Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.3 CrAccepted-AOC | ₹14.3 Cr Quoted ₹14.9 Cr | L1 | Accepted-AOC Work Order Issued |
| 2 | L2₹15.0 CrRejected-AOC BAJUGAON CITY TOWN GOSSAIGAON P O JARAGURI P S GOSSAIGAON DIST KOKRAJHAR PIN 787000 | 787000 | ₹15.0 Cr | L2 | Rejected-AOC L2 |
| 3 | Rejected-Technical J P AGARWAL ROAD GUARIPUR DHUBRI SIVSAGAR 783331 | DHUBRI | ASSAM | 783331 | - | - | Rejected-Technical Non-Responsive |
Tender Value
₹11.9 Cr
EMD Value
₹23.9 L
Closing Date
25 Jul 2024, 2:00 pmClosed
Addl. Chief Engineer, PWD(R AND B), Hills, Assam,
O/O The Addl. CE, PWD(R AND B), Hills, Assam, Haflong
Construction of Veer Sambudhan Phonglo Memorial Park at Maibang, Dima Hasao under DHATC Package
2024_PWD_37941_1
ACEH/TECH/CS/2/2024-25/7 Dated Haflong the 4th July 2024
Open Tender
Civil Works - Building
545 days
Dima Hasao
Please refer Tender documents.
5 documents required · 5 mandatory
₹23,890
₹23.9 L
Yes
10 Sept 2024
10 Jul 2024
29 Jul 2024
10 Jul 2024
25 Jul 2024
12 Jul 2024
Amount
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50m.All kinds of soil.
Supplying and filling in plinth with sand under floors, including watering ramming, consolidating and dressing complete
Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) :Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300mm apart including drilling 12mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor:With Chlorpyriphos/Lindane E.C. 20% with 1%concentration.
PLAIN CEMENT CONCRETE WORKS Plain cement concrete floor base in prop1:3:6 laid in alternate bays as specified with coarse agg. of size 13mm to 32mm including dewatering if necessary, and curing etc. complete.
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone - III) : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
REINFORCED CEMENT CONCRETE WORKS Poviding and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete b) M20 grade concrete or Prop. 1:1.5:3
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement.1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20mm nominal size).
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more
TIMBER SHUTTERING (FORMWORK) Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in: Foundation, footings, bases of columns, pile cap, raft and mass concrete works etc.
Lintels, beams, plinth beams, girders, bressumers up to pl.
Columns, Pillars, Piers, Abutments, Posts and Struts.
Suspended floors, Gutter, roofs, landings, balconies and access platform with water proof ply 12mm thick.
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:In proportion 1:4.
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.Cement mortar 1:4 (1 cement :4 coarse sand).
Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level withCement mortar 1:6 (1 cement : 6 coarse sand)
Dry brick on edge flooring in required pattern with bricks of class designation 7.5 on a bed of 12 mm mud mortar, including filling joints with Jamuna sand, with common burnt clay non modular bricks.
Marble stone flooring with 18 mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with.Raj Nagar plain
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joints with white cement and matching pigments etc.Size of Tile 1000x1000mm.
Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm,including pointing in white cement mixed with pigment of matching shade complete.
1:4 (1 cement: 4 fine sand)
1:4 (1 cement: 4 fine sand)
15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand)
Distempering with oil bound washable distemper of approved brand and manufacture to give an even etc.New work (two or more coats) over and including water thinnable priming coat with cement primer.
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer
Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade.Two or more coats on new work.
Painting with black anti-corrosive bitumastic paint of approved brand and manufacture to give an even etc.Two or more coats on new work
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required etc.New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm).
Providing and applying white cement based putty of average thickness 1mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).Second class teak wood
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of.35 mm thick including ISI marked Stainless Steel butt hinges.
Providing and fixing 18mm thick, 150mm wide pelmet of flat pressed 3 layer or graded wood particle board medium density grade I, IS : 3087 marked, including top cover of 6mm commercial ply wood conforming to IS: 303 BWR grade, nickel plated M.S. pipe 20mm dia (heavy type) curtain rod with nickel plated brackets, including fixing with 25x3 mm
Providing and fixing chromium plated brass curtain rod having wall thickness of 1.25mm with two chromium plated brass brackets fixed with C.P. brass screws and PVC sleeves etc., wherever necessary.25 mm dia
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings /wooden frames with rawl plugs screws etc.
Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete :125x64x1.90 mm.
Providing and fixing chromium plated brass handles with necessary screws etc. complete:125mm.
Providing and fixing factory made uPVC white colour casement/casement cum fixed glazed windows comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforcedwith 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVCprofile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (whitepowder coated) casement handles, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately) Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerancein dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. Casement window double panels with S.S. friction hinges (300 x 19 x 1.9 mm) made of (small series) frame 47 x 50mm, sash 47 x 68 mm & mullion 47 x 68 mm all having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area of window above 0.75 sqm upto.
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes.
Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpetwashers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.1.00 mm thick with zinc coating not less than 275 gm/m².
Providing ridges or hips of width 60 cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete.0.80mm thick with zinc coating not less than 275 gm/m²
Providing & fixing false ceiling at all height including providing & fixing of framework made of special section, power pressed from M.S. sheets and galvanised with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleat of size 25mm wide x 1.6mm thick with flanges of 27mm and 37mm, at 1200mm c/c, one flange fixed to the ceiling with dash fastener 12.5mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25 x10 x0.50mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I chanels 45 x15 x 0.90mm running at the spacing of 1200mm c/c, to which the ceiling section 0.5mm thick.8mm thick Calcium Silicate Board made with Calcareous & Siliceous materials reinforced with cellulose fiber manufactured through autoclaving process.
Making of statue for Veer Sambudhan Phanglo including erection at reqd. position of Bronze Metal of 3.6mm height i.e. 2 times the normal human size, (Rate as per market study).
Galv. Chain around the statue plat form. (rate is taken as lump-sum basis).
Providing and laying of inter locking concrete block pavement (ICBP) with cement concrete paver blocks as per IS 15658-2006 of thickness 80mm and 28 days compressive strength not less than 30 N/m over a layer of bedding sand of compacted thickness 30mm, laid either in stretcher/ running/ herringbone pattern of bonds as directed by the engineer and in proper level and grade and compacted with appropriate equipment such as plat vibrator along with spreading of a thin layer of joint filling sand to fill up the gaps between blocks including construction of edge restraint wherever required complete as per drawings and Technical specification clause 1504 of MORD.
For normal preparation of site
SANITARY AND WATER SUPPLY WORKS Providing and fixing water closet squatting pan (Indian type W.C.pan) with 100mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlleddevice (handle lever) conforming to IS : 7231, with all fittings andfixtures complete, including cutting and making good the walls and floors wherever required:White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests.
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid.
Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430 x 260 x 350mm and 340 x 410 x 265mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required.One urinal basin with 5 litre white P.V.C. automatic flushing.
Providing and fixing one piece construction white vitreous china squatting plate with an integral longitudinal flushing pipe, white P.V.C. automatic flushing cistern, with fittings, standard size G.I./ PVC flush pipe for back and front flush with standard spreader pipes with fittings, G.I clamps and C.P. brass coupling complete, including painting of fittings and cutting and making good the walls and floors.Single squatting plate with 5 litre P.V.C. automatic flushing cistern.
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls.White Vitreous China Wash basin size 630 x 450mm with a pair of 15mm C.P. brass pillar taps.
Providing and fixing kitchen sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P. brass waste complete, including painting the fittings and brackets, cutting and making good the walls wherever required:White glazed fire clay kitchen sink of size 600x450x 250 mm.
Providing and fixing controlled flush, low level cistern made of vitreous china with all fittings etc.10 litre (full flush) capacity-white
Providing and fixing G.I. inlet connection for flush pipe connecting with W.C. pan.
Providing and fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge.
Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved.Circular shape 450mm dia.
Providing and fixing toilet paper holder :
Providing and fixing soil, waste and vent pipes :Sand cast iron S&S pipe as per IS: 1729.
Sand cast iron S&S pipe as per IS: 1729.
Providing and filling the joints with spun yarn, cement slurry and cement mortar 1:2 (1 cement : 2 fine sand) in S.C.I./C.I. Pipes.75mm dia pipe.
Providing and filling the joints with spun yarn, cement slurry and cement mortar 1:2 (1 cement : 2 fine sand) in S.C.I./C.I. Pipes.100mm dia pipe.
Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10 x 10 x 10cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size), including cost of cutting holes etc.75mm dia pipe.
Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10 x 10 x 10cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size), including cost of cutting holes etc.100mm dia pipe.
Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete.Sand cast iron S&S as per IS - 1729.
Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete.Sand cast iron S&S as per IS - 1729.
Providing and fixing double equal junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete :Sand cast iron S&S as per IS - 1729
Providing and fixing double equal junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete :Sand cast iron S&S as per IS - 1730.Sand cast iron S&S as per IS - 1729
Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors :Sand cast iron S&S as per IS: 3989.
Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape withbracket of the same materials with snap fittings of approved qualityand colour, weighing not less than 105 gms.
Providing and fixing PTMT towel ring trapezoidal shape 215 mm long 200 mm wide with minimum distances of 37 mm from wall face withconcealed fittings arrangement of approved quality and colour,weighing not less than 88 gms.
WATER SUPPLY Providing and fixing Polyethelene-Aluminium-Polyethelene PE-ALPE Composite Pressure Pipes conforming to IS - 15450, U.V. stabilized with carbon black having thermal stability for hot & cold water supply, capable to withstand temperature up to 80°C, including all special fittings of composite material (engineering plastic blend and brass inserts wherever required) e.g. elbows, tees, reducers, couplers & connectors etc., with clamps at 1.00 metre spacing. This includes testing of joints complete as per direction of the Engineer-in-charge. INTERNAL WORK - EXPOSED ON WALL 1216 (16mm OD) pipe.
1620 (20mm OD) pipe.
2025 (25mm OD) pipe.
4050 (50mm OD) pipe.
Providing and fixing Polyethelene-Aluminium- Polyethelene PE-ALPE Composite Pressure Pipes conforming to IS - 15450, U.V. stabilized with carbon black having thermal stability for hot & cold water supply, capable to withstand temperature up to 80°C, including all special fittings of composite material (engineering plastic blend and brass inserts wherever required) e.g. elbows, tees, reducers, couplers & connectors etc., with trenching, refilling and testing ofjoints complete as per direction of the engineer in charge. External work 1216 (16 mm OD) pipe
1620 (20 mm OD ) pipe
4050 (50 mm OD ) pipe
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 15 mm nominal dia Pipes
20 mm nominal dia Pipes
50 mm nominal dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 25 mm nominal dia Pipes
50 mm nominal dia Pipes
150 mm nominal dia Pipes
Providing and fixing Stainless Steel pipe and fitting of grade 316L as per IS 6911:2017 and conforming to EN-10312 standards complete with press type fitting (fitting shall be paid for separately) i/c fixing of the pipe with clamps at 1.00 m spacing including cutting and making good the walls including testing of joints complete as per direction of Engineer-in-charge. (The pipe length inserted in the fitting shall not be measured for payment) Inernal work - Exposed on wall 15 mm outer dia pipe
35 mm outer dia Pipe
Providing and fixing brass bib cock of approved quality.20 mm nominal bo
Providing and fixing brass stop cock of approved quality :20 mm nominal bore.
Providing and fixing PTMT pillar cock of approved quality and colour. 18.56.1 15 mm nominal bore, 107 mm long, weighing not less than 110 gms
Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms.
WIRING IN STEEL AND PVC CONDUIT Wiring for light point/ fan point/exhaust fan point/call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group A
Group B
Group C
Wiring for light/power plug with 2x4 sq.mm FRLS PVC insulated copper conductor single core cable in surface/recessed steel conduit alongwith 1 No. 4 sq.mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for light/power plug with 4x4 sq.mm FRLS PVC insulated copper conductor single core cable in surface/recessed steel conduit alongwith 2 Nos. 4 sq.mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for light/power plug with 4x4 sq.mm FRLS PVC insulated copper conductor single core cable in surface/recessed steel conduit alongwith 2 Nos. 4 sq.mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. 2 x 1.5 sq. mm + 1 x 1.5 sq. mm earth wire
2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire
2 x 6 sq. mm + 1 x 6 sq. mm earth wire
2 x 10 sq. mm + 1 x 6 sq. mm earth wire
4 x 2.5 sq. mm + 2 x 2.5 sq. mm earth wire
4 x 6 sq. mm + 2 x 6 sq. mm earth wire
Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required. 2 x 1.5 sq. mm + 1 x 1.5 sq. mm earth wire.
2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire.
2 x 4 sq. mm + 1 x 4 sq. mm earth wire.
2 x 6 sq. mm + 1 x 6 sq. mm earth wire.
Supplying and drawing co-axial TV cable RG-6 grade, 0.7mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required.
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. 20 mm
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 20mm
Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 A switch
2 way 5/6 A switch
15/16 A switch
3 pin 5/6 A socket outlet
6 pin 15/16 A socket outlet
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 1 or 2 Module (75mmx75mm)
3 Module (100mmx75mm)
4 Module (125mmx75mm)
6 Module (200mmx75mm)
8 Module (125mmx125mm)
12 Module (200mmx150mm)
Providing and fixing plain 16/0.20mm (0.50sqmm) twin circular flexible FRLS PVC insulated, PVC sheathed copper conductor cable direct on the wall with PVC clips etc. as required.
Installation, testing and commissioning of pre-wired, fluorescent fitting/compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/wall, including connections with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
Installation, testing and commissioning of pre-wired, fluorescent fitting/compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc., including supplying and fixing ball and socket arrangement, 2 Nos. down rods of 20mm dia c 1.6 mm thick steel conduit upto 30 cm length, painting and wiring the down rods and connections with 1.5sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.
Supplying and fixing extra down rod of 10cm length G.I. pipe, 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5cm length shall be rounded to the nearest 10cm and 5 cm or less shall be ignored).
Supplying and fixing extra conduit down rod of 20cm length G.I. pipe 15mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10cm and 5 cm or less shall be ignored)
Numbering of ceiling fan/exhaust fan/fluorescent fittings as required.
Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. Group A
Group B
Group C
Wiring for twin control light point with 1.5sq.mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required.
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. 25 mm.
Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 amps switch
2 way 5/6 A switch
15/16 A switch
3 pin 5/6 A socket outlet
6 pin 15/16 A socket outlet
Telephone socket outlet
TV antenna socket outlet
Bell push
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing following size/modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 1 or 2 Module (75mm x 75mm)
3 Module (100mm x 75mm)
4 Module (125mm x 75mm)
6 Module (200mm x 75mm)
12 Module (200mm x 150mm)
Supplying and fixing brass batten/angle holder including connection etc. as required.
Installation, Testing, Commissioning of wall bracket/ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required.
Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in CUBICAL panel, making connection etc. as required. 32 A TP&N
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 125 A, 16 KA,TPMCCB
150 A, 16 KA,TPMCCB
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). 6 way , Double door
8 way , Double door
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 4 way (4 + 12), Double door
8 way (4 + 24), Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
Single pole and neutral
Triple pole
Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 A
Supplying and fixing Cable End Box (Loose Wire Box) suitable for triple pole and neutral, sheet steel, Vertical MCB distribution board, 415 Volts, on surface/recess, complete with testing and commissioning etc. as required. 400 A 25kA SC for 1 sec
500 A 30kA SC for 1 sec
630 A 50kA SC for 1 sec
Earthing with G.I. earth pipe 4.5 metre long, 40mm dia including accessories, and providing masonry enclosure withcover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt) as required.
Earthing with G.I. earth pipe 4.5 metre long, 40mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc.with charcoal/ coke and salt as required.
Supplying and laying 6 SWG G.I. wire at 0.50metre below ground level for conductor earth electrode, including connection/termination with GI thimble etc. as required.
Supplying including fitting fixing of following A.C. Ceiling fan complete with all accessories like down rod, canopy etc. of following sweeps with making necessary connection as approved by the Deptt.)as required complete and as directed by the Department [Without regulator].Premium model 1050 mm Sweep (ORIENT PSPO make)
Supplying including fitting fixing of following A.C. Exhaust fan in the existing hole on the wall of following sweeps with making necessary connection as approved by the Deptt.) as required complete and as directed by the Department.
Supplying installation, testing, programming and commissioning of Audio and video equipment, 4300 Lm WUXGA Installation Projector, 4300 lumens 3LCD Projector 2000:1 Contrast Ratio Native WUXGA (1920 x 1200) Resolution Up to 4000h , 3 LCD System .
Wiring for light/fan /call bell point with 2x1.5 sq mm insulated (ISI marked) 1.1 KV grade FR copper conductor cable (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) cable in surface/ recessed conduit wiring system with 20mm dia rigid ISI marked hot dip galvanised pipe (AKG or equivalent as approved by the Deptt.) including 6 amp flush type switch/ bell push (Anchor Penta/Gold medal /Kolor kany.kom/ Havells make) GI/ MS switch board (ISI marked) with phenolic laminated sheet cover ,ceiling rose (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) etc. complete Short point up to 3.00 metre. length.
Medium point up to 6.00 metre. Length.
Long point up to 10.00 metre. Length.
Wiring to 5 a pin 6 Amps plug point with 1.5 sq. mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed ISI marked hot dip galvanised pipe (AKG or equivalent as approved by the Deptt.) wiring system including 5 pin 6 Amps flush type plug socket and 6 Amps F/T switch (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.), GI/ MS switch board (I.S.I. marked) with phenolic laminated sheet cover including earth continuity with 1.5 sq. mm. cable to third pin of the plug socket etc. as required complete, when placed elsewhere. Short point up to 3.00 metre length.
Medium point up to 6.00 metre length
Long point up to 10.00 metre length
Wiring for 5/6 pin 16 Amps power plug point with 4 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed ISI marked hot dip galvanised 20mm. dia. pipe (AKG or equivalent as approved by the Deptt.) wiring system including and fixing 5/6 pin 16 Amps flush type socket outlets and 16 Amps flush type switch (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.), GI/ MS switch board (I.S.I. marked) with phenolic laminated sheet cover earth continuity with 2.5 sq. mm cable to the 3rd pin of the socket as required complete. Short point up to 3.00 metre length.
Medium point up to 6.00 metre length
Long point up to 10.00 metre length
Supplying and fixing 18 S.W.G sheet steel metal boxes of the following sizes in surface Wiring system with suitable size of 3 mm thickness phenolic laminated sheet cover on the front face of the boxes including painting etc. as required and specified by the department. 100 mm x 100 mm x 60 mm deep (Nominal size
100 mm x 150 mm x 60 mm deep (Nominal size
Supplying and fixing of Switch/Socket flush type (Anchor Penta PC CHERRY /Gold medal /Kolor kany.kom/Havells or equivalent make as approved by the Deptt.) on the existing PVC/ MS board including connection as approved by the Deptt.)complete as required.
Supplying and fixing of Switch/Socket flush type (Anchor Penta PC CHERRY /Gold medal /Kolor kany.kom/Havells or equivalent make as approved by the Deptt.) on the existing PVC/ MS board including connection as approved by the Deptt.)complete as required.
Supplying and fixing of Switch & Socket combined (S combine , (I.S.I. approve (Anchor Penta PC CHERRY /Gold medal /Kolor kany.kom/Havells or equivalent make as approved by the Deptt.) on existing PVC/ MS board including connection as approved by the Deptt.)complete as required
Supplying and fixing of batten holder (Anchor Penta PC CHERRY /Gold medal /Kolor kany.kom/Havells or equivalent make as approved by the Deptt.) including connection as approved by the Deptt.)as required Without Lamp
Supplying and fixing of batten holder including 11 W CFL lamp and connection as approved by the Deptt.)as required.
Supplying including fitting and fixing bus bar chamber ( HPL/ GECO / or equivalent make) with 4 strips bus bar of length 350/450/600/900 mm made of aluminium alloy or wrought aluminium suitable for 100 amp capacity complete with all accessories including connection etc. as required complete
Supplying including installation, commissioning of vermin and dust proof totally enclosed, Phosphatised Powder Painted cubical outdoor type double door, floor mounting compartmentalize panel board of size 1.35M X 1.20MX 0.40M made of 16 SWG1.66 m thick C.R. sheet and 35mm X 35mm X 5mm size angle having 4 no legs at the bottom and C.R. sheet roofing on the top complete painting with 2 coats of Red Oxide metal primer and 2 coats of enamel paint. The panel board is to be erected in 1 : 3 : 6 PCC foundation including excavation of trench and brick soling etc. complete neatly Wiring done with provision for one no 125/160A 4pole MCCB or Switch Fuse Unit as incomer and provision for 6nos DP or TPN out going as specified and directed by the deptt. confirming to IP 65 protection comprising of the following electrical items: (Incoming & Outgoing Switch Gear of reqd. rating will be measured and paid separately)
Supplying including installation, testing and commissioning of Readymade Panel board conforms to IS : 8623, IEC : 60439 made of Phosphatised powder painted wall mounting type complete with Ana log meter module cable Alley both LHS and RHS, Copper Bus bar, Din Rail, Neutral Bar, Earth Bar etc. with Provision for 1 No. 4 pole MCCB as incomer and provision for 8 Nos.TP MCCB out goings as specified and directed by the deptt. and comprising of the following electrical items: (Incoming and Outgoing MCCB of reqd. rating will be measured and paid separately)
Supply with installation & commissioning of readymade maintenance free CPRI approved chemical earthing system with 50mm dia. 2.00 Metres length corrosion free Single pipe technology- Copper CHEMRODE ELECTRODE complete with RESLOW Grounding Minerals (25 K and Advance Earth Pit cover (PV including excavation of earth pit and construction brick earth chamber including plastering both inner & outer surface of brick wall as specified and directed by the deptt.
Supplying, erection, testing and commissioning of 12 M high mast system with its accessories such as foundation bolts manufactured from special steel along with nuts, washers, anchor plates and templates, non-integral flood light luminaries with 1 no. 400 W HPSVT lamps and its control gear boxes (Bajaj/ Crompton/ Wipro/ HPL/ Solar/ Philips make) twin dome aviation obstruction lights of with Neon spiral lamps, control panel housing 32 A TPN MCB incomer, single dial timer contactor circuit for the automatic control of luminaries, outgoing terminals and control circuit for the power tool motor. Mast shaft shall be in two sections, hot dip galvanised and suitable for wind velocity as per IS 875. It shall also include accessories for high mast including head frame, steel rope 6 mm dia ( 7 / 19 construction) , trailing cable, double drum winch, Galvanised Lantern carriage arrangement suitable for 6 luminaries symmetrically & its control gear boxes and lightning finial. The mast shall be erected on suitable shallow foundation with 1 : 2 : 4 concrete for the high mast considering the safe soil bearing capacity at site as 10 T / Sq meter at 2 metre depth. The mast shall have an integral power tool installed inside the base compartment for its operation.(BAJAJ/ SRB/VALMONT/ PHILIPS/PARUTHI ENGR make) Supply of foundation bolts manufactured from special steel along with nuts, washers, anchor plates and templates Supply of 6 nos. non-integral flood light luminaries with one nos 400 W HPSVT lamps and its control gear boxes. Supply of twin dome aviation obstruction lights with Neon spiral lamps.Supply of control panel housing 32 A TPN MCB incomer, single dial timer contactor circuit for the automatic control of luminaries, outgoing terminals and control circuit for the power tool motor. Construction of suitable shallow foundation with 1 : 2 : 4 concrete for the high mast considering the safe soil bearing capacity at site as 10 T/Sq meter at 2 metre depth with all materials and labour. Erection of the high mast with the help of suitable equipments and Wiring of luminaries with all Wiring materials and labour. provision of GI pipe earthing for high mast with 2.5 m long 40 mm dia GI pipe including connection as approved by the Deptt.)to high mast terminal with 25 x 3 mm GI strip with all materials and labour. ( 2 nos per mast require ..Erection of the above panel on suitable foundation including all materials and labour.
Supply with fitting & fixing 60 mm dia 3660 mm height 2-in-one combination double arm integrated with acrylic diffusers, translucent top, bottom clear , black powder painted finish tubular pole .The pole is made of GI tube with GI cylindrical control box with service door and a circular base plate . The pole is swaged at the top to accommodate double arm bracket assembly, secured on to the top by means of 2 annular rings with Allen grub screws .The luminaries is designed for and integral with 2 nos 36 W CFL suitable for operation on 240 V 50 Hz single phase AC supply . The pole is to be fitted on 1:3:6 PCC pole foundation of size 300 mmx300 mmx1200 mm with grouting nuts & bolts as specified & directed by the deptt .(Metal Coats make).KALINGA-2 model or equivalent.
Supply and laying of following size PVC/XLPE insulated and PVC sheathed 1.1 KV G Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1) 1988 armoured U.G. cable U.G. cable laid in ground/partially in air (as required for termination over ground including excavation of cable trench up to depth of 75cm, refilling, protective brick covering, Sand cushioning etc complete handling of surplus spoil, debris et to proper place as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make) . 3 Core A2XWY A2XFY 4.00 Sq.mm 3 Core armoured U.G. cable
6.00 Sq.mm 3 Core armoured U.G. cable
10.00 Sq.mm 3 Core armoured U.G. cable
Making of trench for drawing of HDPE pipe/duct on it and refilling the same after drawing of HDPE pipe/duct, as directed and specified by the deptt.
Supply including fitting and fixing of Resin Cast type 1.1 KV PVC/XLPE/PILC cable Straight through Jointing Kits (MS - SE AL make) including all accessories for the following sizes including testing and commissioning as specified and directed by the Deptt. 185.00 Sq.mm., 3.5 Core cable.
upply including fitting and fixing of 1.1 KV PVC/XLPE cable Straight through Jointing Kits RAYCHEM RPG TUBULAR SLEEVE VERSION including all accessories for the following sizes including testing and commissioning as specified and directed by the Deptt. 10.00 -16.00 Sq.mm., 3/3.5/4 Core cable.
25-50.00 Sq.mm., 3/3.5/4 Core cable.
Supply including fitting and fixing of outdoor cable Junction Boxes IP 66 halogen free and weather proof for outdoor installation ( with metric knockouts for cable entry) on existing pole with clamp nut &bolts, including all accessories complete as specified and directed by the Deptt. cable size 2.5 sq.mm box size 88 x 88 x 53 all in mm
cable size4 sq.mm box size 98 x 98 x 61 all in mm
cable size 6 sq.mm box size 139 x 119 x 70 all in mm
Supplying, installation testing and commissioning of the following rating copper wound indoor/out door type transformer complete including the payment to be made to power supply authority for supervision charge, labour charge, cost of L.T/H.T metering etc. (excluding the cost of load security) and making necessary arrangement for charging approval of the sub-station from the competent authority as directed and specified by the department. Transformer should be as per CEA guidelines as ammended up to date upto 200 KVA star rating up to 5 star, above 200KVA as per CEA guidelines for losses along with LV enclosure.200 KVA,50Hz.11/0.433 KV. Oil filled transformer with Off Circuit tap change.
Supplying and erection PSC pole 7.5 metre long, the pole is to be erection in 1:2:3 plain cement concrete foundation of size 1.50 m x 0.45 m x 0.45m having P.C.C base foundation 15 cm x 60 cm x 60cm including edge brick soiling and plastering above G.L. portion (0.30 metre complete with excavation of earth, handling of Surplus Soil, debris etc. to the proper place and refilling etc. as specified and as directed by the department.
Supplying and erection of L.T. stay set complete (Galvanize with 19mm dia x1.8m long stay rod anchor plate of size 30cm x 30cm x 6.4 mm thimble stay clamps tube buckle (19mmx 60c 7/14 SWG dia G.I stay and strain insulation etc. in cement concrete 1:3:6:(1Cement:3Course sand:6graded stone aggregate 40mm nominal size foundation including excavation and refilling etc. as required and as directed by the department.
Supplying and fitting fixing of galvanised L.T. T cross arm complete with clamps ,blots, nuts etc. as required and as directed by the department.
Supplying and fitting fixing of galvanised channel of 75 mm x 40 mm x 65 x 2200 mm long complete with clamps ,blots, nuts etc. as required and as directed by the department.
Supplying and fitting fixing of galvanised Angle of 50 mm x 50 mm x 60 x 5000 mm long complete with clamps ,blots, nuts etc. as required and as directed by the department.
Supplying and fitting fixing of 11 KV T Cross arm complete with clamps ,blots, nuts etc. as required and as directed by the department.
Supply and erection of 15/ 6 amp aerial fuse complete as required and as directed by the department.
Supplying and fixing of 50 mm x 3.2 metre. hot dip galvanised pipe (AKG or equivalent as approved by the Deptt.) (including accessories 50mm x 50mm x6mm angle iron bracket on the wall and 75 mmx 90mm shackle insulator with straps for house service connection as approved by the Deptt.)as required and as directed by the department.
Supplying and fixing of 11 KV 400 A Gang operated switch with all accessories complete as required and as directed by the department.
Supplying and fixing of 11 KV 5 KA Lighting arrestor (Poly) set complete as required and as directed by the department.
Supplying including installation, connection as approved by the Deptt., testing and commissioning of CENTRIFUGAL MONOBLOCK PUMP SET complete as directed and specified by the deptt.15 HP three Phase Centrifugal monoblock pump set (Crompton Greaves/Aquatic/CRI/ V-Guard make) 2900 rpm A class insulation with Star delta Starter (Crompton Greaves/ Control & Switch Gear/ BCH/ L& T/Siemens make) Fully Automatic citation.
MOTOR STARTER. Supplying fitting and fixing including necessary connection as approved by the Deptt.)of Starter (Crompton Greaves/ Control & Switch Gear/ BCH/ L& T/Siemens make) of following type and capacity as specified and directed by the Department. ( Crompton Greaves/ Control & Switch Gear/ BCH/ L& T / Siemens make) D.O.L Starter ( Crompton Greaves/ Control & Switch Gear/ BCH/ L& T / Siemens make)15 HP, 17.4 TO 24 A.
DIESEL GENERATOR. Supplying including installation, testing and commissioning of Air/Water Cooled Diesel Generator set coupled to suitable alternator of 220/415 V, AC, 1/3-Phase 0.8 p.f.(la mounted on a 1) M.S. Fabricated base frame.,2) M.S. fuel tank of required capacity.,3) Residual Silencer.,4) Standard Control Panel.5) Suitable batteries with lead.,5) First fill of lube oil.,6) Acoustic Enclosure complete with all accessories as specified and directed by the department conforming to IS comprising the Technical Specification.. as per manufacturer. (RANGE FROM 5 KVA TO 625 KVA) Kirloskar green/bliss, Leyland, Volvo Penta, Perkinson, Mahindra, Greaves, Escort engine and Kirloskar, Stamford, Leroy somer alternator.100 3 3200x1300x1805 1950 Kg W/C
EPABX. Supplying and fitting fixing of Hi-Path 1150M Digital Communication System equipped with the following: 2 P&T Ports - 34 Extension Ports (upgradeable up to 50 extensions) Auto Call Back, Built-in FAX/DID 3 party Conference In-built Caller ID Supports PRI/BR Built in Voice Guided Direct inward Dialling 3 party Conference In-built Caller ID 100% Non- Block (SIEMENS or equivalent as approved by the Deptt.)
Supplying installation testing and commissioning of 1/3" Super HAD Colour CCD, 600 TV LINES, 0.15 LUX, 3.7mm Fixed Lens, Compact, light weight, DC12V (SAMSUNG or equivalent HONEYWELL/PANASONIC make)
Supplying installation testing and commissioning of Video Management Software with analytics: Video compression (server): JPEG/MPEG-4, Audio compression: G711/G726, Number of cameras to be connection ted: 32, Number of clients to be connection ted: 10, Maximum number of layouts: 100, Maximum number of users: 100
Supplying installation testing of UTP CAT 5 Cable without PVC conduit
SOLAR POWER . Supply of Solar street light with IP 65 LED fixture having a system wattage of 21W of Philips BRP 402 make) with 1864 lumen system output, 100Wp high efficiency crystalline solar panel certified IEC 61215 and 100Ah tubular lead-acid battery with BIS approval. Total Nos. of LED is 16 with individual Peanut Lens and each LED lumen efficacy shall be at least 130 lumens/watt and the LED driver should have > 90% efficiency. The battery shall not be discharged beyond 75% of capacity. The solar charge controller is of Microprocessor Based MPPT make) with 94% efficiency and enclosed in IP 65 box. The charge controller shall provide all safety protections and temperature compensated charging of the batter. The battery shall be housed in a box made from galvanized steel and powder coated so that it withstands corrosion. The solar system should be mounted on a 6.0 Metres MS Galvanized Tubular Pole. The solar street light shall comply with standards such as IEC 61215, IEC 62124, IEC 61347-2-13, IEC 62384, CISPR 15, IEC 61547, and IEC 60598.
Installation & Commissioning Charges for street light including cc foundation as directed by the Deptt.
Excavation in soil using Hydraulic Excavator CK 90 and Tippers with disposal upto 1000 metres. (Excavation for roadway in soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, loading and disposal of cut road with in all lifts and leads upto 1000 metres)
By Mix in place method (Construction of granular sub-base by providing close graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC and compacting with vibratory roller to achieve the desired density, complete as per cl' 401 (with an initial lead of 5Km.) (Including cost of testing of materials at site and laboratory as directed by the deptt.)
Water bound mecadam ( providing laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with vibratory roller 8-10 tonnes in stages to proper grade and camber, applying and brooming requisite type of screening/ binding materials to fillup the interstices of coarse aggregate, watering and compacting to the required density (with an initial lead of 5.0km.). Rate as per analysis-II
ICBP :- Providing and laying interlocking concrete block pavement having thickness 80mm as per drawing and technical specified, clause 1504
c) Providing and laying M-40grade cement concrete Edge block/ Edge restraints complete as per Technical specified clause 1504
Supplying , fitting and fixing barbed wire fencing with seven strands of barbed wire 12 S.W.G.x 2pliesx 4 points at 75mm apart including supplying fitting and fixing sawn sal wood posts of 100mmx100mm size struts 1800mm long at 1500mm apart driven at least 600mm under ground with providing 100mmx75mm size struts 1800mm long in corner, straining and end post as necessary including coaltaring two coats in posts and struts and supplying necessary nails, staples etc.complete as directed and specified (the distribution of the barbed wire should be placed at equal intervals for the intermediate except bottom and top which is to be placed at 100mm and 230mm clearance respectively).
Providing drain with cement concrete (1:3:6) 10cm thick sides 10cm thick bed over brick flat soling including 15mm thick cement plastering in prop. 1:3 finished with a floating coat of cement slurry as directed with necessary shttering for sides and earth work in excavation of foundation trenches and refilling the sides after completion of work etc. as specified. i). 300mm wide and average 150mm deep with bed slope 1 in 150 with initial depth of 100mm.
ii). 300mm wide and average 250mm deep with bed slope 1 in 150 with initial depth of 100mm.
POT PLANTING Supplying and planting of terrestrial orchids with required size of pot including filling the pot to the top surface with appropriate soil media made of garden soil, river sand, cow-dung, leaf mould, fertilizer, pesticides as per specification and necessary maintenance for a period of 4 months from the date of planting complete as specified and directed . (Mixing of different ingredients of soil media to be made in presence of Deptt. official / Specialist concerned) (A) With Aeirides (III) Using concrete pot of 60 cm dia.
(B) With Dendrobium (Hybrid) (III) Using concrete pot of 60 cm dia.
(C) With Mokara (III) Using concrete pot of 60 cm dia.
(D) With Vanda (hybrid) (III) Using concrete pot of 60 cm dia.
Supplying and planting of house plants in required size of pot including filling the pot to the top surface with appropriate soil media of garden soil, river sand, cow-dung, leaf mould, fertilizer, pesticides as per specification and necessary maintenance for a period of 6 months from the date of planting complete as specified and directed . (Mixing of different ingredients of soil media to be made in presence of Deptt. official / Specialist concerned) (A) With Fancy leaf caladium/Coleus (iii) Using concrete pot of 60 cm dia.
(B) With Indian rubber plant / Prayer plant (iii) Using concrete pot of 60 cm dia.
(C) With Fragrant dracaena / Silver net leaf / Philodendron / Devil's back bone /Peperomea/Croton (iii) Using concrete pot of 60 cm dia.
(D) With Peacock/spider/Umbrella (iii) Using concrete pot of 60 cm dia.
(E) With Maiden hair fern/Aloe/Boston fern/Swiss cheese plant/Forget me not (iii) Using concrete pot of 60 cm dia.
(F) With Marry Christmas begonia / Polypodium / Aluminium plant (III) Using concrete pot of 60 cm dia.
(G) With English Ivy (III) Using concrete pot of 60 cm dia.
(H) With Iron Cross Begonia (III) Using concrete pot of 60 cm dia.
Supplying and planting of palms with required size of pot including filling the pot to the top surface with appropriate soil media made of garden soil, river sand, cow-dung, leaf mould, fertilizer, pesticides as per specification and necessary maintenance for a period of 4 months from the date of planting complete as specified and directed. (Mixing of different ingredients of soil media to be made in presence of Deptt. official/Specialist concerned) (A) With Bottle palm (III) Using concrete pot of 60 cm dia.
(B) With Erica palm (Butterfly palm)/ Kentia palm (III) Using concrete pot of 60 cm dia.
(C) With Chinese Palm (III) Using concrete pot of 60 cm dia.
(D) With Fan Palm /Finger palm (III) Using concrete pot of 60 cm dia.
Supplying and planting of seasonal flower in required size of pot including filling the pot to the top surface with appropriate soil media made of garden soil, river sand, cow-dung, leaf mould, fertilizer, pesticides as per specification and necessary maintenance for a period of 4 months from the date of planting complete as specified and directed . (Mixing of different ingredients of soil media to be made in presence of Deptt. official / Specialist concerned) (I) Using earthen pot of 30 cm dia.
Supplying and planting of cactus in required size of pot including filling the pot to the top surface with appropriate soil media made of garden soil, sand, cow-dung, fertilizer, pesticides as per specification and necessary maintenance for a period of 6 months from the date of planting complete as specified and directed . (Mixing of different ingredients of soil media to be made in presence of Deptt. official / Specialist concerned) (A) With Peanut Cactus / Rat tail Cactus (III) Using concrete pot of 60 cm dia.
(B) With Prickly pear (III) Using concrete pot of 60 cm dia.
BED PLANTING Supplying and planting of Dahlia / Chrysanthemum / Gladiolus on the ground ( bed planting, bed size 45 cm x 45 cm x 45 cm) including the preparation of the soil, providing organic manure and fertilizer, pesticides as per specification and necessary maintenance for a period of 4 months from the date of planting complete as specified and directed .
(B) With Hybrid tea rose / Miniatune rose
HEDGE PLANTING / EXTERNAL HEDGE Supplying and planting of suitable plant materials for preparation protective / external hedge (50 cm wide) including the preparation of the ground by mixing organic manure and fertilizers as per specification and necessary maintenance for a period of one year from the date of planting complete as specified and directed . (A) ADOPTING SINGLE ROW PLANTING METHOD (iii) With Chinese Bamboo
(iv) With Thuja / Ixora
EDGE PLANTING / INTERNAL HEDGE Supplying and planting of suitable plant materials for edge making / Internal hedge(20 cm wide) including the preparation of the ground by mixing organic manure and fertilizers as per specification and necessary maintenance for a period of one year from the date of planting complete as specified and directed . TREE PLANTING Supplying and planting of ornamental trees (1'-0" height sapling) including pit making ( 60 cm x 60 cm x 60 cm ), filling the pit with appropriate soil media, manure and fertilizers as per specification and necessary maintenance for a period of one year from the date of planting complete as specified and directed . SHADE TREE (A) Neem / Mahaneem / Beef wood / Bakul / Acacia / Siris / Devils tree / Kadam / Palash / Pink Cassia / peepal / Silver oak / Simalu / Ajar
(B) Kanchan / Nahar / Arjunu
(C) Sonaru
(D) Bottle Brush / Nil Gulmohar / Debadaru / Weeping Willow
(E) Ravenala
(F) Paine
(G) Christmas tree / Kuki
Flowering Tree (A) Gulmohar / Ashok
(B) Kanchan
SHRUB PLANTING Supplying and planting of ornamental shrub ( below 1'-0" height ) including pit making ( 60 cm x 60 cm x 60 cm ), filling the pit with appropriate soil media, manure and fertilizers as per specification and necessary maintenance for a period of one year from the date of planting complete as specified and directed . (A) Radhachura / Krishnachura / Rat ki rani / Ixora / Jetuka
(B) Allmanda / Khorika zai / May flower / Kamini / Kathanda / Tecoma / Acalypha / Bougainvillea / Dracaena / Togor / Nilakantha / Mussaenda
(C) Korobi / Azalea
(D) Thuja
(E) Poinsettia / Forget me not
Construction of a pergola ( Width = 2.0 m, Height of the side posts = 1.8 m, Height at the apex = 2.8 m) with angle iron of size 50 mm x 50 mm x 5 mm (placing at 2000 mm apart ) embedding the iron posts in P.C.C. base ( not less than 600 mm) covering at the top and sides by chain link fencing, painting one coat of primer and two coats of paint including supplying and planting of flowering climbers as enclosed from both sides ( 3 nos. per metre in one side ) of the pergola to facilitate climbing by pit making (30 cm x 30 cm x 30 cm) filling the pit with the mixture of soil and organic manure and necessary maintenance by trimming etc complete as specified and directed by the department. (P.C.C. and soling to be measured and paid separately)
Supplying and placing of orchid house of size 3.00 m x 1.5 m x 2.00 m with tub stand, make of 15 mm dia. G.I. Pipe with M.S. rod, M.S. flat etc. including roof frame, painting two coats, covering the roof with 75 % heat absorbing black nets and three sides with wire net complete as directed and specified.
Edging with bricks laid dry lengthwise including excavation, refilling, consolidating with hand packing and spreading neatly surplus earth within a lead of 50 m.
Half brick circular tree guard internal diametre 1.25 m and height 1.2 m above ground and 0.02 m below ground bottom two coarses laid dry and top three coarses in cement mortar 1:6 and the intermediate coarses being in dry honey comb masonry as per design complete.
Making tree guard 53 cm dia and 1.3 m high as per design from empty coal tar drums including providing and fixing 2 nos. M.S. sheet rings (50 x 0.50) mm with rivets complete in all respects including painting inside and outside of tree gaurd .
Providing, fitting, fixing 20 mmx 50 mm mesh expanded metal wall of 18 gauge (1.2 mm thickness) in sal wood dressed frame not more than 1.20 m centre to centre including sal wood beading of 50 mm x 25 mm size sides chamfered , fitted with necessary wood screws spaced not more than 400 mm apart etc. complete as directed (sal wood frame to be measured and paid separately).
Providing, fitting and fixing wire netted wall with 13 mm hexagional mesh made of 20 gauge (0.95mm) over hollock wood dressed frame not more than 600 mm apart including hollock wood beading of 50 mm x 25 mm size sides chamfered , fitted with necessary wood screws spaced not more than 300 mm apart etc. complete as directed (Hollock wood frame to be measured and paid separately).
Piping Supplying fitting and fixing Pipes with all necessary fittings in exposed or in trenches including trenching and refilling the same etc complete as directed A) G.I. pipe with GI fittings a) TATA / SAIL (Medium) iii) 25mm diameter
v) 40 mm diameter
vi) 50mm diameter
Construction of R.C.C. ring well of 1200mm inside diameter including supplying necessary ring of 75mm thick and 500mm high of prop 1:2:4 reinforced with 8mm dia M.S. rod at 230mm c/c vertically and 5nos of 8mm dia bar horizontally along with R.C.C. well curb of size 400mm high and 100mm thick at top and 50mm thick at bottom in prop. 1:2:4 reinforced with 5nos of 8mm dia rod at 200mm c/c vertically including sinking of R.C.C. ring to a required depth bailing out water, mud etc. if necessary and fitting and fixing of R.C.C. kerb and ring in proper position with cement mortar of prop. 1:2 including with fitting in sides by sand in layer not more than 150mm and duly compacting the same up to the platform level complete as directed by the department. (c) Above 15.00m up to 20.00m depth.
Tube Well Labour for sinking tube well with 40mm (internal) dia G.I. Pipes up to having strata, having potable water including fitting and fixing strainer hand pump and other accessories as directed complete as in any soil.
Labour for test boring with 40mm (internal) dia G.I. Pipes including keeping surplus of earth and every 2.00m after first 3.00m depth and delivering the same in nearest P.W.D. camp in the small tin container (container, scaffolding, tools etc. will have to be arranged by the contractor at his own cost).
Supplying fitting and fixing Hand pump for 40 mm dia tube well with all accessories complete as directed. ii) Mayur
Labour for boring hole for inserting tube well pipes through different soil/ rock media including hire charges of drill pipes, scaffolding, tools and plants as necessary and taking out the same and lowering pipes, fittings complete as directed by the Department. vi) Bore hole of 200mm diameter
Supplying, fitting and fixing pipes plain/bevel ended for casing, conforming to relevant IS codes of practice including supplying and fitting of tube well accessories, lowering of assembly pipes concentrically in the borehole followed by supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department. G.I. pipe a) TATA / SAIL (Medium) socket should be welded to the pipes. vi) 150mm diameter
Supplying fitting and fixing brass Tez filter 2.00 metre long.
Supplying fitting and fixing check valve (non return valve) including thread to pipes. vii) 100mm diameter
Development of the tube well with compressor or by over pumping unit for 48 hours till sand free discharge is obtained
Flushing, clearing, washing and watering of the tube well
Cast iron Park Bench
Tube Well Labour for sinking tube well with 40mm (internal) dia G.I. Pipes up to having strata, having potable water including fitting and fixing strainer hand pump and other accessories as directed complete as in any soil.
Labour for test boring with 40mm (internal) dia G.I. Pipes including keeping surplus of earth and every 2.00m after first 3.00m depth and delivering the same in nearest P.W.D. camp in the small tin container (container, scaffolding, tools etc. will have to be arranged by the contractor at his own cost).
Supplying fitting and fixing Hand pump for 40 mm dia tube well with all accessories complete etc. i) Maya popular - 6
Supplying, fitting and fixing lift and force Maya hand pump of approved with all accessories complete as directed by the Department..
Labour for boring hole for inserting tube well pipes through different soil/ rock media including hire charges of drill pipes, scaffolding, tools and plants as necessary and taking out the same and lowering pipes, fittings complete as directed by the Department.x) Bore hole of 300mm diameter
Supplying, fitting and fixing pipes plain/bevel ended for casing, conforming to relevant IS codes of practice including supplying and fitting of tube well accessories, lowering of assembly pipes concentrically in the borehole followed by supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department. G.I. pipe a) TATA / SAIL (Medium) socket should be welded to the pipes. vi) 150mm diameter
Supplying, fitting and fixing suction pipes plain/bevel ended, conforming to relevant IS codes of practice including supplying and fitting of accessories, lowering of assembly pipes concentrically in the casing pipes complete as directed. A) G.I. pipe a) TATA/SAIL (Medium)socket should be welded to the pipes. iv) 50mm diameter
Supplying fitting and fixing GI filter 2.00 metre long.
Development of the tube well with compressor or by over pumping unit for 48 hours till sand free discharge is obtained
Flushing, clearing, washing and watering of the tube well
Supplying including installation, connection as approved by the Deptt., testing and commissioning of SUBMERSIBLE PUMP SET 3 (Three Phase) with steel cable rope and submersible cable complete as directed and specified by the deptt.Three phase Submersible motor pump set (Texmo / Crompton Greaves/Aquatic/CRI/V-Guar suitable for 100 mm bore well and above. 1 HP STAGE 5 to 18 with MCB controlled Submersible motor pump set control panel.
Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco /Anchor or Equivalent Make as approved by the Deptt.) in surface with flat ISI marked casing 'n' capping (AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) system including earth continuity.With 3 x 6 sq.mm. + earth continuity with2x 4 sq. mm. cable in flat 25mm ISI marked casing 'n' capping system.
Wiring for 5/6 pin 16 Amps power plug point with 4 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface flat 19 mm ISI marked casing 'n' capping (AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) system including earth continuity with 2.5 sq. mm cable to the 3rd pin of the socket as required complete.Long point up to 10.00 metre. Length.
Marjit Basumatary
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid