GE Kamptee
Garrison Engineer Cantt Area Kamptee 441001
SPL REPAIRS TO CRUMPLE JOINTS AND ROOF TREATMENT AND REPAIR MAINT OF SUNKEN FLOOR TREATMENT TO CERTAIN BLDG AND RELATED B/R WORKS OF KV SCHOOL KAMPTEE UNDER GE KAMPTEE.
2022_MES_571271_1
8467/E8
Open Tender
Civil Works
Item Rate
180 days
Kamptee
Class D Cat a (i)
5 documents required · 5 mandatory
₹500
Yes
GE Kamptee
₹67,460
Yes
22 Feb 2023
26 Dec 2022
6 Feb 2023
26 Dec 2022
28 Jan 2023
10 Jan 2023
Amount
Dismantling floor, hearth or wall tiles including cement mortar bedding, but not backing, removing serviceable tiles and rubbish off the premises complete all as specified and directed.
M&L for non skid ceramic coloured tiles 7 to 8mm thick (square/ rectangular) area of each tile exceeding 0.11sqm but n exceeding 0.18 Sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with and including 15mm thick screed bed or bedding layer in CM 1:4 finished fair and even for laying floor finishes/ tiles etc complete all as specified and directed.
M&L for glazed ceramic coloured tiles 300mm x 450mm x 7 mm thick / 350mm x 450mm x 7mm thick, on vertical surface such as skirtings/ dados, set and jointed in neat cement slurry and pointed in coloured cement to match over and including 10mm thick backing coat in CM 1:3 finished even and fair complete all as specified and directed.
Taking down cement or cement lime plaster, any description on brick or stone walls, etc including racking out joints, hacking for key, scrubbing down with water etc, complete all as specified and directed .
M & L for PCC 1:2:4, Type B0 (using 12.5 mm graded stone aggregate) 25 mm thick as in sunken floor using liquid integral WPC @ 200 ML/50Kg of cement (WPC shall be measured and paid separately.) complete all as specified and directed
M&L Rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortor 1:4 finished even and smooth (without using extra cement) complete all as specified and directed.
Supply only liquid integral water proofing admixture of make pidilite or its equivalent complete all as directed.
M & L for two coats of brush bond liquid compound of make Sika/fosroc or its equvalent water proofing coating over plastered surfaces of sunken portion (Sika/Fosroc chemical Ltd) complete all as per manufacturer instructions and directed by Engr-in-charge.
M&L for PCC type E2 1:5:10 (40 mm graded crushed stone aggreate) in foundation, filling and mass concrete complete all as specified and directed
S & F in repair vitreous china squating pan WC Orissa pattern white size 580 x 440 mm with integral foot rests with ‘P’ or ‘S’ trap including provn of lime concrete bedding complete all as specified and directed.
S & F in repairs EWC vitreous china wash down water closet (pedestal pattern) white with integral foot rests with 'P' or 'S' trap including provn of lime concrete or bedding complete all as specified and directed.
S & F Plastic water closet seat white, closed pattern with flat bottom and cover and mild steel C.P or aluminium hinging device complete all as specified and directed.
S & F in repairs Vitreous China W.H.B. white flat back of size 550 x 400 mm, including brackets and 32mm Waste fittings, brass,chromium plated for glazed ware sinks, basins, etc.with long screwed shanks,and fly-nuts, flange end bedded in red lead cement etc. complete all as specified and directed.
S&F in repair Pillar tap 15 mm dia, cast copper alloy, with capstan heads, chromium plated screwed down high pressure with or without lettered Hot or Cold with scrwed shanks and fly nuts, screwed for iron pipe and fixed complete all as specified and directed.
S&F in repair 10 ltr PVC valveless, syphonic action type, flushing cistern,low level, white, with inlet,ball valve, float and handle including brackets and Flush pipe of polyethylene of low or high density or PVC. 32 mm dia, for low level cistern complete all as specified and directed.
Supply & Fixing flush pipe of polythene of low or high density 32 mm PVC for low level flushing cistern complete all as specified and directed
Supply & Fixing PVC connection 15 mm dia, 450 mm long including check nut complete all as specified and directed
S & F in repair Cast iron Nahani trap 75 mm dia with grating including jointing to waste pipe fixed in cement concrete 1:2:4 type B1 complete all as specified and directed
S&F in repair 15mm bore bib tap cast copper alloy with crutch or butterfly handels screwed down for iron pipes or for brass ferrule all as specified and directed by Engr-in-charge.
S&F in repair 15mm bore angle/ stop valve fancy type chromium plated cast copper alloy screwed down high pressure screwed both ends for iron pipe or for union all as specified and directed by Engr-in-charge.
S & F in repair PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls 110 mm bore
S & F in repair PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls 75 mm bore complete all as specified and directed.
S & F stack clamp made out of 50x5 mm flat iron for 75 mm dia of pipe complete all as specified and directed.
S & F stack clamp made out of 50x5 mm flat iron for 100 mm dia of pipe complete all as specified and directed.
PVC (SWR) bend, ISI marked, any radius of 110mm bore complete all as specified and directed.
S&F PVC (SWR) bends ISI marked any radius of 75 mm bore with access door complete all as specified and directed.
S&F in repair PVC (SWR) branch piece single Y equal or unequal for 110 mm bore complete all as specified and directed
S&F in repair PVC (SWR) branch piece single Y equal or unequal for 75 mm bore complete all as specified and directed
Taking up or down 40mm dia steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and directed.
Supply & fix GI tubing 40 mm bore medium grade with all fittings and fixed to wall complete all as specified
Taking up or down 15mm dia steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and directed.
Taking up or down 20mm dia steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and directed.
Taking up or down 25mm dia steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and directed.
Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth complete all as specified and directed
S & F 15 mm bore galvanized steel tubes, medium grade with all fittings for water supply pipes, fixed to walls and ceilings or laid in floors complete all as specified and directed.
S & F 20 mm bore galvanized steel tubes, medium grade with all fittings for water supply pipes, fixed to walls and ceilings or laid in floors complete all as specified and directed.
S & F 25 mm bore galvanized steel tubes, medium grade with all fittings for water supply pipes, fixed to walls and ceilings or laid in floors complete all as specified and directed.
S&F in repair Vitreous China Urinal, Half stall type,white Urinal, half stall pattern including pipe, basin only including connections to flushing pipe and outgoing pipes fixed in repairs complete all as specified and directed.
S & F Urinal spreader of PTMT any colour for fixing with 15mm dia pipe (Minimum weight 60 gms) complete all as specified and directed.
Roughening surfaces of old concrete floor/terrace by picking incl. taking down existing detoriated / decayed tar felt or any treatment including loose surface, scraping with scraper, chiseling, scraping of surface with wire brush or any other method, sweeping clean & washing down with water to remove dust etc. and removing the scraped materials debris to a distance not exc. 50 m.
Demolition of unreinforced cement concrete in floors and pavings n. exc 15 cm thickness below or above ground level, complete all as specified and directed
M&L for 40mm thick cement concrete 1:2:4 type B-1 by using 20mm graded stone aggregate, as in padding, coping etc., laid to proper slope and gradient, using with water proofing liquid compound as per manufacturer instructions, finished even and fair without using extra cement, complete all as specified and directed. Note: Water proofing liquid compound shall be measured and paid separately under respective items.
Material & labour for provision of water proofing treatment by using APP torch on miniral/slate finished membrrance over roof and vertical surfaces including preparation of surfaces and applying oil based bituminous primer coat @ 0.30 ltr per sq m on clean and dry surface and then providing APP membrane having non woven. polyster film reinforcement with 3 mm thick and weight not less than 3 .00 kg/sq m and finished on top with mineral/slate finished torch on system laid with 100 mm & 150 mm over lap on side & end laps resepectely complete all as per manufacturers compound complete
M&L for Grouting in RCC wall/floor/roof through PVC nipples at a spacing of 45 to 60cm C/C including drilling injection points to a depth of 75-100mm, providing 10mm dia PVC nipples and pressure grouting using with and including cement mixed with plasticizing admixture like FOSROC(model CEBEX100) or PIDILTE (model 207 PIDICRET 8AM) @ 225gms/50kg of cement to fill up all capilaries/voids/honeycombing, nozzles to be sealed with the sealing with prssure of 2 to 4 Kg/sqcm and continued till refusal. After instructions complete all as specified and directed.Note-After ascertaining the location of leakage/seepage/dampness under relevant item shall be opereted of the required location.
M&L for 10 mm thick screed bed or bedding layer in CM 1:3 mixed with water proofing compound on concrete roof surface finished fair and even to maintain the proper slope of roof surface etc complete all as specified and directed.
Demolition of brickwork or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stone-work and precast concrete articles complete all as specified and directed.
M & L for brick work with fly ash bricks straight or curved on plan exc 6 mtr mean radius built in CM 1:6(Using old size brick) complete all as specified and directed.
All as per item No 47 here-in-above but half brick wall in CM 1:4 complete all as specified and directed.
Dismantling Plain, CGI Sheet corrugated of any gauge thickness including pattern roof coverings complete all as specified and directed by Engr-in-Charge.
S & F prepainted 0.50 mm thick gavalume aluminium zinc coating AZ-150 GI based plain steel coloured Sheet in profile pattern having tensile strength of 550 Mpa as in roof serrated ridge fixed with self tapping screws at every 30CM complete all as specified manufacturer instruction and as directed.
M&L rendering 10 mm thick in cement mortar 1:6 on walls, surface finished even & smooth without using extra cement etc. complete all as specified and directed.
M&L 15 mm thick rendering in two layers (first coat 10mm thick in cement mortar 1:6 and second 5mm thick in cement mortar 1:4 on external surfaces of walls & top surfaces of chajja/roof/ceiling mixed with and including liquid water proofing compound as per manufacturers' instn surface finished fair and even complete all as specified. (Note - Liquid water proofing compound shall be measrued and fixed separately)
M&L for 100 mm thick cement concrete Type D-2, 1:4:8 (40mm graded stone aggregate) as in sub base complete all as specified and directed.
Demolition of re-inforced cement concrete in any position not otherwise specifically provided for complete all as specified and directed by Engr-in-Charge.
M&L for form work to chullah hoods, chajjas, troughs and similar items including edges fair and rough complete all as specified and directed by Engr-in-Charge.
M&L for RCC nominal Mix Type B1 1:2:4 using (25mm graded stone aggregate) as in chajjas, slab, landings, balconies, canopies etc complete all as specified and directed by Engr-in-Charge.
Mild steel TMT 6 to 8mm dia cut to lengths bent to shape required including cranking, bending spirally for hooking and binding with MS wire( annealed) not less than 0.9mm dia etc all as specified & directed.
M&L for 20mm thick preformed bituminious filler board in Crumple joints and top 30 mm primed and sealed with sealing compound (Grade A) complete all as specified and directed.
M&L for 25x12mm thick flexible polysulphide sealent fixed in crumple joint complete all as specified and directed.
Demolition stone slabs and tiles of any description or thickness in laid bedded and pointed in any mortar floors, aprons etc and disposal of rubbish outside of MD land complete all as specified and directed.
M&L for Marble tiles 300mmx200mm x 20mm thick machine cut, bedded jointed and pointed with grey cement slurry including 20 mm screed bed in CM1:6 cutting and polishing types as approved and directed by Engr-in-Charge
Cutting out cracks to V-section in existing roofs or terracing, cleaning out, wetting, grouting with cement and sand slurry 1:3, complete all as specified and directed.
M&L Bitumastic gola, with 80/25 bitumen and coarse sand mixture, 1:3 by weight, 8cmx8cm at the junction of roofing to vertical surfaces
M & L for complete removal of existing treatment of wall/ceiling and applying two coats of oil emulsion distemper (acrylic) white or tinted or any colour including preparation of over one coat of putty surface on wall etc. complete all as specified and directed.
M & L for Preparing of new sur faces plastered or unplastered on wall / ceiling and Material & Labour for applying Two or more coatsof 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives@ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces. complete all as specified and directed
M & L for Preparing of new plastered sur faces or untreated sur faces on wall / ceiling and distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, ofrequired shade and colour complete, as per manufacturer's specification. Two or more coats over new surface , etc. complete all as specified and directed..
M&L for one coat of synthetic enamel paint over old painted wooden surfaces of any description over 10 cm in width or girth including preparation or surfaces complete.
M & L for preparation of old steel surfaces of any description over 10 cm width or girth & applying one coats of synthetic enamel paint complete all as specified and directed
S&F 0.50 mm th.Plain, Aluminium sheeting, Alloy as in Crumple joints, ridges, hips, valley gutter, drip and straight flashing (length and girth as fixed)complete all as specified and directed
S&F Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) 500 ltr hoisted and fixed in position incl top cover incl dismantling of water tank all as specified in SSR part-I
S&F in repairs ball brass valve high pressure with polythene float and fly nut complete screwed for iron pipe of size 20mm dia complete all as specifed and directed.
Refixing 15 mm dia old steel tubing and connections in new or old position (Walls, ceiling, floors, etc. complete all as specifed and directed.
Refixing 20 mm dia old steel tubing and connections in new or old position (Walls, ceiling, floors, etc. complete all as specifed and directed.
S&F in repairs Gun-metal, 20mm size globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed as specified and directed
Cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 complete all as specified and directed
M&L Preparation of new plaster surfaces on wall apply two coat of cement base paint over a coat of primer compete all as specified and directed.
NOTE:- SCHEDULE OF CREDIT (Amount shall be deducted offline from the total quoted amount to workout the net contract sum to be considered for acceptance.) [(-) Rs.21,445.00]
M/s Rahul Traders
M/s T.S.JOHAR
S D WAGHAMSHI
Bidder Name
S D WAGHAMSHI
M/s Rahul Traders
NORTH INDIA PEST CONTROL
M/s T.S.JOHAR
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .