Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance 17TH FLOOR UNIT NO 1 TOWER 1 PS SRIJAN CORPORATE TECH PARK PLOT NO 2 BLOCK EP GP SECTOR V SALT LAKE KOLKATA WEST BENGAL 700091 | KOLKATA | KOLKATA | WEST BENGAL | 700091 | Admitted-Finance |
| 2 | Rejected-Technical 2 7 MEGHAL INDUSTRIAL ESTATE DEVIDAYAL ROAD MULUND WEST MUMBAI MAHARASHTRA 400080 | MUMBAI | MUMBAI | MAHARASHTRA | 400080 | Rejected-Technical NOT ACCEPTABLE |
Tender Value
Refer Docs
Closing Date
16 Dec 2022, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Balakrishnan Rangaraju
TECHNIP ENERGIES INDIA LTD, CHENNAI
110V DC UPS FOR NUMALIGARH REFINERY EXPANSION PROJECT
2022_NRL_715275_2
TP/082176C/NRL/PQ/063
Open Tender
Electrical Goods/Equipment
Supply
240 days
NUMALIGARH
Please refer Tender documents.
7 documents required · 7 mandatory
₹0
Exempted
10 Mar 2023
2 Dec 2022
17 Dec 2022
2 Dec 2022
16 Dec 2022
7 Dec 2022
2 Dec 2022 - 5 Dec 2022
DC UPS SYSTEM (SMPS), 110V, Parallel Redundant type 110V DC SMPS system consisting of 2 x 100% float cum boost charger in parallel redundant configuration, including Condition monitoring as detailed in the specification TP-1ZZZA-EL-SPE-0017 and Cell booster as per SLD & duty cycle as per requisition documents and shall include testing after erection, precommissioning and commissioning.
DC UPS SYSTEM (SMPS), 110V, Single non-redundant type 110V DC SMPS system consisting of 1 x 100% float cum boost charger in single non-redundant configuration, including Condition monitoring as detailed in the specification TP-1ZZZA-EL-SPE-0017 and Cell booster as per SLD & duty cycle as per requisition documents and shall include testing after erection, precommissioning and commissioning.
DC UPS SYSTEM (SMPS), 110V, Parallel Redundant type 110V DC SMPS system consisting of 2 x 100% float cum boost charger in parallel redundant configuration, including Condition monitoring as detailed in the specification TP-1ZZZA-EL-SPE-0017 and Cell booster as per SLD & duty cycle as per requisition documents and shall include testing after erection, precommissioning and commissioning.
DC UPS SYSTEM (SMPS), 110V, Single non-redundant type 110V DC SMPS system consisting of 1 x 100% float cum boost charger in single non-redundant configuration, including Condition monitoring as detailed in the specification TP-1ZZZA-EL-SPE-0017 and Cell booster as per SLD & duty cycle as per requisition documents and shall include testing after erection, precommissioning and commissioning.
DC UPS SYSTEM (SMPS), 110V, Parallel Redundant type 110V DC SMPS system consisting of 2 x 100% float cum boost charger in parallel redundant configuration, including Condition monitoring as detailed in the specification TP-1ZZZA-EL-SPE-0017 and Cell booster as per SLD & duty cycle as per requisition documents and shall include testing after erection, precommissioning and commissioning.
DC UPS SYSTEM (SMPS), 110V, Single non-redundant type 110V DC SMPS system consisting of 1 x 100% float cum boost charger in single non-redundant configuration, including Condition monitoring as detailed in the specification TP-1ZZZA-EL-SPE-0017 and Cell booster as per SLD & duty cycle as per requisition documents and shall include testing after erection, precommissioning and commissioning.
DC UPS SYSTEM (SMPS), 110V, Parallel Redundant type 110V DC SMPS system consisting of 2 x 100% float cum boost charger in parallel redundant configuration, including Condition monitoring as detailed in the specification TP-1ZZZA-EL-SPE-0017 and Cell booster as per SLD & duty cycle as per requisition documents and shall include testing after erection, precommissioning and commissioning.
DC UPS SYSTEM (SMPS), 110V, Single non-redundant type 110V DC SMPS system consisting of 1 x 100% float cum boost charger in single non-redundant configuration, including Condition monitoring as detailed in the specification TP-1ZZZA-EL-SPE-0017 and Cell booster as per SLD & duty cycle as per requisition documents and shall include testing after erection, precommissioning and commissioning.
DC UPS SYSTEM (SMPS), 110V, Parallel Redundant type 110V DC SMPS system consisting of 2 x 100% float cum boost charger in parallel redundant configuration, including Condition monitoring as detailed in the specification TP-1ZZZA-EL-SPE-0017 and Cell booster as per SLD & duty cycle as per requisition documents and shall include testing after erection, precommissioning and commissioning.
DC UPS SYSTEM (SMPS), 110V, Single non-redundant type 110V DC SMPS system consisting of 1 x 100% float cum boost charger in single non-redundant configuration, including Condition monitoring as detailed in the specification TP-1ZZZA-EL-SPE-0017 and Cell booster as per SLD & duty cycle as per requisition documents and shall include testing after erection, precommissioning and commissioning.
DC UPS SYSTEM (SMPS), 110V, Parallel Redundant type 110V DC SMPS system consisting of 2 x 100% float cum boost charger in parallel redundant configuration, including Condition monitoring as detailed in the specification TP-1ZZZA-EL-SPE-0017 and Cell booster as per SLD & duty cycle as per requisition documents and shall include testing after erection, precommissioning and commissioning.
DC UPS SYSTEM (SMPS), 110V, Parallel Redundant type 110V DC SMPS system consisting of 2 x 100% float cum boost charger in parallel redundant configuration with integral DCDB capable of delivering 110V and 48V DC using 110V to 48V converter, including Condition monitoring as detailed in the specification TP-1ZZZA-EL-SPE-0017 and Cell booster as per SLD & duty cycle as per requisition documents and shall include testing after erection, precommissioning and commissioning.
DC UPS SYSTEM (DC distribution panel), 110V DC, single front, non-draw out, compartmentalized DB for DC UPS having one incomer and outgoers as per SLD & requisition documents and shall include testing after erection, pre-commissioning and commissioning.
DC UPS SYSTEM (DC distribution panel), 110V DC, single front, non-draw out, compartmentalized DB for DC UPS having one incomer and outgoers as per SLD & requisition documents and shall include testing after erection, pre-commissioning and commissioning.
DC UPS SYSTEM (DC distribution panel), 110V DC, single front, non-draw out, compartmentalized DB for DC UPS having one incomer and outgoers as per SLD & requisition documents and shall include testing after erection, pre-commissioning and commissioning.
DC UPS SYSTEM (DC distribution panel), 110V DC, single front, non-draw out, compartmentalized DB for DC UPS having one incomer and outgoers as per SLD & requisition documents and shall include testing after erection, pre-commissioning and commissioning.
DC UPS SYSTEM (DC distribution panel), 110V DC, single front, non-draw out, compartmentalized DB for DC UPS having one incomer and outgoers as per SLD & requisition documents and shall include testing after erection, pre-commissioning and commissioning.
DC UPS SYSTEM (DC distribution panel), 110V DC, single front, non-draw out, compartmentalized DB for DC UPS having one incomer and outgoers as per SLD & requisition documents and shall include testing after erection, pre-commissioning and commissioning.
DC UPS SYSTEM (DC distribution panel), 110V DC, single front, non-draw out, compartmentalized DB for DC UPS having one incomer and outgoers as per SLD & requisition documents and shall include testing after erection, pre-commissioning and commissioning.
DC UPS SYSTEM (DC distribution panel), 110V DC, single front, non-draw out, compartmentalized DB for DC UPS having one incomer and outgoers as per SLD & requisition documents and shall include testing after erection, pre-commissioning and commissioning.
DC UPS SYSTEM (DC distribution panel), 110V DC, single front, non-draw out, compartmentalized DB for DC UPS having one incomer and outgoers as per SLD & requisition documents and shall include testing after erection, pre-commissioning and commissioning.
DC UPS SYSTEM (DC distribution panel), 110V DC, single front, non-draw out, compartmentalized DB for DC UPS having one incomer and outgoers as per SLD & requisition documents and shall include testing after erection, pre-commissioning and commissioning.
DC UPS SYSTEM (DC distribution panel), 110V DC, single front, non-draw out, compartmentalized DB for DC UPS having one incomer and outgoers as per SLD & requisition documents and shall include testing after erection, pre-commissioning and commissioning.
DC UPS SYSTEM (DC distribution panel), 110V DC, single front, non-draw out, compartmentalized DB Integrated with DC UPS having one incomer and outgoers as per SLD & requisition documents and shall include testing after erection, pre-commissioning and commissioning.
Battery Set for UPS System, Vented Ni- Cd Type Set of Ni-Cd type Battery Bank (2 X 100%) for 1 hour backup (duty cycle as per requisition documents) along with Battery rack and other accessories as per SLD & requisition documents and shall include testing after erection, pre-commissioning and commissioning.
Battery Set for UPS System, Vented Ni- Cd type Set of Ni-Cd type Battery Bank (1 x 100%) for 1 hour backup (duty cycle as per requisition documents) along with Battery rack and other accessories as per SLD & requisition documents and shall include testing after erection, pre-commissioning and commissioning.
Battery Set for UPS System, Vented Ni- Cd Type Set of Ni-Cd type Battery Bank (2 X 100%) for 1 hour backup (duty cycle as per requisition documents) along with Battery rack and other accessories as per SLD & requisition documents and shall include testing after erection, pre-commissioning and commissioning.
Battery Set for UPS System, Vented Ni- Cd type Set of Ni-Cd type Battery Bank (1 x 100%) for 1 hour backup (duty cycle as per requisition documents) along with Battery rack and other accessories as per SLD & requisition documents and shall include testing after erection, pre-commissioning and commissioning.
Battery Set for UPS System, Vented Ni- Cd Type Set of Ni-Cd type Battery Bank (2 X 100%) for 1 hour backup (duty cycle as per requisition documents) along with Battery rack and other accessories as per SLD & requisition documents and shall include testing after erection, pre-commissioning and commissioning.
Battery Set for UPS System, Vented Ni- Cd type Set of Ni-Cd type Battery Bank (1 x 100%) for 1 hour backup (duty cycle as per requisition documents) along with Battery rack and other accessories as per SLD & requisition documents and shall include testing after erection, pre-commissioning and commissioning.
Battery Set for UPS System, Vented Ni- Cd Type Set of Ni-Cd type Battery Bank (2 X 100%) for 1 hour backup (duty cycle as per requisition documents) along with Battery rack and other accessories as per SLD & requisition documents and shall include testing after erection, pre-commissioning and commissioning.
Battery Set for UPS System, Vented Ni- Cd type Set of Ni-Cd type Battery Bank (1 x 100%) for 1 hour backup (duty cycle as per requisition documents) along with Battery rack and other accessories as per SLD & requisition documents and shall include testing after erection, pre-commissioning and commissioning.
Battery Set for UPS System, Vented Ni- Cd Type Set of Ni-Cd type Battery Bank (2 X 100%) for 1 hour backup (duty cycle as per requisition documents) along with Battery rack and other accessories as per SLD & requisition documents and shall include testing after erection, pre-commissioning and commissioning.
Battery Set for UPS System, Vented Ni- Cd type Set of Ni-Cd type Battery Bank (1 x 100%) for 1 hour backup (duty cycle as per requisition documents) along with Battery rack and other accessories as per SLD & requisition documents and shall include testing after erection, pre-commissioning and commissioning.
Battery Set for UPS System, Vented Ni- Cd Type Set of Ni-Cd type Battery Bank (2 X 100%) for 1 hour backup (duty cycle as per requisition documents) along with Battery rack and other accessories as per SLD & requisition documents and shall include testing after erection, pre-commissioning and commissioning.
Battery Set for UPS System, Vented Ni- Cd Type Set of Ni-Cd type Battery Bank (1 x 100%) for 30 minutes backup (duty cycle as per requisition documents) along with Battery rack and other accessories as per SLD & requisition documents and shall include testing after erection, pre-commissioning and commissioning.
Miscellaneous Battery isolation breaker for each battery bank - flame proof (ex-d) suitable for installation in gas group II-C as per SLD & requisition documents
Copper cables Copper cables - including lug and DC gland for interconnection of UPS system and its DCDB & UPS system and its battery - as per SLD & requisition documents
Special Tools and Tackles as per Manufacturer’s recommendation for the above 110V SMPS based DC UPS
Special Tools and Tackles as per Manufacturer’s recommendation for the above 110V DC UPS Battery Bank. Other accessories (like Aprons and gloves) for safe and proper commissioning, operation and maintenance of the battery bank.
Special Tools and Tackles as per Manufacturer’s recommendation for the above 110V DCDB
Pre-Commissioning / Commissioning / Start-Up Spares As per Manufacturer’s recommendation for the above 110V SMPS based DC UPS
Pre-Commissioning / Commissioning / Start-Up Spares As per Manufacturer’s recommendation for the above 110V DC UPS Battery Bank
Pre-Commissioning / Commissioning / Start-Up Spares As per Manufacturer’s recommendation for the above 110V DCDB
Training to 2 Nos. of Owner personnel at OEM’s factory for the entire Package (Including Condition monitoring).
Training to 10 Nos. of Owner personnel at NREP Site for the entire Package (Including Condition monitoring).
Commissioning / Support Engineer from OEM shall be stationed at NREP Site for the duration of 1 month from the date of commissioning & handover for the entire package
Supervision services for Installation for the entire package.
Cost for Additional Warranty period of 12 Months ( as per Note 12)
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .