Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.0 LAccepted-AOC 10 1 GROUND FLOOR WEST GHOSH PARA JAGATDAL JAGATDAL JAGATDAL NORTH 24 PARGANAS WEST BENGAL 743125 | 24 PARAGANAS NORTH | WEST BENGAL | 743125 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹46.1 L+₹2.2 L (4.94%)Rejected-Finance | L2 | Rejected-Finance Being higher bid value | |
| 3 | L3₹46.9 L+₹3.0 L (6.72%)Rejected-Finance | L3 | Rejected-Finance Being higher bid value | |
| 4 | L4₹47.4 L+₹3.4 L (7.69%)Rejected-Finance 2 10 PANCHANANTALA ROAD KOLKATA 700 041 | KOLKATA | WEST BENGAL | 700041 | L4 | Rejected-Finance Being higher bid value | |
| 5 | L5₹48.0 L+₹4.0 L (9.16%)Rejected-Finance | L5 | Rejected-Finance Being higher bid value |
Tender Value
₹42 L
EMD Value
₹84,000
Closing Date
27 Jan 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE ALIPORE KOLKATA
NO 1 NATIONAL LIBRARY AVENUE, ALIPORE, KOLKATA 700027
8026/B/E8
2022_MES_499539_1
GE/ALP (8026B) OF KOLKATA 2021-22
Open Tender
Civil Works
Item Rate
210 days
GE ALIPORE KOLKATA
Class D and Category b (i)
8 documents required · 8 mandatory
₹500
GARRISON ENGINEER ALIPORE
₹84,000
Yes
28 Feb 2022
5 Jan 2022
28 Jan 2022
5 Jan 2022
27 Jan 2022
19 Jan 2022
60 days
Amount
Maintenance / servicing of APFC panel of capacity upto 700 KVA ,415 V -50/60 Hz -50kA for auto correction of power factor . complete checking of each capacitor bank, connector and MCB . Cleaning and servicing of all fixed and moving contacts replacement of accessories i.e lockable trip push button,auto /manual switch, indicator , volt meter, ammeter etc after disconneting the APFC for execution of work and re-fixing the same shall be with old serviceable spare parts in existing position and re-connecting all cables and testing on existing load complete all as specified and as directed. Make:- L&T. Note:- All new spare parts as required shall be measured and paid seperately.
Supply only capacitor metalized poly propylene heavy duty (MPP-H) for 3 phase ,440 V, 50 Hz System for permissible non- linear load 15% of 5 KVAR capacity. Make : L& T/Neptune/C&S
Supply and fixing for capacitor metalized poly propylene heavy duty (MPP-H) for 3 phase ,440 V, 50 Hz System for permissible non- linear load 15% of 10 KVAR capacity. Make : L&T/Neptune/C&S
Supply and fixing for capacitor metalized poly propylene heavy duty (MPP-H) for 3 phase ,440 V, 50 Hz System for permissible non- linear load 15% of 20 KVAR capacity. Make : L& T/Neptune/C&S
Supply and fixing for capacitor metalized poly propylene heavy duty (MPP-H) for 3 phase ,440 V, 50 Hz System for permissible non- linear load 15% of 25 KVAR capacity. Make : L& T/Neptune/C&S
Supply and fixing for MOC 25 contactor . Make :- L&T
Supply and fixing for LED indication lamps complete . Make : L & T
Supply and fixing for 10 sqmm Copper cable for panel connection. Make :- L&T/Havells/KEI
Supply and fixing for MCB 63 Amp three pole 10 KA 'C' Series. Make :- L&T, Havelles, Schiender.
Repair to AMF Panel 100 KVA Capacity DG Set by dismantling the following unserviceable items replacing the same by new one, rewiring all internal wiring and replacing relay circuit and the following unserviceable items and complete all as specified and as directed. (a) Automatic ON/OF Relay = 01 No (b) Aux Contacts 2NO+2NC = 01 No (c) Auto main failure relay 24 Volts = 01 No (d) Builtin voltage relay for main = 01 (e) Adjustable timer = 01 No (f) Main incomming dalay timer = 01 No (g) HRC Fuse with base 32 Amp = 01 Set (h) CT 400/5. Make : Kappa = 06 Nos (j) Power contactor 3 Pole , 200 Amp, ML 10, 2NO+2NC with aux contact. Make : L&T Cat Part No.SS90921 or equivalent approved make. (k) Push Button = 05 Set (l) DC Volt meter for inbuilt battery charger = 01 No
Maintenance / servicing of LT ACB upto1000Amp Capacity, 415 V -50/60 Hz,Icu-50 kA Ics-50 kA,Icw-50kA for 1 second of make L & T with Cleaning and servicing of all fixed and moving contacts replacement of accessories i.e lockable trip push button, LIP, LAP, racking, interlock, door interlock, shunt release, under voltage release(UVR) etc after disconneting the ACB for execution of work and re-fixing the same shall be with old serviceable spare parts in existing position and re-connecting all cables and testing on existing load complete all as specified and as directed.
Maintenance of Vacuum Circuit Breaker, 7.2 KV, 400 Amps, for trouble free operation, opening the incoming/out going cables carefully after disconnecting the supply, cleaning all terminals, fixed/moving contacts, cleaning vacuume interrupter, insulating coupler, strut, centering ring, all terminal clamp and bolts, drive link, upper/lower post insulators, etc. Special care need to be exercised in removal or insulation of hardware around the bottom, movable contact end of the vacuum interrupter, etc and refixing all cable terminals, cover, etc including the following inspection and checking should be carried out : - (a) Primary power path check (i) Cleanliness check (ii) Inspection of flexible connections (b) Stored energy operator-mechanism checks (i) Maintenance and lubrication (ii) Fastner Check (iii) Manual spring charging check (c) Electric Control Checks (i) Wiring and control check (ii) Secondary disconnect check (iii) Automatic spring charging check (iv) Electrical close and trip check (d) Vacuum Integrity check (e) High potential check (f) Insulation test (g) Contact resistance test (h) Inspection and cleaning of circuit breaker insulation (j) All safety and realay functional tests to be carry out and test report to be submitted to the engr-in-charge
Note : - (i) Any cleaning compounds containing chlorinated hydrocarbons, such as trichlorethylene, perchlorethylene or carbon tetrachloride will not be allowed to use which may be occured to damage the phenylene ether copolymer material used in the barriers and other insulation on the circuit breaker. (ii) Contractor will ensure to provide recommended tools for the maintenance works of the VCB. (iii) Contractor will ensure and take all safety pre-cautions/preventive measures against the mechanic/electrician at his own risk. (iv) The contractor will provide authorised persons to work from the OEM.
Supply only against item No.12 here-in-before as per existing make and size :-
(a) Strut
(b) Upper Connection pad
(c) Lower connection pad
(d) Contact pressure spring
(e) Insulating coupler
M & L for servicing to the DG set comprising of the following works for the capacity 320 KVA complete all as specified and as directed by the Engr-in-Charge :- (a) Draining out unserviceable engine oil from engine, refill with new. Note : Engine oil will be measured and piad separately. (b) Cleaning all sludge/deposits in the oil sump and removed off the site (c) Cleaning and replacing the primery, secondary and bi-pass fuel filters (d) Cleaning and replacing oil filters (e) Cleaning of air filters (f) Supply and replace unserviceable hose pipe as required at site (g) Supply and replace PVC fuel indication tube (h) Supply and replacing battery terminals = 02 Set (All new spare parts will be measured and paid separately)
All as per item No.14 here-in-before but capacity 200 KVA DG Set
All as per item No.14 here-in-before but capacity 125 KVA DG Set
All as per item No.14 here-in-before but capacity 110 KVA DG Set
All as per item No.14 here-in-before but capacity 100 KVA DG Set
All as per item No.14 here-in-before but capacity 60 KVA DG Set
Supply and fixing push button suitable for existing panel complete all as specified and as directed.
Taking down water pump assembly from the existing position, opening into parts overhauling the same with replacement of water pump repair kit, ball bearing (1No) (Make SKF/NBC), water pump, gasket seal, oil seal and re-assembling and refixing on the base for the following capacity of DG sets complete all as specified and as directed :-
(a) 110 KVA DG Set
(b) 320 KVA DG Set
(b) 60 KVA DG set
Taking down the Dynamo 12 Volts (Make LUCAS) from the existing position, shifting to the work shop, opening into parts, cleaning to sort out the unserviceable part, replace by new one, rewinding and warnishing of coil, reassembling and refixing to its base including transportation charge from work shop to the site for the following capacity of DG sets complete all as specified and as directed :-
(a) 110 KVA DG Set
(b) 100 KVA DG Set
Maintenance, servicing, tunning of diesel engine by calibration of FIP's adjustment of nozzle pressure and other controls and testing for following capacity of engine complete all as specified and as directed :-
(a) 125 KVA DG Set
(b) 110 KVA DG Set
Taking down self starter assembly from the existing position, opening into parts, sort out the unserviceable items like carbon bush, pinion etc and replace the same with new one including rewinding of field coils, re-assembling and refixing the same in its original position including testing for the following capacity DG Set complete all as specified and as directed :-
(a) 125 KVA DG Set
(b) 100 KVA DG Set
Dismantling the alternator of DG set 320 KVA, Make Kirloskar, from its base by using chain and pulley after removing the coupling with the engine, removing all nut, bolt with washer and all electrical connections of the alternator, shifting the alternator to work shop, opening the same parts, checking all winding like main stator/rotor winding, exciter stator/rotor winding. Rewinding the main rotor and exciter rotor by using the same insulation and gauge and type of magnet wire that was on the original motor. Refixing the complete including connection to the terminal box of the alternator at work shop and shifting the same to the site. Fixing the alternator to its base carefully by using chain and pulley, connecting it with existing engine including checking the alignment of alternator with the engine, connecting all electrical connections of the alternator and testing the DG set on "OFF/ON LOAD", matching to the existing range of RPM of the engine and all to the satisfaction of the engr-in-charge.
Removing the radiator assembly of DG Set capacity upto 200 KVA from its base, taken to workshop, opening into parts, carryout overhauling the complete system, sort out and replacement of the unserviceable items, cleaning the channels, fins including necessary gas welding works, reassembling and refitting on its base including transportation of the same from work shop to site complete all as specified and as directed. (Note . Spare parts will be measured and paid saperately)
Taking down unserviceable automatic battery charger including disconnecting of all connection and replacing with new autocut battery charger suitable for charging upto 24 volt 180 AH (2x12Volt) battery complete with provn of necessary connection complete all as specified and as directed.
Supply, install and commission control Panel unit of 320 KVA Capacity DG Set by removing the old unserviceable control unit and testing complete all as specified and as directed
Supply and filling Fleet cool HD heavy duty coolant concentrate ultimate protection for increase engine life for 200 KVA,100KVA complete all as specified and as directed. Make : Fleet guard Batch No 16311 or equivalent approved make.
Supply only engine oil of grade 20W 40 brought at sight in sealed container. Complete all as specified and as directed. Make :- Power oil/ castrol/gulf /servo Note Contractor will submit purchese voucher and manufacturer's test certificate in original before any payment.
Supply only fuel filter ( primary, secondary or by pass ) for the following capacity of DG set complete all as specified and as directed
(a) 320 KVA DG set
(b) 200 KVA DG set
(c) 125 KVA DG Set
(d) 110 KVA DG Set
(e) 100 KVA DG Set
(f) 60 KVA DG Set
Supply only oil filter for the following capacity of DG set complete all as specified and as directed
(a) 320 KVA DG set
(b) 200 KVA DG set
(c) 125 KVA DG Set
(d) 110 KVA DG Set
(e) 100 KVA DG Set
(f) 60 KVA DG Set
Supply only suction connection in repair of radiator assembly for the following capacity of DG set complete all as specified and as directed
(a) 320 KVA DG set
(b) 125 KVA DG Set
(c) 100 KVA DG Set
Supply only main pipe in repair of radiator asssembly for the following capacity of DG set complete all as specified and as directed
(a) 125 KVA DG Set
(b) 100 KVA DG Set
Supply only rubber hose in repair of radiator asssembly of DG set complete all as specified and as directed
Supply only stud in repair of radiator asssembly of DG set complete all as specified and as directed
Supply only spacer in repair of radiator asssembly of DG set complete all as specified and as directed
Supply only hydraulic fuel pipes for DG set complete as specified and as directed
Supply only pipe from thermostat to water tank in repair of radiator assembly for the following capacity DG set complete as specified and as directed
(a) 125 KVA DG set
(b) 110 KVA DG Set
Repair/maintenance and servicing of oil cooled step down transformer 6 KV/433 Volt of capacity 2000 KVA, Make Kirloskar, comprising following work services :- (a) Disconnection of cable termination of HT & LT ends. (b) Opening of top cover by removing nuts, bolts and all mounting accessories and conservator tanks. (d) Cleaning all sludges from main oil tank and conservator tank and removal off the site. (e) Servicing of tap changing gears by cleaning and polishing tapping contact points. (f) Cleaning, polishing of serviceable bush and stud both HT/LT side and refixing the same. (g) Replacing unserviceable stud and bush as required as directed by Engr-in-Charge. Note : (i) While replacing and refixing the stud and bush all nuts, washers and gaskets are to be replaced with new one against the coated rate (ii) New bushes and studs required for replacement shall be measured and paid separately as 'Supply only'. ih) Refixing all cable terminals HV & LV sides and transformer top cover, conservator tank in position. (j) Cleaning and heating of silica gel in breather and replacing with new silica gel to make up the reduced quantity Note: New silica gel requied for replenishing shall be measured and paid separately as 'Supply only'.(k) Fixing as in repair of buchholz relay. Note: New buchholz relay required for replacement shall be measured and paid separately as 'Supply only'. (l) Connecting HT & LT side with existing incoming and outgoing cables including reconnection of earth strip/lead.Note: (1) HT side cable connection shall be made with new HT tape & M Seal Monoplast. (2) M seal monoplast required for replacement shall be measured and paid for separately as 'Supply only'. (3) The items of work mentioned here-in-after are tentative and may vary as per site requirement as assessed by the representative and the Engn-in-Charge after strip inspection and the contractor shall have no claim on that account. (4) Contractor wiil be very careful and should ensure not to enter any type of moisture in side the transformer during maintenance.
All as per item No 40 here-in-before but for transformer capacity upto 500 KVA,
Supply only porcelain transformer bushing LT side as per existng size/Model of following capacity of transformer:-
Supply only porcelain transformer bushing HT side as per existng size/Model of following capacity of transformer:-
Supply only transformer studs of brass for HT as per existng size/Model of following capacity of transformer:-
Supply only transformer studs of brass for LT as per existng size/Model of following capacity of transformer:-
Supply only M seal monoplast kit for Buck/Boost transformer of 2000/400/315 KVA capacity.
Supply only transformer oil temperature gauge dial type range 0 to 100 deg C as per existing type and model.
Supply only Silica gel in existing breather assembly.
Supply only MS bolts, nuts and washer of required size.
Supply only GI bolts, nuts and washer for transformer oil tank, cable end box and other parts of transformer of required size.
Disconnection of all Primery/Secondary connection of the defective transformer capacity upto 2000 KV rating out door / indoor any make taking down / out from plinth / pole / platform with the help of crane and transporting the same carefully to workshop for repair and bringing back and install, with all connections as per directed, after repair to its existing position, of transformer complete with testing and commissioning, all as directed.
Making Primary/Secondary coil with insulating copper wire of required gauge craft paper cotton tape HT/LT insulation as per specification of old transformer including making of coil as required upto 500 KVA capacity of transformer complete all as directed. Note :- Contractor should obtain & submitt the warranty certificate of one year from the manufacture.
M&L for painting of capacity upt0 500 KVA transformer pole mounted / plinth mounted at site and applying two coats of synthetic enameled smoke grey paint after removing all dust & rust and paint shall confirm to IS 2032 including marking or transformer capacity with stencil letter with black or white paint and font and size of letter complete all as specified and directed.
M&L for painting of capacity 2000 KVA transformer pole mounted / plinth mounted at site and applying two coats of synthetic enameled smoke grey paint after removing all dust & rust and paint shall confirm to IS 2032 including marking or transformer capacity with stencil letter with black or white paint and font and size of letter complete all as specified and directed.
Supply and fixing auxiliary contact A600 P600, 10A, 690 V Conforms to IEC/EN 60947-5-1, and including taking down old unserviceable one and making good the disturbed surface complete all as specified and directed. Make :L&T/Legrand/C&S or equivalent approved make.
Supply and fix as in repair CT for Amp meter ratio 400/5 Amps (Set of 3 Nos) complete all as specified and as directed. Make-AE/Kappa
All as per item No 56 here-in-before but ratio 200/5 Amps.
Filteration and dehydration of old transformer oil and removing of sludge by continuous circulation through transformer oil filtration plant with heater strips to achieve dielectric strength of not less than 50 KV at 2.5 mm gap of electrode, improvement of acidity by minimizing percentage of acidity using chemical reagents complete all as spedified and as directed. Note : (i) Filteration of transformer oil shall be carried out as per IS-1866(1983). (ii) Filteration of transformer shall be carried out using filtration plant equipped with circulating pump, series of column filter papers, heater strips and capacity 125 GPH(min). (iii) Transformer oil test before and after dehydration shall be carried out by the contractor and copy of same will be enclosed during claim of payment duly signed by Engr in charge and contractor.
Supply only transformer oil having di-electric strength not less than 50 KV after initial dehydration/filteration conforming to IS 335 and ISI marked to be brought at site in sealed container complete all as specified and as directed.
Supply and fixing for Start-stop-reset push button with LED lamp including all necessary incoming and outgoing electric connections after and including taking down old unserviceable one and making good the disturbed surface complete all as specified and as directed. Make : L&T Cat No EALTDI or equivalent approved make of Legrand /. ABB/C&S
Supply and fixing for Voltmeter, single phase, class - 1, digital type after and including taking down old unserviceable one complete all as specified and as directed. Make : L&T Cat No. WDS101FEV00 or equivalent approved make of Legrand / ABB./C&S
Supply and fixing for Ammeter, single phase, class - 1, 5A digital type after and including taking down old unserviceable one complete all as specified and as directed. Make : L&T Cat No. WDS101FCA00 or equivalent approved make of Legrand / ABB/C&S.
Supply and fixing for Current Transformer 160/5 after and including taking down old unserviceable one complete all as specified and as directed. Make : Kappa/AE
Supply and fixing for SPGD -2 relay with CTs 40 Amp after and including taking down old unserviceable one complete all as specified and as directed. Make : Minilac/L&T
Supply and fixing for "On/ off " trip indicatior after and including taking down old unserviceable one complete all as specified and as directed. Make : L&T/Vishnu
Supply and fix on load change over switch 400 Amps 415 Volt 4 pole after and including taking down old unservoceable one complete all as specified and as directed. Make :- L&T /Havells/ Legrand
Supply and fix on load change over switch 630 Amps 415 Volt 4 pole after and including taking down old unserviceable one complete all as specified and as directed. Make :- L&T /Havells/ Legrand
Earthing with copper earth Plate Electrode 600X600X3.15mm, buried directly in Ground vertically at a depth not less than 2.25 metre below Ground Level with the top edge of earth Plate at a depth not less than 1.50 metre below Ground Level connected to copper strip of size 20x3mm as earth lead by means of bolts, nuts, check nuts and washers of copper , earth Plate electrode surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt in alternate layers of not exc. 150mm thick, GI Strip protected with and including 40mm bore GI Light Grade Pipe upto 1.0 metre above the floor level of the building where Main Switch/DB situated including PCC Pit in Cement Concrete (1:3:6) type C1 (20mm Graded Stone Aggregate) and RCC Cover of size 450X450X50mm in RCC (1:2:4) type B1 (20mm Graded Stone Aggregate) reinforced with and including 8.0mm dia TMT Bars @ 100mm centre to centre both ways, GI Wire Mesh, funnel, 20mm bore medium grade GI Watering Pipe, necessary excavation in soft/loose soil, returning, filling in and removal of surplus spoil upto a distance of 50.00 metre and all as shown in Electrical Plate No. 5 of MES Schedule Part-I and Testing on completion including taking down unserviceable Earthing ,complete all as specified and directed.
Material and labour in replacement for galvanised iron strip 20 x3 mm burried in ground or on wall with clamping arrangement ,complete all as specified and directed.
Material and labour for painting of panel board any size at various sub stations/locations with two coats of superior quality of synthetic enamel paint after cleaning of existing surface including marking of incoming feeder and outgoing feeder with letters n. exc 15cm height complete all as specified and as directed. Note : The superficial area for the purpose of painting shall be considered as n exc 15 Sqm.
Material and labour for taking down centrifugal pump from existing position, dismantling the same to carry out repair works including replacement of required spare parts, reassembling, reinstalling, checking for alignment with motor and connecting complete for following capacity of pump. Note: Spare parts required for renewal shall be measured and paid separately.
Supply only of following spare parts for pump set including motor complete for 30 HP centrifugal pump:-
(a) Impeller CI
(b) Pump shaft
(c) Stage bushing
(d) Coupling
(e) Bearings Make : SKF or equivalent approved make.
Supply only of following spare parts for pump set including motor complete for 25 HP centrifugal pump:-
(a) Impeller CI
(b) Pump shaft
(c) Stage bushing
(d) Coupling
(e) Bearings Make : SKF or equivalent approved make.
Supply only of following spare parts for pump set including motor complete for 20 HP centrifugal pump:-
(a) Impeller CI
(b) Shaft
(c) Stage bushing
(d) Coupling
(e) Ball bearing Make : SKF or equivalent
Supply only of following spare parts for pump set including motor complete for 10 HP centrifugal pump:-
(a) Impeller CI
(b) Shaft
(c) Stage bushing
(d) Coupling
(e) Ball bearing Make : SKF or equivalent
Dismantling and opening the motor from pump set in existing position for carrying out rewinding work with new super enamelled copper wire of suitable gauge as per existing and heat varnishing complete with all other material required for rewinding, re-assembling and refixing the same with pump in original position for the following capacity of motor :-
Labour only for lifting/ lowering of U/S submersible pump set from tube wall after disconnecting the electric supply and taking out all coloumn pipes flanged/ socket type of any length keeping serviceable fittings in safe custody for reuse, removing unserviceable materials from site, making good of disturbed surfaces and carrying submersible pump set to nearest repairing workshop including bring back after necessary repairs and lowering the same including all necesary fixtures like rubber gasket/nuts/bolts/washers of suitable size or welding materials for jointing cloumn pipes flanged/ socket type and connection of electric supply to motor, testing/commissioning, etc. complete all as specified and directed. Note. : Replacement of Column pipes shall be measured and paid seperately.
Material and labour for necessary repair to motor of submersible pump and taking out burnt windings, cleaning, re-winding with superior quality super enamelled copper wire of existing gauge, overhauling, refixing and testing complete for following capacity of pump.
M & L for overhauling of submersible pump of 6 to 8 stage, 20 HP installed at pump house with cleaning, Stage casing, Carbon trust bearing with pressure plate, suction strainer, diffuser bronze, Impellers,Thrust bearing housing, Bearing segment carrier (C.I), diaphragm (rubber), Stud nut and bolt 8.0 mm dia and length as per requried, greasing, repairs to pump including replacement of spares parts like clamps, Impeller bushing, dischrage/suction casing, Gaskets etc & connected accessories all as specified and directed.
M & L for painting of 20/10 HP capacity submersible pump set after removing old painted/rusted surface by paint removers such as blow lamps, scrapers etc over the surface of motor and pump body and outer surface of column pipes, 18.45 M long and painting with two coats of anti- corrosive synthetic paint over two coats of red oxide primer and shall be painted with electrical spray machine and writing MES NO & CAPACITY by using white paint on painted surface on directed location complete all as specified and as directed.
Supply and fixing water proof submersible flexible flat copper cable, 10 Sqmm 3 core, 1100 Volts complete all as specified and directed. Note : Rate quoted shall be deemed to be inclusive of the cost of under water fixing arrangements complete.
Supply and fixing water proof submersible flexible flat copper cable, 6 Sqmm 3 core, 1100 Volts complete all as specified and directed. Note : Rate quoted shall be deemed to be inclusive of the cost of under water fixing arrangements complete.
Material and Labour for painting of centrifugal pump set including MS channel after removing old painted/ rusted surface by paint removers such as blow lamps, scrapers etc over the surface of motor/pump/MS chanel and painting with two coats of synthetic enamelled paint over a coat of red oxide primer complete all as specified and as directed.
Material and labour for writing letters or figures (Block, Roman, Italic or Indian) n. exc 30 cm high complete.
Material and labour for writing stops, commas, short lines, dashes, hyphens, brackets, etc complete.
Supply and fixing in repair single phase preventor suitable for 3 phase motor including taking down of unserviceable one complete all as specified and directed. Make: Minilec Cat No VSP3 or equivalent approved make.
Supply and fixing in repair fully automatic star-delta starter of relay range 14-23 Amps, in Sheet-Steel enclosure suitable for upto 30 HP pump including taking down of unserviceable one complete all as specified and directed. Make - L&T Cat No SS94364 or equivalent.
Supply and fixing in repair fully automatic star-delta starter of relay range 66 - 110 Amp, ML6 FASD, in sheet steel enclosure with single phase protection feature suitable for upto 125 HP pump including taking down of unserviceable one complete all as specified and directed. Make - L&T cat No SS90923 or equivalent.
Supply and fixing as in replacement three pole power contactor AC 3 - 25 Amps, 2 NO + 2 NC, ML1.5 type complete all as specified and directed. Make- L&T. Cat no SS91851 or equivalent.
Supply and fixing as in replacement Three pole power contactor AC 3 - 32 Amps, 2 NO + 2 NC, ML2 type complete all as specified and directed. Make- L&T. Cat no SS90701 or equivalent approved make.
Supply and fixing in repair SPGD -2 RELAY WITH CTS -40 Amp including replacement of old unserviceable one complete all as specified and as directed. Make : MINILAC or equivalent approved make.
Supply and fixing in repair Start -stop-Reset push button Amp including replacement of old unserviceable one complete all as specified and as directed. Make : L&T or equivalent approved make.
(a) First day compressor runs
(b) Second day compressor runs
(c) Third day till quality water achieve.
M & L for pea gravels fillings (coarse sand mud free) washed pee gravels of size 4 mm to 6 mm for filling packing around casing of deep tube well for derived depth complete all as specified and directed.
Supply and fixing MS column pipes of 03 (three) meter heavy duty 100 mm dia bore, both end threaded with heavy duty socket or fixed with two Nos flanges on both end, including welding and painted with electrical spray machine both inside and outside with two coats of black anti- corrosive synthetic paint (suitable for drinking water) over two coats of red oxide primer complete all as specified and directed.
Supply and fixing cast iron sluice valve with flanged ends heavy duty of class PN 1.6 (ISI marked) comprising of gun metal spindle or brass spindle with gun metal nut and cast iron operating wheel, including necessary rubber gasket joint with nuts, bolts and washer complete all as specified and as directed.
(a) Sluice Valve 150 mm dia bore size
(b) Sluice Valve 100 mm dia bore size
Supply and fixing as in repair 50 mm bore dia Gun metal gate valve with iron wheel head, screwed both ends for iron pipes or for unions complete all as specified and as directed.
All as per item No 99 here-in-before but 40 mm dia
Supply and fixing 150mm dia Cast iron butter fly valve heavy duty of class PN 1.6 confirming to IS-13095-1991 including all accessories after and including taking up/down of old unserviceable valve complete all as specified and as directed
All as per item No 101 here-in-before but 100mm dia and -ditto-.
All as per item No 101 here-in-before but 80mm dia and -ditto-.
All as per item No 101 here-in-before but 50mm dia and -ditto-.
Supply and fixing power contactor four pole integrated auxillary contact 2 NO+2VC, AC1 rating 700A MCX 46 complete all as specified and directed.
Supply and fixing in repair three pole power contactor integrated auxillary contact 2NO+2NC, AC 3-110, ML-6 complete all as specified and directed.
Supply and fix as in repair Self starter suitable (OEM) 24V suitable upto 200 KVA DG Set including recojnedction of wire and testing complete all as specified and directed.
Supply and laying in trenches / Bituminus roads/ PCC pathway 150mm dia centrifugally cast (spun) Ductile iron pressure pipes with spigot & socket end, class K-9 conforming to IS-8329/2000 (latest revision) with inside cement mortar lining and mettalic zinc coating and outside black bitumen coating and having portland cement properties suitable for push on tyton jointing including EPDM rubber gasket and joints but excluding specials including taking down old unserviceable pipe of any type complete all as specified and directed.
All as per item No 108 here-in-before but 100mm bore size and -ditto-.
Dimantling and taking up of old fittings and Supply and fixing DI specials class K-12 both end flanged or both end spigot/socket or one end flanged and other end spigot/socket any type such as bends, tapers, reducers, duck foot bend, tee pieces (single and double branch), etc including cutting of pipes for upto 150 mm dia ductile iron pipe as per site requirement complete all as specified and as directed.
Excavation in trenches not exc 1.5 m in depth and not exc 1.5 m wide for taking out/laying CI/ DI pipes and getting out in soft/loose soil complete all specified and directed.
Removing excavated soil at a distance not exc 50 m and deposit where directed at a level n.exc 1.5 m above the starting point complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well rumming in layers not exc 25 cm complete all as specified and directed.
Cutting of existing PCC flooring/ bitumen road/ pathway/ any tile work / plinth protection for laying of pipe upto 150 mm dia n.exc 50 cm in width and 90 cm in depth and removing the debris to a distance not more than 50 m complete all as specified and directed.
Supply and fixing as in repair water tank cover heavy duty chequered type made up of cast iron of size 58.5cm dia and 6mm thick with handle and suitable for existing bottom frame of the cover of RCC OH tank complete all as specified and as directed.
Supply and fixing hydraulically operated Altoch Dozing System Model ADS-PRO including testing and commisioning complete all as specified and directed.
Supply and fix ACB 4 Pole, 415 V, with Manual Drawout type with microprocessor release of capacity of capacity 800 Amps
Supply and fix ACB 4 Pole, 415 V, with Manual Drawout type with microprocessor release of capacity of capacity 1600 Amps
Dismantling of old unserviceable Panel and Supply & fabrication of LT Panel Board of size 2400mm x 1500mm x 450mm CPRI approved cubical type made of 2 mm thick sheet steel indoor type with IP 67 grade of protection CRCA sheet powder coated with support of angle iron of 50 x 50 x 6 mm angle iron bottom legs with minimum height of 20 cm frame with double hinged front openable shutters of each feeder control unit with locking arrangement in front and back openable inspection doors PVC sleeved Aluminium bus bar of 1000 Amps capacity for each phases and half neutral fixed on suitable insulator all housed in suitable bus bar chamber and cable alloy including provision and fixing of digital Voltmeter -01 No, Ammeter-01 No, CTs of suitable ratio, and Indicating LED type lamp for Red, Yellow and Blue in incomer phases complete along with provision of necessary cable entry/exit boxes for all incoming and out going cables with suitable cable glands etc fixed on suitable PCC foundations complete testing and commissioning complete and suitable for accomodating MCCB 125A-17 Nos, Change over switch 630A - 01 Nos and MCCB 630A-01 Nos (as incomer). (Drawing of Panel and connections shall be approved before starting the panel work and taking down old unseriveable from site as directed
S&F for MCCB adjustable thermal and magnetic 125 Amps, 25 KA 4-Pole type, including all arrangement for mounting and testing, operating on 415V, 50Hz , AC supply, including taking down of old unserviceable one complete. Make : Standard/Havells/C&S
S&F for MCCB adjustable thermal and magnetic 630 Amps, 50 KA 4-Pole type including all arrnagement for mounting and testing, operating on 415V, 50Hz , AC supply, including taking down of old unserviceable one complete. Make : Standard/Havells/C&S
TOTCO
SEN ELECTRIC WORKS
ARATI TRADING CO
PUTUL CONSTRUCTION CO.
Tirupati Buildcon Pvt. Ltd.
SOMANI BUILDERS
NUPUR CONSTRUCTION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .