Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.5 LAccepted-AOC 25 AZAD CHOWK SADAR BAZAR JABALPUR 482001 | JABALPUR | JABALPUR | MADHYA PRADESH | 482001 | L1 | Accepted-AOC L1 bidder lowest | |
| 2 | L2₹36.0 L+₹51,023.10 (1.44%)Rejected-Finance 1782 1 NEW SHOBHAPUR COLONY VFJ ROAD JABALPUR MP 482009 | JABALPUR | MADHYA PRADESH | 482009 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹37.3 L+₹1.7 L (4.86%)Rejected-Finance H NO 114 A 10 GHAZI NAGAR RADDI CHOWKI GOHALPUR JABALPUR MP | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹40.9 L+₹5.4 L (15.2%)Rejected-Finance 114 BARH CHONDI TOWN BARH DISTT PATNA BIHAR PIN 803213 | PATNA | BIHAR | 803213 | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹79.4 L+₹43.9 L (123.6%)Rejected-Finance 2284 30 BAJRANG NAGAR VFJ ESTATE JABALPUR 482009 | JABALPUR | MADHYA PRADESH | 482009 | L5 | Rejected-Finance Other than L1 |
Tender Value
₹43.9 L
EMD Value
₹87,800
Closing Date
26 Sept 2024, 6:00 pmClosed
GE (West) Jabalpur
Garrison Engineer (West) Jabalpur Supply Marg Post Box No. 54 Jabalpur Cantt-482001 (MP)
PROVN OF COVERED PARKING SHED WITH HARD STANDING NEAR MAIN GATE ENTRANCE AT NURSING OFFRS OF MH AND PROVN OF THREE PHASE ELECTRIC CONNECTION IN THE GRC OFFRS MESS AND CERTAIN MINOR WORKS IN THE AREA OF AGE B/R-III UNDER GE (WEST) JABALPUR
2024_MES_672307_1
8782/E8
Open Tender
Civil Works
Item Rate
180 days
GE (West) Jabalpur
As per tender documents
6 documents required · 6 mandatory
₹500
GE (West) Jabalpur
₹87,800
22 Nov 2024
5 Sept 2024
28 Sept 2024
5 Sept 2024
26 Sept 2024
12 Sept 2024
5 Sept 2024 - 7 Sept 2024
Amount
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft/loose soil complete all as specified and directed.
Excavation in trenches not exc. 1.5 mtr deep and 1.5 mtr wide soft/loose soil and getting out complete all as specified and as directed.
M & L excavation in post holes (or similar holes) each n. exc 0.5 cum, getting out in soft/loose, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm complete all as specified and directed.
M & L for Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified and directed.
M & L for PCC 1:4:8 type D-2 ( using 40mm graded stone aggregate ) as in fdn filling and mass concrete complete all as specified and directed.
M & L for Hardcore of gauge exc 63mm but n exc. 100 mm, deposited, spread and lev- elled in layers n exc. 15 cm thick, watered and rolled/ rammed to a true surface complete all as specified and directed.
M&L for 75mm thick PCC type D-2 ,1:4:8 (using 40mm graded stone aggregate) as in sub base to floor complete all as specified and as directed.
M&L for 100 mm thick PCC 1:2:4 ,Type B2 ,using 40 mm graded aggregate as in paving /path finished fair and even complete all as specified and as directed.
S&F rolled section as in main and cross beam ,hip and jack rafters ,purlin where connected to common rafters and running rails and guides for sliding doors ;fixed for sliding ;fixed with angle cleats or other connecting plates complete all as specified and directed.
M & L for Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 complete all as specified and directed.
S&F Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment Fe- 290 (Gde E-165)complete all as specified and directed.
S & F mild steel bolts exc 11 but n exc 15 mm dia, purpose made with hexagonal or square head one end and screwed the other, or screwed both ends; each screwed end to be fitted with washers and one hexagonal or square nut. Exc 30cm long complete all as specified and as directed.
S& F Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and as directed.
S&F for Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, or for valley gutter fixed with self tapping screws as specified complete all as specified and as directed.
S&F hand rails, half rounded or other stock section or core for wooden hand rail straight portion, drilled and counter sunk for balusters, nosing to steps including embeding in concrete and screwing etc wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire etc; flat iron fillets (for securing wire mesh etc,) including all necessary drilling bolting or riveting, etc and similar work conforming to Fe 410-0 or Fe 310-0 complete all as specified and directed.
M & L for preparation of new or previously untreated surfaces of steel of any des-cription, over 10cm in width or grith and applying two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
M & L for preparation of new or previously untreated surfaces of of steel of any description, n.exc 10cm in width or girth when unconnected with other painting or when painted in a different tint and applying two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed..
M/L for brick work with kiln burnt bricks of old size built in CM 1:4 using sub class 'B' bricks of compressive strength not less than 35 Kg/Sqcm straight or curved on plan exceeding 6 mtr mean radius complete all specified and as directed.
M/L for rendering 15mm thick in CM 1:6 on fair faces of brick work or concrete surfaces finished fair and even complete all as specified and as directed.
M & L for applying two coats of cement base paint over a coat of alkali resistant primer on newly plastered wall surfaces including preparation complete all as specified and as directed.
Removing excavated material n exc. 50 m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cms in soft /loose soil complete all as specified and as directed.
M & L for 50 mm thick sand filling under floors or in foundations including watering and consolidation complete all as specified and directed.
M&L for 80 mm thick Machine pressed precast concrete interlocking paver block of any shape and size confirming to IS - 15658-2006 of M-35 Grade with with grey cement and pigment,tiles of any colour complete all as specified and as directed.
Roughening surfaces of old concrete floor by picking incl. taking down existing detoriated / decayedPCC tiles or any type of loose surface, scraping with scraper, chiseling, scraping of surface with wire brush or any other method, sweeping clean & washing down with water to remove dust etc. and removing the scraped materials outside the MD land complete all as specified and as directed .
M&L for 25 mm thick cement concrete Type B-0 1:2:4 (Using 12.5 mm graded stone aggregate ) as in sub base to floors to receive rough finish complete all as specified and as directed .
M&L for Chequered cement concre tiles 20 cm x20 cm x 25 mm thick, set, jointed and pointed with grey cement and pigment over and including 15mm thick screed bedding layer in CM 1:6 set and jointed in neat cement slurry complete all as specified and as directed
M & L for PCC 1:2:4 type B-0 (using 12.5 mm graded aggregatete) as in roof kerbs or mud stops, rounded or chamfered on edges complete all as specified and as directed.
Demolition of reinforced cement concrete of any description and in any position complete all as specified and directed.
M&L for PCC (1:4:8) type D2 (using 40mm graded stone aggregate) as in walls or retaining walls,any thickness, size or shape including pilasters,buttresses, columns, pillars,boundary pillars and posts (including caps and bases) →as in foundation filling and mass concrete, complete all as specified and directed.
M&L for RCC -M-25 (Design mix) using 20mm graded stone aggregate as in Columns, pillars, piers,posts and struts complete all as specified and as directed.
M&L for PCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) in lintels upto 1.5 clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers ,apex stones, bed plates, water troughs and the like including use of formwork (straight or curved) ,including weathering, slightly rounded or chamfered angles and throating, all as specified and as directed (Note:-reinforcement where provided shall be measured and paid seprately)
Formwork to sides of pillars, posts, struts, piers, columns and stanchions, Square,Rectangular,polygonal complete all as specified and directed.
Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed.
M&L for Brickwork with fly ash bricks, old size straight or curved on plan exc 6m mean radius, built in cement mortar (1:6) complete all as specified and directed.
M&L for 15mm thick rendering on concrete/brick surfaces in CM 1:4 with water proofing compound finished even and smooth without using extra cement complete all as specified and as directed. (Note:- WPC measured and paid separately)
M&L for TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality conforming,complete all specified and directed.
M&L for Mild steel TMT bars 5 mm and over upto and including 10 mm dia in stirrups,spaces and binders cut to length bent to shape required including cranking bending spirally for hooping for columns hooking ends and binding with and including mild steel wire ( annealed) not less than 0.9 mm dia complete all as specified and directed.
S&F Mild steel angle iron as in posts and struts including embeding in concrete , notching for wire , cutting tops to shape,drilling holes, bolting etc., conforming to Fe 290-0 or Fe 165-0 complete all as specified & directed .
S&F Galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured) complete all as specified and as directed.
S&F Punched tape concertina coil made out of low carbon strip duly electro galvanised , dia of wire not less than 2.59mm, dia of coil 600mm (appx) when closed with all necessary clips and RBT wire to connect with angle iron or brackets etc with all accessories. (6.00 RM coil weighing not less than 15 kg streched to not more than 10.00 RM having not more than 51 circles /turns ) complete all as specified and directed.
M&L for Hardcore broken stone or boulders of gauge n exc. 63mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and as directed.
Supply only integral water proofing compound complete all as specified and as directed.
M&L for RCC M-15 ( Nominal mix) Type B1 1:2:4 using 20mm grades stone aggregate as in foundation including raft footings, foundation beams, plinth beams, bases of columns and the like complete all as specified and as directed.
M & L for RCC M-15 (Nominal Mix) Type B1 1:2:4 using 20mm graded aggregate in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and as directed.
M & L for RCC (Nominal mix) Type B1 1:2:4 using 20mm graded stone aggregate as in coloumn,pillars,piers, posts and struts complete all as specified and as directed.
Cutting chases in brick walls, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth complete all as specified and as directed.
M&L for Brickwork with fly ash bricks or brick tiles in half brick walls built in cement mortar 1:4 complete all as specified and as directed.
M&L for 10mm thick rendering in CM 1:6 on brick or concrete surfaces finished even and smooth without using extra cement complete all specified and as directed.
M&L for Preparing Newly Plastered Surfaces of internal wall and applying two Coats of oil emulsion distemper over 3 mm thick wall care putty on wall plastered surface complete all as specified and as directed.
Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter rough finish complete all as specified and as directed.
Formwork to sides and soffits of floor or roof beams, beam haunchings, girders,bressum-mers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floor and beam etc complete all as specified and as directed.
S&F steel windows or ventilators, fixed type with glazing bars complete all as specified and as directed.
M&L for 50 mm thick PCC 1:3:6 type C-1 using 20mm graded stone aggregate as in plinth protection finishing even & fair without using extra cement laid in bays with construction, 6mm thick joints should be filled with bitumen mastic filling comprising of one part of heated bitumen 80/100 gde and three part of sand ( all by weight) complete all as specified and as directed.
M&L for glazed ceramic coloured tiles of size 450 x 300 x 6 to 7 mm,450x350 or 350x250 6 to 7mm thick on vertical surface such as skirting/dado etc. ,set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tile with & including rendering 10 mm thick in cement mortar 1:4 finished rough to fix tiles complete all as specified and directed.
M & L for PCC 1:3:6 type C-2 ( using 40mm graded stone aggregate ) in fdn filling and mass concrete complete all as specified and as directed.
S & F mild steel bolts exc 20 & n exc 25mm dia, length exc 30cm made with hexagonal or square head one end and screwed the other, or screwed both ends; each screwed end to be fitted with washers and one hexagonal or square nut. complete all as specified and as directed.
M & L for Machine cut Kota stone slab flooring 20-25 mm thick over and including 20mm thick screed bed in CM 1:6 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete all as specified and as directed.
M & L for Kota stone slab 15-20 mm thick in riser of steps, skirting, dado and pillar laid over over 10mm thick rendering in cement mortar 1:4 as backing to fix the tiles and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete all as specified and as directed.
M&L for 32 mm bore low density polythelene pipes (LDPE) with fittings of pressure rating 6 Kgf / Sqcm fixed to walls or in floors etc complete all as specified and as directed.
S&F grating doom 100mm dia PTMT (Min weight 25 grms) complete all as specified and as directed.
S& F 2000 ltrs rotational moulded polythine water storage tanks( cylinder vertical with closed top) hoisted and fixed in position including ball brass valves,high pressure with polythene float and flynut complete screw for iron pipe or brass ferrule all as specified in SSR Part-I complete all as specified and as directed.
S & F for 25mm bore ball valve high pressure PTMT with epoxy coated aluminium rod & high densitypolythene float ball and fly nut 25mm-455gms)screwed for iron pipe complete all as specified and as directed.
S&F for 20mm dia gun metal,globe or gate valve with iron wheel head screwed both ends for iron pipe and fixed complete all as specified and as directed.
S&F for 25mm dia gun metal,globe or gate valve with iron wheel head screwed both ends for iron pipe and fixed complete all as specified and as directed.
M&L for 75mm dia PTMT multi floor trap plain with grating including jointing with solvent cement complete all as specified and as directed.
S&F for 110 mm dia PVC (SWR ) pipes Single socketed in any length with rubber rings jonits fixed to walls complete all as specified and as directed.
S&F for 110 mm dia PVC (SWR ) bends any radius with access door complete all as specified and as directed.
S & F stack clamps out of 50mm x 5mm flat iron stays, including bolts and nuts and securing ends of stays to wall or roof for 100 mm bore complete all as specified and as directed.
S&F 25mm bore GI tubing medium grade pipe complete with all fittings and fixed complete to wall or laid in floors Complete all as specified and directed.
S&F 20mm bore GI tubing medium grade pipe complete with all fittings and fixed complete to wall or laid in floors Complete all as specified and directed.
S&F 15mm bore GI tubing medium grade pipe complete with all fittings and fixed complete to wall or laid in floors Complete all as specified and directed.
S& F for 15 mm bore bib tap cast copper alloy, chromium plated, long body fancy type with capstan headed, screwed down, screwed for iron pipe complete all as specified and as directed.
S&F framed work such as grills, gratings etc with ends of bars shouldered and or reiverted or forged into spikes, framed guard bars and similar work conferming to Fe 410-0 or Fe 310-0 complete all as specified and as directed.
S & F Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering,running rails and guides) and hanging; also fastening and fixing complete Fe 410 -W (Gde-E- 250)quality complete all as specified and as directed.
S & F for Mild steel 1mm Thick, plain, blacksheet in wall cladding,steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required complete all as specified and as directed.
S&F for Factory made steel window with side hung shutters including projecting type hinges,steel handle and steel peg stay complete with glazing bars, dovetailed or welded complete all as specified and as directed.
Description all as per above Srl item No 77 but without glazing bars.
S&F for 3mm thick Sheet glass,ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane complete all as specified and as directed.
S&F in stainless steel wire cloth 0.50 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with stainless steel wire staple/ wooden beads complete all as specified.
S&F for Stainless steel sink with draining board, made out of 1.00mm thick sheet for kitchen or laboratory with plug, washers waste pipe, cast iron cantilever brackets, connecting union overall Size 915mmx460mm with bowl size 410mm x330mm x 160mm complete all as specified and as directed..
M&L of Sub main wiring with two single core PVC Insulated cable two run of size 4 Sqmm multi-strand copper conductor FRLSH cable 1100 volts grade drawing in and including PVC conduit, medium grade not less than 20 mm dia with all conduit accessories and one run of 4.0 Sqmm multi-strand copper conductor FRLSH cable as continuous earth wire including making good disturbed surface to match existing complete all as specified & directed. Note : - Two run of 4 Sqmm & one run of 4.0 Sqmm cable shall be measured as one unit run.
M&L of Sub main wiring with two single core PVC Insulated cable two run of size 6.0 Sqmm multi-strand copper conductor FRLSH cable 1100 volts grade drawing in and including PVC conduit, medium grade not less than 25 mm dia with all conduit accessories and one run of 6.0 Sqmm multi-strand copper conductor FRLSH cable as continuous earth wire complete all as specified and directed. Note : - Two run of 6 Sqmm & one run of 6 Sqmm cable shall be measured as one unit run.
M&L of Sub main wiring with two single core PVC Insulated cable two run of size 10.0 Sqmm multi-strand copper conductor FRLSH cable 1100 volts grade drawing in and including PVC conduit, medium grade not less than 25 mm dia with all conduit accessories and one run of 10.0 Sqmm multi-strand copper conductor FRLSH cable as continuous earth wire complete all as specified and directed. Note : - Two run of 10 Sqmm & one run of 10 Sqmm cable shall be measured as one unit run.
Material & Labour for point wiring with three layer PVC Insulated 1.5 Sqmm multi-strand copper conductor FRLSH cable 1100 Volts grade drawn into and concealed PVC conduits medium grade not less than 20mm( ISI marked) including all fitting and fixing accessories including 1.25 mm thick sunken pressed steel terminal boxes/Modular metal flush box duly painted with two coats of anti-corrosive paint outside and two coats of aluminium paint inside with and including 3mm thick hylam brand laminated white bakelite sheet cover for mounting switches, sockets, fan regulators fixed with CP screws with cup wahsers and PVC insulated 1.5 Sqmm multi-strand copper conductor cable as earth wire and making good the disturbed surfaces with cement sand mortar 1:3 to match with the existing surfaces complete all as specified and as directed for One light/fan/bell Point controlled by one switch.
Description all as per above Srl Item No 85 but for one socket point 5 Amp controlled by one switch on same board.
Description all as per above Srl Item No 85 but for one socket point 5 Amp controlled by one switch on Independent board.
Description same all as per item No 85 here in above but with 1100 Volts grade copper stranded conductor FRLSH cable of size 2.5 Sqmm main & with 2.5 Sqmm earth multi-strand copper conductor cable as earth wire for 3 pin switch socket outlet 15 Amp on Independent board complete all as specified and as directed.
S&F for frame plate for modular switch 1 module including screws and washers etc model/make as per existing in site complete all as specified and as directed.
S&F for frame plate for modular switch 2 module including screws and washers etc model/make as per existing in site complete all as specified and as directed.
S&F for frame plate for modular switch 3 module including screws and washers etc model/make as per existing in site complete all as specified and as directed.
S&F for frame plate for modular switch 4 module including screws and washers etc model/make as per existing in site complete all as specified and as directed.
S&F for frame plate for modular switch 6 module including screws and washers etc model/make as per existing in site complete all as specified and as directed.
S&F for frame plate for modular switch 8 module including screws and washers etc model/make as per existing in site complete all as specified and as directed.
S&F for MS Housing box 1/2 module suitable for modular switch as per existing switch box and making good to the disturb surface complete all as specified and as directed.
S&F for MS Housing box 3 module suitable for modular switch as per existing switch box and making good to the disturb surface complete all as specified and as directed.
S&F for MS Housing box 4/5 module suitable for modular switch as per existing switch box and making good to the disturb surface complete all as specified and as directed.
S&F for MS Housing box 6/8 module suitable for modular switch as per existing switch box and making good to the disturb surface complete all as specified and as directed.
S&F for modular switch 6-10 Amps one module 230 volts AC as per existing model/make complete all as specified and as directed
S&F for modular switch 16 Amps one module 230 volts AC as per existing model/make complete all as specified and as directed
S&F for modular socket, 6A -2/3 pin combined 2 module, 230 volts AC as per existing model/make complete all as specified and as directed.
S&F for modular socket, 6/16A -2/3 pin combined 2 module, 230 volts AC as per existing model/make complete all as specified and as directed .
Supply & Fixing sheet metal enclosure MCB DB double door [Acrylic], single pole and neutral, 240 volts, 8 way with 200 Amp, 10 KA breaking capacity rated bus bar with blanking plate wherever required and IP-43 degree protection complete all as specified and as directed.
Supply & Fixing sheet metal enclosure MCB DB double door [Acrylic], single pole and neutral, 240 volts, 4 way with 200 Amp, 10 KA breaking capacity rated bus bar with blanking plate wherever required and IP-43 degree protection complete all as specified and as directed.
S&F sheet metal enclosure MCB DB double door [Acrylic], Triple pole and neutral, 440 volts, 4 way with 200 Amp, 10 KA breaking capacity rated copper bus bar with blanking plate wherever required and IP-43 degree protection complete all as specified and as directed.
S&F MCB Triple Pole and Neutral 63 Amps,415 V ,10KA breaking capacity complete all as specified and as directed.
S&F MCB Single Pole and Neutral 240Volt, 40 Amps,10KA breaking capacity complete all as specified & directed.Make: Legrand cat no :4086 18 or eq in SEIMENS /GE
S&F in replacement MCB Single Pole and Neutral 240Volt, 63 Amps,10KA breaking capacity complete all as specified & directed.Make:Legrand / Seimens/GE
S&F MCB Single Pole 240Volt, upto 40Amps,10KA breaking capacity complete all as specified and as directed..
Supply & Fixing single pole and netural sheet metal enclosure with a two pin and earth plug and socket complete with 01 number single pole MCB 20 Amps complete all as specified and as directed.
M& L for Complete removal of existing treatment Washing, rubbing down and stopping of distempered and painted surfaces plastered and other surfaces, applying two coats of oil bound distemper over and including 2mm thick wall care putty on wall over a coat of alkali resistant primer on wall including preparation complete all as specified and as directed.
Supply, laying or fixing or passing through pipe commissioning and testing of PVC / XLPE insulated, armoured heavy duty, electric cable of size 35 Sqmm 3.5 core with aluminium conductor, 1100 volts grade including suitable size lugs complete all as specified and as directed. Note:- Excavation & earth work, sand cushioning, bricks protection & GI pipe where required shall be measured & paid separately under relevant items.
Supply, laying or fixing or passing through pipe commissioning and testing of PVC / XLPE insulated, armoured heavy duty, electric cable of size 120 Sqmm 3.5 core with aluminium conductor, 1100 volts grade including suitable size lugs complete all as specified and as directed. Note:- Excavation & earth work, sand cushioning, bricks protection & GI pipe where required shall be measured & paid separately under relevant items.
M&L for cutting of roads /trenchless technology method complete all as specified and as directed.
M&L for Sand cushioning to under ground cable in trenches/existing cable trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep after laying and stretching the cable complete all as specified and as directed. Note: Punned thickness shall be measured and paid.
Supply and laying Brick covering with width equal to length of brick as mechanical protection to cable with well burnt sub class ‘B’ bricks laid dry flat complete all as specified and as directed.
Disconnecting, dismantling of existing old unserviceable LT Panel/Feeder pillar box and Design, supply, erection, commissioning and testing of outdoor type LT Panel, platform mounted, suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos stepped type main copper bus bars of 400 Amps, looping & branch connection system shall be made with suitable rating copper bus bar having sleeves of colour coded .The chamber shall be painted with powder coated paint (Shade : RAL-7032) after 9 tank pre-treatment of surfaces. The LT Panel shall be provided with suitable Neoprene rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-66 and general construction conforming to IS : 13947. The LT Panel shall be made out of 3.15mm thick CRCA mild steel sheet and 3.00mm thick gland plate , front door (02 layers) and rear Door (01 layer) opening facility and 4 side slanting canopy type roof on top and mild steel channel (75 MC) base frame at bottom. All incoming MCCBs shall be marked with location and rating of MCCBs. The Feeder Pillar shall be provided with ventilation facility in the form of louvers for better heat dissipation in and including dismantling of old unserviceable LT Panel complere and including the followings :
CONTROL WIRING : All control wirings shall have to be carried out with 1100 volts rated FR grade PVC insulated multi-flexible type copper wire of cross sectional area 1.50Sqmm and shall be properly bunched, tied and dressed, ferrule marked for proper identification and crimped with suitable size and type of tinned copper lugs and shall be wrapped with PVC spring type tube near the door hinges. CABLE ALLEY- Cable alley shall be provided in both side of the panel of suitable space for all incoming and outgoing cables. Cable terminals shall be provided for conecting of all incoming and outgoing cables, INCOMING :- MCCB 250 Amps, 4 pole, 415 volts, 50 kA, 50 Hz, microprocessor based, electronic release. OUTGOING : (a) MCCB 160 Amps, 4 pole, 415 volts, 36 KA, 50 Hz, adjustable thermal & Adjustable magnetic, Ics = 100%Icu, - 01 Nos (b) MCCB 100 Amps, 4 pole, 415 volts, 25 KA, 50 Hz,adjustable thermal & Adjustable magnetic, Ics = 100%Icu, - 02 Nos
(c) MCCB 63 Amps, 4 pole, 415 volts, 16 KA, 50 Hz, fixed thermal & fixed magnetic, Ics = 100%Icu, - 02 Nos (d) Digital volt meter 96mm x 96mm suitable to read 0 to 500 volts, accuracy class 1% - 01 Nos. (e) Digital Ammeter 96mm x 96mm suitable to read 0 to 630 Amps, accuracy class 1% - 01 Nos. (f) Current transformer (CT) of rating 630/5, tape wound, rated burden 5 VA - 03 Nos (g) LED indicator lamps complete with integral circuit and cluster LED, suitable to operate in 230-240 Volts AC supply - 1 set of 03 Nos (Red - 01, Yellow- 01, Blue - 01) (h) Control fuse holder, made of bakellite, 16 Amps rating, stud type, pannel door mounting complete with 01 No 02 Amps HRC fuse of suitable type- 03 Nos. (j) Copper bus bar 20mm wide,5mm thick, of suitable length duly mounted on FRP bus bar insulators and marked with standard colour coded sleeves / tapes for all outgoing MCCBs - 04 Nos.
(k) LED Pilot Lamp of following colours : (i) RED - 01 No, YELLOW - 01 No, BLUE - 01 No. (l) 02 Nos.Danger Notice Plate duly written in Signal Red colour on aluminium plate in English and Hindi language and of size not less than 150mmx100mm shall be fixed on both front & rear door of the bus bar chamber. (m) Power contactor four pole with coil voltage 230 volt of capacity 25 Amps 50 cycles - 01 Nos (n) Time switch microrex analog time switch -01 Nos (o) Pannel box made up of CRCA mild steel 3.15mm thick, duly powder coated with busbar and internal wiring all as per CPRI approved (The panel shall not be less than 2.5 Sqm front area) Note : Panel will be manufactured by CPRI approved firm as indicated above. The contractor shall submit drawing of the panels to Engr-in-charge before procurementof LT panel for approval alongwith CPRI approval. Foundation will prepared as per instruction and rate of fondation deemed to be included in the quoted rates.
S & F for Switch Piano type single pole 5 amp, 230 Volts complete all as specified and as directed.
M/L for switch socket combination multipin 5 and 16 Amps AC 230 volts flush type complete all as specified and as directed .
S & F for Ceiling rose surface bakelite 65 mm x50 mm three terminal AC 230 volts flush type complete all as specified and as directed
S & F for Smart bright Batten Series, LED luminaire using LEDs 20 watt 110 LM/watt with diffuser which ensures uniform distribution and comfort batten series features latest LEDs and delivers consistent light output, stable color start Extruded Aluminum housing, Energy efficient, Flicker free start Inbuilt driver unit Suitable for wall and ceiling mounting using brackets complete all as specified and as directed.
Supply & fix for LED Bldg Security Light Luminaire 25 watt 2500 or more lumen warm white, surge protection device upto 4 KV, IP 65 or more, IK07 or more, potted driver suitable for 180 to 270 V 50 Hz, light engine driver base pole adapter, powder coated pressure die cast aluminium with heat resistant toughened glass with lens type. GI 40 mm dia medium Grade not less than with 1.2m long in any shape with 2 nos of pole fitting clamps made out MS flat, nuts and bolts and painting with aluminium paint complete all as specified and as directed.
Supply & Fixing sheet metal enclosure MCB DB double door [Acrylic], single pole and neutral, 240 volts, 4 way with 200 Amp, 10 KA breaking capacity rated bus bar with blanking plate wherever required and IP-43 degree protection complete all as specified & as directed.
S & F for MCB Single pole and neutral 240 Volts 20 Amps B series complete all as specified and as directed.
S & F for MCB Single pole and neutral rated capacity 40 Amps, 240 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed.
Supply , laying and testsilng cable XLPE insulated , screened, PVC bedded , galvanized , steel strip or wire armoured, electric power cables ( Heavy duty ) 1100 volts grade with stranded aluminium conductor of size 2 core 16 Sqmm complete all as specified and as directed.
Material & Labour for earthing complete with galvanised steel earth plate electrode of size 600mm x 600mm x 6mm thick burried directly in ground (Earth pit not less than 2.25 m deep below the normal ground level with top edge of earth plate not less than 1.5 m below normal ground level) connected to galvanised earth wire 4 mm dia as earth wire or earthing lead by means of bolts, nuts, check nuts and washers of GI or steel complete as shown in Electrical Plate No. 3 of SSR-2009 (Part-I) including charcoal dust, common salt, 20mm bore GI medium grade watering pipe, MS Sheet funnel with wire mesh, including 15mm dia GI pipe light grade for protection of GI earth wire including PCC pit 1:2:4 type B-1 using 20mm graded crushed stone aggregate with angle iron 40X40X5mm frame 60mm thick RCC cover with 8mm # TMT bars @ 100 mm centre to centre both ways i.e. horizontal and vertical complete all as directed by Engineer-in-charge and testing for required value complete. Note:- If earth resistance of earthing is not found satisfactory it will be redone by the contractor without any extra cost to Govt.
S & F for Socket outlet 3 pin, 5 Amps and AC 230 volts flush type complete all as specified and as directed.
S & F for Smart bright Batten Series, LED luminaire using LEDs 22 watt 110 LM/watt with diffuser which ensures uniform distribution and comfort batten series features latest LEDs and delivers consistent light output, stable color start Extruded Aluminum housing, Energy efficient, Flicker free start Inbuilt driver unit Suitable for wall and ceiling mounting using brackets complete all as specified and as directed.
Earthing complete with galvanised steel earth plate electrode 60 cm x60 cm x 6 mm thick buried directly in ground ,(Earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level ,connected to and including galvanised iron earth wire 4 mm dia by means of nut, bolts, check nuts and washers of galvanised iron or steel complete all as specified and directed including testing on completion including the material and labour of the following : - (a) Excavation and earth work for drilling hole for electrode in any type of Soil. -1, reinforced with welded steel wire fabric weighing not less than1.87 Kg/ Sq meter. (c) Funnel with watering pipe of GI 20 mm nominal bore light grade and lugs etc complete all as specified and directed (d) 15 mm nominal bore medium grade GI protection pipe 5 meter long for protection of earthing lead complete all as specified and directed. (e) Requisite quantity of common salt and charcoal. (f) Testing of earthing.
AROOP ENTERPRISES (BID ID -3100205)
HAFEEZ CONSTRUCTION (BID ID -3100413)
a k builders (BID ID -3115406)
SHRI KRISHNA CONSTRUCTIONS (BID ID -3100577)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .