ELECT G
13 conditions · 2 needing a document upload
The tenderer must have minimum average annual contractual turnover of "V/N" or "V" whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
The tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i)Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or (ii)Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or (iii)One similar work costing not less than the amount equal to 60% of advertised value of the tender. Similar Nature of Work are as follows for this work:- Supply, installation and commissioning of Solar/Hybrid power panels of capacity more than 1 kWp.
15 conditions · 4 needing a document upload
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
It shall be mandatorily incumbent upon the tenderer to identify, state and submit the supporting documents duly self attested by which they/he is qualifying the Qualifying criteria mentioned in the tender document. It will not be obligatory on the part of tender committee to scrutinize beyond the submitted document of tenderer as far as his qualification for the tender is concerned. The railway reserves the right to verify all statements, information and documents submitted by the bidder in his tender offer, and the bidder shall, when so required by the railway, make available all such information, evidence and documents as may be necessary for such verification. Any such verification or lack of such verification, by the railway shall not relieve the bidder of its obligations or liabilities hereunder nor will it affect any rights of the railway there under.
No post tender correspondence shall be entertained after closing of tender even Suo moto post tender letters of the tenderers shall be treated as null/void.
The tenderers are required to observe the website to find out if any correction slips issued subsequent to uploading of the Tender . Railway reserves the right to make any additions/alterations to the tender uploaded and issue corrigendum to the same effect. In case the tenderer fails to take note of the above corrigendum, the additions and alterations entered/effected in the corrigendum shall be binding upon the tenderer and no claim what so ever will be entertained by Railway.
The tenderer should upload the documents carefully. The documents uploaded by tenderer should be clearly visible and in legible format.
Indian Railways Standard General Conditions of contract 2022 along with correction slips corrected up to date of closing of tender and the attached documents are part of the tender document.
The offers which are incomplete, without supporting documents, unsigned, conditional, will be summarily rejected.
As per letter No. 2022/CE-I/CT/GCC/Correspondence/ New Delhi, dated 14.05.2024 "On IREPS Module , a facility has already been created for online submission of Annexure-V. Therefore, the provision of downloading of Annexure-V of GCC & uploading of physically signed Annexure-V by tenderer had been discontinued on IREPS"
Provision of Solar Power Plants on station service Building& Platforms sheds & residential quarters over JBP Div.
JBP-L-T-No-38-2025~WCR
JBP-L-T-No-38-2025
Open
Works - General
12 Months
Jabalpur, Madhya Pradesh
₹0
₹3.1 L
2 Jan 2026
10 Dec 2025
19 Dec 2025
41 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 3,21,21,147.69 | ||
| — | Item Breakup for | details. | — | ||
| "Design,Engineering, Manufacturingand Supply and Installation and Transportation of Mono-Perc (Monocrystalline) Grid-Tied Roof-Top Solar PV Power PlantSinglephase/ Three phasewith warranty as per detailed specificationandas below for rooftopsofStations, COP, service buildings, residentialbuildings/quarters,LCgates or nominated locations intheJBP divisionwith on line monitoringsystem (I 1inimumplantcapacity 5 KW or above) Note : All materials for the power plant will meetthestandards and warranties as per MNRE.(i)SoIar PVPanels,Mono- Perc Half Cut (Monocrystalline), 540/545/550/570 Wp, ALMM,BIS, IEC61215, IEC61730, ISO 9001Certified. (ii)SoIarOn-GridTie Inverterwith pure sine wave Single Phase / Three PhaseOutput. (iii)Mounting Structure for Solar Panels 175*50"20"2.Smm thick withchemical Anchor Fastening Hight:5.25Feet/7 Feet from Ground with Foundation (iv)ACDB Junction Box. (v)DCDB JunctionBox.(vi)AC Cable in PVC Conduit, ISI Marked. (vii)DC Cable in PVC Conduit, ISIMarked. (viii)Earthing and Lighting Arrestor. (ix)MC-4connectors (x)PVC pipes (xi) Provision of Automatic changeoverwith Current Limiter 30 A /30 A as per detailed specificationwith Provision of MCB Box 4 way (xii)Automatic Water cleaning System with Complete Motor including All other accessories.required aspersitecondition " | — | — | — | 2,74,68,600 | |
| — | Item Breakup for | details. | — | ||
| Supply, commissioning, installation and commissioning of Three phase Net metering of various capacity solar plant including meter set(Both solar meter and net meter and Meter box inclusive of all Discom fes ie.registration fee,feasibility fee,Testing feeand all other charges and accesories/Panel etc. With LT CT/HT CT required at site | — | — | — | 2,29,165.92 | |
| — | Item Breakup for | details. | — | ||
| Supply, installation, testing & commissioning of Single Phase Net Metering of various capacity solar plant including Meter Set (Both Solar Meter and Net Meter) and Meter Box inclusive of all Discom Fees i.e. Registration Fees, feasibility Fees, Testing Fees and all other charges and accessories / panel etc. with LTCT/HTCT required at site . | — | — | — | 1,65,007.74 | |
| — | Item Breakup for | details. | — | ||
| "Layingofcableon wall/pipe/pole/Air includingthings required for fixing(Note: Cable willbe supplied by Railway.) " | — | — | — | 29,275 | |
| — | Item Breakup for | details. | — | ||
| "Excavation of cable trench in cement concrete and laying ofsingle cable (yard/pIatform 50cm. deep and 35cm. wide including re- plaster on surface bycementconcrete after laying of cable.) " | — | — | — | 1,77,234.75 | |
| — | Item Breakup for | details. | — | ||
| Cable laying DOUBLE in earth: This involves Excavation of 1000mm deep trench in soil/hard murrum/tar road/below Railway track. After this the cable shall be laid and then both sides are to be covered with bricks. The rest of the trench to be refilled by sheaved earth. The cable shall be supplied free of cost by Rly's which shall have to be transported by the contractor from Rly. depot,JBP to the site | — | — | — | 1,16,603 | |
| — | Item Breakup for | details. | — | ||
| Provision of HDPE 4 inch HDPE Pipe | — | — | — | 4,42,569.5 | |
| — | Item Breakup for | details. | — | ||
| "Supply, laying, fixing of heavy-duty ISImarked B class GI pipe of 3.65 mm wallthickness&50 mm diameter to be laid along the wallor floor with proper galvanized clamp through the wall or underneath the floor in cement concrete. " | — | — | — | 58,621.5 | |
| — | Item Breakup for | details. | — | ||
| Supply and erection of water storage tank 500 lit of reputed make for pressure maintaining during cleaning of solar plant for solar module plant cleaning system for various capacity of solar plant. | — | — | — | 69,623.6 | |
| — | Item Breakup for | details. | — | ||
| "SETC RACOLD 1000 LPD(Rated Capacity In Litres Per Day)or equivalent Solar water Heating System with Heat Exchanger RACOLD (FPC 1000 LPD) (i)Composite pipe PL-AEPE pipe 2532 type (inner dia. 25Mm & outer dia. 32mm)- Polyethylene HDPE type (UV) pipe with black colour & working temperature of -400 C to 900 C with all suitable fitting of brass & others etc. as per spec. (ii)Composite pipe PL-AEPE pipe 1620 type (inner dia. 16Mm & outer dia 20mm)- Polyethylene HDPE type (UV) pipe with blackcolour & working temperature of -400 Cto 900 C with all suitable fitting of brass & others etc. as per spec. (iii)Provision of brass chrome plated water taps size 15mm 400gram weight along with accessories. (iv)Wiring of sub-main with 2x6 sqmm , single core, multi-stranded FRLS copper wire in PVC conduit concealed/surface and 1.5sqmm , single core, multi-stranded FRLS copper wire for earth wire as per spec (v)Supply, install, testing and commissioning of water pump, capacity, 1 HP as per spec (vi)Pump Control panel single phase ,230V,50Hz with relay range (6.5- 11A) starter for 1.25HP as per spec. (vii) The item includes the supply and installation of up to 30 metres of CPVC piping of suitable diameter, along with all necessary fittings such as tees, elbows, taps, and any other accessories as required at site. The scope further includes the execution of all associated plumbing works, including jhiri cutting, drilling of holes, chasing, and any other ancillary activities necessary for completing the pipeline connection from the outlet of the solar water heate" | — | — | — | 11,08,497.6 | |
| — | Item Breakup for | details. | — | ||
| Supply, fabrication, erection, testing & commissioning of LT power panel 440V outdoor type made of 2mmMS sheet with cover & locking arrangement duly painted with two coat of red oxide & powdercoating (7 process) with requiredaccessories for fixing as per Railways specification attached. The panelshall have Copper Bus Bar of suitable size.(A). Incomingfeeder: (2 x 400 Amps MCCB (B) Out goingfeeder : 2x200 Amp MCCB, 3x100 Amp MCCB and 3x63 Amp including MS channel, Gland, lugs,Suitable Foundation MCCB, Make- ABB, Legrand, L&T, Hager, Schnider, or simillar make | — | — | — | 12,37,320.9 | |
| — | Item Breakup for | details. | — | ||
| Supply of GI perforated cable tray of size 150 mm x 50 mm x 2 mm Thick.Supply of GI perforated cable tray of size150 mm x 50 mm x 2 mm Thick | — | — | — | 1,62,111 | |
| — | Item Breakup for | details. | — | ||
| laying of GI perforated cable tray of size 150 mm x 50 mm x 2 mm Thick.Laying of GI perforated cable tray of size150 mm x 50 mm x 2 mm Thick | — | — | — | 16,209 | |
| — | Item Breakup for | details. | — | ||
| Supply of GI perforated cable tray of size 200 mm x 50 mm x 2 mm Thick.Supply of GI perforated cable tray of size 200 mm x 50 mm x 2 mm Thick | — | — | — | 2,38,658 | |
| — | Item Breakup for | details. | — | ||
| laying of GI perforated cable tray of size 200 mm x 50 mm x 2 mm Thick.Laying of GI perforated cable tray of size 200 mm x 50 mm x 2 mm Thick | — | — | — | 23,866.5 | |
| — | Item Breakup for | details. | — | ||
| Removing, Shafting,relaying of existing cable in trench, wall, soil, roof, track crossing, road crossing,cable tray, etc including MS clamp, nut, bolt, Screw, Nails,gland, lugs.Disconnection, proper reconnection,from panel or any other thing. | — | — | — | 1,41,750 | |
| — | Item Breakup for | details. | — | ||
| "Pucca Cable trench: Construction of cable trench and laying of UG cable in 700 mm deep cable trench made of RCC with MS channel . This includes supply of all materials erection, commissioning of cable & trench etc. The laying of cable from transformer to the panel board shall be done in cable trench made of RCC complete with excavation of soil, construction of RCC wall for a height of 700 mm and inside width of 500 mm. Both wall and bottom surface of inside trench shall be finished with a fine coating of plaster. This constructed cable trench shall be covered with concrete slabs each of requisite width and a length of 1m." | — | — | — | 1,38,813 | |
| — | Item Breakup for | details. | — | ||
| Provision of maintenancefree earthing. | — | — | — | 1,79,179.2 | |
| — | Item Breakup for | details. | — | ||
| Supply & erection of GI earth strip 30/25 x 5 mm | — | — | — | 1,637 | |
| — | Item Breakup for | details. | — | ||
| "Supply and Installation of Tap off Boxes type - PIBX-C-400 with provision of MCCB and fitted with C&S or similar make 4 Pole 250 A MCCB Thermal setting 80-100% In, All MCCBs should have an Adjustable setting range (In) from 70% to 100%, & Ics=100%Icu Each MCCB should have extended rotary handle for easy operation.The manufacturer should also submit all the test certificates in accordance IEC 61439 with Make- Legrand, C&S, ABB or similar, complete in all respect & as per railway requirement. complete in all respect as per instructions by site engineer" | — | — | — | 1,16,404.48 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
AC08to10.pdf
ATTACHMENT
GCCcorrectionslips.pdf
ATTACHMENT
38-2025tenderdoc_5.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .