| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.9 LAccepted-AOC 306 BAKSHI HOUSE 40 41 NEHRU PLACE NEW DELHI 110019 DELHI | SOUTH EAST | DELHI | 110019 | L1 | Accepted-AOC Quoted low | |
| 2 | L2₹8.9 L+₹1,830 (0.21%)Rejected-AOC E 2 216 GROUND FLOOR SHIV RAM PARK NEAR LUCKY GARDEN NANGLOI NEW DELHI 110041 | WEST DELHI | DELHI | 110041 | L2 | Rejected-AOC Quoted high than L1 | |
| 3 | L3₹9.5 L+₹60,863 (6.86%)Rejected-AOC 201 PLOT NO 32 SHALAKA BLDG TPS II JUHU ROAD SANTACRUZ WEST MUMBAI SUBURBAN MAHARASHTRA 400054 | MUMBAI SUBURBAN | MAHARASHTRA | 400054 | L3 | Rejected-AOC Quoted high than L2 | |
| 4 | L4₹9.7 L+₹79,040 (8.91%)Rejected-AOC | L4 | Rejected-AOC Quoted high | |
| 5 | Rejected-Technical | - | Rejected-Technical Affidavits submitted are not as per NIT requirement( no name of work and also not notarised) |
Tender Value
₹10.3 L
EMD Value
₹20,566
Closing Date
28 Dec 2019, 6:00 pmClosed
Ram Mohan S,Asst.Gen.Manager(E-E).
Ram Mohan S Asst.Gen.Manager(E-E), AAI, Mangaluru Intll Airport
Replacement of ACs, water coolers and water dispensers at various location. SH- Replacement of ACs at various locations in Mangaluru International Airport
2019_AAI_37996_1
AAI/ML/ENGG (E)/AGM (E)/ NIT-04/2019-20
Open Tender
Electrical Works
Item Rate
120 days
Mangaluru International Airport
As per NIT
10 documents required · 10 mandatory
₹1,120
Airports Authority Of India
₹20,566
13 Feb 2020
16 Dec 2019
3 Jan 2020
16 Dec 2019
28 Dec 2019
16 Dec 2019
16 Dec 2019 - 26 Dec 2019
Amount
Supply and installation of 4 TR Cassette type air conditioning unit consiting of non-ductable single phase room unit (evoporator) of ceiling mounting type having inbuilt drain pump system, cordless remote control unit and one number of out door unit (Condensor) comprising hermatically sealed scroll/rotary compressor suitable for operation on 3 phase 415V 50Hz AC supply including fixing the outdoor unit on a raised 5mm thick angle iron stand/plateform of height 300mm, fixing to the ground, painting the angle iron stand with enamel paint, fixing of room unit (evaporator) on ceiling using suitable size angle iron channels/anchor bolting with threaded rod including welding etc as required on ceiling, providing insulation to indoor unit as required standards of OEM, making suitable opening on the wall and plastering and finishing the same after taking out copper pipes, drain pipe and electrical wire to connect between outdoor and indoor, making all inter connection between evoporator and condensor unit, first charging of refrigerant, testing and commissioning the whole system etc. complete as required. The coil inside evaporator and condensor unit should be copper only.
Supply and fixing of following items for inter connection between evaporator and condenser unit of 4 TR cassette type A/c unit, supporting/fixing of pipe, testing and commissioning along with the unit complete as required a. Copper liquid line as per design of OEM embedded in suitable dia closed cell elastomeric nitrile rubber insulation tubes. b. Copper suction line as per design of OEM embedded in suitable dia closed cell elastomeric nitrile rubber insulation tubes c. 2.5 Sq.mm flexible copper conductor of required core including power and signal cable along with minimum one earthing with the same size wire (Between outdoor and indoor). d. Wrapping all items mentioned in "a" to "c" above fixed between evaporator and condenser unit using white wrapping tape.
Supply and installation of inverter type 5 star rated 2 TR high wall mounted split type air conditioning unit consisting of non-ductable single phase wall mounted room unit (evaporator) with cordless remote control and one number of outdoor condensing unit (condenser) comprising hermetically sealed rotary/scroll compressor suitable for operation on single phase 230 V 50Hz AC supply including fixing the outdoor unit on a raised 5mm thick angle iron stand/platform of height 300mm, fixing the same to the ground with concrete, painting the angle iron stand with enamel paint/ on outdoor bracket supplied by OEM to accommodate outdoor unit, fixing the same on wall, fixing of room unit (evaporator), providing and making all inter connection between evaporator and condenser unit up to a length of 3.0 (three) meter comprising of the following including making suitable opening on the wall, plastering and finishing the opening after taking out copper pipes, drain pipe and electrical wire, first charging of refrigerant, testing and commissioning the whole system etc. complete as required. The coil inside evaporator and condenser units should be copper only a. Copper liquid line as per design of OEM embedded in suitable dia closed cell elastomeric nitrile rubber insulation tubes b. Copper suction line as per design of OEM embedded in suitable dia closed cell elastomeric nitrile rubber insulation tubes c. 2.5 Sq.mm flexible copper conductor of required core including power and signal cable along with minimum one earthing with the same size wire (Between outdoor and indoor). d. Wrapping all items mentioned in "a" to "c" above fixed between evaporator and condenser unit using white wrapping tape.
Supply and fixing of following items for inter connection between evaporator and condenser unit of 2 TR high wall split type A/c unit, testing and commissioning complete as required (extra length if required) a. Copper liquid line as per design of OEM embedded in suitable dia closed cell elastomeric nitrile rubber insulation tubes b. Copper suction line as per design of OEM embedded in suitable dia closed cell elastomeric nitrile rubber insulation tubes c. 2.5 Sq.mm flexible copper conductor of required core including power and signal cable along with minimum one earthing with the same size wire (Between outdoor and indoor). d. Wrapping all items mentioned in "a" to "c" above fixed between evaporator and condenser unit using white wrapping tape.
Supply and installation of inverter type 5 star rated 1.5 TR high wall mounted split type air conditioning unit consisting of non-ductable single phase wall mounted room unit (evaporator) with cordless remote control and one number of outdoor condensing unit (condenser) comprising hermetically sealed rotary/scroll compressor suitable for operation on single phase 230 V 50Hz AC supply including fixing the outdoor unit on a raised 5mm thick angle iron stand/platform of height 300mm, fixing the same to the ground with concrete, painting the angle iron stand with enamel paint/ on outdoor bracket supplied by OEM to accommodate outdoor unit, fixing the same on wall, fixing of room unit (evaporator), providing and making all inter connection between evaporator and condenser unit up to a length of 3.0 (three) meter comprising of the following including making suitable opening on the wall, plastering and finishing the opening after taking out copper pipes, drain pipe and electrical wire, first charging of refrigerant, testing and commissioning the whole system etc. complete as required. The coil inside evaporator and condenser units should be copper only a. Copper liquid line as per design of OEM embedded in suitable dia closed cell elastomeric nitrile rubber insulation tubes. b. Copper suction line as per design of OEM embedded in suitable dia closed cell elastomeric nitrile rubber insulation tubes. c. 2.5 Sq.mm flexible copper conductor of required core including power and signal cable along with minimum one earthing with the same size wire (Between outdoor and indoor). d. Wrapping all items mentioned in "a" to "c" above fixed between evaporator and condenser unit using white wrapping tape.
Supply and fixing of following items for inter connection between evaporator and condenser unit of 1.5 TR high wall split type A/c unit, testing and commissioning complete as required (extra length if required) a. Supply and fixing of following items for inter connection between evaporator and condenser unit of 1.5 TR high wall split type A/c unit, testing and commissioning complete as required (extra length if required) b. Copper suction line as per design of OEM embedded in suitable dia closed cell elastomeric nitrile rubber insulation tubes. c.2.5 Sq.mm flexible copper conductor of required core including power and signal cable along with minimum one earthing with the same size wire (Between outdoor and indoor). d. Wrapping all items mentioned in "a" to "c" above fixed between evaporator and condenser unit using white wrapping tape.
Supply and fixing of ISI marked 20mm dia rigid PVC MMS drain pipe from evaporator of various AC units up to the ground level including providing suitable dia closed cell elastomeric nitrile rubber insulation on the pipe from indoor unit up to the end, fixing the pipe on to the wall using clamps etc complete as required.
Supplying and laying ISI marked FRLS PVC insulated copper conductor, single core cable of following size, fixing the cable along with exisitng copper pipes (between outdoor and indoor unit), wrapping inside along with copper pipes complete as required. 4 X 4 sq. mm + 2 X 4 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of ISI marked FRLS PVC insulated copper conductor, single core cable in surface/ recessed ISI marked medium class 20 mm PVC conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
Wiring for circuit/ submain wiring along with earth wire with the following sizes of ISI marked FRLS PVC insulated copper conductor, single core cable in surface/ recessed ISI marked medium class 25mm PVC conduit as required. 4 X 4 sq. mm + 2 X 4 sq. mm earth wire
Supplying and fixing four pole sheet steel enclosure on surface/ recess along with 32 amps 415 volts “C” curve four pole MCB confirms to relevant IS complete with connections, testing and commissioning etc. as required.
Dismantling the cassette/split type airconditioner units of various capacities along with all its associated accessories from the existing location, shifting to AAI store at Mangalore Airport, properly stacking in store as per the instructions of the Engineer -in - Charge etc complete as required.
Supply, Installing, Testing and Commissioning of Voltage Stabilizers suitable for 2 TR split AC units on wall including providing connections etc. as required. (V Guard VGB 500 or Equivlent)
Supplying and fixing of 110mm x 60mm casing & caping along with accessories in surface/recess/supporting from concrete ceiling using clamps/saddles/threaded rod and achore bolt and DIN rail channel support etc complete as required. ( for covering copper piping/drain line/electrical wiring etc from indoor to outdoor unit)
Supplying and fixing of 60mm x 60mm casing & caping along with accessories in surface/recess including cutting the wall and making good the same etc complete as required ( for covering drain pipe )
Supertech Engineers
DElite System Engineering (India) Pvt. Ltd.
guru electricals
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .