Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.6 LAccepted-AOC | L1 | Accepted-AOC Being (L1) | |
| 2 | L2₹15.5 L+₹55,953 (3.74%)Rejected-Finance | L2 | Rejected-Finance Being other than L1 | |
| 3 | L3₹16.7 L+₹1.8 L (12.0%)Rejected-Finance | L3 | Rejected-Finance Being other than L1 | |
| 4 | L4₹17.8 L+₹2.8 L (18.9%)Rejected-Finance | L4 | Rejected-Finance Being other than L1 |
Tender Value
₹25.0 L
EMD Value
₹50,100
Closing Date
17 Sept 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) E/M Chakeri
GE (AF) E/M CHAKERI KANPUR 208008
COMPREHENSIVE MAINT / REPAIR OF CHLORINATION PLANT AND OTHER ALLIED WORKS INCLUDING REPAIR TO STORAGE WATER HEATER IN DOMESTIC AREA AT AF STN CHAKERI, KANPUR
2022_MES_548277_1
8580/E8
Open Tender
Electrical and Maintenance Works
Item Rate
274 days
GE (AF) E/M CHAKERI KANPUR
As per Tender Documents
8 documents required · 8 mandatory
₹500
GE (AF) E/M CHAKERI
₹50,100
Yes
23 Sept 2022
27 Aug 2022
19 Sept 2022
27 Aug 2022
17 Sept 2022
4 Sept 2022
Amount
Taking down carefully geyser (storage type) of any make of capacity 25/35/50 Ltrs at any height disconnecting electrically and mechanically from all existing line and opening complete including back plate, inner copper tank etc. de-scaling of copper tank, heating element and cleaning with Sulphuric Acid / de-scaling compound and reassembling and fixing in same position after necessary repair / replacement including replacement of old nuts & bolts and rubber gasket etc inside the geyser complete all as specified and directed. Note :- (i) Replacement of unserviceable spares shall be measured and paid seperately under relevant items of Schedule 'A' as supply only. (ii) Inspection of electric geyser any capacity, any type, any make for minor defect tightening of nut and bolts, connecting wire, pipe lines and rectifing the defects complete all as specified and directed.
Supply only heating element 2000 watt capacity push / screw type size triangular/Square/Oval as required at site with' O' ring including making electrical connection complete all as specified and directed. Make: Theeta/ Bajaj or other make as approved by GE.
Supply only thermostat switches ISI marked of any size / capacity including making connections complete all as specified and directed. Make: Theeta/ Bajaj/Racold.
Supply only indicating lamp round / triangular red / green 220 volt AC as required at site including electrical connections complete all as specified and directed.
S&F in repair of PVC connection 600 mm long with two nos nut adopter ISI marked for hot water complete all as specified and directed. Make: Paras/ Prayag or other make as approved by GE.
S&F in repair of PVC connection 750 mm long with two nos nut adopter ISI marked for cold water complete all as specified and directed. Make: Paras/ Prayag or any make approved by GE
S&F in repair of PVC connection 900 mm long with two nos nut adopter ISI marked for cold water complete all as specified and directed. Make: Paras/ Prayag or other make as approved by GE.
S&F in repair door assembly push type with 'O' ring for 25 ltrs capacities geysers complete all as specified and directed. Make: Bajaj/Summer cool or other make as approved by GE.
M&L in repair for soldering / brazing of inner tank of geyser of any type & capacity as required to make it functional complete all as specified and direected.
S&F in replacement of stop valve cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for GI pipe 15 mm dia bore complete all as specified and directed. Make: Sant / Leader / Zolloto.
All as per item No 10.00 above but Chromium plated.
Supply only in replacement, 3 core PVC sheathed copper conductor flexible cable of size 2.5 sqmm complete all as specified and directed. Make: Finolex / Polycab / Havells.
S&F inner steel tank of capacity 25 litre Geysers complete all as specified and directed. Make: Bajaj/Summer cool or other make as approved by GE.
S&F in replacement single pole and neutral enclosure 20 Amp with a two pin and earth plug and socket with one single pole MCB complete all as specified and directed. Make: Legrand/L&T/Siemens.
S&F in replacement single pole MCB 16 Amp 10 KA complete all as specified and directed. Make: Legrand/L&T/Siemens.
S&F in replacement pressure release valve of suitable size complete all as specified and directed.
S&F in replacement Fastener of suitable size complete all as specified and directed.
S&F Plug Top 5 Amp 3 pin 230 volt complete all as specified and directed. Make: Anchor/Plaza/SSK.
S&F in replacement electric water heater, storage typesteel body with copper inner tank and heating element upto 2 KW Capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, Connection piece etc complete all as specified and directed. Make: Racold/Bajaj/Usha/Havells Note: Old unserviceable geyser will be deposited in E/M store yard.
Repair / maintenance of chlorine granuals based dosing plant comprising dosing pump, agitator and 100 Ltr FRP tank (Make- Declibac) and connected pipe lines as per manufacturers reccomendation which include the following:- (i) Cleaning of chlorine plant room once in a week. (ii) Daily Checking of all Chlorination plants /testing of complete system for serviceability of plant. (iii) Daily Testing of chlorine at consumer end with medical authority and maintained chlorine test record . (iv) Minor repair/cleaning of PVC pipe line /NRV to make plant functional. (v) Routine maintenance and servicing of agitator of by using necessary lubricant, replacement of bush/bearing, alingning the shaft, key etc. complete all as specified and directed. Note : (a) Any other spares required for replacement shall be measured and paid under relevent item of Sch 'A' as supply & rate of fixing is deemed to be included. (b) If any defect found in plant contractor should rectify the defect with in 24 Hrs, if failed to rectify the decfect the contractor shall be liable to pay compensation Rs 500/- (Rupees five hundred only) per plant per day.
Supply only Gear motor 230 volt, 50 Hz for chlorine dosing pump complete all as specified and directed. Note:- Old unserviceable gear motor will be deposited in E/M store yard.
Supply only Roller assembly complete all as specified and directed.
Supply only PVC Pump tube as per sample complete all as specified and directed.
Supply only Injection check valve 3/8" size complete all as specified and directed.
Supply only Weightned suction line strainer 3/8" size complete all as specified and directed.
Supply only White suction /discharge tubing 3/8" size complete all as specified and directed.
Supply only Agitator motor with suitable capacity alongwith agitator shaft & impeller made poly propylene rigid 32 mm dia and 500 mm length complete complete all as specified and directed. Note:- Old unserviceable Agitator motor alongwith agitator shaft & impeller will be deposited in E/M store yard.
Supply only pumphead complete all as specified and directed. Note:- Old unserviceable pump head will be deposited in E/M store yard.
Supply only Check valve duck bill complete all as specified and directed.
Supply only dosing tank complete all as specifed and directed. Make: Declibac/Potter & watts/Rayalseema
Supply only Calcium based high strenght granular chlorination chemical having 65 % to 70 % active chlorine, whitish, free flowing, decomposes clear in water solution , free of foriegn matter , the chlorination chemical should contain appropriate quantities of dispersants, corossion inhibitors to prevent incrustation scaling in distribution systems, mercury and other heavy meatl conteminents in chlorination chemical must be Below Detectable Limit (BDL) complete all as specified and directed. Note:- (a)The item shall be supplied in sealed containers of appropriate capacity duly marked with date of manufacturing and batch no. of lot. (b)The Manufacturers test certificate shall be submitted along with each supply. (c) The item supplied shall not more than 02 week old from the date of manufacture.
M&L for rewinding of agitator motor of capacity 120 watts, 960 RPM single phase 230 V and using copper winding wire of existing gauge with necessary insulation material including testing after repair and refixing of the same complete all as specified and directed.
Gupta Constructions
PAWAN COOL CORPORATION
Manoj Electricals
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .