| Sl No | Description | Qty | Unit | SAI COOL SERVICES L1 | R.A.ENTERPRISES L3 | Vijay Traders L2 |
|---|---|---|---|---|---|---|
| 1.00 | SITC of floor mounted chilled water double skin air handling unit construction, 25 mm thick insualted PUF panels, IP 55 TEFC IE2 motors, DIDW fan or PLUG Fan with VFD, chilled water cooling coil, Insulated drain pan, Pre-filter section, vibration isolators, canvas connections, with Frame Work etc
of 6000 - 7000 CFM 8Rows | 1 | Nos. | 10,75,000 ₹10,75,000 Lowest | 11,30,000 ₹11,30,000 | 11,00,000 ₹11,00,000 |
| 2.00 | SITC of floor mounted chilled water double skin air handling unit construction, 25 mm thick insualted PUF panels, IP 55 TEFC IE2 motors, DIDW fan or PLUG Fan with VFD, chilled water cooling coil, Insulated drain pan, Pre-filter section, vibration isolators, canvas connections, with Frame Work etc of 7000 - 8000 CFM 8Rows | 1 | Nos. | 11,25,000 ₹11,25,000 Lowest | 11,70,000 ₹11,70,000 | 11,50,000 ₹11,50,000 |
| 3.00 | Air cooled ducted type A/C unit Nominal Capacity 5.5 TR | 2 | Nos. | 1,50,000 ₹3,00,000 Lowest | 1,65,000 ₹3,30,000 | 1,75,000 ₹3,50,000 |
| 4.00 | S & I of Timer for AC units | 1 | Nos. | 15,000 ₹15,000 Lowest | 16,000 ₹16,000 | 16,000 ₹16,000 |
| 5.00 | VRF / VRV ACequipments : SITC of Capacity (R-410A /R-407c or eco-friendly Refrigerant) Air Cooled type outdoor units of VRF system having hermetically sealed scroll inverter compressor, condenser coil fabricated from Seamless Copper tube & Plate type Al. Fins of Multi Row, Axial Flow, upward throw condenser fan, Condenser fan - motor unit, insulated refrigeration piping, power / control wiring, and earthing, external wiring between Indoor & Outdoor units, all system controls-safety. Each Outdoor units with High Pressure switch, Fan driver overload protector, Over current relay, Inverter Overload Protector & Fusible Plug. The unit shall be suitable for 415 ± 10 % volts, 50 Hz, 3 phase AC supply, and IP 55 protection. The out door unit shall be installed on M.S. platform duly painted, as per specifications. VRF / VRV AC equipments 20 HP | 1 | Nos. | 7,00,000 ₹7,00,000 Lowest | 7,20,000 ₹7,20,000 | 7,25,000 ₹7,25,000 |
| 6.00 | VRF / VRV AC equipments : SITC of Capacity (R-410A /R-407c or eco-friendly Refrigerant) Air Cooled type outdoor units o of VRF system having hermetically sealed scroll inverter compressor, condenser coil fabricated from Seamless Copper tube & Plate type Al. Fins of Multi Row, Axial Flow, upward throw condenser fan, Condenser fan - motor unit, insulated refrigeration piping, power / control wiring, and earthing, external wiring between Indoor & Outdoor units, all system controls-safety. Each Outdoor units with High Pressure switch, Fan driver overload protector, Over current relay, Inverter Overload Protector & Fusible Plug. The unit shall be suitable for 415 ± 10 % volts, 50 Hz, 3 phase AC supply, and IP 55 protection. The out door unit shall be installed on M.S. platform duly painted, as per specifications. VRF / VRV AC equipments 18 HP | 1 | Nos. | 6,75,000 ₹6,75,000 Lowest | 6,90,000 ₹6,90,000 | 6,75,000 ₹6,75,000 Lowest |
| 7.00 | Indoor Units :- Large cassette type for VRF 4 TR Four way Cassette Type | 4 | Nos. | 62,000 ₹2,48,000 Lowest | 64,000 ₹2,56,000 | 65,000 ₹2,60,000 |
| 8.00 | Indoor Units :- Large cassette type for VRF 3 TR Four way Cassette Type | 1 | Nos. | 60,000 ₹60,000 Lowest | 62,000 ₹62,000 | 65,000 ₹65,000 |
| 9.00 | Indoor Units :- Large cassette type for VRF 2.8 TR Four way Cassette Type | 3 | Nos. | 58,000 ₹1,74,000 Lowest | 62,000 ₹1,86,000 | 65,000 ₹1,95,000 |
| 10.00 | Indoor Units :- Large cassette type for VRF 2.0 TR Four way Cassette Type | 1 | Nos. | 55,000 ₹55,000 Lowest | 60,000 ₹60,000 | 60,000 ₹60,000 |
Tender Value
Refer Docs
EMD Value
₹2.4 L
Closing Date
4 Sept 2025, 4:00 pmClosed
Ex.Eng.Mech.Ref
Municipal Workshop, 103, R.S.Nimkar Marg, Byculla
The work of Replacement of air conditioning system at various locations at Bharatratna Dr. Babasaheb Ambedkar Municipal General Hospital, Kandivali (W).
2025_MCGM_1210003_1
DY CH ENGG M E /1126/ CITY
Open Tender
Electrical and Maintenance Works
Item Rate
365 days
BDBA Hospital Kandivali
Please refer Tender documents.
3 documents required · 3 mandatory
₹21,417
₹2.4 L
Municipal Workshop, 103, R.S.Nimkar Marg, Byculla
23 Sept 2025
15 Aug 2025
8 Sept 2025
15 Aug 2025
4 Sept 2025
15 Aug 2025
21 Aug 2025
Amount
SITC of floor mounted chilled water double skin air handling unit construction, 25 mm thick insualted PUF panels, IP 55 TEFC IE2 motors, DIDW fan or PLUG Fan with VFD, chilled water cooling coil, Insulated drain pan, Pre-filter section, vibration isolators, canvas connections, with Frame Work etc of 6000 - 7000 CFM 8Rows
SITC of floor mounted chilled water double skin air handling unit construction, 25 mm thick insualted PUF panels, IP 55 TEFC IE2 motors, DIDW fan or PLUG Fan with VFD, chilled water cooling coil, Insulated drain pan, Pre-filter section, vibration isolators, canvas connections, with Frame Work etc of 7000 - 8000 CFM 8Rows
Air cooled ducted type A/C unit Nominal Capacity 5.5 TR
S & I of Timer for AC units
VRF / VRV ACequipments : SITC of Capacity (R-410A /R-407c or eco-friendly Refrigerant) Air Cooled type outdoor units of VRF system having hermetically sealed scroll inverter compressor, condenser coil fabricated from Seamless Copper tube & Plate type Al. Fins of Multi Row, Axial Flow, upward throw condenser fan, Condenser fan - motor unit, insulated refrigeration piping, power / control wiring, and earthing, external wiring between Indoor & Outdoor units, all system controls-safety. Each Outdoor units with High Pressure switch, Fan driver overload protector, Over current relay, Inverter Overload Protector & Fusible Plug. The unit shall be suitable for 415 ± 10 % volts, 50 Hz, 3 phase AC supply, and IP 55 protection. The out door unit shall be installed on M.S. platform duly painted, as per specifications. VRF / VRV AC equipments 20 HP
VRF / VRV AC equipments : SITC of Capacity (R-410A /R-407c or eco-friendly Refrigerant) Air Cooled type outdoor units o of VRF system having hermetically sealed scroll inverter compressor, condenser coil fabricated from Seamless Copper tube & Plate type Al. Fins of Multi Row, Axial Flow, upward throw condenser fan, Condenser fan - motor unit, insulated refrigeration piping, power / control wiring, and earthing, external wiring between Indoor & Outdoor units, all system controls-safety. Each Outdoor units with High Pressure switch, Fan driver overload protector, Over current relay, Inverter Overload Protector & Fusible Plug. The unit shall be suitable for 415 ± 10 % volts, 50 Hz, 3 phase AC supply, and IP 55 protection. The out door unit shall be installed on M.S. platform duly painted, as per specifications. VRF / VRV AC equipments 18 HP
Indoor Units :- Large cassette type for VRF 4 TR Four way Cassette Type
Indoor Units :- Large cassette type for VRF 3 TR Four way Cassette Type
Indoor Units :- Large cassette type for VRF 2.8 TR Four way Cassette Type
Indoor Units :- Large cassette type for VRF 2.0 TR Four way Cassette Type
2C X 1 sqmm Communication shielded Cable
SITC of Seamless heavy gauge refrigeration Copper piping for VRF/ VRV system in 18 gauge, duly insulated with 13 mm/19 mm thickness. Nitrile Rubber Insulation. Refrigeration piping will have to be taken in the piping rack / Support individually connecting to Indoor units, including necessary supports, fittings, valves, Cable tray for exposed piping where ever required will be included.. The pipe sizes from 1/4 " to 1".(13 mm insulation) and 1-1/8 " to 2"(19 mm insulation) shall be used.
Supply, Installation, Testing and Commissioning of Refnets as specified of pipe sizes from 1/4 " to 2"
S & I of MS stands for VRF / ductable / package AC outdoor units.
GSS Ducting:- Supplying fabrication installation testing and commissioning of GI. Sheet metal ducting. Zinc coated. Complete with all Standard Accessories, G.I.. Hardware, Self Adhesive elastomeric foam gasket, Support etc as per SMACNA specification GSS Ducting 24 Gauge
GSS Ducting:- Supplying fabrication installation testing and commissioning of GI. Sheet metal ducting. Zinc coated. Complete with all Standard Accessories, G.I.. Hardware, Self Adhesive elastomeric foam gasket, Support etc as per SMACNA specification GSS Ducting 22 Gauge
Providing thermal insulation to supply air ducting with 19mm.thickness nitrile rubber
SITC of the Vertical laminar air distribution ceiling (surgical module) suitable for Operating Theaters rooms
Providing & fixing of Canvas Connections for units.
Supply and installation of volume control dampers, bypass dampers.
S & I of Cubical panel for chilled water AHU/ Refrigeration unit
S & I of Control Panel for DX AHU/ Packaged/ Precision AC Units
40A FP MCB
IP43 4 Way TPN DB (8 + 12Way)
Indoor LED fixtures -LED Square Recessed Downlighter- 36W (600X600)
Light /Fan / Ex. fan Points Concealed Manner with Modular switches & FR wires
Supply & fixing acoustic partition in the Plant room/AHU room
Providing aluminium supply air diffusers & return air grills with volume control dampers
Supply installation of M.S. 'C' class chilled water pipe line/drain line along with accessories and thermal insulation of nitrile rubber with glass cloth 65 mm diameter with insulation of 19 mm thk nitrile rubber insulation
Supply & installation of following accessories on the chiller water pipe inlet outlet line duly insulated with 50mm thick thermocol 65 mm diameter, Butterfly valve
Providing,fixing. testing & commissioning of following of 2- way mixing valve of following dia with actuator and proportioning thermostat Providing,fixing. testing & commissioning of 2- way mixing valve of-65 mm diameter
Y strainer-65 mm diameter
Supply and fixing of diaphragm type pressure gauges with necessary fitting and gate valve on chiller water inlet and outlet lines
Providing Digital temperature indicator with thermowell and senser on chiller water pipe line inlet, outlet and for return air
Ball valves 25 mm diameter
Replacement of accoustic partition in the plant room
S & I of Aluminium cladding for chilled water pipes
MS structure for AC works
Providing & fixing of Drain piping as per specification.
Replacement of existing damaged false ceiling by new aluminum false ceiling sheets along with grid work
Supply and fixing 12 mm thick Marine Ply Plank
To make opening in the walls for laying of chilled water piping / drain piping, supply air duct, cable etc.& making them good as per original appearance
1st category Cu armoured cables FRLS outer sheathed- 4C x 4 Sq.mm
1st category Cu armoured cables FRLS outer sheathed- 4C x 25 Sq.mm
1st category Cu armoured cables FRLS outer sheathed- 4C x 10 Sq.mm
Dismantling old Air Handling Unit and its accessories
Removing/ Dismantling of old 1.0/ 1.5 TR/ 2.0 window/ split AC/ FCU/ Cassette unit.
1st category Cu armoured cables FRLS outer sheathed- 3C x 2.5 Sq.mm
1st category Cu armoured cables FRLS outer sheathed- 6C x 1.5 Sq.mm
GI Earthing 10 SWG
Providing fresh air damper with crowl piece,bird screen and removable type prefilters
SITC of scaffodling
SITC of fins tube type Heater for 1 KW heater as per specifications.
Rebate 2TR Split AC
Rebate 1.5 TR Split AC
Rebate for old AHU and its accessories CFM 2000 - CFM 7000
Vijay Traders (BID ID -6839098)
R.A.ENTERPRISES (BID ID -6842003)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .