| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.3 CrAccepted-AOC | ₹1.3 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹1.6 Cr+₹32.3 L (25.7%)Rejected-Finance | ₹1.6 Cr+₹32.3 L (25.7%) | L2 | Rejected-Finance Rejected |
| Sl No | Description | Qty | Unit | V MISSION L2 | VAIBHAVLAXMI L1 |
|---|---|---|---|---|---|
| 1.00 | Supplying, installing, testing & commissioning Digital
(Hybrid) type EPABX of 6 x 16(2 Digital+14 Analogue)
extension complete. | 1 | Nos | 65,000 ₹65,000 | 41,500 ₹41,500 Lowest |
| 2.00 | Supplying and erecting Electronic Type cordless call bell erected on T.W. board having portable bell push working on 9V. D.C.battery and (Effective range upto 45 meter) bell on 250 V A.C. supply. | 4 | Nos | 650 ₹2,600 | 450 ₹1,800 Lowest |
| 3.00 | Supplying and fixing24 port Patch Panel with tool-less
keystone jacksin provided U Rack complete as per
specification no.WG-NAS/PP | 1 | Nos | 12,500 ₹12,500 | 11,000 ₹11,000 Lowest |
| 4.00 | Supplying & installing UTP networking cat-6 armoured cable suitable for LAN / WAN Computer net-working as per specification No. WG-COC/NC | 200 | Mtrs | 165 ₹33,000 | 130 ₹26,000 Lowest |
| 5.00 | Supplying and fixing 9U Wall Mount Rack (Dimension-
DxWXH - 450X550X500 mm) as per specification in
approved manner | 1 | Nos | 11,500 ₹11,500 | 8,500 ₹8,500 Lowest |
| 6.00 | Supplying and fixing High Performance Manageable Wireless N Selectable Dual band Access Point w PoE in WLAN network as per specification no. WG-NAS/LAP2 | 1 | Nos | 45,000 ₹45,000 | 25,000 ₹25,000 Lowest |
| 7.00 | Supplying, fixing, and configuring Media Convertor
1000Base-T to 1000Base-SX SC Multi-mode Media
Converter (550m) | 1 | Nos | 14,500 ₹14,500 | 11,500 ₹11,500 Lowest |
| 8.00 | Supplying and fixing Power over Ethernet Adaptorto provide DC supply to Ethernetdevices as per specification No.WG-NAS/PEA | 1 | Nos | 6,500 ₹6,500 | 4,000 ₹4,000 Lowest |
| 9.00 | Supplying & installing Single Mode Fibre Patch Cord Patch
Cords -3 m – Duplex | 1 | Nos | 1,450 ₹1,450 | 1,250 ₹1,250 Lowest |
| 10.00 | Supplying, fixing, and configuring48 Ports Managed Gigabit
Switches Layer-2 48 10/100/1000Base-T ports L2+
Management Switch with 4 10GE SFP+ ports | 1 | Nos | 2,50,000 ₹2,50,000 | 1,65,000 ₹1,65,000 Lowest |
Tender Value
₹1.2 Cr
EMD Value
₹2.4 L
Closing Date
23 Oct 2023, 5:00 pmClosed
Member Secretary
GSUDA
Construction of New Administrative Building in Sy no. 501/1 and 502/3 at Pernem for Pernem Municipal Council. SH-Electrical work, Phase I.
2023_GSUDA_11577_1
F.43/3/GSUDA/E-TENDER/34/1304
Open Tender
Electrical Works
Item Rate
180 days
pernem
Please refer Tender documents.
3 documents required · 3 mandatory
₹8,000
₹2.4 L
29 Jul 2026
29 Sept 2023
24 Oct 2023
29 Sept 2023
23 Oct 2023
29 Sept 2023
Amount
Supplying, installing, testing & commissioning Digital (Hybrid) type EPABX of 6 x 16(2 Digital+14 Analogue) extension complete.
Supplying and erecting Electronic Type cordless call bell erected on T.W. board having portable bell push working on 9V. D.C.battery and (Effective range upto 45 meter) bell on 250 V A.C. supply.
Supplying and fixing24 port Patch Panel with tool-less keystone jacksin provided U Rack complete as per specification no.WG-NAS/PP
Supplying & installing UTP networking cat-6 armoured cable suitable for LAN / WAN Computer net-working as per specification No. WG-COC/NC
Supplying and fixing 9U Wall Mount Rack (Dimension- DxWXH - 450X550X500 mm) as per specification in approved manner
Supplying, fixing, and configuring Media Convertor 1000Base-T to 1000Base-SX SC Multi-mode Media Converter (550m)
Supplying and fixing Power over Ethernet Adaptorto provide DC supply to Ethernetdevices as per specification No.WG-NAS/PEA
Supplying & installing Single Mode Fibre Patch Cord Patch Cords -3 m – Duplex
Supplying, fixing, and configuring48 Ports Managed Gigabit Switches Layer-2 48 10/100/1000Base-T ports L2+ Management Switch with 4 10GE SFP+ ports
Supplying, installing and activating physical license pack software for supporting 32 additional APs on DWS-2000 complete.
Supplying and drawing of Cat - 6 UTP, 4 pair annealed tinned copper conductor PVC insulated, PVC sheathed, unarmoured data cable in existing surface/recessed steel/PVC conduit of appropriate size including connection, etc. complete as required.
Supplying and drawing/fixing indoor type 0.5 sq.mm FR PVC insulated copper conductor unarmoured telephone cable ITD/DOT approved, with GI saddles on wal or in the existing surface/recesed steel/PVC conduit having folowing pair(s), complete as required. (2 pair )
Supplying, installing, testing and commissioning of Junction Box, ITD/DOT approved, indoor type with wall mounting/concealed facility having front door with lock along with aluminium frame for mounting disconnection type Krone modules, complete cabinet fabricated from 18 SWG CRCA sheet with powder coating in appropriate manner and suitable for following capacity of pairs, including Krone makemodules, crimping and terminations, etc. complete as required. © 50 pair
Supplying, installation and testing of suitable size modular GI box , modular plate and cover complete with RJ-11 connector(modular telephone socket) including concealed metal box/surface GI/PVC Box, modular plate, punching, identifying, complete as required.
Supplying, installation and testing of suitable size modular GI box , modular plate and cover complete with RJ-45 connector(modular LAN socket TX1000/ CAT6) including concealed metal box/surface GI/PVC Box, modular plate, punching, identifying, complete as required.
Supplying and erecting LED square / circular 13 to 15W downlighterhaving pressure die-cast aluminum housing, opal translucent cover, mounting arrangement with board for surface type or spring loaded mounting clips for flush type complete.
Supply and erecting of 9 inch (225 mm sweep) exhaust fan with double ball bearings, 1400 rpm, complete with all accessories.
Supplying & erecting inverter LED batten 20W tube light fitting with polycarbonate housing, heat sink, integrated HF electronic driver, Min. 2600 mAh Lithium ion Battery with charging time of 8-10 Hours and backup time of Min. 3 hrs. with minimum 25% of initial Watts having luminous efficacy of 100 lumen/watt, CRI>80, CCT of 6500K and THD<=20% having useful life of minimum 25000 hrs. with overheating protection with 2 years warranty.
Supply and erecting of 48 inch ( 1200mm sweep) ceiling fan, double ball bearing type, , complete with all accessories. CAT A
Supplying and erecting LED Panel Light(600mm X 600mm) Max. 35 W having CRCA powder coated housing, polystyrene diffuser having system lumens output of Min 4200 Lumens, min. efficacy of 120 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50 including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warrant
Supply of 4 core armoured PVC/XLPE insulated, PVC sheathed aluminium conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I) ,IS:7098(Part I) with latest amendments of following size. (5) 4 Core 16 sq.mm
Supply of 3 1/2 core armoured PVC/XLPE insulated, PVC sheathed aluminium conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I) ,IS:7098(Part I) with latest amendments of following size. (1) 3 1/2 Core 25 sq.mm
'Supply of 3 1/2 core armoured PVC/XLPE insulated, PVC sheathed aluminium conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I) ,IS:7098(Part I) with latest amendments of following size. (4) 3 1/2 Core 70 sq.mm
Supply of 3 1/2 core armoured PVC/XLPE insulated, PVC sheathed aluminium conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I) ,IS:7098(Part I) with latest amendments of following size. '(5) 31/2 Core 95 sq.mm
'Supply of 3 1/2 core armoured PVC/XLPE insulated, PVC sheathed aluminium conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I) ,IS:7098(Part I) with latest amendments of following size. (6) 31/2 Core 120sq.mm
'Supply of 3 1/2 core armoured PVC/XLPE insulated, PVC sheathed aluminium conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I) ,IS:7098(Part I) with latest amendments of following size. (10) 3 1/2 Core 300 sq.mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of size not exceeding 25 sq.mm in the existing RCC/HUME/STONEWARE Metal pipe, etc. complete as required.
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size not exceeding 25 sq.mm in the existing masonry open duct, etc. complete as required
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size not exceeding 25 sq.mm on surface, etc. complete as required
Supply of following size of 3 core, HV, 11 KV grade, ISI mark, XLPE cable with stranded compact circular aluminium conductor, conductor screened with extruded semiconducting compound, XLPE insulated, insulation screned with extruded semiconducting compound in combination with copper tape(0.3 KA for 1Sec.) cores laid off,inner sheath of PVC tape,galvanised steel flat strip armoured and overall PVC sheathed cable conforming to IS:7098(Part II) with latest amendments. '(7)' 3 Core 150 sq.mm
Supply of following size of 3 core, HV, 11 KV grade, ISI mark, XLPE cable with stranded compact circular aluminium conductor, conductor screened with extruded semiconducting compound, XLPE insulated, insulation screned with extruded semiconducting compound in combination with copper tape(0.3 KA for 1Sec.) cores laid off,inner sheath of PVC tape,galvanised steel flat strip armoured and overall PVC sheathed cable conforming to IS:7098(Part II) with latest amendments. ' (9) 3 Core 300sq.mm
'Laying of one number PVC insulated and PVC sheathed/XLPE power cable of grade exceeding 11 KV but not exceeding 33 KV grade of size exceeding 120 sq.mm but not exceeding 400 sq.mm direct in ground including excavation in the form of a trench as per Cable Trench Drawing provided by the Engineer-Incharge,sand cushioning with screened sand bed of 20mm thick , protective covering with bricks placed lenghtwise on top of cable all over the run and backfilling the excavated earth without stones or hard material and making the surface proper with 15 cm crown on the top complete as required. (a) Soily strata
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of grade exceeding 11 KV but not exceeding 33 KV grade of size exceeding 120 sq.mm but not exceeding 400 sq.mm direct in ground including excavation in the form of a trench as per Cable Trench Drawing provided by the Engineer-Incharge,sand cushioning with screened sand bed of 20mm thick , protective covering with bricks placed lenghtwise on top of cable all over the run and backfilling the excavated earth without stones or hard material and making the surface proper with 15 cm crown on the top complete as required. (b)Rocky strata
'Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size exceeding 120 sq.mm but not exceeding 400 sq.mm direct in ground including excavation in the form of a trench as per Cable Trench Drawing provided by the Engineer-Incharge,sand cushioning with screened sand bed of 20mm thick , protective covering with bricks placed breadth-wise on top of cable all over the run( the brick protection shall cover the cable and project atleast 5 cms over the sides of the cable)and backfilling the excavated earth without stones or hard material and making the surface proper with 15 cm crown on the top complete as required. (a) In soily strata
Laying of one number PVC insulated and PVC sheathed/XLPE power cable 1.1 KV grade of size exceeding 120 sq. mm but not exceeding 400 sq. mm on surface, etc complete as rewquired
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size exceeding 25 sq.mm but not exceeding 400 sq.mm in the existing masonry open duct, etc. complete as required.
Laying of one number PVC insultaed and PVC sheathed/XLPE power cable of 1.1 KV grade of size exceeding 25 sq. mm but not exceeding 120 sq. mm in the existing masonry open duct etc. complete as required
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size exceeding 25 sq.mm but not exceeding 120 sq.mm direct in ground including excavation in the form of a trench as per Cable Trench Drawing provided by the Engineer-Incharge,sand cushioning with screened sand bed of 20mm thick , protective covering with bricks placed breadth-wise on top of cable all over the run( the brick protection shall cover the cable and project atleast 5 cms over the sides of the cable) and backfilling the excavated earth without stones or hard material and making the surface proper with 15 cm crown on the top complete as required. In rocky strata
'Supplying and making cable end terminations with brass compression gland and copper lugs for folowing sizes of 4 Core PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required. (5) 4 x 16 Sq. mm.
Supplying and making cable end terminations with brass compression gland and copper lugs for folowing sizes of 3 1/2 Core PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required. '(1) 3 1/2 x 25 Sq. mm.
Supplying and making cable end terminations with brass compression gland and copper lugs for folowing sizes of 3 1/2 Core PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required. '(4) 3 1/2 x 70 Sq. mm.
Supplying and making cable end terminations with brass compression gland and copper lugs for folowing sizes of 3 1/2 Core PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required. '(5) 3 1/2 x95 Sq. mm.
Supplying and making cable end terminations with brass compression gland and copper lugs for folowing sizes of 3 1/2 Core PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required. '(6) 3 1/2 x120 Sq. mm.
Supplying and making cable end terminations with brass compression gland and copper lugs for folowing sizes of 3 1/2 Core PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required. '(10) 3 1/2 x 300 Sq. mm.
Supplying and Installing following size perforated type 16 SWG, M.S.cable tray of GI pregalvanised/hot dip galvanised/ powder coated finish, in convenient sections, joined with connectors, suspended from the ceiling with suitable MS suspenders including bolts and nuts, painting suspenders etc, complete as required. (b) 150mm width x 50mm depth
Supplying and Installing following size perforated type 16 SWG, M.S.cable tray of GI pregalvanised/hot dip galvanised/ powder coated finish, in convenient sections, joined with connectors, suspended from the ceiling with suitable MS suspenders including bolts and nuts, painting suspenders etc, complete as required.(D) 600mm width x 50mm depth
Earthing with copper earth plate 600 mm x 600 mm x 3 mm thick including accessories and providing masonry enclosure with CI/RCC cover having locking/lifting arrangement and watering pipe etc. (but without charcoal or coke and salt) as required as per the Earthing Drawing provided by the Engineer-Incharge.The scope of work includes the following: a) Excavation of pit of size 1.0x1.0x 3.0 mtrs(min) and disposal of excavated soil. c)Watering GI pipe, 20 mm Class B, with funnel as per specs. d) Charcoal/salt as per specs ( paid seperately). e) Refilling the pit of size 1.0x1.0x 3.0 mtrs(min) with soft black agriculture soil of minimum resistivity i/c transportation. e)Masonary chamber with proper foundation, cover plate and locking arrangement. f) Testing of earth value with earth megger and certifications of its value. g)watering arrangement(plumbing will be paid seperately).
Earthing with GI earth plate 600 mm x 600 mm x 6 mm thick including accessories and providing masonry enclosure with CI/RCC cover having locking/Lifting arrangement and watering pipe etc. (but without charcoal or coke and salt) as required as per the Earthing Drawing provided by the Engineer-Incharge.The scope of work includes the following: a) Excavation of pit of size 1.0x1.0x 3.0 mtrs(min) and disposal of excavated soil. c)Watering GI pipe, 20mm, Class B, with funnel as per specs. d) Charcoal/salt as per specs ( paid seperately). e) Refilling the pit of size 1.0x1.0x 3.0 mtrs(min) with soft black agriculture soil of minimum resistivity i/c transportation. e)Masonary chamber with proper foundation, cover plate and locking arrangement. f) Testing of earth value with earth megger and certifications of its value. Aluminium tag with embossed earthing value to be attached to the pipe.g)watering arrangement(plumbing will be paid seperately).
Providing and fixing 25 mm x 5 mm copper strip on surface r in recess for coneections etc. as required
Providing and fixing 25 mm x 5 mm GI strip on surface or in recess for coneections etc. as required
Providing and fixing 4 mm dia copper wire on surface or in recess for loop Earthing . as required
Providing and fixing 6 SWG dia GI wire on surface or in recess for loop Earthing . as required
Extra for using salt and charcoal for GI or copper plate earth electrode as required( 96 Kgs of Charcoal and 5 Kgs of Salt)
Supplying, erecting, testing & commissioning 11kV, 630A, 21kA/3sec, 4 way outdoor, extensible motorised SCADA compatible RMU, internal arc tested consisting of 2 nos. feeder with 2 LBS and 2 nos. feeder with 2 VCB compliant to IEC 62271 -100, 200 and 102, as per specification no. SW-HTS/RMU SCADA
Supplying, erecting, testing & commissioning 11kV, 630A, 21kA/3sec, 1 way indoor/outdoor, extensible motorised SCADA compatible RMU, internal arc tested consisting of 1 no. feeder with 1 VCB compliant to IEC 62271 -100, 200 and 102, as per specification no. SW-HTS/RMU SCADA
'Supplying and making Indoor cable end termination with heat shrinkable kit for following sizes of PVC insulated PVC sheathed/XLPE aluminium conductor cable upto 11 KV grade, complete as required. (c) 11 KV, 3 Core x 120 - 185 sq.mm
Supplying and making Indoor cable end termination with heat shrinkable kit for following sizes of PVC insulated PVC sheathed/XLPE aluminium conductor cable upto 11 KV grade, complete as required. '(d) 11 KV, 3 Core x 240 - 300sq.mm
'Supplying and making Outdoor cable end termination with heat shrinkable kit for following sizes of PVC insulated PVC sheathed/XLPE aluminium conductor cable upto 11 KV grade, complete as required. (d) 11 KV, 3 Core x 240 - 300sq.mm
Supplying and Erecting approved make 200 kVA,3 phase, 50c/s Oil immersed and naturally cooled outdoor type,Copper wound transformer with Energy Efficiency Level -2 ,BIS Standard with delta connected. on HV side & star connection on LV side with additional neutral brought out on load side,Temp rise should not Exceeding 4000 C by thermometer in oil and 4500C by the resistance in winding at full load rating,voltage rating 11/0.433 kV with HV tapping(with off load tap changer) Tappings on Transformer For OffLoad +5 to -10 in Steps of 2.5% ,with standard accessoriescomplete with Test Certificate with losses below 780 watts at 50% load, 2300 watts at 100% load as per IS:1180 - 2014 Level II as per specification No SS- TR.with necessary permission of Electrical Inspector
Supplying and erecting fencing of section having size 2450 mm in height from ground level and 1200 mm width with angle iron frame work erected in C C foundationand painted as per specification No SS-AS/FSG
Supplying and erecting double leaf hinged dooreach1500mm in width x 1850 mm in height using B class ,GI pipe with angle iron supports, chain link wiremesh (jali) complete supported on channel iron, erected in foundation, and painted as per specification no SS-AS/DLD
Supplying & erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg. capacity cartridge type conform to IS 2878 /15683 complete erected with necessary clamp made from 50 x 6 mm. M. S. flat with nut & bolts routed in wall complete.
SITC of Electric Traction Passenger Lift with• Rated capacity :- 8 Passenger/544Kg• Floors :- G+1 floor (2Stops/2 Landings)• Travel :- 3 to 4.2 mtrs• Location of Lift Machine:- MR/MRL• Rated speed :- 1.0mps VS• Doors type :- COPO/TOPO Doors with frame having clear opening of 800 mm wide x 2000 mm high made from SS 304 grade sheet of 1.5mm, thick in hairline finish for car and all landing doors with SS door rchitraves/frames• Lift car enclosure made from SS 304 grade sheet of 1.5mm, thick with hairline finish with frame made from MS girders, bracing of adequate size with minimum safety factor of 5, with Toe Guard Apron, with necessary false ceiling with adequate LED lights, blower/fan for ventilation & SS chequered plate flooring, handrails, mirror, emergency light etc.• COP with SS face plate having metallic push buttons with Braille Code & luminous indicator around button with FPI, scrolling UP/DN LED indicator & with/without attendant key switch, OWD with audio-visual alarm, VAS in Marathi, Hindi & English with intercom system with telephone instrument in Lift car, LMR & FCC/ground floor• Clear Car size of ......mm wide x ......mm deep x ......mm high • LOP with SS face plate having recess/surface push button box for all landings with scrolling UP/DN LED indicator having metallic push buttons with Braille Code & luminous indicator around button with CPI, Lift car arrival & next travel direction audio-visual indication at all landings • Lift controller based on microprocessor/ PLC with VVVF Drive having closed loop control system, with IBMS compatible having necessary port, control panel duly wired with proper size & strength copper wire for power & control circuit, with provision for addition of floor/control card & allied accessories control panel having enclosure of 1.5mm CRCA sheet with powder coating with IP54 Protection class • ARD complete with necessary SMF VRLA batteries• Fireman controller having fireman switch at fire Landing,• CCTV surveillance system comprises of 2nos minimum 2.0MP FHD IP based vandal proof Dome camera in lift car & in LMR/inside lift shaft top aimed on Lift machinery & controller with NVR kept in LMR/FCC with HDR data backup for 60 Days with 18" FHD TV monitor, to be kept in FCC/LMR as directed by Engineer In Charge. • Lift Machine of Gearless PMSM of suitable kW with Traction pulley, OSG, electromagnetic brakes, entire assembly mounted on adequate size girders duly fixed on LMR floor/ shaft walls complete with main/diverter traction sheaves, suspension wire ropes/belts of adequate size & strength• Other mechanical parts such as 'T' section adequate size guide rails for car & counter weight with brackets fasteners, counter weight frame with necessary blocks, buffers with necessary support arrangement, MS pit ladder etc. erected with necessary steel work • Minor civil work for alteration if any and erection of door frames and accessories, erection buffers, erection of lift machinery, adequate size core cuts if required & scaffolding for erecting guide rails fixing of girders for mounting lift machine etc. complete as per specification no. LFT.MAHARASHTRA PWD CSR 2018-19, I No: - 17-1-3 Notes 1) General: - Job includes entire procedure of obtaining all necessary erection permissions & "License to Work the Lift" from Electrical Inspector(Lifts) with submission to the Engineer In Charge. 2) Warrantee: - Job covers three years onsite warrantee for all the Lift parts with FCAMC as per the maintenance schedule.
ADD ON for LIFT For Lift having 800mm wide x 2000mm high clear entrance in 1.5mm thick SS 304 grade landing door [Two panel], this includes all necessary accessories like LOP's with UP/DN buttons-arrowsindicators, extension of guide rails, shaft wiring with trunking, traveling cables, main hoisting ropes/belts, & OSG rope landing doors with all accessories etc. necessary for the normal safe functioning of lift installation complete
For Lift car having 800mm wide x 2000mm high clear entrance having 1.5mm thick SS 304 grade sheet car door [Two panel] complete with required accessories like door operator mechanism with drive, required Aluminium sill, infrared curtain & necessary wiring with interlocking arrangement etc. complete
For Full Collective control system, add as below. 1 For Lift travelling above First floor & up to Sixth floor
'Supplying and fixing following way SPN sheet steel MCB distribution board 240 V on surface/ recess complete with tinned copper busbar neutral busbar earth bar dinnbar detachable gland plate interconnections phosphotized and powder painted including earthing etc. as required ( but without MCB/RCCB/Isolator) (n) 8 way double door Cat B
'Supplying and fixing following way TPN sheet steel, double door, Horizontal type MCB distribution board 415 V on surface/ recess complete with tinned copper busbar neutral busbar earth bar dinnbar detachable gland plate interconnections phosphotized and powder painted including earthing etc. as required ( but without MCB/RCCB/Isolator) (f) 4 way (4+12), double door, Horizontal type Cat B
'Supplying and fixing following way TPN sheet steel, double door, Horizontal type MCB distribution board 415 V on surface/ recess complete with tinned copper busbar neutral busbar earth bar dinnbar detachable gland plate interconnections phosphotized and powder painted including earthing etc. as required ( but without MCB/RCCB/Isolator) (g) 6 way (8+18), double door, Horizontal type Cat B
Supplying and fixing 6 A to 32 A, C series MCB suitable for lighting and other loads of following poles in the existing MCB DB complete with connections testing and commissioning etc as required.
Supplying and fixing 6 A to 32 A, C series MCB suitable for lighting and other loads of following poles in the existing MCB DB complete with connections testing and commissioning etc as required. DP, Cat A
'Supplying and fixing 6 A to 32 A, C series MCB suitable for lighting and other loads of following poles in the existing MCB DB complete with connections testing and commissioning etc as required. (j) 6-32 A TPN, Cat B
Supplying and fixing 63 A, C series MCB suitable for lighting and other loads of following poles in the existing MCB DB complete with connections testing and commissioning etc as required. TPN, Cat A
Supplying and fixing following rating double pole (single pole and neutral) 240 V RCCB having a sensitivity current upto 300mA in the existing MCB DB complete with connections testing and commissioning etc as required '(b) 40 A, Cat A
'Supplying and fixing following rating four pole (triple pole and neutral) 415 V RCCB having a sensitivity current upto 300mA in the existing MCB DB complete with connections testing and commissioning etc as required (b) 40 A, Cat A
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable in the independent surface / recess PVC conduit ( medium)of appropriate size as required. C)2 x 4 sq.mm + 1 x 4 sq.mm earthwire (20mm Conduit)
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable in the independent surface / recess PVC conduit ( medium)of appropriate size as required. I) '4 x 4 sq.mm + 2 x 4 sq.mm earthwire (25mm Conduit)
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in recessed PVC conduit(heavy) with modular switch, modular plates, suitable size modular GI box of specified Category and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group B -- with Cat A Modular Accessories
(b) 2 x 2.5 sq.mm + 1 x 2.5 sq.mm earthwire (20mm Conduit)
Wiring for plug on board with Switch socket concealed type and copper wiring, earthing and with modular accessoriesas per specification No: WG-PW/CW
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in recessed PVC conduit(heavy) with 2 way modular switch, modular plates, suitable size modular GI box of specified Category and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Wiring for group controlled light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in recessed PVC conduit(heavy) and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Supplying and fixing suitable size modular PVC box with modular plate and cover in front on surface or in recess including providing and fixing 1 no 6 pin 15/16 A modular socket outlet and 1 nos 15/ 16 A modular switch connection painting etc. as required. ( For workstations)
Supplying and fixing suitable size modular GI box with modular plate and cover in front on surface or in recess including providing and fixing 2 no 6 pin 15/16 A modular socket outlet and 2 nos 15/ 16 A modular switch connection painting etc. as required. ( For workstations)
Supplying and fixing PVC synthetic elastomer electrically insulating mat with class B insulation conforming to IS: 15652 – 2006 & CPRI tested having 2.5 mm thickness upto 11 Kv
V MISSION
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .