Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.9 LAccepted-AOC PLOT NO 102 GANDHI NAGAR NEAR RAILWAY STATION BHARATPUR 321001 RAJ | BHARATPUR | BHARATPUR | RAJASTHAN | 321001 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹34.9 L+₹18,115 (0.52%)Rejected-Finance | L2 | Rejected-Finance OTHER TAHN LOWEST | |
| 3 | L3₹36.3 L+₹1.5 L (4.43%)Rejected-Finance | L3 | Rejected-Finance OTHER TAHN LOWEST | |
| 4 | L4₹38.8 L+₹4.0 L (11.6%)Rejected-Finance 37 222 BUNDU KATRA AGRA UP | AGRA | UP | L4 | Rejected-Finance OTHER TAHN LOWEST | |
| 5 | Rejected-Technical PLOT NO L 7 KRISHNA KRIPA VILLAGE SIROLI JAGATPURA JAIPUR 303905 RAJASTHAN | JAIPUR | JAIPUR | RAJASTHAN | 303905 | - | Rejected-Technical THE FIRM IS ENLISTED BUT CATEGORY OF b(i) IS NOT ENLISTED IN FIRM |
| Sl No | Description | Qty | Unit | N.K. ENTERPRISES L3 | PD GUPTA AND COMPANY L4 | GOVIND CONSTRUCTION L1 | Rajesh Mishra L2 |
|---|---|---|---|---|---|---|---|
| 1.00 | Roughning surfaces of old concrete floor by picking , sweeping , clean and washing down with water to remove dust etc including brushing neat cement slurry with 3.00 Kg of cement per Sqm complete all as specified. | 2,100 | Sqm | 10 ₹21,000 | 10 ₹21,000 | 10 ₹21,000 | 5 ₹10,500 Lowest |
| 2.00 | M&L for screed bed or bedding layer 20 mm thick in cement mortar 1:3 mixed with water proofing liquid as per manufactur’s instructions finished even and smooth without using extra cement mixed with water proofing complete all as specified. | 800 | Sqm | 120 ₹96,000 Lowest | 150 ₹1,20,000 | 120 ₹96,000 Lowest | 180 ₹1,44,000 |
| 3.00 | M&L for screed bed or bedding layer 15 mm thick in cement mortar 1:4 mixed with water proofing liquid as per manufactur’s instructions finished even and smooth without using extra cement mixed with water proofing complete all as specified. | 1,300 | Sqm | 120 ₹1,56,000 | 100 ₹1,30,000 Lowest | 120 ₹1,56,000 | 120 ₹1,56,000 |
| 4.00 | Supply only water proofing compound ISI marked. | 85 | Ltr | 45 ₹3,825 Lowest | 100 ₹8,500 | 45 ₹3,825 Lowest | 50 ₹4,250 |
| 5.00 | M&L APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) land on primed surface by forced application complete all as specified.Side over laps shall be 75 mm and the end shall be 100 mm and all overlaps and joints shall be sealed by torch application including applying a coat of cold applied bitumen primer conferming IS:3384 @ 0.40 Kg/Sqm and applying hot blown bitumen spread @1.2 Kg/sqm complete all as specified. | 1,300 | Sqm | 450 ₹5,85,000 | 350 ₹4,55,000 | 420 ₹5,46,000 | 300 ₹3,90,000 Lowest |
| 6.00 | M&L for cutting grooves in stone walls 75 mm wide and 65 mm deep and shaping horizontal face of groove with cement mortar 1:3 complete all as specified. | 200 | RM | 10 ₹2,000 Lowest | 50 ₹10,000 | 10 ₹2,000 Lowest | 10 ₹2,000 Lowest |
| 7.00 | M&L for providing PCC (1:2:4) type B0 12.5 mm graded stone aggregate as in roof kerbs rounded or chamfered on edges or sloping of roof complete all as specified. | 3 | Cum | 3,000 ₹9,000 Lowest | 4,500 ₹13,500 | 3,000 ₹9,000 Lowest | 3,500 ₹10,500 |
| 8.00 | S&F rotational moulded polyethylene water storage tanks 500 litres capacity (cylindrical vertical with closed top) hoisted and fixed in position all as specified including locking arrangement for cover using MS flat 40x3mm and necessory fittings and including dismantling existing tank complete all as specified. | 15 | Each | 3,500 ₹52,500 | 2,800 ₹42,000 Lowest | 3,500 ₹52,500 | 3,500 ₹52,500 |
| 9.00 | S&F rotational moulded polyethylene water storage tanks 1000 litres capacity (cylindrical vertical with closed top) hoisted and fixed in position all as specified including locking arrangement for cover using MS flat 40x3mm and necessory fittings and including dismantling existing tank complete all as specified. | 10 | Each | 5,500 ₹55,000 Lowest | 6,000 ₹60,000 | 5,500 ₹55,000 Lowest | 7,000 ₹70,000 |
| 10.00 | Cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc. Disconnecting existing tanks, exc 250 ltr not exc 1000 ltr setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position complete all as specified. | 30 | Each | 50 ₹1,500 Lowest | 100 ₹3,000 | 50 ₹1,500 Lowest | 100 ₹3,000 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
8 Aug 2025, 3:00 pmClosed
GE Bharatpur
GE Bharatpur
ROOF TREATMENT WORK TO CERTAIN BLDG REPLACEMENT OF ASBESTOS SHEETS AND OTHER ASSOCIATED WORK REPAIR REPLACEMENT OF FALSE CEILING STONE JALI WORK AND REPAIR TO SECURITY LIGHT STREET LIGHT AND CONNECTED ITEMS AT RMS DHOLPUR UNDER GE BHARATPUR
2025_MES_719966_1
8515/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
GE Bharatpur
AS PER NIT
8 documents required · 8 mandatory
₹500
Yes
GE Bharatpur
₹90,000
Yes
25 Sept 2025
11 Jul 2025
11 Aug 2025
11 Jul 2025
8 Aug 2025
25 Jul 2025
11 Jul 2025 - 24 Jul 2025
Amount
Roughning surfaces of old concrete floor by picking , sweeping , clean and washing down with water to remove dust etc including brushing neat cement slurry with 3.00 Kg of cement per Sqm complete all as specified.
M&L for screed bed or bedding layer 20 mm thick in cement mortar 1:3 mixed with water proofing liquid as per manufactur’s instructions finished even and smooth without using extra cement mixed with water proofing complete all as specified.
M&L for screed bed or bedding layer 15 mm thick in cement mortar 1:4 mixed with water proofing liquid as per manufactur’s instructions finished even and smooth without using extra cement mixed with water proofing complete all as specified.
Supply only water proofing compound ISI marked.
M&L APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) land on primed surface by forced application complete all as specified.Side over laps shall be 75 mm and the end shall be 100 mm and all overlaps and joints shall be sealed by torch application including applying a coat of cold applied bitumen primer conferming IS:3384 @ 0.40 Kg/Sqm and applying hot blown bitumen spread @1.2 Kg/sqm complete all as specified.
M&L for cutting grooves in stone walls 75 mm wide and 65 mm deep and shaping horizontal face of groove with cement mortar 1:3 complete all as specified.
M&L for providing PCC (1:2:4) type B0 12.5 mm graded stone aggregate as in roof kerbs rounded or chamfered on edges or sloping of roof complete all as specified.
S&F rotational moulded polyethylene water storage tanks 500 litres capacity (cylindrical vertical with closed top) hoisted and fixed in position all as specified including locking arrangement for cover using MS flat 40x3mm and necessory fittings and including dismantling existing tank complete all as specified.
S&F rotational moulded polyethylene water storage tanks 1000 litres capacity (cylindrical vertical with closed top) hoisted and fixed in position all as specified including locking arrangement for cover using MS flat 40x3mm and necessory fittings and including dismantling existing tank complete all as specified.
Cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc. Disconnecting existing tanks, exc 250 ltr not exc 1000 ltr setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position complete all as specified.
S&F 20 mm bore Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 2 0mm-210gms) complete all as specified.
Takind down GI tubing of 20 mm dia and connection complete all as specified.
Cleaning and Refixing old steel tubing of 20mm and connections in new or old position (Walls, ceiling, floors, etc) complete all as specified.
S&F 20 mm dia galvanized pipes medium grade ISI marked with all fittings and fixed complete to wall and ceiling or laid in floors complete all as specified.
S&F in repair 20 mm bore Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified.
S&F in repair PVC SWR pipes 110 mm bore single socketed in any length with rubber ring joint fixed to wall or laid in trenches or in floors with steel clamps complete all as specified.
Demolitiion of brick work/stone boulder masonary, built in cement mortar or cement lime mortar including all quions arches,pillars etc but excluding ashlar facings,dressed stone work and precast concrete but excluding ashlar facingdressed stone work and precast concrete articles complete all as specified.
M&L for walling of random rubble, uncoursed well bonded bedded, and solidily hearted, built in cement mortar 1:6 complete all as specified.
M&L for walling of random rubble, uncoursed well bonded bedded, and solidily hearted, built in cement mortar 1:6.but except stone complete all as specified.
Extra over stone walling for hammer dressing to face stones and dressing,of face beds and joints, as specified, of random rubble walling uncoursed or brought up to courses with maximum depression on face from straight edge held against the dressed surface n. exc. 40 mm, on lime or sand stones complete all as specified.
Raking out joint of pointing to random rubble or polygonal rubble, un-coursed or brought up to courses built in cement mortar complete all as specified.
M&L for Flush pointing to Random rubble masonry, uncoursed or brought up to courses in cement mortar 1:4 complete all as specified.
M&L for plain cement concrete type B1 1:2:4 (20 mm graded stone aggregate) as in lintels upto 1.5 m clear span and other similar bands, plinth courses, string courses,parapets and railings upto 60 cm in height, copings, kneelers, apex stones bed plates, water troughs and the like including weathering, slightly rounded or chamfered anglesand throating, complete all as specified.
M&L for repairing the edge / corner of Chajja / roof projection of Ground and First Floor and similar work by removing plaster width / girth exc 200 mm but not exceeding 300 mm and making good with 10 mm thick rendering in cement mortar 1:3 to match with existing surface complete all as specified. Note: Scaffolding and formwork if any required deemed to be included in this item.
Taking down cement plaster of any description including racking out joints, hacking for kay scrubing down with water etc complete all as specified.
M&L for rendering 15mm thick in cement mortar 1:4 on stone masonry surfaces or on fair face of brick work of walls, finished even and smooth without using extra cement on edges/ Chajjas/Roof projection and simlar courses etc complete all as specified.
M&L for two coats of cement base painting on newly plastered surfaces of wall over a coat of cement primer incl preparation of surfaces complete all as specified.
Dismantling wrought iron or Mild steel work of any description not otherwise provided for complete all as specified.
Supply and fixing mild steel rolled sections such as angles etc. As in main and cross beam, hip and jack rafters,purlins where connected to common rafters and running rails and guides for sliding dorrs, fixed with angle cleats or other connected plates confirming to grad Fe 290 (Gde E-165) complete all as specified.
Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding,with and including either hooks,and hinges or steel hanging,door fittings (exclusive of steel sheeting or other covering,running rails and guides) and,hanging; also fastening and,fixing complete all as specified.
Dismantling of Asbestos cement (corrugated, semi corrugated etc,) sheets in roof coverings etc complete all as specified.
S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 MPa as in roof covering / cladding to wall, molding / folding in circular / semicircular of any position and height fixed with self tapping screws complete all as specified.
Dismantling of expanded metal any thickness or mesh fixed with steel, wood fillets if any complete all as specified.
S&F welded steel wire fabrics n exc 4Kg fitted to steel members complete all as specified.
Dismantling Wall Panelling and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets/plywood, any thickness, including cover fillets complete all as specified.
M&L 12 mm thick designer ceiling tiles of 595mm x595 mm in ceiling fixed with screw as per manufactures instructions, fixed with white powder coated galvanized iron grid with 24mm wide T-section exposed flanges comprising of main runner made from 0.33mm thick galvanized steel sheet & of size T 24x32mm and spaced at 1.2m c/c securely fixed to the structural soffits by hangers at 1.2m of GI wire 4mm dia fixed rawl plug, level adjusters and screws etc. The last hanger at the end of each main runner shall not be greater than 450mm from adjacent wall flush fitting of 1200mm long cross tee with (double stitching) to be inter locked between main runners at 600mm c/c to form 600x600mm modules, angle along perimeter wall shall be of 0.45mm thick galvanized steel of size 19x19mm of white colour all as per instruction complete all as specified.
S&F PVC wall panelling with panel of 300 mm x 6 mm Hollow section of Sintex pattern SPUF- 146 or equivalent , fixed with PVC plug and screw and inserted to next panel groove, edges and corners of all door/ window/openings etc to be covered with PVC angel fixed with solvent cement complete all as specified as manufacturer's Instructions.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified.
Non skid coloured ceramic tiles area of each tiles exceeding 0.18 Sqm but not exceeding 0.38 sqm 7 to 8 mm thick joint less in floor/skirting set in neat cement slurry and pointed with coloured/white cement to match the surface complete all as specified.
M&L Screed bed or bedding layer of mortar 15 mm thick in CM 1:6 for laying floor finishes complete all as specified.
Dismantling of RCC Jali,Stone Jali & Stone Pillar of any description , any thickness complete all as specified.
M&L for 40 mm thick Sikandra stone jali decorative design of approved pattern by GE including all carving and moulding of corners fixed in cement mortar 1:4 to grooves of stone pillars application with colouring to match with colour of jali including fixing of stone jali for all corners & lift complete all as specified.
S&F stone pillars(post) of size 100x100 mm including engraving decorative design of approved pattern on two face and dome shape approved by GE, height of each post as per sikandra stone jali, ,making groove on two face of size 43x5 mm for fixing of sikandra Jali in CM 1:4 complete all as specified.
Excavation in trenches, n. exc 1.5 Mtr wide and n. exc 1.5 Mtr in depth for foundation / laying of cable and getting out in soft disintigrated rock/any type of soil complete all as specified.
Excavation in trenches, not exc1.5 Mtr wide but exc 1.5m and n. exc 3Mtr in depth for foundation/laying of cable and getting out in soft disintigrated rock/any type of soil complete all as specified.
Removing of excavated rock/soil to a distance n. Exc 50 Mtr and depositing where directed at a level n. Exc 1.5 Mtr above the starting point complete all as specified.
Returning, filling in including spreading, levelling, watering and well ramming in layers n. Exc 25 cm thick complete all as specified.
Supply & laying unwashed local river sand for sand cushioning and covering the under ground cable in trenches complete all as specified. (Note :- Punned thickness shall be measured.)
M&L for brick protection with sub Class`B` bricks old size laid dry, flat over cable perpendicular across the cable in trenches complete all as specified.
M&L for PCC (1:3:6) type C2 using 40mm grade stone aggregate in foundation and mass concrete complete all as specified.
M&L for PCC 1:2:4 type B1 using 20mm graded stone aggregate in coping of existing/new poles / foundation for poles, struts, posts etc including necessary form work, finished the exposed surfaces fair and even without using extra cement complete all as specified.
Supplying, errecting and fixing steel tubular swaged poles with cast iron base plate of size 300mm x 300mm x 6mm, finial taper plug, bolts, nuts & screws for type 410 SP-31 (9.0 metres long) including painting with two coats of aluminium paint over one coat of redoxide primer on all exposed surfaces and tarring with black bituminous paints to embedded portion in PCC and providing 3 Nos of 30cm wide circular bands alternate with black & yellow paint starting from plinth level at a gap of 30 cm in between 2 bands and numbering of poles, in yellow paint over black painted back ground at a height of 2m from bottom of pole with 5 cm large bold letters 2" (inch) wide including taking down old unserviceable PCC poles of any type complete all as specified. Note: Excavation, earth work, PCC in foundation and coping shall be measured and paid separately under relevant item of this schedule.
S&F in repair LED surge protector multiple type 2 surge arrestors with thermal monitaring device and connector,dual visual fault indicator for the discharge path of the supply voltage and control the phase complete all as specified.
S&F in repair LED drivers rated voltage 12/24 volt max out put power Panel Driver 15 W / 18 W complete all as specified.
S&F in repair LED drivers rated voltage 12/24 volt max out put power 45 W complete all as specified.
S&F in repair LED drivers rated voltage 12/24 volt max out put power 70 W complete all as specified.
S&F in repair LED drivers rated voltage 12/24 volt max out put power 90 W complete all as specified.
M&L for taking down and refixing after serviving of existing solar lights panels of any capacity , removal of dust , cleaning of solar panels thoroughly , tighening of any loose fixing arrangement, opening of main body and cleaning of debris , replacement of burnt wire, Replacement of MPPT and unsv Battery complete all as specified. Note: (i) Spare parts/accessories required to be replace shall be measured and paid seperately as "supply only" under the relevent items. (ii) Scope of work including for minor stores ie. PVC insulation tap, screw, insulation sleeve, nut bolt & washer and flexible cable if required any. (iii) Any complaint measured one time in same location/pole/light during contract period. No extra payment will be made for repeating complaint on same location during contract period. (iv) The rate including all the T&P of i.e. ladder/vehicle/required for execution of work shall be arrange by the contractor.
Supply only following items in repair/replacement of above solar lights :-
(a) Supply only battery of rating 12.8V 30/33Ah for lithium base energy efficient integrated solar street light as per standard and compitable for existing solar light complete all as specified.
(b) Supply only Metal core PCB of lithium base energy efficient integrated solar street light as per standard and compitable for existing solar light complete all as specified.
(c) Supply only MPPT charge controller of lithium base energy efficient integrated solar street light as per standard and compitable for existing solar light complete all as specified.
S & F street light GI bracket of 0.9 mtr long made out of 40mm dia light grade GI pipe bend to shape of 120 degree end welded at required including 02 Nos MS clamp of FL 40 x 6mm including nuts bolts & washers complete necessary fixing arrangements on pole and including Dismantling old U/S GI bracket of any size & length complete all as specified.
Taking out and S & F in replacement 4 sqmm solid conductor 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed twin core cable flat or circular from junction box to fitting complete all as specified.
Taking out old UNSV GI Pipe of any make & size complete all as specified.
S & F or laying galvanised steel tubing Light grade (ISI marked) for protection of under ground cable on poles/walls under road crossing of size 40 mm bore complete all as specified.
S&F in replacement of 50 mm dia steel tubes (light grade) galvanised with fittings, laid in trenches / wall for protection of underground cable when crossing the road complete all as specified.
Taking out old UNSV LT UG cable of any make & sizeof 10/6 sqmm 2 core complete all as specified.
Taking out old UNSV LT UG cable of any make & size of 16/25 sqmm 4 core complete all as specified.
Supply, laying, testing & commissioning LT XLPE insulated armoured (heavy duty) electric cable with stranded aluminium conductor 1100 volts grade (ISI marked) & laid in trenches/pipes or fixed on pole of the following sizes:-
(a) 25 Sqmm 4 core
(b) 16 Sqmm 4 core
(c) 10 Sqmm 2 core
Supply, install, test and commissioning factory made THERMOPLASTIC/HDPE CABLE JUNCTION BOXES IP 66/67 “weather proof”, with terminals for outdoor installation (with knockouts for cable entry) of size 280 x 170 x 105 mm depth with cable entry size of 10-25 sqmm with 4 No. busbar of capacity 63 Amp and MCB SP 6 Amp-1 No.of make sintex each, with flat iron clamps of size 30 x 6mm, nuts and bolts complete including taking down old juction box complete all as specified.
S&F in repair on existing location including taking out of existing MCCBs of following capacity :-
(a) MCCB 415 volts 125 Amps 04 pole 16 KA
(b) MCCB 415 volts 100 Amps 04 pole 16 KA
(c) MCCB 415 volts 63 Amps 04 pole 16 KA
S&F in replacement of 3 Pole 40 Amp power contactor, AC 3 rating, fixed in existing panel & connecting complete all as specified. Make: L&T / Legrand /Siemens/ABB
S&F of "Lithium based Energy Efficient Integrated Solar Street Light of 40 Watt"in Single aluminium housing body , encases with Monocrystaline Solar PV Panel of minimum 40 Wp, Lithium Battery 11.1/12.8V, 33/36AH with inbuilt BMS, IP 65, high brightness, CRI>70, Color temperature 5700-6500K, Microcontroller based charge controller cum driver, automatic dimming function, Dusk to Dawn Operation, suitable to working temperature:(-) 10 degree celcius to (+) 55 degree celcius with adjustable MS clamp and suitable for pole/wall mounting etc complete as required. Protection: Short Circuit, overload, Reverse polarity and battery protections complete including taking down all as specified.
Re-stringing ACSR conductor of street light feeder (1ph and neutral) any type size stringing properly on insulator and binding with aluminium tape/connectors, jumpers etc drawing as OH/LT line including dismantling/taking down old u/s ACSR conductor from poles including jumper and cable connection etc complete all as specified.
S&F in replacement timer switch 24Hrs Analog dial type suitable for street lights and high mast lights with complete assembly 63Amps capacity including taking out the old UNSV one any size and type complete all as specified.
Material and labour for renewal of copper Earthing complete with copper earth plate electrode of size 60x60cmx5mm thick buried directly in ground (earth pit should not less than 4 mtr deep below normal ground level ) with top edge of the plate not less than 2.95 mtr deep below normal ground connected to and included copper earth strip 20mmx 3mm by means of copper bolts nuts check nuts and washer returning and filling the pits with excaviated vsoil mixing with charcoal 250 kg crystal salt 200 kg magnisiun sulphate of 100 kg and vegitable soil all around the plate up to 350 mm above from top edge of plate and balence portion filling with excaviated soil in layers not exc 25 mm thick 25 mm bore galvanised iron medium grade watering pipe up to top of plate 50mm bore galvanised iron light grade pipe for earth strip protection including all excavation earth work in any type of soil pcc 1;3;6 type c1 ....for chamber of internal size 300mmx 300mmx300mm with 120mm thick wall and 700mmx700mmx150mm thick bed concreat RCC 1:2:4 ,type b1 for precast chamber cover 50mm thick reinforced with welded steel wire fabric orxPM jali (weight not less than 4.00 kg/sqmm) ,funnel,with wire mesh complete all as specied. Note (i) Quoted rate shall be deemed to include for earth strip with protection pipe up to 7.5 M length
M&L of painting of pole intially with single coats of primer paint on exposed surfaces after scraping old deterirorated paint and after that providing 3 Nos of 30cm wide circular bands with black & yellow paint starting from plinth level at a gap of 30 cm in between 2 bands and numbering of poles, in yellow paint over black painted back ground at a height of 2m from bottom of pole with 5 cm large bold letters wide complete all as specified.
Taking down and S&F 200 watts LED flood light fitings new generation energy saving, environmental friendly, long life, versatile pressure die cast aluminium IP66 with 10KV surge protection road way, luminaire with high power LED as light source and suitable drivers etc to complete all as specified.
Taking down and S&F 100 watts warm white LED flood light fitings new generation energy saving, environmental friendly, long life, versatile pressure die cast aluminium IP66 with 10KV surge protection road way, luminaire with high power LED as light source and suitable drivers etc to complete all as specified.
Taking down and S&F 70 watts LED flood light fitings new generation energy saving, environmental friendly, long life, versatile pressure die cast aluminium IP66 with 10KV surge protection road way, luminaire with high power LED as light source and suitable drivers etc to complete all as specified.
Taking down and S&F 90 watts LED street light fitings new generation energy saving, environmental friendly, long life, versatile pressure die cast aluminium IP66 with 10KV surge protection road way, luminaire with high power LED as light source and suitable drivers etc to complete all as specified.
Taking down and S&F 60 watts LED street light fitings new generation energy saving, environmental friendly, long life, versatile pressure die cast aluminium IP66 with 10KV surge protection road way, luminaire with high power LED as light source and suitable drivers etc to complete all as specified.
M&L for road cutting in 300mm width & 450 mm depth & repair to match existing with bitumen premixed incl 150 mm BM complete all as specified.
M&L for Cutting, trimming and prunning of trees, branches of any girth all around existing LT over head lines including cleaning the disturbed area beneath the LT overhead lines/LT Poles and removing the creepers/climbers tree branches and debris from site and depositing where directed at site. .
Disconnecting and taking down High Mast light from the steel tower and repair of High Mast fitting of any type, capacity & make by replacement of spare parts & making the fitting functional and refixing after repairs complete all as specified. Note : (i) Spare parts/accessories required to be replace shall be measured and paid seperately under the relevent items. (ii) Scope of work including for minor stores ie. PVC insulation tap, screw, insulation sleeve, nut bolt & washer (iii) Any complaint measured one time in same location/pole/light during contract period. No extra payment will be made for repeating complaint on same location during contract period. (iv) The rate including all the T&P of i.e. ladder/vehicle/required for execution of work shall be arrange by the contractor.
Supply and fix / draw PVC insulated and sheathed trailing cable copper conductor cable of size 2.5 Sqmm 5 core, EPR PCP round cable 1100 volt grade. Including taking down old cables complete all as specified.
M&L for Repairing of 1 HP capacity electric motor of high mast, AC 3 phase, dismantling the motor cutting and taking out the old winding wires, cleaning the slots, rewinding the motor with appropriate size of super insulated copper conductor winding wire of same gauge, and varnishing complete including replacing the worn out bearing reassembling the motor fixing in same position and testing complete all as specified.
Supply only wire rope of high mast light from winch to top made out of stainless steel grade AISI 316 sutable for taking min 750 kg load / as per existing rope size including taking down complete all as specified.
Supply and fix MCB’s tripple pole & neutral 63 Amps, 415 volts with ‘C’ curve, fixed in sheet metal board complete including taking down complete all as specified.
Supply and fix MCB’s single pole 6-32 Amps, 230 volts with ‘C’ curve, fixed in sheet metal board complete including taking down complete all as specified.
Supply jointing connecting in repair and testing, straight through joint, epoxy based complete with jointing material and all standard accessories suitable for XLPE insulated armoured aluminium conductor cable, LT 1100 Volts, aluminium conductor of 10/16/25 Sqmm suitable for 3.5/ 4 core complete all as specified.
Taking down old bollard light and S&F in repairs decorative colour of 3 mtr length having pole material GI PU painted pipe and light material as polycarbonate acrylic of length as per Halonix Cat Part No HLDC-45-75-TRI-3M with rated voltage and frequency 240V 150 Hz, system voltage 75W ±10%, system current <0.382mA power factor >0.90 colour out put suffron, white & green (Tiranga colour with same sequence) and driver efficiency ≥80%. Base plate of the pole light shall be of dia 300mm and thickness 12mm PCB hole 260mm dia & 25mm dia light shall be mounted on a half feet PCC plaster, properly fixed with plate and foundation bolts. Make : Halonix, Havells, Bajaj or equivalent as approved by GE.
Rajesh Mishra (BID ID -3379909)
N.K. ENTERPRISES (BID ID -3379353)
PD GUPTA AND COMPANY (BID ID -3386779)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .