur)
PWD Circle-2,Raipur
Mahasamund Division
120
06
No
0
187272
8 Apr, 2026 5:00:00 PM IST
13 Apr, 2026 10:00:00 AM IST
18 Mar, 2026 5:00:00 PM IST
NIT No. 1084/TC/EinC/PWD/25-26
CONSTRUCTION OF KISDI TO DEVALBHANTHA ROAD, LENGTH 4.20 K.M. I/C. CULVERTS AT DIST. MAHASAMUND( MAHASAMUND DN.).
214600.00 INR
RTGS/CHALLAN (ONLINE) Internet Banking (ONLINE)
42915000.00
2
10 Apr, 2026 5:00:00 PM IST
42915000
AS PER NIT
AS PER NIT
AS PER NIT
0.00 INR
21d 0h 44m
7 documents required · 6 mandatory · 1 optional
₹0
₹2.1 L
17 Mar 2026
17 Mar 2026
13 Apr 2026
18 Mar 2026
8 Apr 2026
18 Mar 2026
10 Apr 2026
Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned up to a lead of 1000 meters including removal and disposal of top organic soil not exceeding 150 mm in thickness if required and as per relevant clauses of section-200. A. In area of light jungle
Granular Sub-base as per Table:- 400-1 Construction of granular sub-base by providing graded Material, , carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface watering, rolling and compacting with vibratory power roller at OMC to achieve the desired density, complete as per clause 401 A Plant mix method (with Mechanically crushed stone only) (a) For Lower Sub-base with with Grading-III Material
Prime coat (Providing and applying primer coat with oil based bitumen emulsion (SS-1, grade confirming to IS:8887) on prepared surface of granular Base including clearing of road surface and spraying primer using mechanical means as per clause 502. (i) on WBM/WMM surface @0.85 Kg/sqm.
Close Graded Premix Surfacing/Mixed Seal Surfacing (Mechanical means using minimum 40-60 TPH capacity of HMP. Providing, laying and rolling of close-graded premix surfacing material of 20 mm thickness using bitumen to the required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a Smooth wheeled roller 8-10 tonne capacity, and finishing to required level and grade, complete as per clause 508)With sensor paver finisher With bitumen Type B ( 13.2 mm to 0.09 mm size aggregates )
Providing and laying cement concrete for plain concrete/ reinforced concrete i/c form work, shuttering complete in as per drawings and specifications.( For Village roads) P.C.C. M-10
Providing and laying of a reinforced cement concrete pipe duct, 300 mm dia., across the road ( new construction ) , extending from drain to drain in cuts and toe of slopes to toe of slopes in fills, constructing head walls at both ends, providing a minimum fill of granular material over top and sides of RCC pipes as per IRC: 98- 2011, bedded on a 0.3 m thick layer of granular material free of rockpieces , outer to outer distance of pipes at least half dia of pipe subject to minimum 450 mm in case of double and triple row ducts, joints to be made leak proof, invert level of duct to be above higher than ground level to prevent entry of water and dirt, all as per IRC:98-2011 and approved drawings. Single row for one utility service
Providing and laying Reinforced Cement Concrete pipe NP 3 / prestressed concrete pipe. (Laying Reinforced cement concrete pipe NP3 /prestressed concrete pipe for culverts including fixing collar with cement mortar 1:2 but excluding bedding below pipes, excavation, protection works, backfilling, concrete and masonry works in head walls and parapets . ) 600 mm dia
Retro- reflectrorized Traffic signs (Providing and fixing of retro- reflectrorized cautionary, mandatory and informatory sign as per IRC:67-2012 made of rectro reflective type sheeting vide clause 801.3, fixed over aluminum sheeting of rfequired thickness supported on a mild steel frame of ISA 40 x 40 x 5 mm and mild steel angle iron post 75 mm x75 mm x 6mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45 cm x 45cm x 60cm, 60 cm below ground level as per approved drawing and painting all components of the Sings and supports as per clause 7.2 of IRC: 67 - 2012 )C) Made of Class - A High Intensity Super Engineering Grade Sheeting of Type II ( for ODR& Village Roads) With Aluminum Sheeting of 2 mm thickness 900 mm equilateral triangle
800mm x 600mm rectangular
With Aluminum Sheeting of 1.5 mm thickness 600 mm x 600 mm square
Direction and Place Identification signs with size more than 0.9 sqm size board. (Providing and erecting direction and place identification retro- reflectorized sign as per IRC:67-2012 made of retro-reflective type sheeting and vide clause 801.3, fixed over aluminum sheeting, 2 mm thick with area exceeding 0.9 sqm and fixed on a mild steel frame of size 40 x 40 x 5 mm,supported on a 2 Nos.mild steel angle iron post 75mm x 75mm x 6mm, 2 Nos. firmly fixed to the ground with M15 grade cement concrete 45cm x 45cm x 60cm, 60cm below ground level as per approved drawing) (C) Made of Class -A High Intensity Micro Prismatic Grade Sheeting of Type - I ( for ODR& Village Roads)
Kilo Meter Stone (Reinforced cement concrete M15grade kilometer stone of standard design as per IRC:8-1980, fixing in position including painting and printing etc) Ordinary Kilometer stone (Precast)
Hectometer stone (Precast)
Construction of RCC Drain/Cover/Chamber (i) Excavation for drain (Earth work in excavation for drain/chamber as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.)
Construction of RCC Drain/Cover/Chamber (ii)Construction of RCC drain/chamber cover, placing in position, providing shuttering and concreting by using concrete mixer, compaction by vibration etc complete as per drawings and technical specifications excluding reinforcement. with RCC M-20
Supplying, Fitting and Placing un-coated HYSD bar Reinforcement in drain/cover/chamber complete as per Drawing and Technical Specifications.
Plain cement concrete complete as per drawing and Technical Specifications PCC Grade M 15
Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.) Ordinary soil Up to 3 m depth
Providing and laying Pitching Stone/Boulder on slopes laid over prepared filter media including boulder apron laid dry in front of toe of embankment complete as per drawing and Technical specifications as per clause 2504.
Providing and laying Filter material underneath pitching in slopes complete as per drawing and Technical specification including trimming of slopes to proper profile and preparation of bed and as per clause 2504.
Providing and laying Reinforced Cement Concrete pipe NP 3 / prestressed concrete pipe. (Laying Reinforced cement concrete pipe NP3 /prestressed concrete pipe for culverts including fixing collar with cement mortar 1:2 but excluding bedding below pipes, excavation, protection works, backfilling, concrete and masonry works in head walls and parapets .) 1000 mm dia
Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead upto 1000 meters and as per relevant clauses of section-200 in Lime / Cement Concrete Lime Concrete, cement concrete grade M-10 and below
cement concrete grade M-10 and below
Removing all type of hume pipes and stacking within a lead upto 1000 meters including earthwork and dismantling of masonry works around pipes. Up to 1000 mm dia
Sand Filling in Foundation Trenches as per Drawing & Technical Specifications.
Plain/Reinforced cement concrete in open foundation complete as per drawing and technical specifications. Using concrete mixer PCC Grade M15
Plain/Reinforced cement concrete in open foundation complete as per drawing and technical specifications. Using concrete mixer PCC Grade M20
Plain/Reinforced cement concrete in open foundation complete as per drawing and technical specifications. Using concrete mixer PCC Grade M25
Supplying, fitting and placing HSD (High Strength Deformed Steel) bar reinforcement in foundation complete as per drawing and technical specifications as per section 1600.
Providing and laying Plain/Reinforced cement concrete in sub-structure complete as per drawing and technical specifications section 1500, 1700 and 2200 (Newly laid concrete shall be covered by gunny bags).Height upto 5m Using concrete Mixer P.C.C. Grade M-20
Providing and laying Plain/Reinforced cement concrete in sub-structure complete as per drawing and technical specifications section 1500, 1700 and 2200 (Newly laid concrete shall be covered by gunny bags).Height upto 5m Using concrete Mixer P.C.C. Grade M-25
Providing and laying Plain/Reinforced cement concrete in sub-structure complete as per drawing and technical specifications section 1500, 1700 and 2200 (Newly laid concrete shall be covered by gunny bags).Height upto 5m Using concrete Mixer R.C.C. Grade M-20
Furnishing and Placing Reinforced/Prestressed cement concrete in super-structure as per drawing and Technical Specification sections 1500, 1600 and 1700 (Newly laid concrete shall be covered by gunny bags).RCC Grade M30 For Solid Slab Super Structure Using Concrete Mixer Height upto 5m
Filler joint Providing & fixing 20 mm thick compressible fiber board (12 m long x 25 cm deep ) in expansion joint complete as per drawing & Technical Specification.
meter
Granular Sub-base as per Table:- 400-1 Construction of granular sub-base by providing graded Material, , carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface watering, rolling and compacting with vibratory power roller at OMC to achieve the desired density, complete as per clause 401 A Plant mix method (with Mechanically crushed stone only) (a) For Lower Sub-base with with Grading-IV Material
UOM Name
Percentage
Per mile
Siemens Per meter
Activity unit
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 1.07 MB
4355648977090759701_152305_9133295183868357873_125601_Guidelines_to_Bidders_EPS_v1.pdf
NIT • 0.13 MB
3049715688706244042_187272_Form A.doc
NIT • 0.15 MB
219646947973443112_187272_NIT.doc
NIT • 0.31 MB
8942136251411090272_187272_Notice.docx
NIT • 0.04 MB
678150178751355244_187272_BOQ.xls
BOQ • 0.16 MB
Download all tender documents and submit your bid