Tender Value
₹1.2 Cr
EMD Value
₹2.0 L
Closing Date
2 Jun 2022, 6:00 pmClosed
CWE JABALPUR
HQ CWE JABALPUR OPPOSITE SUPPLY DEPOT MARG SADAR JABALPUR 482001
SPECIAL REPAIR TO EXTERNAL ELECTRIC SUPPLY BY CONVERSION OF LT OH LINE INTO LT UG CABLE AT LEKHA NAGAR COLONY UNDER GE EAST JABALPUR
2022_MES_520635_1
82612/E8
Open Tender
Miscellaneous Works
Item Rate
270 days
JABALPUR
AS PER NIT
8 documents required · 8 mandatory
₹1,000
Yes
GE EAST JABALPUR
₹2.0 L
Yes
28 Jul 2022
28 Apr 2022
4 Jun 2022
28 Apr 2022
2 Jun 2022
19 May 2022
28 Apr 2022 - 18 May 2022
Amount
Supply and laying or fixing or passing in trenches/ on pole/ through pipes, 1100 V grade XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor of following cross sectional areas and testing on completion complete all as specified and as directed :-
4 core X 10 sqmm
4 core X 16 sqmm
4 core X 25 sqmm
3.5 core X 50 sqmm
3.5 core X 120 sqmm
3.5 core X 150 sqmm
3.5 core X 185 sqmm
3.5 core X 240 sqmm
Excavation in trenches, not exceeding 1.5m wide and exceeding 1.5m but not exceeding 3 m in depth for poles, laying of pipe, cable, erection of post and stays etc or n. exc.10 Sqm on plan and n. exc. 1.5m in depth etc and getting out in soft/loose soil complete all as specified and directed.
Excavation in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for poles, laying of pipe, cable, erection of post and stays etc or n. exc.10 Sqm on plan and n. exc. 1.5m in depth etc and getting out in soft/loose soil complete all as specified and directed.
Returning, filling in excavated , including spreading, levelling, watering and well ramming in layers not exceeding 25cm of soft/loose soil complete all as specified and directed.
Removing excavated soil not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point including spreading complete all as specified and directed.
Supply and spreading clean and dry fine sand free from sharp materials (unwashed) laying in trenches around the cable for cushioning in trenches, laid to a uniform thickness of 23cm (15cm under the cable & 8cm over the cable) and gently punned down to 18cm thickness complete all as specified and as directed. (Note :- Punned thickness shall be measured.)
Supply and laying un-reinforced precast concrete cable covers(ISI marked), Class LV type I, Flat, size 250 mm x 150 mm x 40 mm, complete all as specified and as directed.
Demolition of cement concrete of any description (unreinforced) in ground floors and paving not exceeding 15 cm in thickness (below or above ground level) including removal of debris to out side MD land complete all as specified & directed.
M&L for PCC (1:4:8) Type D-2 using 40 mm graded stone aggregate as in foundation, filling, mass concrete and sub base of floors, path/ paving etc complete all as specified & directed.
M&L for PCC 1:3:6 Type C-1 using 20mm graded stone aggregate as in copings of pole etc and the like including weathering slightly rounded/ chamfered angles with & including necessary use and waste of form work for fair faces of concrete, complete all as specified and directed.
Taking out / down old unserviceable underground cable from trenches, wall, floor etc. and removing from site, size upto 25 sqmm complete all as specified and directed. Note :- Excavation and earhwork for taking out existing old unserviceable cable shall be deemed to be included in the unit rate quoted by contractor
Taking out / down old unserviceable underground cable from trenches, wall, floor etc. and removing from site, size 35 to 120 sqmm complete all as specified and directed. Note :- Excavation and earhwork for taking out existing old unserviceable cable shall be deemed to be included in the unit rate quoted by contractor
Taking out / down unserviceable underground cable from trenches, wall, floor etc. and removing from site, size 150 to 400 sqmm complete all as specified and directed. Note :- Excavation and earhwork for taking out existing old unserviceable cable shall be deemed to be included in the unit rate quoted by contractor
Material and labour for boring hole under the road /path/ pavement/ hard standing ( width not more than 10 metre) with the help of Trenchless Technology using ultra sound technique and necessary machine with and including HDPE pipe of 110 mm bore suitable for 0.4 Mpa working pressure, HDPE pipe laid not less than 1 metre below avg ground level complete all as specified and directed. Note :- Cost of HDPE pipe as specified above shall be deemed to be included in the unit rate quoted by the contractor.
S&F cable route indicator/marker made up of PCC block in (1:3:6) Type C-1 using 20 mm graded crushed stone aggregate, of size 300 mm x 300 mm x 600 mm thick with " Danger/LT 433 VOLTS CABLE " embossed on cable route indicator /Marker including painting as per colour approved by GE and buried in ground 45 cm including necessary excavation , earthwork and formwork complete all as specified and directed.
Supplying and fixing/ laying of GI pipe light grade in trenches/ under roads/ along pole/ wall including all necessary fittings & clamps made out of 25x3mm flat iron as required for cable protection etc complete all as specified and directed for following dia of pipe :-
(a) 100 mm dia
(b) 80 mm dia
(c) 50 mm dia
(d) 40 mm dia
(iii) INCOMING Air circuit breaker 1250 Amps, 4 Pole, breaking capacity , 50 KA , ICU=ICS=ICW for 1 Sec of total sensitivity, fixed type, EF version inbuilt 6 NO+6NC aux contact, door ceiling frame, manually and electrically operated complete with 240 V shunt trip coil, closing coil and motor for electrical charging, C power S-1 Range, conforming to IS/IEC 6094-2, microprocesser base with testing through test button with cover through MODBUS potcall complete all as specified. Make:- Legrand Cat.No.669533 or equivalent of other Make- ABB or Schneider as approved by GE. (iv) OUTGOING (a) MCCB 4 Pole, 320 Amps, Thermal Magnetic Release, Ics = 100% of Icu, 415 Volts with rupturing capacity 36 KA -02 Nos. Make:- Legrand Cat.No.4220 62 or equivalent of other Make ABB or Schneider as approved by GE. (b) MCCB 4 Pole, 250 Amps, Thermal Magnetic Release, Ics = 100% of Icu, 415 Volts with rupturing capacity 36 KA -04 No. Make:- Legrand Cat.No.4203 49 or equivalent of other Make ABB or Schneider as approved by GE. (c) MCCB 4 Pole, 200 Amps, Thermal Magnetic Release, Ics = 100% of Icu, 415 Volts with rupturing capacity 36 KA -04 Nos. (For further extension) Make:- Legrand Cat.No.4202 48 or equivalent of other Make ABB or Schneider as approved by GE. (d) MCCB 4 Pole, 25 Amps, Thermal Magnetic Release, Ics = 100% of Icu, 415 Volts with rupturing capacity 36 KA -01 Nos. (For further extension) Make:- Legrand Cat.No.4200 91 or equivalent of other Make ABB or Schneider as approved by GE. (e) MCB 2 Pole, 32 Amps - 01 No. Make:- Legrand Cat.No.4086 17 or equivalent of other Make ABB or Schneider as approved by GE. (v) Digital time switch including three phase power contactor 40 Amps. Make :- Legrand Cat No. 412641 or equivalent as approved by GE & Power contactor Legrand Cat No. 412549 or equivalent as approved by GE -1 No. (vi) Indicator lamp (LED type) & bakelite fuse showing R,Y,B phase - 1 No. (vii) Digital frequency meter 40-60 Hz - 01 Set. (e) Power contactor, 3 Pole rating not less than 70A with 230 Coil - 01 No Make :- Legrand cat part No. 416143, Havells, L&T or equivalent as approved by GE.
(iii) INCOMING Thermal magnetic and microprocesser release MCCB 200 Amps, 4 Pole breaking capacity , 36 KA , with front operated locking device - 1No. Make:- Legrand Cat.No.4202 48 or equivalent of other Make ABB or Schneider as approved by GE. (iv) OUTGOING (a) MCCB 4 Pole, 63 Amps, Thermal Magnetic Release, Ics = 100% of Icu, 415 Volts with rupturing capacity 16 KA -05 Nos. Make:- Legrand Cat.No.4200 13 or equivalent of other Make ABB or Schneider as approved by GE. (b) MCB 2 Pole, 32 Amps - 01 No. Make:- Legrand Cat.No.4086 17 or equivalent of other Make ABB or Schneider as approved by GE. (v) Digital time switch including three phase power contactor 40 Amps. Make :- Legrand Cat No. 412641 or equivalent as approved by GE & Power contactor Legrand Cat No. 412549 or equivalent as approved by GE -1 No. (vi) Indicator lamp (LED type) & bakelite fuse showing R,Y,B phase - 1 No. (vii) Digital frequency meter 40-60 Hz - 01 Set.
(iii) INCOMING Thermal magnetic and microprocesser release MCCB 250 Amps, 4 Pole breaking capacity , 50 KA , with front operated locking device - 1No. Make:- Legrand Cat.No.4203 49 or equivalent of other Make- Legrand or ABB or Schneider as approved by GE. (iv) OUTGOING (a) MCCB 4 Pole, 63 Amps, Thermal Magnetic Release, Ics = 100% of Icu, 415 Volts with rupturing capacity 16 KA -05 Nos. Make:- Legrand Cat.No.4200 13 or equivalent of other Make ABB or Schneider as approved by GE. (b) MCCB 4 Pole, 25 Amps, Thermal Magnetic Release, Ics = 100% of Icu, 415 Volts with rupturing capacity 16 KA -02 Nos. Make:- Legrand Cat.No.4200 11 or equivalent of other Make ABB or Schneider as approved by GE. (c) MCB 2 Pole, 32 Amps - 01 No. Make:- Legrand Cat.No.4086 17 or equivalent of other Make ABB or Schneider as approved by GE. (V) Digital time switch including three phase power contactor 40 Amps. Make :- Legrand Cat No. 412641 & Power contactor Legrand Cat No. 412549 -1 No. (vi) Indicator lamp (LED type) & bakelite fuse showing R,Y,B phase - 1 No. (vii) Digital frequency meter 40-60 Hz - 01 Set.
(iii) INCOMING Thermal magnetic and microprocesser release MCCB 320 Amps, 4 Pole breaking capacity , 50 KA , with front operated locking device - 1No. Make:- Legrand Cat.No.4220 72 or equivalent of other Make ABB or Schneider as approved by GE. (iv) OUTGOING (a) MCCB 4 Pole, 63 Amps, Thermal Magnetic Release, Ics = 100% of Icu, 415 Volts with rupturing capacity 16 KA -07 Nos. Make:- Legrand Cat.No.4200 13 or equivalent of other Make ABB or Schneider as approved by GE. (b) MCCB 4 Pole, 25 Amps, Thermal Magnetic Release, Ics = 100% of Icu, 415 Volts with rupturing capacity 16 KA -01 No. Make:- Legrand Cat.No.4200 11 or equivalent of other Make ABB or Schneider as approved by GE. (c) MCB 2 Pole, 32 Amps - 01 No. Make:- Legrand Cat.No.4086 17 or equivalent of other Make ABB or Schneider as approved by GE. (v) Digital time switch including three phase power contactor 40 Amps. Make :- Legrand Cat No. 412641 or equivalent as approved by GE & Power contactor Legrand Cat No. 412549 or equivalent as approved by GE -1 No. (vi) Indicator lamp (LED type) & bakelite fuse showing R,Y,B phase - 1 No. (vii) Digital frequency meter 40-60 Hz - 01 Set.
(iii) INCOMING Thermal magnetic and microprocesser release MCCB 250 Amps, 4 Pole, breaking capacity , 50 KA , with front operated locking device - 1No. Make:- Legrand Cat.No.4203 79 or equivalent of other Make ABB or Schneider as approved by GE. (iv) OUTGOING (a) MCCB 4 Pole, 63 Amps, Thermal Magnetic Release, Ics = 100% of Icu, 415 Volts with rupturing capacity 16 KA -06 Nos. Make:- Legrand Cat.No.4200 13 or equivalent of other Make ABB or Schneider as approved by GE. (b) MCB 2 Pole, 32 Amps - 01 No. Make:- Legrand Cat.No.4086 17 or equivalent of other Make ABB or Schneider as approved by GE. (v) Digital time switch including three phase power contactor 40 Amps. Make :- Legrand Cat No. 412641 or equivalent as approved by GE & Power contactor Legrand Cat No. 412549 or equivalent as approved by GE -1 No. (vi) Indicator lamp (LED type) & bakelite fuse showing R,Y,B phase - 1 No. (vii) Digital frequency meter 40-60 Hz - 01 Set.
(iii) INCOMING Thermal magnetic and microprocesser release MCCB 630 Amps, 4 Pole, breaking capacity , 50 KA , with front operated locking device - 1No. Make:- Legrand Cat.No.4220 75 or equivalent of other Make ABB or Schneider as approved by GE. (iv) OUTGOING (a) MCCB 4 Pole, 250 Amps, Thermal Magnetic Release, Ics = 100% of Icu, 415 Volts with rupturing capacity 36 KA -02 Nos. Make:- Legrand Cat.No.4202 49 or equivalent of other Make ABB or Schneider as approved by GE. (b) MCCB 4 Pole, 200 Amps, Thermal Magnetic Release, Ics = 100% of Icu, 415 Volts with rupturing capacity 36 KA -02 Nos. Make:- Legrand Cat.No.4202 48 or equivalent of other Make ABB or Schneider as approved by GE. (c) MCCB 4 Pole, 63 Amps, Thermal Magnetic Release, Ics = 100% of Icu, 415 Volts with rupturing capacity 25 KA -01 No. Make:- Legrand Cat.No.4200 53 or equivalent of other Make ABB or Schneider as approved by GE. (d) MCCB 4 Pole, 25 Amps, Thermal Magnetic Release, Ics = 100% of Icu, 415 Volts with rupturing capacity 16 KA -01 No. Make:- Legrand Cat.No.4200 11 or equivalent of other Make ABB or Schneider as approved by GE. (b) MCB 2 Pole, 32 Amps - 01 No. Make:- Legrand Cat.No.4086 17 or equivalent of other Make ABB or Schneider as approved by GE. (v) Digital time switch including three phase power contactor 40 Amps. Make :- Legrand Cat No. 412641 or equivalent as approved by GE& Power contactor Legrand Cat No. 412549 or equivalent as approved by GE -1 No. (vi) Indicator lamp (LED type) & bakelite fuse showing R,Y,B phase - 1 No. (vii) Digital frequency meter 40-60 Hz - 01 Set.
(iii) INCOMING Thermal magnetic and microprocesser release MCCB 200 Amps, 4 Pole, breaking capacity , 36 KA , with front operated locking device - 1No. Make:- Legrand Cat.No.4202 48 or equivalent of other Make ABB or Schneider as approved by GE. (iv) OUTGOING (a) MCCB 4 Pole, 125 Amps, Thermal Magnetic Release, Ics = 100% of Icu, 415 Volts with rupturing capacity 16 KA -01 Nos. Make:- Legrand Cat.No.4200 16 or equivalent of other Make ABB or Schneider as approved by GE. (b) MCCB 4 Pole, 63 Amps, Thermal Magnetic Release, Ics = 100% of Icu, 415 Volts with rupturing capacity 16 KA -03 Nos. Make:- Legrand Cat.No.4200 13 or equivalent of other Make ABB or Schneider as approved by GE. (c) MCB 2 Pole, 32 Amps - 01 No. Make:- Legrand Cat.No.4086 17 or equivalent of other Make ABB or Schneider as approved by GE. (v) Digital time switch including three phase power contactor 40 Amps. Make :- Legrand Cat No. 412641 or equivalent as approved by GE & Power contactor Legrand Cat No. 412549 or equivalent as approved by GE -1 No. (vi) Indicator lamp (LED type) & bakelite fuse showing R,Y,B phase(set of three) - 1 No. (vii) Digital frequency meter 40-55 Hz - 01 Set.
(iii) INCOMING Thermal magnetic and microprocesser release MCCB 200 Amps, 4 Pole, breaking capacity , 36 KA , with front operated locking device - 1No. Make:- Legrand Cat.No.4202 48 or equivalent of other Make ABB or Schneider as approved by GE. (iv) OUTGOING (a) MCCB 4 Pole, 125 Amps, Thermal Magnetic Release, Ics = 100% of Icu, 415 Volts with rupturing capacity 16 KA -02 Nos. Make:- Legrand Cat.No.4200 16 or equivalent of other Make ABB or Schneider as approved by GE. (b) MCCB 4 Pole, 63 Amps, Thermal Magnetic Release, Ics = 100% of Icu, 415 Volts with rupturing capacity 16 KA -01 No. Make:- Legrand Cat.No.4200 13 or equivalent of other Make ABB or Schneider as approved by GE. (c) MCB 2 Pole, 32 Amps - 01 No. Make:- Legrand Cat.No.4086 17 or equivalent of other Make ABB or Schneider as approved by GE. (v) Digital time switch including three phase power contactor 40 Amps. Make :- Legrand Cat No. 412641 or equivalent as approved by GE& Power contactor Legrand Cat No. 412549 or equivalent as approved by GE -1 No. (vi) Indicator lamp (LED type) & bakelite fuse showing R,Y,B phase - 1 No. (vii) Digital frequency meter 40-60 Hz - 01 Set.
(iii) INCOMING Thermal magnetic and microprocesser release MCCB 125 Amps, 4 Pole, breaking capacity , 36 KA , with front operated locking device - 1No. Make:- Legrand Cat.No.4200 96 or equivalent of other Make ABB or Schneider as approved by GE. (iv) OUTGOING (b) MCCB 4 Pole, 63 Amps, Thermal Magnetic Release, Ics = 100% of Icu, 415 Volts with rupturing capacity 16 KA -02 Nos. Make:- Legrand Cat.No.4200 13 or equivalent of other Make ABB or Schneider as approved by GE. (c) MCB 2 Pole, 32 Amps - 01 No. Make:- Legrand Cat.No.4086 17 or equivalent of other Make ABB or Schneider as approved by GE. (v) Digital time switch including three phase power contactor 40 Amps. Make :- Legrand Cat No. 412641 or equivalent as approved by GE& Power contactor Legrand Cat No. 412549 or equivalent as approved by GE -1 No. (vi) Indicator lamp (LED type) & bakelite fuse showing R,Y,B phase - 1 No. (vii) Digital frequency meter 40-60 Hz - 01 Set.
Dismantling and taking down street light fittings any size and re-fixing again after erecting of LT pole etc complete all as specified and directed.
S&F junction box, in repair, of size 155 X 210 X 92 mm, made out of CRCA sheet 2 mm thick totally enclosed, dust and vermin proof, rain protected slanted roof top, door pasted with rubber gasket, water tight IP 65 protection single leaf shutter in front having proper lacking arrangements and painted with powder coating paint and suitable size of "connect well" stud terminal ( provision for socket bolting) - 05 Nos suitable for 415 volts, 50 Hz, 3 phase 4 wire internal wiring system including MCB SP, 6 Amps-01 No. , clamp made out of MS flat 30 X 5 mm , nuts, bolts, washers etc complete and mounted on security light pole complete all as directed. Make:- Hensel cat part No. DK 1616 G (with terminal) or equivalent as approved by GE.
Supply and fix, in repairs, 45 watt new generation energy saving and environmental friendly long life LED security light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP opening separate driver compartment with IP65 protection and impact resistance of IK07 on bldg wall with and including pipe bracket made out of GI tubing 32 mm bore medium grade ISI marked 1.20m long bent to shape & providing clamps 2 Nos made out of 50 x 6mm Flat iron/ MS clamps & 12mm dia bolts, nuts & washers etc and two coat painting of approved colour on brackets completely with and including synthetic enamel paint and connecting up with & including twin twisted copper flexible wire of suitable length complete all as specified & directed. Make:- Havells Cat part No. ENDURAPEARLNEOSL45WLED757PASYTOPC or equivalent model of make- Philips or Crompton or WIPRO or Bajaj as approved by GE.
M&L for earthing in replacement complete with galvanised steel earth plate electrode 600x600x6.0mm thick directly burried in the ground (earth pit not less than 2.25M deep below ground level) with top edge of earth plate not less than 1.50M deep below normal ground level, connected to galvanised iron strip 32x6mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel, 40mm bore GI pipe light grade including necessary fittings for protection of earthing strip, watering pipe 20mm bore GI medium grade, concrete chamber in PCC (1:4:8) type D-2 using 40 mm graded crushed stone aggregate, coping shall be in PCC (1:3:6) type C-1 using 20 mm graded crushed stone aggregate and internal surfaces of concrete chamber shall be given 12mm thick plaster in CM (1:4), funnel with wire gauge of 22 gauge (0.63 mm), 8 mesh per linear incl 50mm thick cover of RCC (1:2:4) type B-1 using 20mm graded crushed stone aggregate reinforced with 8mm dia TMT bars @ 75 mm C/C both ways, char coal dust and common salt all as shown in electrical plate No. 3 of SSR Part-I (2009) including all necessary excavation & earth work and removal of surplus soil to a distance n. exc 50M and providing connection points with MS/ GI bolts & washers as required and connection from earth test point to earth electrode with same GI earth strip alongwith protection pipe and testing on completion complete all as specified and directed. Note:- GI strip and protection pipe from earth electrode to test point max upto 7.50M shall be deemed to be included in the unit rates as quoted by the contractor.
M&L for earthing in replacement complete with galvanised steel earth plate electrode 600x600x6.0mm thick directly burried in the ground (earth pit not less than 2.25M deep below ground level) with top edge of earth plate not less than 1.50M deep below normal ground level, connected to gi earth wire of size 4 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel, 40mm bore GI pipe light grade including necessary fittings for protection of earthing strip, watering pipe 20mm bore GI medium grade, concrete chamber in PCC (1:4:8) type D-2 using 40 mm graded crushed stone aggregate, coping shall be in PCC (1:3:6) type C-1 using 20 mm graded crushed stone aggregate and internal surfaces of concrete chamber shall be given 12mm thick plaster in CM (1:4), funnel with wire gauge of 22 gauge (0.63 mm), 8 mesh per linear incl 50mm thick cover of RCC (1:2:4) type B-1 using 20mm graded crushed stone aggregate reinforced with 8mm dia TMT bars @ 75 mm C/C both ways, char coal dust and common salt all as shown in electrical plate No. 3 of SSR Part-I (2009) including all necessary excavation & earth work and removal of surplus soil to a distance n. exc 50M and providing connection points with MS/ GI bolts & washers as required and connection from earth test point to earth electrode with same GI earth strip alongwith protection pipe and testing on completion complete all as specified and directed. Note:- GI strip and protection pipe from earth electrode to test point max upto 7.50M shall be deemed to be included in the unit rates as quoted by the contractor.
M&L for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground and laid down through 20 mm PVC medium grade conduit complete with fixed to pole or any other indicated situation for loop earthing etc as required 4 mm dia galvanized iron or steel wire etc complete all as specified and directed.
Supply and fix, in repair, MCB DB 4 way sheet metal enclosure triple pole and neutral, IP 43 with metal door, 415 Volts with 200 Amp rated copper bus bar of suitable size and common neutral link and earth bar all enclosed on standard steel sheet flush mouting type factory fabricated complete without MCB but with and including enclosure, blank plate complete all as specified and directed .
Supply and fix MCB DB 8 way sheet metal enclosure SPN, IP 43 with metal door, 240/ 415 Volts with 200 Amp rated copper bus bar of suitable size and common neutral link and earth bar all enclosed on standard steel sheet flush mouting type factory fabricated complete all as specified and directed.
S&F 415 V, 10 KA "C' curve MCB TPN 63 Amps current capacity, in the DB complete with connection, testing and commissioning complete all as specified and directed. Make:- Legrand Cat No. 4086 83 or equivalent model of make L&T/ Havells/ ABB as approved by GE.
Supply & fix MCB SPN, 40 Amps, 'C' series, 240 volts, 50Hz, 10kA complete all as specified & directed. Make:- Legrand Cat No. 4086 18 or equivalent model of make L&T/ Havells/ ABB as approved by GE.
Supply & fix MCB SPN, 32 Amps, 'C' series, 240 volts, 50Hz, 10kA complete all as specified & directed. Make:- Legrand Cat No. 4086 17 or equivalent model of make L&T/ Havells/ ABB as approved by GE.
Supplying and fixing MCCB 4Pole, 160 Amps, Thermal Magnetic Release, Ics = 100% of Icu, 415 Volts with rupturing capacity 36 KA complete all as specified and directed. Make:- Legrand Cat.No.4203 37 or equivalent of other Make ABB or Schneider as approved by GE.
Dismantling ACSR/AAC conductor of any size from LT poles or distribution span etc complete all as specified and directed.
Dismantling cross arms of MS channel or angle sections etc, any size, brackets, clamps, nuts, bolts, washers from LT poles or distribution span etc complete all as specified and directed.
Dismantling existing unserviceable stay assembly and removing from site of work etc complete all as specified and directed.
Dismantling unserviceable earth wire ,guard wire with cradle of any size from LT over head line or service feeder or any distribution span and removing from site of work etc complete all as specified and directed.
Dismantling existing unserviceable insulators of any type or any size etc complete all as specified and directed.
Dismantling LT steel tubular poles and setting aside for re-use within 50 metres complete all as specified and directed. Note :- Excavation, earthwork, returning, filling, removal and PCC will be measured and paid for separately.
M&L for PCC 1:2:4 type B-2 using 40 mm graded stone aggregate as in filling in surface channels and drains etc complete all as specified and directed.
Schedule of credit amount of Rs. 1,23,200.00 to be deducted during AOC
SHIVALIK ENGINEERING WORKS
M/S SURINDER KUMAR MAHAJAN
C L BHATIA
M/S UnitedConstruction
mclayers mercantile private limited
Ashirwad Contractor and Supplier
Asha Enterprises
GUPTA ENGINEERING WORKS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .