| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.7 LAccepted-AOC PLOT NO 17 GF PRATAP NAGAR NEW DELHI 110064 | WEST | DELHI | 110064 | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹29.1 L+₹4.2 L (16.8%)Rejected-Finance 1ST FLOOR H NO 165 GALI NO 16 S B S COLONY KARAWAL NAGAR DELHI EAST DELHI DELHI 110094 | NORTH EAST DELHI | DELHI | 110094 | L2 | Rejected-Finance Being other than lowest | |
| 3 | L3₹30.2 L+₹5.3 L (21.3%)Rejected-Finance 35 MODEL TOWN GT ROAD JANDIALA GURU AMRITSAR | AMRITSAR | AMRITSAR | PUNJAB | L3 | Rejected-Finance Being other than lowest | |
| 4 | L4₹30.4 L+₹5.6 L (22.3%)Rejected-Finance 08 PINK ENCLAVE MAHESH NAGAR BALAJI VIHAR GOPALPURA JAIPUR RAJASTHAN 302015 INDIA | JAIPUR | RAJASTHAN | 302015 | L4 | Rejected-Finance Being other than lowest | |
| 5 | L5₹32.2 L+₹7.4 L (29.6%)Rejected-Finance 1 206 SHOP NO 71 MANDIR MARKET SADAR BAZAR DELHI CANTT 110010 | DELHI CANTT | NEW DELHI | DELHI | 110010 | L5 | Rejected-Finance Being other than lowest |
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
31 Dec 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (EAST) DELHI CANTT-10
GE (EAST) DELHI CANTT-10
INTERNAL PERIODICAL SERVICES INCL CERTAIN B/R WKS AT KABUL LINE, FAFA AND OTM ACCN IN THE AOR OF AGE BR-II UNDER GE (EAST) DELHI CANTT-10
2022_MES_568246_1
GE/DE-73/2022-23
Open Tender
Civil Works
Item Rate
180 days
GE (EAST) DELHI CANTT-10
Class D cat a (i)
8 documents required · 8 mandatory
₹500
Yes
GE (EAST) DELHI CANTT-10
₹1 L
Yes
8 Feb 2023
9 Dec 2022
2 Jan 2023
9 Dec 2022
31 Dec 2022
24 Dec 2022
Amount
M&L Preparation of old plastered surfaces of walls, applying two coats of Oil bound distemper over one coat of primer and wall care putty 1mm thick incl removal of existing treatment by scrapping down complete all as specified and directed.
All same as per srl item No 1 here-in-before but on ceiling.
M&L one coat of synthetic enamel paint on old wooden painted surfaces including preparation of any description not otherwise descriped over 10 cm width or grith complete all as specified by Engr-in -Charge.
M&L one coat of synthetic enamel paint on old steel painted surfaces including preparation of any description not otherwise described over 10 cm width or grith complete all as specified and directed by Engr-in -Charge.
M & L two coats of cement base paint on old wall surface incl preperation with sand papering and filling pot holes with wall care putty complete removal of existing treatment..
M&L 10-12mm thick polymer modified readymix cement base plaster as per manufacturers instructions on fair/ unfair faces of brick work or concrete surfaces including taking down plaster finishing even & smooth complete all as specified & directed. (Make:Ultratech or equivalent)
M&L Preparation of new plastered surfaces of walls and applying two coats of Oil bound distember over one coat of primer and wall care putty 1 mm thick complete all as specified and directed.
All same as per srl item No 7 here-in-before but on ceiling.
M & L two coats of cement base paint on old wall surface incl preperation with cement primer and 1mm thick wall care putty complete after removal of existing treatment.
M&L for preparation of old decorated external wall surface by complete removal of existing treatement by mechanised sander of Berger paints or equivalent makes viz Xpress sanding machine having suction vaccum bag or by manual scrapping tools where mechincal removeal is not possible and applying a layer of 2 mm thick wall care putty, again sand papering thus making surface smooth and applying two coat of wheather proofing exterior acrylic emulsion paint premium quality over a coat of primer on wall surfaces complete as per manufacturer instructions all as specified (Make:- BERGER (WEATHER COAT LONG LIFE 10), ASIAN (APEX ULTIMA), NEROLAC (EXCEL MICA MARBLE), DULEX (WEATHER SHIELD MAX)
Hacking out old brocken glass (any thickness , size , quality or description ) from wooden/metal frames or stone, concrete or brick surrounds , glazed with putty or fixed with beads
S&F 4mm thick Sheet glass, ordinary quality and glazing with oil putty/wooden beading in square not exc 0.5 sq.m. in each pane complete all as specified and directed.
S&F 4mm thick Figured glass, pinhead type with oil putty in squares n exc 0.5 Sqm each pan complete all as specified.
S&F in repair stainless steel wire cloth, 0.36 mm nominal dia. of wire and average width of aperture 1.40 mm and fixed with tinned tacks, or stainless steel wire staples complete all as specified and directed. Note- Welder with welding machine reqd to fix wiremesh in old steel windows
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the permises complete all as specified and directed.
M&L Vitrified Ceramic Coloured tiles 8 to 10 mm thick (square/rectangular) (Double charge ) polished, area of each tiles n exceeding 0.36 Sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tiles over and including 15 mm thick screed bed in CM 1:6 complete all as specified.
M&L Non skid ceramic coloured floor tiles 400mm x 400mm x 7-8mm thick as in floors, set and jointed in neat cement slurry and pointed in white cement with pigments to match over and including 15 mm thick bedding layer in cement mortar 1:6, complete all as specified and as directed.
All as per description of Srl items No. 16 here-in-before but in vertical surfaces of skirtings set and joint in neat cement slury and pointed in white or colour cement to match laid over 10 mm thick rendering in cement mortar 1:4, complete all as specified and as directed.
M&L for glazed coloured ceremic tiles sizes 450x300x 7mm thk tiles (double charge) on vertical surfaces , such as skirting/dado over and incl 10 mm rendering in cement mortar 1:4 set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of the tiles complete all as specified and directed.
Dismantling of Cast Iron pipe up to 100 mm bore complete all as specified and directed.
S & F Sand cast iron soil waste and vent pipes 100mm dia, in any length, with cement joints, laid in floors, fixed to walls/floors and conforming to IS-1729, complete all as specified and as directed.
S&F Sand cast iron soil waste and vent pipes75 mm dia, in any length, with cement joints, laid in floors, fixed to walls/floors with CI/MS clamps and conforming to IS-1729, complete all as specified and as directed.
S&F CI bend for 100mm bore any radius, diminishing pieces or tapers (larger bore measured), fixed to walls, complete all as specified and as directed.
S&F CI bend for 75mm bore any radius, diminishing pieces or tapers (larger bore measured), fixed to walls, complete all as specified and as directed.
M&L PVC (SWR) pipe in repair 110mm bore single socketed in any length with rubber ring joints incl clamps complete all as specified and directed by Engineer- In- charge.
M & L PVC bend in repair 110mm bore any radius complete all as specified and directed by Engineer- In- charge.
S&F 75mm bore PVC (SWR) pipes in repair single socketed, in any length to wall including mild steel stack clamps fixed in cement concrete 1:2:4 blocks with rubber ring joints fixed to walls complete all as specified and directed.
S&F 75 mm bore PVC (SWR) bends with rubber ring joints fixed to walls in repair complete all as specified and directed.
M&L in repair CI fittings such as Tee,bend,branch piece,floor trap etc upto 100mm bore (waste water/rain water/soil pipe) where ever required to stop leakage including testing of leakage upto eight storied building complete all as specified and directed. Note :- The necessary steel scaffolding upto eight storeyed whereever required to complete the job shall be provided by the contractor with all safety equipments and the rate for scaffolding & safty equipments shall be deemed to be included in the quotted rates by the contractor and nothing extra shall be paid on this account
M&L in repair PVC/UPVC fittings such as Tee,bend,branch piece,floor trap etc upto 100mm bore (waste water/rain water/soil pipe) where ever required to stop leakage including testing of leakage upto eight storied building complete all as specified and directed. Note :- The necessary steel scaffolding upto eight storeyed whereever required to complete the job shall be provided by the contractor with all safety equipments and the rate for scaffolding & safty equipments shall be deemed to be included in the quotted rates by the contractor and nothing extra shall be paid on this account
R. S. Associates
STAR CONSTRUCTION CO
Simran construction Company
A R construction
HANUMAN BUILDERS
S GOURAV PRAKASH ENTERPRISES
POONAM ENTERPRISES
M/S MSD & Associate
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .