Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.7 LAccepted-AOC RANGAPAHAR RAILWAY CROSSING GATE NO 1 DIMAPUR 797112 NAGALAND | DIMAPUR | NAGALAND | 797112 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹11.5 L+₹38,748.67 (3.50%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹11.8 L+₹72,128.47 (6.52%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
₹11 L
EMD Value
₹22,000
Closing Date
4 Jun 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE 869 EWS
GE 869 EWS PIN 913869 C/O 99 APO
COMPREHENSIVE MAINT TO OFFRS MD ACCN AT LMS
2024_MES_652012_1
8584/E8
Open Tender
Civil Works
Item Rate
210 days
LEIMAKHONG MIL STN
Please refer Tender documents.
2 documents required · 2 mandatory
₹500
GE 869 EWS
₹22,000
6 Jul 2024
2 May 2024
5 Jun 2024
2 May 2024
4 Jun 2024
16 May 2024
Amount
Schedule 'A'
Material and labour for applying two coats of oil bound distemper i.e Berger make Bison Acrylic Distemper using airless spray technology with max working pressure of 3300 PSI and capable of operating single spray gun with a max material hose length of 30 mtr the spray machine should be reputed manufacturer with pro guard technology and capability of tracking pressure and paint usage and certified by paint manufacturer and as mentioned in PS and accessories for applying distemper should be able to spray in hard to areas and penetration of distemper on the surface complete all as specified and directed. Note – Sanding of surface to be done by mechanical sander with 1500-2700 rpm, with internal dust extraction system for clean environment certified by paint manufacturer. Proper masking to be carried out before primer and paint application
Material and labour for two coats water based premium acrylic smooth exterior emulsion i.e. Berger make Weathercoat Long Life 10 (of approved colour) with PU & silicon additives, excellent dirt pick up resistance with low VOC less than 50 gram/litre as per the LEEDS specifications, Anti Algae properties in two coats @1.79 ltr (undiluted)/ 10 sqm diluted with water as per manufacturer instructions applied over priming coat with fully automatic airless spray machine of paint application with a flow speed of min 1 ltr per minute having pressure of 3300 PSI. Allow 6-8 hrs to dry the surface in both the coats of paint complete all as specified and directed
Preparation of old decorated surfaces of walls including brooming, down scraping down smoke soot, moulds, masss and efflorscent salts and trading oil and greasy spots & removing of nails mark & applying one coat of white wash on wall on old decorated surfaces complete all as specified and directed.
Preparation of old decorated surfaces of ceiling including brooming, down scraping down smoke soot, moulds, masss and efflorscent salts and trading oil and greasy spots & removing of nails mark & applying one coat of white wash on ceiling on old decorated surfaces complete all as specified and directed.
Mateirial & labour for Preparation of old decorated surfaces of wall including washing, rubbing down and stopping of distempered and painted surfaces ,brooming , scraping down. Smoke spot, moss, efflorescent salts, trading oil, grasy spots and stopping nails marks by applying white cement base putty in patches as required and applying one coat of oil emulsion distemper all as specified and directed.
All as per item No.5 here-in- above but two coat of oil bound distemper complete all as specified and directed.
M&L for preparation of old painted surefaces of wood based material exc 10 cm width or girth & applying one coat of synthetic enamel paint on wooden surfaces.
M&L for Preparation of old painted surefaces of wood based material n. exc 10 cm width or girth & applying one coat of synthetic enamel paint on wooden surfaces.
M&L for preparation of old painted steel surfaces of any description, over 10 cm in width or girth, not otherwise described and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L for Preparation of old decorated steel surfaces of any description, n.exc 10cm in width or girth,not otherwise described & applying one coat of synthetic enamel paint all as specified and directed.
Material & labour for preparing old wooden surface by cleaning & wiping filling with wooden filler and applying a coat french polishing on surfaces of any description, width or girth complete all as specified and directed
Taking down cement plaster of any thickness on brick or stone walls etc including raking out joints, hacking for key and scrubbing down with water built in cement mortar complete all as specified and directed.
M&L for rendering 10mm thick in cement mortar (1:6) on fair faces of brickwork or concrete surfaces of wall finished even and fair without using extra cement complete all as specified and directed.( Source of sand-Dimapur sand)
M&L for preparation of new plastered surfaces of wall and applying two coats of oil bound distemper over a coat of chalk whiting complete all as specified and directed.
M&L for rendering 5mm thick on fair face of brick work or concrete surface of ceiling in CM 1:3 finishing even and smooth without using extra cement complete all as specified and as directed.
M&L for preparation of surfaces plastered or unplastered new surface on ceiling and applying three coats of white washing complete all as specified and as directed.
S&F in repair sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs,washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete all as specified and as directed.
S&F in replacement stainless steel plate rack of size 24" x 36" x 10" complete all as specidfied and directed.
Disconnecting existing tanks,exc 250 & n exc 500 setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position complete all as specified and as directed.
S&F in repairs water storage tank ISI marked of capacity 500 ltrs hoisted and fixed in position including ball brass valves of 20mm dia, high pressure with polythene float and fly nut complete, screwed for iron pipe of brass ferrule and fixed in 20mm bore GI tube etc complete all as specified and directed.
S&F in repair Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specidfied and directed.
Hacking out old brocken glass (any thickness, size,quality or description) from wooden frames or steel frame, concrete or brick surrounds, glazed with putty or fixed with beads complete all as specidfied and directed.
S&F 3mm thick sheet glass ordinary quality with oil putty in square n. exc. 0.5m in each pane complete all as specidfied and directed.
S&F floor door stopper of aluminium alloy body and tongue with hard drawn steel spring with 140mm overall length of cover plate complete all as specidfied and directed.
Dismantling boarding any description in any position complete all as specidfied and directed.
M&L 18/19mm particle board medium density flat pressed single line layer type or three layer type with BWR type adhesive fixed with screws to timber frame work complete all as specidfied and directed.
M&L 0.9mm decorative laminated type 1, of surface finish, colour and pattern as approved, fixed with approved adhesive as per manufacturer's instructions complete all as specidfied and directed.
S&F 30m wide continuous (piano) hinges, mild steel, bright finish or electrogalvanised complete all as specidfied and directed.
S&F 40mm dia cupboard knobs fixed with nuts, screw and washer of mild steel bright finish complete all as specidfied and directed.
S&F Magnetic door catches of standard size for cupboard doors approved by Engr-in-Charge complete all as specidfied and directed.
S&F in repair vitreous china squatting pan, orissa pattern size 580x440 white with integral foot rest (excluding flushing cistern and flush pipe) complete fixed complete all as specidfied and directed.
S&F in repair light coloured vitreous china WHB white oval shape of 550mmx400mm (minimun) on new brackets excluding taps, 32mm dia waste china & plug including bracket etc complete all as specified and directed.
S&F in repair for Pillar taps, 15mm dia cast copper alloy with capstan heads chromium plated but fancy type down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and flynuts, screwed for iron pipe and fixed complete all as specified and directed.
S&F PVC (SWR) floor trap with grating with incl jointing to waste pipe fixed in cement concerete (1:2:4) Type B1 diameter of outlet pipe 75mm complete all as specidfied and directed.
S&F in repair PVC connection 15x600mm long with PTMT nuts & bolts complete all as specidfied and directed.
S&F in repair bib fancy type tap cast copper alloy CP brass 15mm bore of pipe complete all as specified and directed.
S&F in repair for stop valve 15mm dia fency type chromium plated with long sank and cup concealed type complete all as specified and directed.
S&F in repair for brass chromium plated shower rose 125mm size with or without swivel joints, any size, including fixing to steel pipe or union any colour for fixing with 15mm pipe complete all as specidfied and directed.
S&F in repair CP brass towel rail 20mm dia 60cm long incl bracket fency type heavy weight as approved by Engr-in-charge complete all as specidfied and directed.
Taking up or down 15mm dia steel tubing and connections includig cleaning for re-fixing or removal to store complete all as specified and directed.
S&F GI tubing 15mm bore, medium grade with all fittings and fixed to walls and ceilings or laid in floors including cutting chasing in wall etc complete all as specified and directed.
Refixing of 15mm steel tubing and including cleaning in positon (walls, ceiling and floor etc complete all as specidfied and directed.
S&F PVC soil, waste and rainwater (SWR) drainage pipes 110mm bore single socketd in any length with rubber rings joints fixed to wall and laid in floors weight of pipe not less than 0.70 Kg/Rm complete all as specidfied and directed.
S&F PVC soil, waste and rainwater (SWR) drainage pipes 75mm bore single socked in any length with rubber ring joints fixed to wall and laid in floors weight of pipe not less than 0.70 Kg/Rm complete all as specidfied and directed.
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store & rubish of the permises complete all as specidfied and directed.
M&L for non skid coloured ceramic tiles 7 to 8mm thick (Square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in CM 1:4 complete all as specified and directed by engr-in-Charge
M&L for PCC 1:4:8 type D2 (using 40mm graded stone aggregate) 75mm thick as in sub base complete all as specidfied and directed.
M&L for 25mm thick PCC 1:2:4 type B1 (using 20mm graded stone aggregate) as in levelled course finish even and fair for tile finishes specified and directed
M & L for Glazed Coloured Ceramic tiles in vertical surface 350x250x7mm / 450x350x7mm thick set and joint in neat cement slury and pointed in white or colour cement to match over and including 10mm thick plaster in CM 1:4 as backing coat to receive tiles complete all as specified and directed.
S&F in repairs fancy type Harrison rails, andodised aluminium alloy with fixing brackets, stops, rollers etc, of 20mm dia for window and doors with curtain rings and decorative doom holders fixed to wall with screw complete all as specidfied and directed.
Taking down copper/ aluminium point wiring ie. light, fan, socket or power/points complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc. and making good disturbed surfaces of ceiling, walls, floors etc complete all as specified and directed.
Material and labour for point wiring concealed type in existing concealed PVC conduit with 2 single core 1.5 sqmm (nominal area) FRLSH PVC insulated unsheathed cable, 1100 volts grade multistranded copper conductor cable with using new sunken type Pre - coated GI sheet pressed steel box including modular frame with cover plate for mounting modular switch socket etc incl all accessories and using single core 1.5 sqmm (nominal area) FRLSH PVC insulated unsheathed cable, 1100 volts grade multistranded copper conductor cable (In green colour) as in earth wire connected to common earth dolly complete all as specified and directed. Note : (i) The quoted rates shall be deemed to be inclusive of sunction boxes/modular cover plate and cutting chases in brick walls/pillars etc for concealing the depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface to match with the portion of point wiring at for covering / fix sunken boards/terminal boxes/junction boxes of any shape and size . (ii) Fittings like switches sockets regulators, lamp holders light fittings shall be measured and paid for seperatly of cencern item of Sch’A’. One light point controlled by one/way switch complete all as specified and directed.
One ceiling/exhaust fan point controlled by one way switch
One socket outlet 5 Amps 3 pin on same board with other switch
One socket outlet 5 Amps 3 pin on independent board with cable of 1.5 sqmm size complete all as specified and directed
All as per item No. 53 here-in-above but with cable size 2.5 Sqmm for one 3 pin, 15 Amps socket outlet on independent board and multistrand PVC insulated copper earth continuity conductor of size 2.5 Sqmm complete all as specified and directed.
Material and labour for point wiring concealed type with 2 single core 1.5 sqmm (nominal area) FRLSH PVC insulated unsheathed cable, 1100 volts grade multistranded copper conductor cable in concealed PVC conduit (medium grade) of 20mm dia all as specified and directed with using new sunken type Pre - coated GI sheet pressed steel box including modular frame and cover plate for mounting modular switches, sockets and fan regulators etc incl all accessories and using one single core 1.5 sqmm (nominal area) FRLSH PVC insulated unsheathed cable, 1100 volts grade multistranded copper conductor cable (In green colour) as in earth wire connected to common earth dolly complete all as specified and directed. Note : (i) The quoted rates shall be deemed to be inclusive of sunction boxes/modular cover plate and cutting chases in brick walls/pillars etc for concealing the depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface to match with the portion of point wiring at for covering / fix sunken boards/terminal boxes/junction boxes of any shape and size . (ii) Fittings like switches sockets regulators, lamp holders light fittings shall be measured and paid for seperatly of cencern item of Sch’A’. One light point controlled by one/way switch.
One ceiling/exhaust fan point controlled by one, one way switch
One socket outlet 5 Amps 3 pin on same board with other switch
One socket outlet 5 Amps 3 pin on independent board with cable of 1.5 sqmm size complete all as specified and directed
One bell point controlled by one way switches complete all as specified and directed.
All as per item No.58 here-in-above but with cable size 2.5 Sqmm for one 3 pin, 15 Amps socket outlet on independent board and multistrand PVC insulated copper earth continuity conductor of size 2.5 Sqmm complete all as specified and directed.
M&L for point wiring with two single core 1.5 sqmm (nominal area) FRLSH PVC insulated unsheathed cable, 1100 volts grade multistranded copper conductor cable and incl PVC casing and capping of suitable size fixed on surface all as directed with using new sunken type precoated GI/ pressed steel box/terminal boxes including modular frame and plate for mounting fittings/junction boxes incl all accessories and using one single core 1.5 sqmm (nominal area) FRLSH PVC insulated unsheathed cable, 1100 volts grade multistranded copper conductor cable as in earth wire connected to commen earth dolly complete all as specified and directed. Note : (i) The quoted rates shall be deemed to be inclusive for fixing the PVC casing caping to surface with using PVC of covering sunken boards /terminal boxes/junction boxes of any shape and size with 3 mm thick suitable GI screws and cup washers. (ii) Fititngs like switches, sockets, regulators lamp holders light fittings shall be measured and paid appropriate item of schedule ‘A’ One light point controlled by one way switch.
One ceiling/exhaust fan point controlled by one, one way switch
One socket outlet 5 Amps 3 pin on same board with other switch
One socket outlet 5 Amps 3 pin on independent board with cable of 1.5 sqmm size complete all as specified and directed
One light point controlled by two way switches complete all as specified and directed
One bell point controlled by one way switches complete all as specified and directed.
All as per item No.64 here-in-above but with cable size 2.5 Sqmm for one 3 pin, 15 Amps socket outlet on independent board and multistrand PVC insulated copper earth continuity conductor of size 2.5 Sqmm complete all as specified and directed.
S&F modular switch piano, 6 Amps, single pole, one way complete all as specified and directed.
S&F modular switch piano, 16 Amps, single pole, one way complete all as specified and directed.
S&F modular socket outlet 2/3 Pin 6 Amps combined 2 module complete all as specified and directed.
S&F modular Switch Socket multipurpose 3 pin 16 Amps and 3 pin 6 Amps combined 2 module complete all as specified and directed.
S&F Bell push switch Modular type single pole one way 6 Amp 240 Volts complete all as specified and directed
S&F Modular step type regulator 120W, 2 module ,heavy duty, 240 volts complete all as specified and directed
S&F Ceiling rose, 3 phase/ PVC/ polycarbonate, isolated body complete all as specified and directed.
M&L for Lamp holder, PVC/Polycarbonate type with cord grip cap suitable for pendent/Angle type including one lamp complete all as specified and directed.
S&F in repair for submain wiring with single core 4.0 sqmm PVC FRLS insulated unsheathed cable multi stranded copper conductor drawn through and inclduing PVC casing / capping of suitable size with all fittings and fixing accessories on roof , walls, ceiling etc including 4.00 Sqmm PVC insulated unsheathered one core multistranded copper condutor earth wire complete all as specified and directed. (Note : Two run of single core cable and one run earth wire will be measured as one length)
S&F in repair Concealed Galvanised (GI) metal flush Boxes Modular 3 module concealed including frame, cover plate and making good the disturbed surface by using white cement complete all as specified and directed.
Supply and fix in repair socket outlet, 3 pin, flush type, 5 Amps, complete all as specified and as directed.
Supply and fix in repair socket outlet, 3 pin, flush type, 15 Amps, complete all as specified and as directed.
S & F in repair 15 Amps Switch flush type complete all as specified and directed.
S & F in repair switch socket combination 2 in 1, 3 pin, 5 and 15 Amps flush type universal 240 Volt complete all as specified and directed
S&F in repair switch socket combination 3 pin 16 Amp flush type complete all as specified and directed
S&F in repair switch piano flush type single pole one way 5 Amp 240 Volts complete all as specified and directed
S & F in repair switch piano flush type single pole two way 5 Amp 240 Volts complete all as specified and directed
S&F in repair modular switch piano, 6 Amps, single pole, one way complete all as specified and directed.
S&F in repair modular switch piano, 16 Amps, single pole, one way complete all as specified and directed.
S & F in repair modular switch two way 6 Amps 1 module 240 Volts complete all as specified and directed
S & F in repair modular bell push way 6 Amps 1 module 240 Volts complete all as specified and directed
S & F in repair modular socket outlet 6Amp 3 pin 2 module 240 Volts complete all as specified and directed
S & F in repair modular socket outlet 6/16 Amp 5 pin 2 module 240 Volts complete all as specified and directed
S&F in repair Modular step type regulator 120W, 2 module ,heavy duty, 240 volts complete all as specified and directed
S&F in repair Bell push flush type single pole 5 Amp 240 Volts complete all as specified and directed.
S&F in repair bell Buzzer, Ding Dong Type , AC 230 Volts single pole complete all as specified and directed.
S&F in repair Ceiling rose, 3 phase/ PVC/ polycarbonate, isolated body complete all as specified and directed.
S&F in repair of Lamp holder, PVC/Polycarbonate type with cord grip cap suitable for pendent/Angle type complete all as specified and directed.
Supply and fix in repair stepped type electronic fan regulator flush type, 230 Volt, 5 speed control complete all as specified and directed.
S&F in repair sheet metal enclosure for MCB’s distribution board, 240 Volts, 8 ways single pole and neutral including 200 Amps rated busbar, neutral link, din rail double door Type for breaking capacity 10 KA complete all as specified and directed.
S&F in repair sheet metal enclosure for MCB’s distribution board, 240 Volts, 4 ways single pole and neutral including 200 Amps rated busbar, neutral link, din rail double door Type verticle for breaking capacity 10 KA complete all as specified and directed.
S & F in repair single pole and neutral enclosure with a two pin and earth plug and socket complete with one single MCB SP 20 Amps 10 KA complete all as specified and directed.
S&F in repair MCB single pole 06 to 32 Amps, ‘C’ series 240 Volts, breaking capacity 10KA complete all as specified and directed.
S&F in repair MCB single pole and neutral 32 Amps, ‘C’ series 240 Volts, breaking capacity 10KA complete all as specified and directed.
S&F in replacement of MCB single pole and neutral 40 to 63 Amps, ‘C’ series 240 Volts, breaking capacity 10KA complete all as specified and directed.
S&F in repair PVC rectangular block for mounting switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet cover of size 100mm x 100mm x 50 mm complete all as specified and directed.
All as per serial item No.106 here-in-above but for size 175x100x50 mm deep complete all as specified and directed.
All as per serial item No.106 here-in-above but for size 250x200x50 mm deep complete all as specified and directed.
All as per serial item No.106 here-in-above but for size 350x200x50 mm deep complete all as specified and directed.
S&F in repair single phase electronic meters temper proof LCD display with polycarbonate cover 230 V,10-60Amp, accuracy class-I 50Hz, conforming to IS 13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWH Class 1 complete all as specified and directed.
S&F in repair of PVC conduit size 25mm Rigid non-metallic PVC conduit exclusive of boxes (junction/terminal) but inclusive of all tees, bends,elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc complete all as specified and directed
Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc. and making good, cutting exceeding 20cm girth complete all as specified and directed
S & F in repair LED light fitting mirror type with high out put diffuser 2 feet,10 watt 220 V AC decorative type white/warm with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete complete all as directed by Engr-in-charge.
S & F in repair LED lights fitting 1x 20W, 220V, AC decorative box type white/warm with driver, holder including LED tube light 20W connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as directed by Engr-in-charge.
S & F in repair LED lights fitting 1x 20W, 220V, AC LED Batten with Opal Diffuser, IP20, Inbuilt Motion Sensor based Auto Dim/Brightness decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as directed by Engr-in-charge.
S&F in repair LED builidng security light fitting 25 Watt 230 V, AC out door type with high pressure dia cast aluminium hosing and heat resistant complete with driver , lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
S & F in repair LED bulb Lamp 09/10 Watts Retrofit B22 holder type base wth polycorbonate diffuser and alluminiun heat sink complete all as specified and directed.
Taking down and dismantling of storage type water geysers of 25 ltrs capacity any type any make, any model, from its existing location, transportation to work shop for repairs and transportation back and reinstallation of geyser as per technical instructions and as directed by engr-in-charge and including the following:- (a) Dismantling complete geyser and carrying out complete overhauling i.e; disconnecting electric supply and opening the heating plate, inner assembly, descaling complete assembly including heating element or otherwise. Replacement of defective heating element inlet and outlet tubes and refixing the assembly with gasket of good quality and tightening the nuts properly, reassembling geyser with all safety devices as specified in technical instructions and as directed by Engineer -in- Charge complete. Notes:- (i) Spare parts, safety devices with its required accessories shall be measured and paid seperately .
All as per serial item No. 118 above but for capacity 50 ltrs complete all as specified and directed.
Supply only following spare parts of geysers 50/25 Ltrs capacity (120.01) Heating element 1.5/2 KW suitable for operation on 230V AC 50Hz
(120.02) Thermostat 40 to 90 degree centigrade varying capactiy for 25/50 Ltrs capacity Geyser.
(120.03) Stainless steel flexible conneciton pipe with brass check nuts complete as per site requirement all as specified and directed by Engineer-In-Charge.
(120.04) Indicator lamp assembly for geyser complete all as specified and directed by Engr-In-Charge.
(120.05) Syphon assembly suitable for 25/50 ltr geyser complete including nuts and washer complete all as specified and directed.
(120.06) Geyser brass tank for 25/50 ltr geyser complete including nuts, washer, glass wool etc complete all as specified and directed.
S&F in repair 15 Amp plug top complete all as specified and directed.
S&F in repair earth industrial plug top for socket for industrial socket metal glad suitable for 16 Amps metal glad MCB DB complete all as specified and directed.
S&F in repair industrial socket metal glad suitable for 16 Amps 240 volts metal glad MCB DB complete all as specified and directed.
S&F in repair 4 sq mm 3 core flexible copper cable for maintenance of geyser, and cooling appliances complete all as specified and directed.
S&F in repair 23/.0076 sqmm 2 core flexible copper cable for maintenance of light/ fan etc complete all as specified and directed.
M&L for attending complaint of ceiling fan/exhaust fan/air circulator/ cabin fan such as hanging/dismantling/loose connection etc complete all as specified and directed
S&F in repair of BLDC fan driver suitable for any make , type & sweep BLDC ceiling fan complete all as specified and directed.
S & F in repair capacitor of 2.5 MFD of ISI marked complete all as specified and directed.
M&L in repair of rewinding of ceiling fans 1200/1400mm sweep, strip opening and removal of burnt winding wire, rewinding the fans with suitable size of heavy grade (ISI mark ) copper winding wire, duly providing leathoride sheets, cotton tape, insulation sleeves, varnish, etc 6 month waranty period shall given by the dealer/contractor after repair, complete as reassembling including taking down and refixing at site and shifting/transporting to wksp including testing complete all as specified and directed
M & L in repair of rewinding of Exhaust fan 300 mm sweep, strip opening and removal of burnt winding wire, rewinding the fans with suitable size of of heavy grade (ISI mark ) copper winding wire, duly providing leathoride sheets, cotton tape, insulation sleeves, varnish, etc 6 month waranty period shall given by the dealer/contractor after repair, complete as reassembling including taking down and refixing at site and shifting/transporting to wksp including testing complete all as specified and directed
M&L in repair of fan bearing 6201/6202 of ceiling fan of any capacity any size complete all as specified and directed Note: Replacement of bearing to be carried out at E/M complaint cell at LMS only exceptional case where lathe work is required then only fan to be taken at workshop.
M&L in repair of bearing/bush of exhaust fan/cabin fan/air circulator of any capacity any size complete all as specified and directed Note: Replacement of bearing to be carried out at E/M complaint cell at LMS only exceptional case where lathe work is required then only fan to be taken at workshop.
S&F in repair exahust fan louvers of 300mm sweep with locking nut complete all as specified and directed
Manipur Steel Industries(INDIA)
MANI PRASAD GUPTA
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .