Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹63.9 LAccepted-AOC A 26TH FLOOR PLATINUM PLAZA DISTRICT BHOPAL M P | BHOPAL | BHOPAL | MADHYA PRADESH | 462001 | L1 | Accepted-AOC Quoted rates lowest | |
| 2 | L2₹68.7 L+₹3.8 L (5.88%)Rejected-Finance | L2 | Rejected-Finance Quoted rates not lowest | |
| 3 | L3₹71.1 L+₹6.3 L (9.65%)Rejected-Finance 51 23 RAJINDER NAGAR NEW DELHI 110060 | NEW DELHI | NEW DELHI | DELHI | 110060 | L3 | Rejected-Finance Quoted rates not lowest |
Tender Value
₹65.2 L
EMD Value
₹1.2 L
Closing Date
12 Oct 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE DELHI CANTT
HQ CWE DELHI CANTT-10
CERTAIN PETTY REPAIR, PERIODICAL SERVICES AND EM SERVICES AT CARIAPPA PARADE GROUND UNDER GE EAST DELHI CANTT-10
2021_MES_474103_1
CWE/D-29/2021-22
Open Tender
Civil Works
Item Rate
120 days
Delhi Cantt
As per NIT
7 documents required · 7 mandatory
₹1,000
GE EAST DELHI CANTT
₹1.2 L
Yes
30 Oct 2021
9 Sept 2021
13 Oct 2021
9 Sept 2021
12 Oct 2021
30 Sept 2021
60 days
Amount
Taking down shutters of any description not exceeding 1.0 sqm each complete all specified and as directed.
Taking down shutters of any description exceeding 1.0 sqm but not exceeding 2.00 Sqm each complete all specified and as directed.
Re-securing or easing and adjusting shutters of any description not exceeding 1.0 sqm without taking off shutters from the frame complete all specified and as directed.
Taking down chowkats or frames with shutters (without taking off shutters from the frames) not exc. 1.5 Sqm each and removing to store complete all as specified and as directed.
Taking down chowkats or frames with shutters (without taking off shutters from the frames) exc. 1.5 sqm but n.exc 4 sqm each and removing to store complete all as specified and as directed.
S & F for flush shutters 30 mm thick solid core constructions with block boardcore , ply wood face panels commercial type on both side complete all as specified and as directed.
S & F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification and drawing complete all as specified and as directed.
Maint/repair/greasing of old rolling shutter incl fittings, accessories as reqd to smooth working of rolling shutter complete all as specified and as directed. (Note :- Greasing/Oiling and any fittings if reqd to smooth functioning of rolling shutter deemed to include in quoted rates.
S & F 150mm long mild steel barrel tower bolts of extruded section complete all as specified and as directed.
S & F mild steel pressed oval type handles stove enamelled black for doors 150 mm long complete all as specified and directed.
S & F butt hinges medium weight colled rolled mild steel 100 mm and fixed or incl welded to MS frame all as specified and as directed.
S & F in repairs butt hinges medium weight colled rolled mild steel 100 mm and fixed or incl welded to MS frame all as specified and as directed.
S & F in repairs brass CP Tubular towel rail, 20mm dia, D type, 60cm long between flanges complete.
S & F in repairs Galvanised mild steel wire cloth 0.63mm nominal dia of wire and average width of aperature 1.4mm and fixed to doors and widows with necessary 12mm iron flats with welding complete all as specified and directed. (Rates are inclusive of welding and supply of flats including reqd nutbolts wherever required)
Taking down cement or cement lime plaster of any description on brick or stone walls and concrete surface etc including raking out joints hacking for key scrubbing down with water etc complete all as specified.
M & L for rendering 15mm thick on fair faces of brick work or concrete surfaces (Cement plaster 1:4) finished even and smooth without using extra cement complete all as specified and as directed.
M & L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in CM1:6 finished even and smooth without using extra cement complete all as specified and as directed.
M & L for Washed stone grit plaster on exterior walls in two layers, under layer 12mm cement plaster 1:4 (1 cement: 4 coarse sand ) furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 3 Kg of cement per square metre, top layer 15mm cement plaster 1:1/2:2 (1 cement: 1/2 coarse sand : 2 stone chipping 10mm nominal size) in panels with groove all around as per approved pattern (groove of uniform size 15mm wide and 15mm deep in the top layer of washed stone grit plaster as per approved pattern using wooden battens, nailed to the under layer including removal of wooden battens, repair to the edges of panels and finishing the groove) complete including scrubbing and washing, the top layer with brushes and water to expose the stone chippings complete all as specified.
S & F 3mm thick sheet glass, ordinary quality and glazing with wooden beading not exc 0.5 Sqm in each pane all as specified and directed including hacking out old broken glass (any thickness, size, quality or description) from wooden or steel frame glazed with putty or fixed with beads.
S & F tubing 15mm bore medium grade, galvanised, ISI marked with all fitting and fixed complete to walls and ceilings or laid in floors including taking up or down GI tubing 15mm bore and connections complete all as specified and directed.
S & F tubing 20mm bore medium grade, galvanised, ISI marked with all fitting and fixed complete to walls and ceilings or laid in floors including taking up or down GI tubing 20mm bore and connections complete all as specified and directed.
S & F Rotational moulded polyethylene water storage tanks 500 lts capacity, tripple layered (cylindrical vertical with closed top) hoisted and fixed in position including 20 mm dia Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed including taking out existing unserviceable overhead tank of any description complete all as specified and directed.
S & F Rotational moulded polyethylene water storage tanks 1000 lts capacity, tripple layered (cylindrical vertical with closed top) hoisted and fixed in position including 20 mm dia Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed including taking out existing unserviceable overhead tank of any description complete all as specified and directed.
S & F in repair precast cement concrete type B0 1:2:4 (12.5 mm graded aggregates) louvres and jallies, 50mm thick set in CM (1:4) (measured solid), including all mouldings but excluding frame (Pre cast frame shall be measured and paid seperately) complete all as specified and directed.
M & L for precast coping type B-0n, 1:2:4 fixing with cement mortat 1:4 complete.
S&F in repairs bib taps cast copper alloy fancy type, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe15mm bore all as specified and directed.
S&F in repairs Pillar taps cast copper alloy fancy type chromium plated with capstan heads screwed down high pressure with long screwed shanks and fly nuts, screwed for iron pipe of 15 mm bore all as specified and directed.
S&F in repairs stop valve cast copper alloy fancy type chromium plated , screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe of 15mm bore all as specified and directed.
S & F in repairs PTMT Angle valve 15mm bore complete.
S & F in repair vitreous china pedastal pattern water closet including flush pipe & seat cover 'P' or 'S' trap complete all as specified and directed.
S & F in repairs water closet (Squat Pattern) complete incl provn of cement concrete bedding Orissa pattern size 580 x 440mm white with integral foot rests (excluding flush pipe or flushing cisterns) including connection to trap and flushing pipe anti syphonage pipe etc complete and making good to floor as directed.
S & F in repairs PVC low level flushing cistern white 10 litrs capacity and connections to pipes all as specified and directed.
S&F in repairs 75mm dia brass chromium plated shower rose with neck and swivel joints fancy type suitable for 15mm bore GI pipe all as specified and directed.
S & F in repair counter type vitreous china wash hand basin (WHB) white size 550mmx400mm complete including provn of a pair of mild steel angle iron brackets of suitable size duly painted, 32mm dia CP waste coupling , PVC waste pipe and cutting for pinning ends of brackets in wall etc complete.
S & F sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with CP bracket guard and railing 60cm long , complete.
S & F in repairs 15mm dia, 60 cm long PVC connection with brass ferrules on both ends all as directed.
S & F Stainless Steel grating plate with central hole 125mm dia suitable for Nahani trap or in any place complete all as specified and as directed.
S & F in repairs plastic water closet seat and cover of white colour, closed pattern with flat bottom suitable for pedestral / Semi pedestral pattern water closets and mild steel chromium plated or aluminized hinging device all as specified and directed.
S & F in repairs of 15mm bore size PVC PTMT bib tap complete all as specified and as directed.
M & L for glazed ceramic tiles in vertical surface 300x450x8-10 mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade incl 10mm thick screed bed in CM 1:4 including dismantling of existing floor/wall tiles , stone slab of any description complete all as specified and as directed.
M & L for Non-Skid coloured ceramic tiles 7-8mm thick (square/rectangular) area of each tiles exceeding 0.11 sqm but n.exc 0.18 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade incl 15mm thick screed bed in CM 1:6 including dismantling of existing floor/wall tiles , stone slab of any description complete all as specified and as directed.
M & L for Non-Skid coloured ceramic tiles 7-8mm thick (square/rectangular) area of each tiles exceeding 0.06sqm but not exceeding 0.11 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade incl 15mm thick screed bed in CM 1:6 including dismantling of existing floor/wall tiles , stone slab of any description complete all as specified and as directed.
S & F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws including dismantling of plain or corrugated sheeting any gauge thickness including Nainital or similar pattern as in roof covering complete all as specified and as directed.
S & F for Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws including dismantling of plain or corrugated sheeting any gauge thickness including Nainital or similar pattern as in roof covering complete all as specified and as directed.
M & L 20 mm thick granite (of any type) work( table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match the shade of granite slab , notching and moulding including demolition of existing granite complete all as specified and as directed .
M & L for machine cut kota stone slab 18-20 mm thick as in flooring laid over and incl cement screed base 15mm thick in CM 1:6 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing including dismantling of existing floor wall , stone slab of any description complete all as specified and as directed.
M & L for brick work in CM 1:6 using Sub class "B" bricks straight or curved on plan exc. 6mmean radius including demolition of existing brick/block masonry built in cement mortar complete all as directed.
Demolition of cement concrete (unreinforced) in ground floor and paving near 15 cm thick (below or above ground level).
M&L 75mm thick cement concrete 1:3:6 type B1 using 20mm graded stone aggregate as in plinth protection & finished the surface even & smooth w/o using extra cement.
M&L Mild steel frame work as in door chowkhats with angle iron welded together ends of angle shouldered and fixed to opening and welding 3 Nos mild steel butt hinges 100 mm size, 01 nos 50 mm size and 6 nos hold fasts made out of FI 25x3 mm 30 cm long for fixing of chowkhats( Butt hinges and hold fast paid seperatly) all as spd.
Hiring of services for 01 x Carpenter, 01 x Plumber, 02 x Sweepers, with 02 x Helper in 01 shifts days along with complete trade T & P and report to Parade Ground service centre for attending day to day complsints during parade camp complete all as directed. (Payment will be made on the basis of actual attendance) Note :- repair to aluminum and PVC door, windows and welding work shall be included in this Carpenter work.
S & F in repairs vitreous china bowl urinal flat back size 465x355x265mm white with grating and union for discharge pipe including connection for flushing pipe and outgoing pipes.
M & L for grinding and polishing existing old kota stone floors and walls all as specified in SSR incl cleaning splashes from floors and walls complete all as directed.
S & F 5.5mm thick sheet glass, ordinary quality and glazing with rubber beading to aluminum frame not exc 0.5 Sqm in each pane all as specified and directed including hacking out old broken glass (any thickness, size, quality or description) complete.
M & L for preparation of plastered or unplastered old decorated surfaces of walls including brooming down or scraping down with steel wire brushes of smoke spots , moulds ,moss efflocerent salts and treading oil and greasy spots, filling the cracks, holes with POP/Putty and applying One coat of Oil bound distemper complete all as specified and directed.
M & L for preparation of plastered or unplastered old decorated surfaces of walls including brooming down or scraping down with steel wire brushes of smoke spots , moulds ,moss efflocerent salts and treading oil and greasy spots, filling the cracks, holes with POP/Putty and applying One coat of Cement Based Paint complete all as specified and directed.
M & L for One Coat of Synthetic Enamal Paint on wooden surfaces including prepration of Old surface of any description, over 10cm in width or girth complete all as specified and as directed.
M & L for One Coat of Synthetic Enamal Paint on steel surfaces including prepration of Old surface of any description, over 10cm in width or girth complete all as specified and as directed.
M & L for preparation of plastered or unplastered old decorated surfaces of walls including brooming down or scraping down with steel wire brushes of smoke spots , moulds ,moss efflocerent salts and treading oil and greasy spots, filling the cracks, holes with POP/Putty and applying One coat of weather shield exterior acrylic emulsion paint (APEX Paint or equivalent as per approved make list) of any tint all as per manufacturers instructions to achive desired finish at any height complete all as directed.
M & L for preparing newly plastered surfaces of wall incl preparation of surfaces and applying two coats of cement base paint over a coat of primer on wall surfaces complete as specified and directed.
M & L for wall care putty not less than 1-2mm thick in two or more coats applying on walls complete all as specified.
Preparing existing black top surfaces by using mechanical air blower of adequate capacity as directed to remove all loose dirt e.t.c complete all as specified and as directed.
M & L for applying evenly one coat of water based bituminous road marking thinable paint of black colour on prepared black top surfaces. Rate of application shall not be less than 1ltr/20sqm complete all as directed by engr-in-Charge and GE.
M & L for preparation of black top surfaces of road by cleaning with air blower and applying 1.5mm thick road marking strips, dahses, arrows letters etc upto 10cm wide or more (retro-reflective) of white or golden yellow shade/colour using hot thermoplastic paint applicator machine fitted with profile shoe, glass beads dispenser, propane tank heater and driven by experienced operator on road surface including cleaning all loose dirt, seals, oil greases and foreign materials etc complete all as directed by Engr-in-Charge and as per applicators specifications-APCO or equivalent as approved by GE.
S & F in repairs Aluminium alloy powder coated door including frame comprising of section (Door frame single groove 101.6mm x44.45mm x 2.1mm thick, Shutter top 47.62mm x 44.45mm x 1.95mm thick, shutter bottom 114.30mm x 44.45mm x 2.15mm thick, shutter vertical 85mm x 44.45mm x 1.80mm thick, shutter middle 83.5mm x 44.45mm x 2.40mm thick & glazing clip weighing not less than 0.097 kg/Mtr) as approved by GE & as per IS specifications including provision of 5.5mm thick tinted glass/12mm thick prelaminated particle board as required including handles, tower bolt, floor spring, locking arrangement, rubber gasket and stopper complete all as specified & directed.
S & F E-board 'Everest' make 600x600x4mm thick white prelaminated sett embosed reinforced designer ceiling board tiles of approved texture at all height laid on Hot dipped Galvanised iron imposed grid with 24mm wide T-section exposed flanges which shall be powder coated white. The frame work shall comprise of main runner made from 0.33mm thick GS sheet and of size 24x32x3000mm and spaced at 1200mm centers securely fixed to the structural soffits by approved hangers at 1200mm maximum centers. Hangers of GI wire 4mm dia to be fixed by approved rawl plug, level and justers and screws etc. The last hanger at the end of each main runner shall not be greater than 450mm from adjacent wall. Flush fitting of 1200mm long cross tee (with double stitching) to be interlocked between main runners at 600mm center to form 1200x600mm modules cross tee longer than 600mm to be supported independently. 600x600mm modules to be formed by fitting 600mm long cross Tee centrally between the 1200mm cross tee. Tee, Perimeter wall angle shall be of 0.45mm thick GS sheet of size 19x19mm and 300mm long of white colour all as per manufacture instruction including taking down the existing false ceiling of any type with frame work complete all as specified and directed.
M & L for laying 40mm thick bitumen mastic wearing coarse with industrial bitumen conforming to IS 702 prepared by using mastic cooker and laid to required level and slope and cleaning the surface , incl dismantling and removal of debris etc all as directed. (Density of mastic asphaltic as 2.29gm/cc and percentage of bitumen 10.20% as per MORTH specification.
M & L for Machine pressed precast cement conctete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement and pigment including 50mm thick sand cushion including dismantling of existing Interlocking tiles of any type/size and in any position complete all as specified.
M & L for Chequered cement concrete tiles 30cm x 30cm x 25mm thick with grey cement and no pigment, set, jointed and pointed in neat cement slurry,laid over and including 15mm thick screed bed in CM 1:6 as in floors including dismantling of existing chequred tiles of any type/size and in any position complete all as specified.
S & F for Precast SFRC man hole covers and frame 75 mm thick medium duty factory made test load 10 tons (MD-10) conforming to IS-12592, complete all as specified and as directed.
M & L for acid wash to any type of surface (Grit plaster, floor/wall tiles or any type of surfaces) on floor/wall as directed by Engr-in-Charge and as required at site complete all as specified and as directed.
Taking down carefully copper/ aluminum pt. Wiring light/ fan/ bell/ socket/ power complete and making good the disturbed surfaces of Walls/ floors/ ceiling complete all as specified & directed by Engr in charge.
Material and labour of point wiring with PVC insulated unsheathed cable 1.5 sqmm with stranded copper conductor, in and including surface PVC conduit 20mm dia with fittings, including all tees, bell mouth tube ends and fixing accessories such as couplers, saddles, pipe hooks etc with provision of new CI/MS terminal boxes with decorative laminated sheet top cover 3 mm thick including PVC insulated copper earth conductor 1.50 sqmm connected to common earth and earth dolly complete.
(a) One light point or one fan point or bell point controlled by one switch SP, one way, 230 volts.
(b) One 3 pin socket outlet 5/6 Amps on same board.
(c ) One socket outlet 5/6 Amps on independent board.
All as per srl item No 74 above but for power socket 15/16 Amp with cable 4 Sqmm for phase & neutral for earth 2.5 sqmm
M & L any type of wiring with FRLS PVC insulated heat retardent stranded copper conductor cable through existing steel /PVC concealed/surface conduit copper conductor cables 1.5 sqmm and one run of 1.5 sqmm cable as earth continuity wire ,Provn of New 3 MM thick hylam sheet with screw,cup washers etc for fixing switchh,socket,etc as directed by Engineer-in-Charge. phase neutral and earth wire shall be provided in strandard colour code R.Y.B for phase , black for neutral , green for earth wire :-
(a) One light point or one fan point or bell point controlled by one switch SP, one way, 230 volts.
(b) One 3 pin socket outlet 5/6 Amps on same board.
(c ) One socket outlet 5/6 Amps on independent board.
All as per srl item No 79 above but for power socket 15/16 Amp with cable 4 Sqmm for phase & neutral for earth 2.5 sqmm
S & F of switch piano flush type 5 Amps SP one way all as specified.
S & F of switch piano type 15 Amps SP one way all as specified.
S & F of socket outlet 2-in-1,5 Amps flush type 3 pin 5 Amps multi purpose all as specified.
S & F of socket outlet 2 in 1 (multipurpose) 3 pin 5 and 15 Amps flush mounted type all as specified.
S&F in replacement ceiling rose surface bakelite65 x50mm with two to threeterminals.
S & F in replacement of lamp holder bakelite insulated body with back plate suitable for batten fitting all as specified.
M & L in replacment of fan regulator stepped electronic flush type suitable for 1200/1400 mm sweep fan as per existing pattern.
All as per srl item No 90 above but electronic dimmers 450 W,250 V .
M & L in replacement of Buzzer, ding dong AC, 230 volts single pole all as specified.
M & L in replacement of bell multi music type 230 volts single phase all as specified and directed.
M & L in replacement of distribution board triple pole and neutral 4 way with metal door and IP 43 Protections all as specified. complete all as specified
All as per Item No 94 but of 8 way TPN DB.
M & L for MCCB, 4 Pole, 125 Amps, 16 KA, AC ,415V .
M & L for MCCB, 4 Pole, 250 Amps, 36 KA, AC ,415V
M&L MCCB, 4 pole, 100 Amps, 36 KA, 415 Volts
M & L MCB SP 10 to 32 Amps,230V, 10 KA C curve all as specified.
M & L MCB SPN 40 Amps, 240 volts C- Series 10 KA as specified .
M & L MCB SPN 63 Amps 240 volts C- Series 16 KA as specified.
M & L in replacement of single pole and neutral metal clad sheet steel enclosures with 2 pin and earth plug and socket complete with MCB SP 32 Amps.
All as per Ser item No 102 above but with 10 Amps.
S & F in replacment of MCB DB single phase & Neutral 2 Way , double door IP-43 flush mounting.
S & F in replacment of MCB DB single phase & Neutral 4 Way , Double door IP-43 flush mounting
S & Fin replacment of MCB DB single phase & Neutral 8 Way , Double door IP-43 flush mounting
S & F in replacement heavy duty main switch fused with HBC fuses triple pole and neutral surface mounting tube housed in sheet steel enclosure with side handle operation and front access opening doors interlocking type of capacity 100 Amps.
S & F in replacement heavy duty main switch fused with HBC fuses triple pole and neutral surface mounting tube housed in sheet steel enclosure with side handle operation and front access opening doors interlocking type of capacity 63 Amps.
S&F changer over switch off load AC, 415 volts, TPN 100 Amp ,side handle operated,heavy duty in sheet metal enclouser complete.(Make : Havell's/HPL/Std).
S&F changer over switch off load AC, 415 volts, TPN 63 Amp ,side handle operated,heavy duty in sheet metal enclouser complete.
Supply and Fixing in replacement heavy duty main switch fused with HBC fuses single pole and neutral surface mounting tube housed in sheet steel enclosure with side handle operation and front access opening doors interlocking type of capacity 32 Amps.
Supply & Fixing of Mirror light fitting, 10/12 watt 230 V, with all aceessories internally pre-wired and incld connecting up with twin core twisted flexible copper conductor cable with suitable size I all as specified.
S&F in replacement LED tube light fitting 4 feet suitable for 20/22 W LED T/L fitting complete for recess mounting and making all electric connection all as specified and directed .
S&F in replacement LED street light fitting 40 W LED 50 Hz,CRI less then 75,Lumens output 4320,IP 65 ingress Protection and Power factor > 0.9 complete with all accessories Make SYSKA model/code SSK-ST-40W(S) or Equivelent make and model as per approved list including brackets complete all as specified.
S&F of LED bulbs 9W, B 22/E14/E27 90-300V AC-50 Hz complete all as directed.
M & L in replacement of Bulk head light fitting , 230 V bulk head luminaries with lamp holders, etc complete with all aceessories and inlcd connecting up with twin core twisted flexible copper conductor cable with suitable size I all as specified. Make- Havells/Philips /Bajaj all as approved by engineer in charge
M & L in replacement of FRLS PVC insulated single core with stranded copper cable of size 6 Sqmm in 2 run and 4.0 Sqmm one run for earth and drawing in existing conduit all as specified.
All as per srl item No 117 here - in -before but copper cable single core of size 4 Sqmm in 2 run with earth wire 2.5 Sqmm single run for earth all as specified.
M & L for earthing complete with GI earth plate electrode 600 x 600 x 6mm thick burried directly in ground not less than 2.25 mtrs below ground level, with top edge of the plate not less than 1.5 mtrs deep below normal ground level, connected to galvanised earth wire 4mm by means of bolts, nuts check nuts to earth test point including necessary PCC 1:2:4 type B-1 pit, cover frame, GI pipe 15mm dia light grade with funnel and locking arrangement all as specified and directed by Engr-in-Charge, testing on completion.
Supply & Laid in trenches in replacement of LT UG XLPE cable 6 sqmm 2 core 1100 volts grade armoured with aluminium conductor ISI marked all as specified and directed by the Engr-in-charge. (GI pipe for cable protaction, sand cushioing and excavation are out of the scope of these items and shall be measured and paid respective items)
All as per item No-120 above but 16 sqmm,2 Core.
S & F of GI tubing light grade 40mm bore 6 mtr in length complete all as specified and directed by the Engr-in-charge.
Excavation in trenches in loose/soft soil not exceeding 1.5 mtr wide and not exceeding 1.5 mtr deep and getting out including forming bottom surface for laying LT cable as specified and directed at site by Engineer-in-Charge.
Returning filling in soil including spreading, levelling, watering and well rammingin layers not exceeding 25 cm complete as specified and directed by the Engr-in-charge.
Removing exccavated soil not exceeding 50 mtr and depositing wheredirected at a level not exceeding 1.5 mtr above the starting point, complete.
M&L for sand cushioning to under ground cable provided with layers of snad(8 cms deep before laying the cable and 15 cms deep after laying) complete allas specified and directed at site by Engineer-in-Charge.
Supply and laying burnt bricks class - B for profection of cable complete all asspecified and directed at site.
S&F in replacement of condenser 2.5 mfd including provision of fixing clamp with screws and necessary items such as sleaves etc if required.
S&F in replacement of condenser 3.15 mfd including provision of fixing clamp with screws and necessary items such as sleaves etc if required.
M& L in replacement of service wire PVC sheathed of size 6 sqmm aluminum conductor complete all as specified and directed.
M& L in replacement of service wire PVC sheathed of size 10 sqmm aluminum conductor complete all as specified and directed.
Material and labour rewinding of Exaust fan 380mm sweep any modle and make with copper conductor of suitable gauge including provn of cut paper/varnishing including replacement of bearing, bush,shaft and capacitor all as required complete all as directed.
M&L in replacement of cable PVC flexible (copper) with core of size 23/0.0076. complete all as specified & directed by Engr-in-charge.
M&L in replacement of cable PVC flexible (copper) with core of size 40/0.0076. complete all as specified & directed by Engr-in-charge.
Supply & fixing in replacement metal Exhaust fan blade set up to 450 mm sweep white colour As per sample complete all as specified & directed by Engr-in-charge.
Supply & fixing in replacement fan blade set 1200 mm sweep white colour As per sample complete all as specified & directed by Engr-in-charge.
Supply & fixing in replacement fan blade set 1400 mm sweep white colour As per sample complete all as specified & directed by Engr-in-charge.
Taking down geyser 25/35/50 ltrs capacity of any make, opening up complete for inspection descalling by chemical treatment of internal tank , taking out themrostate pipe, base plate assembly carrying out minor repairs including replacement of gaskets nut/bolts etc testing and refixing in position including making electrical and water connection all as directed by Engineer-in-Charge.
S & F replacement heating element for geyser 1.5KW complete all as directed Make : Theeta/Daspass.
S & F replacement heating element for geyser 2KW complete all as directed Make : Theeta/Daspass.
S & F replacement thermostat for geyser adjustable steam type AC 240 Volts range 25 degrees to 75 degrees celcius complete all as directed.
Soldering and brazing inner copper tank 25/35 ltrs with brass solder and refixing complete (taking down and fixing shall be paid under item No 138 here-in-before.
M & L in replacement of PVC connection pipe 24" long with two brass adopters and connecting up complete all as directed by Engr-in-Charge.
M &L in replacement of non return valve 15/20 mm dia (ISI Marked) and connecting up complete including GI Socket, elbow, bend etc all as directed.
M & L in replacement of safety valve/high pressure release valve (ISI Marked) with dead weight etc complete suitable for any makes/capacity/type of geysers installed at site all as directed.
S & F in replacement top cover geysers (confirming to ISI) suitable for any makes/capacity/type of geysers installed at site duly painted (spray) in two coats with enamelled (Deco) paint of colour & shade all as directed.
S & F in replacement bottom cover for geysers (confirming to ISI) suitable for any makes/capacity/type of geysers installed at site duly painted (spray) in two coats with enamelled (Deco) paint of colour & shade as directed complete with inspection plate in two pieces.
M & L in replacement plug top, 3 pin 10/20 Amp earth metal clad (ISI marked as directed.
M & L in replacement socket 3 pin 10/20 Amp earth metal clad (ISI marked as directed.
M & L in replacement sheet Bakelite (Hylam) 3 mm thick including cutting of sheet for fixing switch/socket required including fixing of old switch/socket and making connection etc for the following:-
(a) Sheet size 11" x 13"
(b) Sheet size 8" x 10"
(c ) Sheet size 8" x 5"
M&L in replacement pressed steel terminal boxes sunked for mounting switches/ socket, fan regulator, etc. size of box retangular 75 x 75 x 60 mm.
M&L in replacement pressed steel terminal boxes sunked for mounting switches/ socket, fan regulator, etc. size of box retangular 175 x 100 x 60 mm.
M&L in replacement pressed steel terminal boxes sunked for mounting switches/ socket, fan regulator, etc. size of box retangular 250 x 300 x 60 mm.
Supply only of ISI marked 1500w oscillating quartz room heater heat piller with parabolic reflector complete all as specified and directed by Engr-in-charge. Make : Gopi/Belco/Bexco/Warmex
Supply only Hygiene 30w slim insect killer insect catcher bug zapper repellent fly swatter UV tube insect killer machine complete all as specified and directed by Engr-in-charge. Make: Hygienic/IBELL/H Hytech
S&F of LED Flood light 150Watt white focus , super strong metal body & handle, high lumens energy efficient IP 67 led light complete all as specified and directed by Engr-in-Charge.
Hire charges for providing, fixing in position of 1100 volt grade heavy duty cable PVC insulated aluminium conductor 16sqmm stranded served with sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 meter apart including 4mm suspension wire two single core cables flat or circular complete laid on ground/fixed on steel pipes/wooden bullies/poles along with continuous copper conductor earth wire of suitable size PVC insulated/protection pipe where required and all as directed by Engr-in-charge. (400 RM x 90 days)
All as per item No 160 above but size of cable 6 Sqmm
All as per item No 160 above but size of cable 4 Sqmm
All as per item No 160 above but size of cable 2.5 Sqmm
Hire charges for providing and fixing in position light point, bell point/light socket point wiring with PVC insulated aluminum conductor cable 2.5 Sqmm including same size of copper conductor cable as earth wire partly in conduit laid in tents/shamianas wherever required including switches, sockets, lamps holders and bells complete fixed on proper boards all as directed at site (150 points x 90 days) Note:- All cables and accessories shall be fire retardant low smoke.
Hire charges for providing and fixing in position power point, wiring with PVC insulated aluminum conductor cable 4 Sqmm including 2.5 sqmm size of copper conductor cable as earth wire partly in conduit laid in tents/shamianas etc wherever required including complete fixed on proper boards all as directed at site 20 points x 90 days) Note:- All cables and accessories shall be fire retardant low smoke.
All as item No 166 above but for tube light points in shamianas/ tents on ballies wherever required including any type of fluoresents tube light fittings with tube rod as required complete (20 Nos x90 days.
Hire charges for providing, fixing in position including testing street light fitting/ tube light fitting watt including all accessories like choke, capacitor, starter , connector, driver complete with suitable size of cable for exisiting poles/ballies including suitabe pipes brackets and clamps where require all as directed by Engr-in-charge (20 Nos x 90 days)
Hire charges for and including providing fixing and connecting properly the follwing safety devices complete all as dictected by Engr-in-charge, (20 NosX90 days. (a) MCB DBs 8/4 way SPN -20Nos. (b) MCB SPN 20 Amps-20 Nos. (c) MCB SP6 to 32 Amps -80 Nos.
Hire charges for providing, fixing in position including testing Metal halide/flood light fitting including all accessories like lamp holder with lamp 1000 watt connected complete with suitable size of cable for exisiting poles/ballies including suitabe pipes brackets and clamps where require all as directed by Engr-in-charge (30 Nos x 3 days)
Hire charges for providing, fixing in position of 1100 volt grade heavy duty cable PVC insulated aluminium conductor 16 sqmm stranded served with sheathing of PVC tape and overall PVC sheathed two single core cables flat or circular complete laid on ground/fixed on steel pipes/wooden ballies/poles along with continuous copper conductor earth wire of suitable size PVC insulated/protection pipe where required and all as directed by Engr-in-charge. (900 RM x 3 days)
All as per item No 171 above but size of cable 6 Sqmm (400 RM x 3 days)
Hire charges for providing, fixing in position extention board comprising of the following items complete including connected with suitable size of cable of approximate length 3 mtrs where require all as directed by Engr-in-charge (30 Nos x 3 days) :- a) Socket outlet 5 amps with switches - 2 Nos b) Socket outlet 16 amps with switches - 1 Nos
Maintenance and safe custody of temporary electrification, detecting faults if any and making electric supply functional round the clock by providing the following for APG camp: a) Electrician - 03 Nos (one electricians each in three shifts b) Helper - 03 Nos (one helper each in three shifts
tarun construction co
ASSOCIATED CONSTRUCTION CO.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .