Tender Value
₹98.6 L
EMD Value
₹2.0 L
Closing Date
16 Apr 2025, 3:00 pmClosed
XEN M/GARH W.S MECH. DIVISION, NARNAUL
Executive Engineer M/Garh W.S. Mech. Divn., Narnaul, 123001
Supply of new 5 Cs. and 10 Cs. Pumps with allied electro-mechanical accessories for flood protection work under flood scheme 2024-25 in W.S. Mech. Division, Narnaul.
2025_HRY_437945_1
1965-79/9-A Dated 28.03.2025
Open Tender
Pumps/Motors
Works
180 days
XEN M/GARH W.S MECH. DIVISION, NARNAUL
Please refer Tender documents.
3 documents required · 3 mandatory
₹5,000
₹2.0 L
Yes
14 May 2025
2 Apr 2025
17 Apr 2025
2 Apr 2025
16 Apr 2025
2 Apr 2025
Amount
Supply of 10 Cs existing V.T. axial flow pump including MS Delivery pipe, bend & support of bend as per site requirement & specification approved by technical committee
Supply of induction motors of 60 HP Solid Shaft suitable for 10 Cs VT axial flow pumps, 45 KW, 1440RPM, 440/415V voltage, 3 phase, 50 Hz bearing SKF / FAG as per specifications .)
Supply of 5 Cs existing V.T. axial flow pump including MS Delivery pipe, bend & support of bend as per site requirement & specification approved by technical committee
Supply of induction motors of 40 HP Solid Shaft suitable for 5 Cs VT axial flow pumps, 45 KW, 1440RPM, 440/415V voltage, 3 phase, 50 Hz bearing SKF / FAG as per specifications .)
Supply of fully automatic ATS Starter suitable for 60 HP motor with suitable contactor for main transformer/start, interlinking bus bar of suitable size with degree of protection IP-54 complete with small items like air cooled ATS thimbles, nuts & bolts, lugs etc with stand of MS angle (50x50x6 mm) of 1 feet height of floor level with allied accessories along with supply of inbuilt capacitor bank 12 Kvar, 30 meter 95 Sqmm 3 core cable for each starter, as per approved technical specification
Supply of fully automatic ATS Starter suitable for 40 HP motor with suitable contactor for main transformer, interlinking bus bar of suitable size with degree of protection IP-54 complete with small items like air cooled ATS thimbles, nuts & bolts, lugs etc with stand of MS angle (50x50x6 mm) of 1 feet height of floor level with allied accessories along with supply of inbuilt capacitor bank 10 Kvar, 30 meter 70 Sqmm 3 core cable for each starter, as per approved technical specification
Supply of LT Armoured PVC Alluminum cable of size 185 sqmm 3 core confirming to IS 7098-1995 as per approved make
Supply of LT Armoured PVC Alluminum cable of size 95 sqmm 3 core confirming to IS 7098-1995 as per approved make
Supply, Erection & Commissioning of M.S delivery Pipe 341.4 mm inner dia made of 6 mm thick MS Plate both end flanged (in >= 6 Mtr Pieces) as per approved specification & Make. (Including SS Nut & Bolt, Rubber Sheet 1/8" & other fitment accessory required)
Supply, Erection & Commissioning of M.S delivery Pipe 258.9 mm inner dia made of 6 mm thick MS Plate both end flanged (in >= 6 Mtr Pieces) as per approved specification & Make. (Including SS Nut & Bolt, Rubber Sheet 1/8" & other fitment accessory required)
ace marketing pvt ltd (BID ID -1241955)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .