Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.1 CrAccepted-AOC PLOT NO G 36 SECTOR 20 NAVI MUMBAI 400614 | THANE | MAHARASHTRA | 400614 | ₹20.1 Cr | L1 | Accepted-AOC BEING LOWEST |
| 2 | L2₹21.7 CrRejected-Finance SHREE SHYAM SADAN 10 2 PARAS SOCIETY PANCHVATI JAMNAGAR GUJARAT 361008 | JAMNAGAR | GUJARAT | 361008 | ₹21.7 Cr | L2 | Rejected-Finance NOT BEING L1 |
| 3 | L3₹21.7 CrRejected-Finance K 99 LGF KALKAJI NEW DELHI 110 019 | NEW DELHI | SOUTH EAST DELHI | DELHI | 110019 | ₹21.7 Cr | L3 | Rejected-Finance NOT BEING L1 |
| 4 | L4₹21.9 CrRejected-Finance | ₹21.9 Cr | L4 | Rejected-Finance NOT BEING L1 |
| 5 | L5₹23.9 CrRejected-Finance L 87 STREET NO 7C MAHIPALPUR EXTENSION NEW DELHI 110037 | NEW DELHI | NEW DELHI | DELHI | 110037 | ₹23.9 Cr | L5 | Rejected-Finance NOT BEING L1 |
Tender Value
₹23.5 Cr
EMD Value
₹15 L
Closing Date
8 Dec 2022, 6:00 pmClosed
CHIEF ENGINEER (CG) GOA
CHIEF ENGINEER (CG) GOA 403806
PROVISION OF HANGER WITH APRON LINK TAXI TRACK AND EARTH FILLING AT JUHU MUMBAI
2022_MES_518327_5
82079/E8
Open Tender
Civil Works
720 days
JUHU MUMBAi
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹3,000
GE (I) CG DAMAN
₹15 L
Yes
11 Feb 2023
17 Nov 2022
10 Dec 2022
17 Nov 2022
8 Dec 2022
1 Dec 2022
Amount
SCHEDULE "A" Part - I (Building works) Details of prepriced schedule is given in tender documents.
SCHEDULE "A" PART-II ( Site Clearance, Area Development, Excavation & Earth work ) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-III (Internal Electrification other than PEB hangar ) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-IV (Internal Water Supply other than PEB hangar ) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-V (Roads, Path & Culverts ) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-VI (Fire Fighting) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-VII (External Electrification) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-VIII (External water supply) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-IX (Lightening Protection) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-X (DG Sets) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-XI (Aviation obstruction Light/ Conduit for TV & Telephone) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-XII(Refrigeration and Air Conditioning) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-XIII (Provisional sum) This item covers the cost of (i) Demolition of existing floor ( At location of H-2 hangar and its Annexe), demolition of existing foundation at the location of H-2 Hangar and its Annexe (If required). (ii) Designining the foundation, getting it vetted from IIT/NIT/Govt Engg College and Material and lobour including execution of complete foundation of Hangar -2 and its Annexe. (iii) Design of foundation and its vetting from IIT/NIT/Govt Engg College is deemed to be included in the over all cost of provisional lumpsum, nothing extra shall be paid. (iv) While designing the new foundation, existing foundation can be made use of in hybrid mode with new foundation, post adequate testing of its strength and approval from Accepting Officer. Decision of feasibility of utilizing existing foundation in hybrid mode with new foundation will rest solely with Accepting Officer. (v) Items which are not available on SSR shall be priced as per Condition 62 of IAFW 2249.
SCHEDULE "A" PART -XIV (MISCELLANIOUS ITEMS) Note:- This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col.' E ' signifies this fact only.
(a) Design, manufacture and erection of PEB Hangar in steel structure for construction of Hangar No-1 of size as shown in drawing, with PCC block masonry wall upto 3.0mt height on both side of hangar, horizontally sliding type steel automated door as shown in drawing on front side, galvalume sheet in roofing and cladding, all primary steel surfaces painted with epoxy based paint, 200mm thick PQC of flexural strength of 45mpa in floor Including 200mm thick GSB - V of grading,150mm thick (Compacted thickness) WMM in two layers 75mm each, 125mm thick (Compacted thickness) DLC, 10mm thick sand filling, HDPE sheet 400micron, non circular synthetic fibre, Expansion joints, Construction Joints, Dummy joints, 5.3mm ESD- Epoxy antiskid floor coating, including excavation in any type of soil/soft disintegrated rock and foundation all as specified in Schedule ‘A’ notes, Particular specification, drawings and Tender documents. (b) Design & construction of Annex Bldgs for Hangar No 1 (G+3 configuration) in permanent specifications, RCC framed structure including foundation, RCC water storage tank (20000 Ltr Capacity on roof slab of Annexe Building for fire fighting) all as specified in Schedule ‘A’ notes, Particular specification & drawings (Note: Internal Electrification and Internal water supply for Annexe of Hangar No 1 building shall be measured and paid under relevant item of Sch 'A' Part-III & Part-IV)
(a) Design, manufacture and erection of PEB Hangar in steel structure for construction of Hangar No-2 of size as shown in drawing, with PCC block masonry wall upto 3.0 mt height on both side of hangar, horizontally sliding type steel automated door as shown in drawing on front side, galvalume sheet in roofing and cladding, all primary steel surfaces painted with epoxy based paint, 200mm thick PQC of flexural strength of 45MPa in floor Including 200mm thick GSB - V of grading,150mm thick (Compacted thickness) WMM in two layers 75mm each, 125mm thick (Compacted thickness) DLC, 10mm thick sand filling, HDPE sheet 400micron, non circular synthetic fibre, Expansion joints, Construction Joints, Dummy joints, 5.3mm ESD- Epoxy antiskid floor coating all as specified in Schedule ‘A’ notes, Particular specification, drawings and Tender documents. (b) Design & construction of Annex for Hangar No 2 (G+3 configuration) in permanent specifications, RCC framed structure, RCC water storage tank (20000 Ltr Capacity on roof slab of Annexe Building for fire fighting) all as specified in Schedule ‘A’ notes, Particular specification & drawings (Note: (i) Internal Electrification and Internal water supply for Annexe of Hangar No 2 building shall be measured and paid under relevant item of Sch 'A' Part-III & Part-IV) (ii) The quoted amount for this item shall not include cost of foundation design including M&L and execution of foundation. The same shall be as per rate quoted against item No 13 ie, Sch 'A' Part XIII for provisional lumpsum. (iii) The quoted amount for this item includes cost of all items and structures of Hangar -2 and its annexe, above the top of pile cap/grade beam in case of pile foundations and top of plinth beam in case of raft/open foundation. Dowels of columns to be anchored in pile cap shall also be part of lump sum.
Design and Construction of POL Storage Accommodation including foundation, RCC framed structure etc all as specified in Schedule ‘A’ notes, Particular specification & drawings. Note: Internal electrification and Internal water supply shall be provided all as shown on drawing and shall be measured and paid vide Sch A Part III & IV respectively
Design and Construction of Battery Charging shop including foundation RCC framed structure etc all as specified in Schedule ‘A’ notes, Particular specification & drawings. Note: Internal electrification and Internal water supply shall be provided all as shown on drawing and shall be measured and paid vide Sch A Part III & IV respectively
S&F HDPE bird proofing net 1mm thick, aperture size 25mmx25mm supported on aluminium section frame work, (Aluminium work to be measured separately)
S&F supporting anodised aluminium frame work shall be of panel size 4.0m x 2.0m with main aluminium Tee size 101mm x 45mm x 3.1mm thick & cross aluminium Tee size 40mm x 40mm x 5mm thick complete all as specified and directed or as specified by GE.
FIRE FIGHTING: Supply and fix Foot Valve conforming to IS 4038, 100 mm dia.
Supply and fix Foot Valve conforming to IS 4038, 150 mm dia.
Supply and fix Mild Steel class 'C' diesel pump exhaust pipe 150mm dia with one layer of10mm thick asbestos rope insulation and including all fitting clamp/ structural steel supports complete
Supply and fix Cast Iron Air Valves with single air Outlets, conforming to IS 14845 of size 50 mm dia bore and fixing up in Cast Iron Water supply mains of size 50 mm dia.
Supply, laying & testing PVC insulated, PVC sheathed cable galvanized steel strip or wire armoured, electric control cables (Heavy duty) with stranded copper conductor of size 1100 Volts grade.
3 Core, 1.5 Sq mm,
6 Core, 1.5 Sq mm,
S& F wall mounted LED emergency Exit signage luminaireLight up using regular mains supply comes with a unique rechargeable NI-Cd battery capable of emergency back up upto 02 hours ( cat No BESL 03 LED WBB Make - Bajaj or equivalent to Havells/ Philips
S & F Monitors SS-304 geared swivel nominal water way of size 63 mm flow capacity 1750 lpm/ min at 7 Kg / Sqcm inlet pressure stailnelss steel type (SS304) with geared swivel joints with handwheels have suitable inlet flange and nozzle of specified type and capacity. Monitor shall good hydraulic performance and range.
Supply and fixing S.S Foam Tank Made out of 3mm thick SS 304 plate with required nozzles, stand, level gauge, coupling, jointing materials, etc, with all required accessories of capacity 200 Ltrs and all as specified and directed.
S & F foam generator of capacity of 7 Kg/Sqcm total water flow 230 LPM complete all as specified and as directed
AFFF 3% Foam Concentrate, as per IS:4989, Part-II and all as specified and directed.
Supply, install,test and commisioning ABC dry powder ceiling mounted atomatic fire suppression system of capacity 5 Kg all as specified and as directed.
Supply and installation at approved location approved make fire sand bucket of 24 gauge galvanised steel sheet ,each set shall have 4 buckets with stand & Showel etc, complete.
Supply, Installation,Testing & commissioning of MECHANICAL FOAM type fire extinguisher of 9 Ltrs confirm to IS : 15683, with ISI marked/TAC approved fitted with required accessories including wall suspension brackets.
Supply, Installation,Testing & commissioning of DRY CHEMICAL POWDER (ABC) stored pressure type fire extinguisher of 6 Kg confirm to IS : 15683, with ISI marked/TAC approved fitted with required accessories including wall suspension brackets.
Supply, Installation,Testing & commissioning of Carbon Dioxide (Co2) type fire extinguisher of 4.5 Kg confirm to IS : 15683, with ISI marked/TAC approved fitted with required accessories including wall suspension brackets.
Supply install, and commissioning LT feeder pillar Outdoor, type made out of 3.15mm thick MS sheet and angle Iron frame work, cubicle type with copper bus bars and with suitable mounted plate, frame and canopy, confims to IEC61439-2 with following assesccories suitable for incoming/outgoing arrangements:- a) Incoming- ACB 630A 4 pole, 65/70KA, mechanical draw out type-01 No. b) Out goings :- i) MCCB 250A ,4 pole, 50 KA-03 Nos ii) MCCB 120A ,4 pole, 35 KA-02 Nos iii) MCCB 32,4 pole, 35 KA-03 Nos iv) Digital panel meter for Volt/Amp/KWH & PF, necessary CT-01 No
Supply install, and commissioning LT feeder pillar Outdoor, type made out of 3.15mm thick MS sheet and angle Iron frame work, cubicle type with copper bus bars and with suitable mounted plate, frame and canopy, confims to IEC61439-2 with following assesccories suitable for incoming/outgoing arrangements:- Incoming:- a) ACB 800A 4 pole, 50 KA-01 Nos Out going ;- b) ACB 800A 4 pole, 65/70KA, mechanical draw out type -01 No. c) MCCB 160A 4 pole, 50 KA-01 Nos d) MCCB 200A 4 pole, 50 KA-03 Nos e) LED indicating lamp set-01 Set of three (f) Digital panel meter for volt Amp/Volt/KWH & PF, necessary CT-01 No
Supply and fix LED flood light 120 watt 230 V AC IP 65 protection out door type with thermal manangement in multiple optics and equipped with IP 66 protection,with impact and corrosion resistant complete with driver and lamp including fixing arrangement complete all as directed.
Supply and fixing cable tray 200mm wide X 25mm deep hot dip galvanized with standard slot pattern manufactured from CRCA sheet 2.00mm thick, perforated type including provision of fixing arrangement, nuts & bolt etc for proper securing to walls/beams for suspended from ceiling, complete all as specified and directed.
Supply and fixing cable tray 150mm wide x 50mm deep hot dip galvanized with standard slot pattern manufactured from CRCA sheet 2.00mm perforated type including provision of fixing arrangement, nuts & bolts etc for proper securing to walls beams or suspended from ceiling, complete all as specified and directed
Supply and fix FRP looping box of size 250x200x105mm with connector and comprising of MCB SP 10 Amps, ISI marked, 240V complete with and including providing GI clamps,nuts bolts etc suitable for fixing on PCC pole/Steel Pole/ wall etc complete all as specified and directed.
EXTERNAL WATER SUPPLY:- Supply and fix foot valve confirming to IS 4038,50 mm dia
Supply and install Monoblock pump set suitable for 415 v, 3 phase system having capacity 7.5 HP including GI pipe of suitable size for inlet and outlet connection including necessary PCC platform/ foundation for pump complete all as directed
Supply and fix DOL starter suitable for and up to 7.5 HP in & including sheetmetal enclosure and fixing arrangement complete all as directed.
Construction of valve chamber with inner dimension 600x600x900 mm suitable for 80 mm sluice valves with PCC (1:4:8) 150 mm thick type D2 for foundation, Brick masonary 230 mm wall in CM (1:4), PCC (1:2:4) 75 mm type B-1 for coping, rendering in CM (1:4) 15 mm thick including provision of 3 mm thick MS sheet cover and 25 x25x 3 mm angle frame embeded in coping with two coats of synthetic enamel paint over a coat of red oxide primer with locking arrangements including necessary earth work complete all as specified and directed by Engr-in-charge.
DG SET: Supply, installation, testing and commissioning of silent Diesel Engine driven generating set 415 Volts, three phase 4 wire, engine as per IS: 10001/ 10002 and alternator as per IS: 4722/ IS:13364 complete with anti vibration mounting etc, AMF control panel with necessary meters and sound proof canopy of capacity of 400 KVA comprising of the following :-. (A) DIESEL ENGINE: Liquid cooled, for 400 KVA developing suitable BHP @ 1500 RPM.,rail mounted, engine driven radiator of adequate capacity, with blower fan, fan guard, fan belts etc. The diesel engine shall be vertical to run continuously at 1500 RPM confirming to IS 10001/10002, ISO-3046, BS-5514, standards with an overload capacity of 10% for one hour in every 12 hours of operation. Diesel engine will comply with latest CPCB norms (B) ALTERNATOR : Alternator suitable to deliver output at 1500 RPM, 415V, 0.8 PF (LAG), 50HZ, 3PH, in SPDP enclosure, self-excited & regulated, brushes. The alternator conforms to IS-4722/BS EN 60034/1 IS: 13364 and will be suitable for tropical condition. Full load efficiency of the alternator offered should be above 90% class of insulation shall be H and temperature rise also limited to class H. Enclosure shall confirm to IP-23 and noise level should not be more than 75 dB at 1.0meter distance as per guidelines of Central Pollution Control Board. (C) STANDARD CONTROL PANEL : Following indication/ display and control shall be available in the DG set controller and monitoring system
(i) 01 No main on/off switch MCB (ii) 01 No set of indicating lamps (iii) 01 No set of instrument fuses. (iv) Digital display/ Indication (a) Lube oil pressure (b) Battery voltage (c) Engine RPM (d) Fuel level (e) Engine running hours indication (f) AC current and voltage (g) AC frequency (h) AC power metering (j) Suitable CTS for displaying the electrical parameters (v) Safety alarms required in the digital genset controller (a) High engine temperature (b) Low lube oil pressure (c) Low radiator water level (d) Low fuel level (f) under/over speed (vi) Safety trips required in the digital genset controller (a) High engine temperature (b) Low lube oil (D) BASE FRAME : Suitable to couple above engine & alternator made from steet sheel metal (E) FUEL TANK : 8 Hrs capacity with inlet & outlet arrangement, air vent & drain plug arrangement. (F) BATTERY:- One No battery of suitable capcity with battery leads. Note :- DG SET Engine & Alternator should carry warranty for period of 18 months
AVAITION OBSTRUCTION LIGHT: Supply and fix aviation obstruction LED type of Bajaj cat No 110731 BGAV 302 LED, 240 V, with timer switch and contactor inside the enclosure
supply and lay new high density polyethylene DWC pipes of 40mm dia, 6 kgf/sqcm ( For Avaition Obstruction & Dispersal area ligting) including all fittings (bends, Tees, Elbows, sockets, etc) as required on site, complete all as specified and directed. (For cable protection .) Note :- (i) Excavation, return filling and removal of any type of soil/ strata shall be measured and paid separately as items in the CA.
REFRIGERATION & AIR CONDITIONING: Supply only voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 4 KVA.
Supply only voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 1 KVA.
CONDUIT FOR TELEPHONE & TV: S&F TV socket with metal box and top plate complete all as specified and directed.
S & F Telephone socket with metal box and top plate complete all as specified and directed.
INTERNAL ELECTRIC SUPPLY: (Other than Hangar) Supply and fixing LED Exit signage light fitting 3 Watt 230 V AC with 2 hr Battery Back up Make: Bajaj Cat Part No: BESL 03 LED SSD WBB Red/Havells/Wipro/Phillips
Supply and fixing LED Staircase signage light fitting 3 Watt 230 V AC with 2 hr Battery Back up Make: Bajaj Cat Part No: Staircase signage DSDWBB/ Havells/ Wipro/ Phillips
S & F BEE 3 star rated energy efficient BLDC high-speed ceiling fan having 1200 mm blade sweep, air-flow not less than 210 CMM, operating voltage 220-240 V and frequency 50 Hz, including a down road of suitable size and electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fan complete all as specified and directed.
S & F energy efficient non-metallic fresh air fan having blade sweep 250 mm, air delivery not less than 860 CMH, operating voltage 220-240 V and frequency 50 Hz, including electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fresh-air fan complete all as specified and directed.
S & F energy efficient metallic exhaust fan having blade sweep 300 mm, air delivery not less than 900 CMH, operating voltage 220-240 V and frequency 50 Hz, including electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fresh-air fan complete all as specified and directed.
Supply, installation, testing and commissioning of factory made, CPRI type tested, indoor cubical compartmental type LT Panel for Annex I of suitable size, conforming to IEC 61439-1 & 2 and IEC 61641, having both sides open able with hinged double doors and locking arrangement, IP 43 protection made out of 2.0 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labeling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation (1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel vitreous enameled (white) with letters, figures and conventional skull and bones in signal red colour suitable for 3- Phase, 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length and size, including fixing lugs, bolts, screws, etc. complete all as specified and directed by engineer-in-charge.The Panel shall comprise of the following:
[A] BUSBAR CHAMBER [I] 01 Set (3L + N) of copper busbar of rated capacity 400 A, covered with PVC insulated sleeves including insulator, nuts, bolts, etc. with complete connection (B) Incomer - MCCB FP 200 A, 50 KA breaking capacity at 415 V,50Hz conforming to IEC-60942-2, having microprocessor based trip unit, adjustable over load setting (0.7-1 Xia), adjustable short circuit setting (5 - 10 Xire). adjustable neutral protection (N, N/2, OFF), front indication LED,s (ready, overload and pre-alarm)- 01No (C) Outgoing (i) MCCB FP 40A, 30 KA breaking capacity at 415 V, 50 Hz-03 Nos MCCB FP 63 A, 30 KA breaking capacity at 415 V, 50 Hz - 03 Nos (iii) MCB SP 25 Amp, C curve_01 Nos (D) LED Phase indicating lamp RYB - 01 set (E) Digital multifunction meter with KWH & karsh, voltage current, PF functions" (as per shown in drg CE(CG) Goa / Em- Han02- 1036/2022)
S & F MCB for AC applications conforming to IS/IEC 60898-1-2002, having breaking capacity Icon = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, biconvex IP 20 protected lower terminals and sliding shutters, etc. complete all as specified and directed by engineer-in-charge.Make: Schneider, Legrand, Havells 6 A, SP MCB, C- curve
All as as per Item No 29.07 but 16 A, SP MCB, C- curve
All as as per Item No 29.07 but 20 A, SP MCB, C- curve
All as as per Item No 29.07 but 32 A, DP MCB, C- curve
Supply and fix PVC FRLS cable duct fixed on wall with un slotted type non slip cover including with all accessories including fixing plug, cable tie attachment, wire retainer mounting clamp angle/corner duct, channel ports etc with following size. (FOR COMMUNICATION CABLE) 100mmX50mm
All as per item No 29.11 but 32mm x 20mm
All as per item No 29.11 but 32mm x 16mm
INTERNAL WATER SUPPLY: Supply & fixing 15mm dia Two way bib taps (Fancy type), cast copper alloy with crutch or butterfly handle, screwed down,screwed for iron/CPVC pipes complete all as specified.
Supply & fixing of Health faucet with wall hook Make Hindware Model No F160027 or equivalent 15mm dia.
Sewage Treatment Plant: Design, supply, install and commissioning of package type 3KLD STP (Sewage Treatment Plant) including interconnecting pipes, valves, treated water pump, civil works, two nos raw sewage collection tanks with lifting pump of suitable capacity, Bar screen chamber, RCC/ PCC pedestals, Treated water tank of 1 KLD capacity with suitable capacity of pumping facility all as specified and directed. Note: (i) The entire scheme including under ground sewage line and manholes connecting Hangar No 1 & 2 shall be designed and vetted by any NIT/ IIT and approved by Accepting Officer before commencement of work. (ii) Treated water to confirm NGT norms before disposal to the area drainage system
vijay infraprojects pvt ltd
SOOD ASSOCIATES PVT LTD
MC Gandhi and Sons
NSC Projects Pvt. Ltd.
SANKALP INFRACON
NITYA NAND AND SONS CONTRACTORS PVT LTD
B D Raizada Projects Pvt Ltd
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid