Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.7 CrAccepted-AOC | ₹2.7 Cr Quoted ₹2.4 Cr | L1 | Accepted-AOC The Lowest and negotiated tenderer |
| 2 | L2₹2.4 Cr+₹2.8 L (1.17%)Rejected-Finance | ₹2.4 Cr+₹2.8 L (1.17%) | L2 | Rejected-Finance Unsuccessful tenderer |
| 3 | L3₹2.6 Cr+₹18.3 L (7.67%)Rejected-Finance | ₹2.6 Cr+₹18.3 L (7.67%) | L3 | Rejected-Finance Unsuccessful tenderer |
| 4 | L4₹2.7 Cr+₹32.6 L (13.7%)Rejected-Finance | ₹2.7 Cr+₹32.6 L (13.7%) | L4 | Rejected-Finance Unsuccessful tenderer |
| 5 | L5₹2.9 Cr+₹50.1 L (21.0%)Rejected-Finance | ₹2.9 Cr+₹50.1 L (21.0%) | L5 | Rejected-Finance Unsuccessful tenderer |
Tender Value
Refer Docs
EMD Value
₹2.0 L
Closing Date
9 Jan 2021, 6:00 pmClosed
SUPERINTENDING ENGINEER, TNPHC LTD, NORTH CIRCLE.
O/o the Superintending Engineer/North Circle No.1 and 7, Inspectors quarters, PGR Line, Behind CPO Building, Annadhanapatty, Linemedu, Salem - 636 006.
Construction of 32 Nos. of PC/HC Quarters at Kumarapalayam in Namakkal District
2020_TNPHC_189452_1
SE/NC/DB/1731/2020
Open Tender
Civil Works
Lump-sum
300 days
Kumarapalayam in Namakkal District
Construction of 32 Nos. of PC/HC Quarters at Kumarapalayam in Namakkal District
8 documents required · 8 mandatory
₹0
₹2.0 L
27 Feb 2021
29 Dec 2020
11 Jan 2021
29 Dec 2020
9 Jan 2021
29 Dec 2020
Amount
1.1 : Earth work excavation in all soils (including refilling) a. 0 to 2 mt.
1.3 : Earth work excavation in Soft disintegrated rock (including refilling) a. 0 to 2 mt.
13.1 : Filling with Excavated Earth
21.2 : Teak wood Wrought & Put up a. T.W. over 2 m & below 3 m
b. T.W. below 2 m length.
23.3 : S&F of Magnetic door catches
24 : Manufacturing & supply of steel windows (Weight basis)
25 : M.S.Holdfast
30 : Ellispattern
31 : Weathering couse
37.1 : White washing 3 coats (slaked)
39 : M.s Grills
40 : Painting - New "wood work"
41 : Painting - New "iron work"
52 : PVC Water supply (ASTM) a. 32 mm dia
b. 25 mm dia
52.1 : Supplying and fixing of 20mm dia "B" Class GI pipe for Hot water line (Fully Concealed in walls)
Electrical arrangements 69 : 15 Amp. Power plug
72 : Box type Fibre Fan hook
76 : 8 SWG wire
77.3 : S&F of TV/Telephone line Socket
77.4 : S&F of 20mm dia PVC pipe for TV/Telephone line
78 : Earthing Station IS3043 (Type I)
86 : Anti termite treatment
ANNEXURE 2.1.2 : Supplying and filling with Gravel
2.1.3 : Supplying and Filling crushed stone sand
3.1.1 : C.C.1:5:10 for Foundation & Basement (using crushed stone sand)
6.2.1 : Brick work in C.M. 1:5 (F& B) using chamber Burnt bricks of size 23 x 11.4 x 7.5 cm (9" x 4 1/2"x 3") (using crushed stone sand)
8.1.1.1 : Standardised concrete Mix M20 Grade concrete. (using crushed stone sand) a) In Foundation and Basement.
b) In Ground Floor
c) In First Floor.
d) In Second Floor.
e. In Third Floor
f. In Fourth Floor
9.2.1 : Brick work in C.M. 1:6 using chamber Burnt bricks of size 23 x 11.4 x 7.5 cm (9" x 4 1/2"x 3") (using crushed stone sand) a. In Ground Floor/Stilt floor
b. In First Floor
c. In Second Floor
d. In Third Floor
e. In Fourth Floor
10.2.1 : Brick partition work in C.M. 1:4 using chamber Burnt bricks of size 23 x 11.4 x 7.5 cm (9" x 4 1/2"x 3") 114 mm tk (B.P.) (using crushed stone sand) b. In Ground Floor/Stilt floor
c. In First Floor
d. In Second Floor
e. In Third Floor
f. In Fourth Floor
11.2.1 : Brick Partition work in C.M. 1:4 using chamber Burnt bricks of size 23 x 11.4 x 7.5 cm (9" x 4 1/2"x 3") 75 mm tk (B.P.) (using crushed stone sand) a. In Ground floor
b. In First floor
c. In Second Floor
d. In Third Floor
12.1.1 : Brick partition work in C.M. 1:4 using country bricks of size 22 x11x5cm 50 mm thick (using crushed stone sand) a. In Ground floor
b. In First floor
c. In Second Floor
d. In Third Floor
14.1.1.I : Precast Cupboard slab 20 mm tk using standardised concrete mix M20 grade.(using crushed stone sand) a. In Ground floor
b. In First floor
c. In Second Floor
d. In Third Floor
14.1.1.II : Precast cupboard slab 40 mm tk using standardised concrete mix M20 grade.(using crushed stone sand) a. In Foundation & basement
b. In Ground Floor
c. In First Floor
d. In Second Floor
e. In Third Floor
16.1.1 : Precast Jally Ventilator 50mm thick.Using standardised M20 grade concrete Mix. (using crushed stone sand) a. In Ground Floor
b. In First Floor
c. In Second Floor
d. In Third Floor
e. In Fourth Floor
18.1 : Formwork using M.S.Sheet a.For Column footings,plinth beam,Grade beam,Raftbeam,Raft slab etc.,
b.Plain surfaces such as Roof slab,floorslab,Beams,lintels,lofts,sill slab,staircase,portico slab and other similar works
c.For Square and rectangular columns and small quantities
21.6.1 : R.C.C.Door frames of size 100 x 75mm with one edge grooves size 't' x 20 mm using standardised concrete mix M20 grade. (using crushed stone sand) a. 900 x 2100mm
26.1 : Flooring in C.C.1:5:10 (using crushed stone sand)
28.1 : Floor plastering in C.M. 1:4, 20 mm tk. (using crushed stone sand)
29.8.1 : Glazed tiles using Grout (Tile Joint Filler) (using crushed stone sand)
29.9.1 : Floor ceramic tiles using Grout (Tile Joint Filler) (antiskid) (using crushed stone sand)
33.1 : Plastering in C.M. 1:5, 12 mm tk. (using crushed stone sand)
34.1 : Plastering in C.M. 1:4, 12 mm tk.(using crushed stone sand)
35.1.2 : Spl. Ceiling plastering in C.M. 1:3, 10 mm tk. (using crushed stone sand)
36.1 : Cement mortar Border in C.M. 1:5, 12 mm tk. (using crushed stone sand) a. 150 mm wide
b. 75 mm wide
c. 50 mm wide
38.6 : One coat white cement for new walls and other similar works.
43.1 : Supply & Fabrication of Mild steel / RTS grills (without cement slurry) for all sizes of rods.
44.2.1 : Rain water harvesting using defunct borewell and providing perforated cover slab a). Providing pit (M20)
b) Augering 30cm dia
44.6 : PVC SWR 110 mm dia with ISI mark type- A for Rain water down fall pipe
52.4 : 20mm dia PVC water supply ASTM pipe (fully consealed in walls)
53.5 : Wash Hand Basin without pedastal of size 550 x 400 mm
56.3.2: S&F of Indian Water Closet white glazed (Oriya type) of size 580 x 440mm with PVC SWR grade P' or "S' trap - In G.F.(using crushed stone sand)
56.4.2: S&F of Indian Water Closet white glazed (Oriya type) of size 580 x 440mm with PVC SWR grade P' or "S' trap - other than G.F.(using crushed stone sand)
58.3 : PVC SWR pipe (Soil line) with ISI mark - type 'B'. a. 110 mm dia.
b. 75 mm dia.
58.4 : Supplying, Laying & Concealing the 50mm dia PVC ( SWR) pipe with ISI mark type - 'B' with relevant specials.
59.2.1 : Gully Trap using chamber Burnt bricks of size 23 x 11.4 x 7.5 cm (9" x 4 1/2"x 3") (using crushed stone sand)
60.1 : PVC Nahani trap (4way/2way)
61.3 : UPVC Non Pressure pipe of SN8 SDR 34 (S 16.5) as per IS 15328/2003 a. 110 mm UPVC Non Pressure pipe
b. 160 mm UPVC Non Pressure pipe
62.1.1 : PVC Specials as per IS 10124/1982 Part II a. 110 mm dia PVC bend
b. 160 mm dia PVC bend
62.2.2 : PVC Equal Tee as per BIS 7834/1975 a. 110 mm dia PVC Equal tee
b. 160 mm dia PVC Equal tee
64.1 : Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990. a. Light point with ceiling rose
b. Light point without ceiling rose
c. Calling bell point with Buzzer/Calling bell
65.1 : Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990 for Fan point.
66.1 : Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990 for Staircase Light Point.
67.1 : Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990 for 5 amps 5 pin plug socket point @ Switch Board Itself.
68.2 : Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990 for 5 amps 5 pin plug socket point @ Convenient Places.
77.2.1 : S & F of 20 amps DP plug & Socket in sheet enclosure with 32 A DP MCB in flush wall with earth connection(For AC Plug) superior variety
77.6 : Run of 2 Wires of 4 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990.
77.7 : Run of 2 Wires of 2.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990.
77.8 : Run of 4 Wires of 4 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990.
79.3 : Providing 3 nos of 200 amps 500 volt fuse unit
87.1 : Supplying and fixing of Three phase ELCB/RCCB
98.3.1 : TW panelled single leaf door shutter (with brass fittings) a. 1000 x 2100mm. (Single leaf)
105.1 : Run off 4 x 4 Sq mm copper PVC insulated unsheathed single core cable for 3 phase EB service connection.
361.5.1: Vitrified Tiles flooring (ivory) (using crushed stone sand)
367 : Providing wooden (melamine) polish for new wood
379.4.2.1 : Granite slab 18-20mm thick (Jet black) for Kitchen arrangements. a. In Ground Floor
b. In First Floor
c. In Second Floor
d. In Third Floor
383: S&F of Cuddapah sink 600 x 600 x 200mm
448.2: Supply and fixing 32mm dia PVC Tee with end cap
799 : Two coat of OBD over one coat white cement for inner walls
826 : Removing hard rock by wedging chiseling and Trimming to proper shape where blasting is prohibited
827 : Drilling hole in hard rock 32mm dia for foundation and filling with CM 1:2
P SELLAPPAGOUNDER
SAAM Construction
j.v constructions
chendur construction company
J C ENGINEERING CONSTRUCTION COMPANY
GRG Builders
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .