Loading…
Loading…
Tender ID
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.3 LAccepted-Finance | L1 | Accepted-Finance loss bidder | |
| 2 | L2₹28.6 L+₹29,156 (1.03%)Rejected-Finance 110059 NEW DELHI NATIONAL CAPITAL TERRITORY OF DELHI 110059 | WEST DELHI | DELHI | 110059 | L2 | Rejected-Finance other than bidder | |
| 3 | L3₹29.6 L+₹1.3 L (4.52%)Rejected-Finance FLAT NO 330 PKT 1 SECTOR 1 DWARKA NEW DELHI 110075 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110075 | L3 | Rejected-Finance other than bidder | |
| 4 | L4₹29.9 L+₹1.5 L (5.43%)Rejected-Finance | L4 | Rejected-Finance other than bidder | |
| 5 | L5₹31.7 L+₹3.4 L (11.9%)Rejected-Finance | L5 | Rejected-Finance other than bidder |
| Sl No | Description | Qty | Unit | V r traders L2 | DEEP ASSOCIATES L9 | The new hut furnitures L3 | M/s VINOD KUMAR SHARMA L8 | Neeraj Enterprises L6 | VEDIT ENTERPRISES L7 | M/S Rohit Enterprises L10 | Shri Balaji Construction L11 | Rohan Construction Company L4 | M/S AADI ENTERPRISES L12 | YASH ENGINEERING L5 | R B ENTERPRISES L1 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches, in any type of soil not exceeding 1.50 metre wide and not exceeding 1.50 metre in depth; for foundation, etc. and getting out complete, all as specified. | 600 | Cum | 100 ₹60,000 | 151 ₹90,600 | 80 ₹48,000 | 120 ₹72,000 | 105 ₹63,000 | 151 ₹90,600 | 110 ₹66,000 | 200 ₹1,20,000 | 80 ₹48,000 | 111 ₹66,600 | 60 ₹36,000 Lowest | 89 ₹53,400 |
| 2.00 | All as per the description of srl item No 1 above but exc 1.50m but not exc 3.00 mtr in depth. | 250 | Cum | 100 ₹25,000 | 161 ₹40,250 | 92 ₹23,000 | 140 ₹35,000 | 160 ₹40,000 | 181 ₹45,250 | 123 ₹30,750 | 150 ₹37,500 | 89 ₹22,250 Lowest | 222 ₹55,500 | 150 ₹37,500 | 89 ₹22,250 Lowest |
| 3.00 | M&L for concrete bed to drain pipe/sewage pipe of any dia including packing under, and haunching against the sides of pipes after they are laid and tested; in cement concrete PCC 1:4 : 8 type D-2 (Using 40mm graded stone agg) including demolition complete all as specified. | 55 | Cum | 1,200 ₹66,000 | 1,044 ₹57,420 | 1,000 ₹55,000 | 1,500 ₹82,500 | 2,000 ₹1,10,000 | 950 ₹52,250 | 1,830 ₹1,00,650 | 1,000 ₹55,000 | 299 ₹16,445 Lowest | 2,222 ₹1,22,210 | 600 ₹33,000 | 799 ₹43,945 |
| 4.00 | M&L for 100mm bore DWCPE pipe as per IS-16098, ISI marked, laid in trenches and jointed, tested including laying complete with collars as per manufacturer instructions including demolition and breaking up old sewage line of any type and any dia set in cement mortar incl demolition of PCC huanching and bedding complete all as specified and directed by Engr-in-Charge | 155 | RM | 300 ₹46,500 | 414 ₹64,170 | 280 ₹43,400 | 400 ₹62,000 | 410 ₹63,550 | 430 ₹66,650 | 413 ₹64,015 | 600 ₹93,000 | 301 ₹46,655 | 500 ₹77,500 | 350 ₹54,250 | 259 ₹40,145 Lowest |
| 5.00 | M&L for 150mm bore DWCPE pipe as per IS-16098, ISI marked, laid in trenches and jointed, tested including laying complete with collars as per manufacturer instructions including demolition and breaking up old sewage line of any type and any dia set in cement mortarv incl demolition of PCC huanching and bedding complete all as specified and directed by Engr-in-Charge | 600 | RM | 300 ₹1,80,000 Lowest | 504 ₹3,02,400 | 400 ₹2,40,000 | 450 ₹2,70,000 | 480 ₹2,88,000 | 520 ₹3,12,000 | 510 ₹3,06,000 | 800 ₹4,80,000 | 412 ₹2,47,200 | 777 ₹4,66,200 | 350 ₹2,10,000 | 379 ₹2,27,400 |
| 6.00 | M&L for 200mm bore DWCPE pipe as per IS-16098, ISI marked, laid in trenches and jointed, tested including laying complete with collars as per manufacturer instructions including demolition and breaking up old sewage line of any type and any dia set in cement mortar incl demolition of PCC huanching and bedding complete all as specified and directed by Engr-in-Charge | 450 | RM | 600 ₹2,70,000 | 644 ₹2,89,800 | 500 ₹2,25,000 | 750 ₹3,37,500 | 725 ₹3,26,250 | 650 ₹2,92,500 | 515 ₹2,31,750 | 1,000 ₹4,50,000 | 649 ₹2,92,050 | 888 ₹3,99,600 | 650 ₹2,92,500 | 479 ₹2,15,550 Lowest |
| 7.00 | M&L for 300mm bore DWCPE pipe as per IS-16098, ISI marked, laid in trenches and jointed, tested including laying complete with collars as per manufacturer instructions including demolition and breaking up old sewage line of any type and any dia set in cement mortar incl demolition of PCC huanching and bedding complete all as specified and directed by Engr-in-Charge | 250 | RM | 700 ₹1,75,000 Lowest | 844 ₹2,11,000 | 802 ₹2,00,500 | 800 ₹2,00,000 | 825 ₹2,06,250 | 801 ₹2,00,250 | 845 ₹2,11,250 | 1,250 ₹3,12,500 | 735 ₹1,83,750 | 1,111 ₹2,77,750 | 800 ₹2,00,000 | 749 ₹1,87,250 |
| 8.00 | Cutting into existing manholes for connecting new drains, of 100mm to 300mm bore pipe, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1, smooth finished, reforming benching as required, complete all as specified. | 50 | Each Job | 100 ₹5,000 | 44 ₹2,200 Lowest | 75 ₹3,750 | 140 ₹7,000 | 120 ₹6,000 | 50 ₹2,500 | 115 ₹5,750 | 100 ₹5,000 | 150 ₹7,500 | 222 ₹11,100 | 200 ₹10,000 | 59 ₹2,950 |
| 9.00 | Demolition of Concrete of any description and in any position not otherwise specifically provided for. | 10 | Cum | 40 ₹400 | 34 ₹340 | 30 ₹300 | 150 ₹1,500 | 135 ₹1,350 | 51 ₹510 | 145 ₹1,450 | 100 ₹1,000 | 100 ₹1,000 | 50 ₹500 | 70 ₹700 | 29 ₹290 Lowest |
| 10.00 | M&L for PCC 1:4:8, Type D-2 using 40mm graded stone aggregate as in foundation filling and mass concrete. | 5 | Cum | 700 ₹3,500 | 1,244 ₹6,220 | 800 ₹4,000 | 1,400 ₹7,000 | 1,325 ₹6,625 | 1,299 ₹6,495 | 1,225 ₹6,125 | 1,500 ₹7,500 | 1,200 ₹6,000 | 1,255 ₹6,275 | 600 ₹3,000 Lowest | 749 ₹3,745 |
Tender Value
₹44 L
EMD Value
₹88,000
Closing Date
21 Feb 2026, 6:00 pmClosed
GE North Delhi Cantt-10
GE North Delhi Cantt-10
REPAIR REPLACEMENT TO TOILET/BATH KITCHEN AND OTHER MISC BR WORKS IN MD ACCN UNDER AGE BR I OF GE NORTH DELHI CANTT10
2026_MES_750718_1
GE/North-124/2025-26
Open Tender
Civil Works
Item Rate
180 days
GE NORTH DELHI CANTT 10
As per NIT
8 documents required · 8 mandatory
₹500
Yes
GE NORTH DELHI CANTT 10
₹88,000
Yes
12 Mar 2026
31 Jan 2026
23 Feb 2026
31 Jan 2026
21 Feb 2026
14 Feb 2026
Excavation in trenches, in any type of soil not exceeding 1.50 metre wide and not exceeding 1.50 metre in depth; for foundation, etc. and getting out complete, all as specified.
All as per the description of srl item No 1 above but exc 1.50m but not exc 3.00 mtr in depth.
M&L for concrete bed to drain pipe/sewage pipe of any dia including packing under, and haunching against the sides of pipes after they are laid and tested; in cement concrete PCC 1:4 : 8 type D-2 (Using 40mm graded stone agg) including demolition complete all as specified.
M&L for 100mm bore DWCPE pipe as per IS-16098, ISI marked, laid in trenches and jointed, tested including laying complete with collars as per manufacturer instructions including demolition and breaking up old sewage line of any type and any dia set in cement mortar incl demolition of PCC huanching and bedding complete all as specified and directed by Engr-in-Charge
M&L for 150mm bore DWCPE pipe as per IS-16098, ISI marked, laid in trenches and jointed, tested including laying complete with collars as per manufacturer instructions including demolition and breaking up old sewage line of any type and any dia set in cement mortarv incl demolition of PCC huanching and bedding complete all as specified and directed by Engr-in-Charge
M&L for 200mm bore DWCPE pipe as per IS-16098, ISI marked, laid in trenches and jointed, tested including laying complete with collars as per manufacturer instructions including demolition and breaking up old sewage line of any type and any dia set in cement mortar incl demolition of PCC huanching and bedding complete all as specified and directed by Engr-in-Charge
M&L for 300mm bore DWCPE pipe as per IS-16098, ISI marked, laid in trenches and jointed, tested including laying complete with collars as per manufacturer instructions including demolition and breaking up old sewage line of any type and any dia set in cement mortar incl demolition of PCC huanching and bedding complete all as specified and directed by Engr-in-Charge
Cutting into existing manholes for connecting new drains, of 100mm to 300mm bore pipe, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1, smooth finished, reforming benching as required, complete all as specified.
Demolition of Concrete of any description and in any position not otherwise specifically provided for.
M&L for PCC 1:4:8, Type D-2 using 40mm graded stone aggregate as in foundation filling and mass concrete.
Brickwork with subclass `B' bricks, straight or curved on plan exc 6m mean radius, built in CM(1:4) incl Dismantling of Brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stone-work and precast concrete articles complete all as specified.
Brickwork with subclass `B' bricks, straight or curved on plan exc 6m mean radius, built in CM(1:4) complete all as specified. (For raising of Existing Man hole Height, etc )
M&L rendering 15mm thick on fair faces of brick surfaces or concrete surfaces and finished surfaces even & smooth without using extra cement in CM 1:4 finished even and smooth including Taking down cement or cement lime plaster, any description on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water etc, including cutting of trees, shrubs or any type of vegitation upto and including roots complete all as specified and as directed by engr-in-charge.
M&L rendering 15mm thick on fair faces of brick surfaces or concrete surfaces and finished surfaces even & smooth without using extra cement in CM 1:4 finished even and smooth complete all as specified and as directed by engr-in-charge.
M&L for Preparing new plastered or old plater/concrete surfaces in any position and applying two coats of white washcomplete all as specified.
Returning filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick each, complete, all as specified.
Removing excavated material up to a distance not exceeding 1.5KM and depositing where directed at a level not exceeding 1.5 metre above the starting point complete, all as specified.
S&F in repair SFRC GT covers with and including frame medium duty of any size 50mm thick factory made and test load 10 tonnes (MD-10), strength as per IS-12592 (2002), ISI marked incl fixing complete to match the road/ floor surface,all as specified by Engr-in-Charge
S&F in repair 80mm thick Manhole/ drain covers of any size with and including frame medium duty factory made and test load 10 tonnes (MD-10), strength as per IS-12592 (2002), ISI marked incl fixing complete to match the road/ floor surface all as specified by Engr-in-Charge
Precast RCC type B-1 (1:2:4), using 20mm graded stone aggregates cover slabs for manholes, septic tank, soakage well, open drains etc. including all mouldings but excluding frame, set in cement mortar (1:4) including demolition of old RCC manhole/drain cover (reinforcement cut as required to facilitate ) complete all as specified.
Mild steel TMT bars 10mm dia and over (and flat iron where quered),cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with theincluding mild steel wire (annealed) not less than 0.9mmdia or securing with clips or welded to flat iron complete all as specified.
Framed work as in opening of manhole and manhole cover of angle iron or other section , also fastening and fixing and welding with MS bars conforming to Fe-410 W Gide E-290,incl painting with two coat of synthetic enamil paint over a coat of red oxide, complete all as specified and as directed.
S&F PVC(SWR) pipes, 75mm external dia double socketed in any length with rubber joints, fixed to walls ( any height)/under floor(any depth) etc with MS clamps including dismantling of cast iron, AC / PVC pipes including all fittings and accessories of any dia and in any position complete all as specified.
S&F PVC (SWR) bends suitable for 75mm external dia with or without access door complete all as specified
S&F PVC (SWR) junction single, (single /double T&Y) equal or unequal with or without access door confirming to IS: 14735, suitable for PVC soil waste discharge pipe of 75mm dia Complete all as specified and as directed.
S&F PVC(SWR) pipes, 110mm external dia double socketed in any length with rubber joints, fixed to fixed to walls ( any height)/under floor(any depth) etc with MS clamps including dismantling of cast iron, AC / PVC pipes including all fittings and accessories of any dia and in any position complete all as specified.
S&F PVC (SWR) bends suitable for 110mm external dia with or without access door complete all as specified
S&F PVC (SWR) junction single, (single/double T&Y) equal or unequal with or without access door confirming to IS: 14735, suitable for PVC soil waste discharge pipe of 110mm dia Complete all as specified and as directed.
S&F in repair Vitreous china wash down water closet pan (pedestal pattern), white including fixing bolts, flushing cistern and flush pipe connection to trap and to flushing pipe inbend cluding provn of cement concrete beading complete all as specified and directed.
M&L non skid ceramic tiles colored tiles 7 to 8mm thick area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm,in floor etc set and jointed in neat cement slurry and pointed in colour cement laid over and including 15mm thick cement mortar screed bed in CM (1:6) including dismantling floor, tiling including cement mortar bedding complete all as specified and directed.
M&L machine pressed precast rubber mould coloured concrete interlocking paver blocks of 60mm thick any shape and size conforming to IS 15658-2006 ,M-35 grade with grey cement and no pigment over 40mm thick Sand filling over 75mm thick PCC 1:3:6 type C-2 using 40mm graded stone aggregate as in sub floor, Sub base, floor inclding demolition of existing PCC/ any type of surface complete all as specified & as directed.
M&L Chequered cement concrete tiles 300mm X 300mm X 25mm thick, set, jointed & pointed in neat cement slurry in floors with grey cement and pigment over screed bed or bedding layers of mortars 15mm thick in CM 1:6 over 75mm thick PCC 1:3:6 type C-2 using 40mm graded stone aggregate as in sub floor, Sub base, floor inclding demolition of existing PCC/ any type of surface complete all as specified & as directed. all as specified and as directed.
M&L for PCC 1:2:4 type B0, using 12.5mm graded agg as in coping, kerbs or mud stops, rounded or chamfered on edges completed as specified.
Construction of Soakage wells of size 1.80 Mtr dia x3.00m depth excavation in any types of soil, foundation in PCC 1:3:6 walls of honeycomb masonry with brick work all as shown in Cdrg No CEDZ- 1124 (R) sheet No 1/1 dated 12.02.2003 & revised upto 14.05.2004, top ring of M-25 concrete including intercepting chamber and screen chamber made of brick masonry in CM, RCC cover slabs in M-25/SFRC covers, interconnecting pipes of RCC/DWC complete filled with brick bats including demolition of existing old soakage well of any size and refill the same up to the existing ground level complete all as as specified and directed complete all as directed.
M&L for cleaning of blocked sewage line, any type of dia in horizontal or vertical position from manhole to manhole drain pipes. Note:- Cleaning of sewage line of any type and dia or bore upto any depth by removing all filts/silts, foreign material and other deposits whatever completely and making the line free from all obstacles and tyesting the flow of sewer line evently, smoothly by filling water. The cleaning operation will be carried out in suitable length by blocking the first and last manhole of sewer line and removing the silt/sludge & deposits out side of defence land in covered van/Trolly all as specified and directed by Engr-in-Charge.rate.
M&L cleaning of chocked sewer line by diesel/petrol runing vehicle mounting hydraulic operated high pressure suction cum jetting sewer cleaning machine fitted with pump having 4000 litres suction capacity and 6000 ltrs water jetting tank including skilled operator, supervisig engineer, labour etc for cleaning and partial desilting of manholes and dechocking of sewer lines of any dia & size and in any description, dechocking and flushing of sewer line from one manholes to another by high pressure jetting system of 2200 PSI for sewer line of following mentioned dia for all depth complete all as specified and directed. Note:- Rates quoted cleaned for 08 hrs of above mentioned machine. Any work carried out throughout 08 hrs shall be measured as one Job.
M&L cleaning of chocked sewer line by diesel/petrol runing vehicle mounting hydraulic operated high pressure suction cum jetting sewer cleaning machine fitted with pump having 8000 litres suction capacity and 10000 ltrs water jetting tank including skilled operator, supervisig engineer, labour etc for cleaning and partial desilting of manholes and dechocking of sewer lines of any dia & size and in any description, dechocking and flushing of sewer line from one manholes to another by high pressure jetting system of 2200 PSI for sewer line of following mentioned dia for all depth complete all as specified and directed. Note:- Rates quoted cleaned for 08 hrs of above mentioned machine. Any work carried out throughout 08 hrs shall be measured as on Job.
Cleaning of sludge from septic tank, soakage well and manhole etc of any capacity and depth by dewatering, taking out mud/ sludge/quid, getting out and removing & depositing the sludge, complete all as specified and directed Note:- septic tank and soakage well be cleaned by Mechanical Vehicle (Tanker) and Dewatering/Sludge to be thrown away outside of defence area.
M&L for Matt finish Exteior wall tiles 8 to 10mm thick & not exc 0.18 sqm , colour & shade of tiles as approved by Engr-in-charge,set and jointed in neat cement slurry and pointed in coloured cement to match the surface etc complete all as specified and directed.
S&F 2mm thick fibre glass reinforced translucent sheeting fixed with proper side lap fixed with coach screw and washer in iron gate,roof,wall etc including dismantling of old sheet of any type complete all as specified and directed.
Design, Manufacture & Supply of factory-made U Shape Drain T-25 - 450 x 450 x 2000mm with T-25 Lid (Drain Cover)-For 450mm with hole made up of high strength precast reinforced cement concrete of M- 50 grade using Fe 500/550D grade TMT steel reinforcement bar. The precast drain is designed considering a wheel load of 5 Tonnes or Axel Load of 10 Tonnes, for vehicle movement and earth pressure.
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.40 MB
Gen124.pdf
Tender Documents • 1.27 MB
BOQ_840794.xls
BOQ • 0.27 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .