| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹89.1 LAccepted-AOC NO 68 ANJANEYA TEMPLE CROSS OPP M S RAMAIAH HOSPITAL NEW BEL ROAD BANGALORE 560 094 | BENGALURU URBAN | KARNATAKA | 560094 | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹95.4 L+₹6.3 L (7.08%)Rejected-Finance KALIAPPA COMPLEX THRICHY ROAD RANGANATHAPURAM SULUR COIMBATORE 641 402 | COIMBATORE | COIMBATORE | TAMIL NADU | 641402 | L2 | Rejected-Finance BEING NOT LOWEST TENDER | |
| 3 | L3₹1.0 Cr+₹13.1 L (14.7%)Rejected-Finance 121004 | L3 | Rejected-Finance BEING NOT LOWEST TENDER | |
| 4 | L4₹1.2 Cr+₹33.6 L (37.7%)Rejected-Finance DOOR NO 6 1 JOTHI NAGAR 6TH STREET VARATHARAJAPURAM UPPLIPALAYAM PO COIMBATORE 641015 | COIMBATORE | COIMBATORE | TAMIL NADU | 641015 | L4 | Rejected-Finance BEING NOT LOWEST TENDER | |
| 5 | Rejected-Technical | - | Rejected-Technical NOT ENLISTED IN PARTICULAR CAT |
Tender Value
Refer Docs
EMD Value
₹1.7 L
Closing Date
22 Dec 2020, 6:00 pmClosed
GE AF SULUR
Garrison Engineer AF Sulur Military Engineer Services Kangayampalayam Post Sulur Coimbatore 641 401
REPAIR MAINT OF CENTRAL AC PLANT COMPRESSOR COOLING APPLIANCE VARIOUS TYPES OF ACs AND OTHER MISC E M WORKS AT AFS SULUR
2020_MES_398071_1
8381/E8
Open Tender
Miscellaneous Works
Item Rate
334 days
GE AF SULUR
Please refer Tender documents.
9 documents required · 9 mandatory
₹1,000
Yes
GE AF SULUR
₹1.7 L
Yes
11 Jan 2021
25 Nov 2020
23 Dec 2020
25 Nov 2020
22 Dec 2020
16 Dec 2020
25 Nov 2020 - 15 Dec 2020
Amount
SCHEDULE A BOQ
Taking down old unserviceable scroll type compressor of capacity 8 TR including supply and replacement of same capacity of compressor of Make Emerson Climate Technologies or equivalent make for AC plant at location : P-16 (Clean Room) Note:- (a) Compressor shall be purchased from manufacturer/ authorised dealer of the manufacturer. Compressor shall be in sealed condition and shall bear warranty for 12 months from the date of purchase.
Supply and replacement of unserviceable microprocessor unit of 3X30TR AC plant at Rubber store of existing make/ brand of defective components/ spare part or any reputed suitable make as approved by the Engineer-in-Charge.
Supply and replacement of unserviceable condensor fan motor of capacity 3 phase 2HP ,935 Rpm,suitable for AC plant of capacity 3X30 TR of Make :-Hindustan or existing make/ brand of defective components/ spare part or any reputed suitable make as approved by the Engineer-in-Charge.
S&F in repair Dehumidifier Sensor with control board of existing make/ brand of defective components/ spare part or any reputed suitable make as approved by the Engineer-in-Charge
M&L for scrapping of old painting by wire brush and cleaning/preparation of the surface including providing one coat of red oxide and two coat of synthetic enamel spray painting and writing of suction discharge pressure/arrow marks of gas and water line by white paint on Air cooled chiller package unit including compressor and compressor motor - 3 Nos, AHU motor - 1 No, Chiller pump - 2 Nos, condenser motors-6 Nos, refrigerent lines & control panel boards complete all as per direction of Engineer -in-charge at Rubber Store AC Plant.
Taking down old unserviceable scroll type compressor of capacity 6 TR including supply and replacement of same capacity of compressor of Make Emerson Climate Technologies or equivalent make for AC plant at location : AVRO/ CRRW Note:- (a) Compressor shall be purchased from manufacturer/ authorised dealer of the manufacturer. Compressor shall be in sealed condition and shall bear warranty for 12 months from the date of purchase.
Providing insulation on and around suction and discharge copper tube of size 3/8"/ 5/8" with 6mm thick flexible thermocol heat resistance duly wrapped with sticking tape and finally covered with flexible PVC conduit of 50mm bore complete including taking down existing one all as specified and as directed.
Disconnecting electric connection from defective blower/ fan motor and taking out from unit capacity 8.3 TR of existing make and transporting to workshop after getting the gate pass from Engineer-in-Charge. Dismantling the burnt winding & rewinding of 1/6 to 1/8 HP double shaft blower motor with the existing size of super enemelled copper winding wire as per maunufactrer instructions including insulation, varnishing, greasing, testing complete and transporting back to the location from where it was disconnected and refixing the same and testing complete all as specified and as directed.
Outdoor fan motor suitable for small shaft condensing coil including blade suitable for ductable AC of 8.3 TR complete all as specified and as directed. Make : LG / Tecumseh / Kirloskar.
Liquid line drier filter suitable for 8.3 ton ductable AC with necessary brazing work and charging the refrigerant after replacing the liquid line filter to obtain adequate cooling complete including taking down existing one all as specified and as directed. Note : Supply and charging refrigerent gas will be measured and paid seperately under relavent items. Make of drier filter: LG / Danfoss / Hitech
Carrying out pressure leak test of 8.3 ton ductable split type AC whenever required by nitrogen gas pressure for detecting leakage in cooling/condensing unit refrigerant pipe and repairing the leakage by welding or brazing of condensing/ cooling unit, refrigerant pipe and putting under pressure for leakage checking after repair of leaking pipe flushing out by N2 and CTC/ vaccumination complete all as specified and as directed. Note :- Supply & charging of refrigerant gas R-22/R-407C will be measured and paid for separately
Indoor blower motor for cooling coil including blower suitable for ductable AC 8.3 TR complete all as specified and as directed. Make : LG / Tecumseh / Kirloskar.
Air filter set suitable for 8.3 ton ductable split type AC complete including taking down existing one all as specified and as directed. Make : LG / Danfoss / Hitech
PCB (circuit plate) of in-door unit of 8.3 TR ductable split AC complete including taking down existing one all as specified and as directed.
Taking out of defective wiring of indoor/ outdoor unit of PCB, visual eye damp plates, fixing the new wiring in place of damaged items of capacity of AC 8.3 TR including matching the existing system all as specified and as directed.
Complete wiring kit for outdoor panel of ductable AC of capacity 8.3 Ton complete all as specified and as directed.
Reverse cycle valve suitable for cassette type AC of capacity 8.3 Ton complete including taking down existing one all as specified and as directed.
Low pressure switch for 8.3 ton ductable split type AC complete including taking down existing one all as specified and as directed. Make : LG / Danfoss / Hitech
Wall mount remote kit with wire and complete assembly suitable for ductable AC of 8.3 TR complete all as specified and as directed.
Thermal relay 20A, 415 Volt, single phase suitable for ductable split type AC of 8.3 TR capacity complete including taking down existing one all as specified and as directed. Make : LG / Tecumseh / Hitech/ Indo Asian/L&T.
Single phase preventor, 230 volt, 50 HZ, AC supply complete including taking down existing one all as specified and as directed. Make : L&T / Seimens / BCH
AC 4 Pole power contactor three phase of capacity 40 Amp suitable for LG 8.3 TR capacity ductable split type AC complete including taking down existing one all as specified and as directed.
Taking down of defective evaporator unit of 2 TR capacity Cassette type AC and supply & fixing new evaporator unit of the same capacity (Make: Toshiba/ LG/ Totaline or equivalent) with blower motor, front grill and connecting the cooper tubing by brazing, detecting leakage, rectifying the same and recharging with refrigerant gas as required to obtain adequate cooling complete all as specified and as directed. Note: Supply & charging of refrigerant gas will be measured and paid for separately
S&F in replacement condensing unit of Cassette type AC of capacity 2 TR capacity condensing/ outdoor unit complete with condensing coil, coil frame, wiring kit, starting and running capacitor, relay, condensing/ outdoor motor with blade complete all as specified and as directed Make: Toshiba/ LG/ Voltas or equivlent) Note : Supply and charging of refrigerent gas will be measured and paid for separetly.
Carrying out pressure leak test of 2 ton cassette type AC whenever required by nitrogen gas pressure for detecting leakage in cooling/condensing unit refrigerant pipe and repairing the leakage by welding or brazing of condensing/ cooling unit, refrigerant pipe and putting under pressure for leakage checking after repair of leaking pipe flushing out by N2 and CTC/ vaccumination complete all as specified and as directed. Note :- Supply & charging of refrigerant gas R-22/R-407C will be measured and paid for separately
Outdoor fan motor suitable for small shaft condensing coil including blade suitable for cassettte AC of 2 TR complete all as specified and as directed. Make : LG / Tecumseh / Kirloskar.
PCB (circuit plate) of in-door unit of 2.0 TR ductable split AC complete all as specified and as directed.
Thermal relay 7.5A, 230 Volt, single phase suitable for cassette type AC of 2 TR capacity complete all as specified and as directed. Make : LG / Hitech/Indo Asian/L&T/Tecumseh.
Reverse cycle valve suitable for cassette type AC of capacity 2 Ton complete all as specified and as directed.
Taking down and strip opening of old unserviceable sealed unit compressor of any make from cassttee type air conditioner by disconnecting cooling and condensor copper pipe and electric connection carefully and S&F new scroll compressor of capacity 4 ton including charging of refrigerant gas R-22/ R-407C upto required cooling and connecting all the copper pipes, electric connection and testing the AC complete all as specified and as directed. Make : LG/ Danfoss/ Sanyo/ Tecumseh/Kirloskar/ Comipro/Copeland. Note : Supply and charging refrigerent gas will be measured and paid seperately under relavent items
Taking down of defective evaporator unit of 4 TR capacity Cassette type AC and supply & fixing new evaporator unit of the same capacity (Make: Toshiba/ LG/ Totaline or equivalent) with blower motor, front grill and connecting the cooper tubing by brazing, detecting leakage, rectifying the same and recharging with refrigerant gas as required to obtain adequate cooling complete all as specified and as directed. Note: Supply & charging of refrigerant gas will be measured and paid for separately
S&F in replacement condensing unit of Cassette type AC of capacity 4 TR capacity condensing/ outdoor unit complete with condensing coil, coil frame, wiring kit, starting and running capacitor, relay, condensing/ outdoor motor with blade complete including taking down existing one all as specified and as directed Make: Toshiba/ LG/ Voltas or equivlent) Note : Supply and charging of refrigerent gas will be measured and paid for separetly.
Liquid line drier filter suitable for 4 TR cassette type AC with necessary brazing work and charging the refrigerant after replacing the liquid line filter to obtain adequate cooling complete including taking down existing one all as specified and as directed. Note : Supply and charging refrigerent gas will be measured and paid seperately under relavent items. Make of drier filter: LG / Danfoss / Hitech
Outdoor fan motor suitable for small shaft condensing coil including blade suitable for cassettte AC of 4 TR complete including taking down existing one all as specified and as directed. Make : LG / Tecumseh / Kirloskar.
Thermal relay 15A, 230 Volt, single phase suitable for cassette type AC of 4 TR capacity complete including taking down existing one all as specified and as directed. Make : LG / Hitech/Indo Asian/ L&T/ Tecumseh.
Carrying out pressure leak test of 4 ton cassette type AC whenever required by nitrogen gas pressure for detecting leakage in cooling/condensing unit refrigerant pipe and repairing the leakage by welding or brazing of condensing/ cooling unit, refrigerant pipe and putting under pressure for leakage checking after repair of leaking pipe flushing out by N2 and CTC/ vaccumination complete all as specified and as directed. Note :- Supply & charging of refrigerant gas R-22/R-407C will be measured and paid for separately
Pipe thermister suitable for cassette type AC of capacity 4 Ton complete all as specified and as directed.
Reverse cycle valve suitable for cassette type AC of capacity 4 Ton complete including taking down existing one all as specified and as directed.
PCB (circuit plate) of in-door unit of 4.0 TR ductable split AC complete including taking down existing one all as specified and as directed.
Removing the window/ split type AC upto 1.5/ 2 ton capacity of any make from any location for carrying out servicing complete as and when ordered and installing back at original location, testing and commissioning all as specified and as directed by Engineer-in-Charge. Note :- The rate of following deemed to be included in quoted rate :- a) Cleaning the body, evaporator and condenser with detergent, combing the pins and flushing with air blower b) Checking electrical connection, cleaning, Greasing, oiling, fan/blower motor, cleaning of air filter with blower c) Wrapping suction and discharge pipe with foam insulation and white roll ,changing drainage pipe when necessary d) The unit rate quoted by the tenderer inclusive for Removing, servicing, installation, commissioning and testing of all equipment’s, materials & labour, tools and plants, and back in on final position complete (e) The work shall be done by a specialized team of Engineer/Technicians of OEM.
S&F Hermetic sealed/Rotory new compressor for 2 TR split type AC capacity including disconnecting the electrical and refrigerant connection of defective sealed unit of split type AC of capacity 2 Ton and connection of all pipe line & charging of refrigerant and testing complete including taking down existing one all as specified and directed Make :- Voltas, LG, Samsung Note:- (a) Compressor shall be purchased from manufacturer/ authorised dealer of the manufacturer. Compressor shall be in sealed condition and shall bear warranty for 12 months from the date of purchase.
S & F Condenser coil (in replacement) after disconnecting the refrigerant connection of defective condenser coil unit of split type AC upto 2.0 TR and replacing the condenser coil unit connecting the same unit with refrigerant connections complete including taking down existing one all as specified and directed.
Supply and fix pollyurethin form insulation indoor to outdoor unit suilable for 1.5 Ton to 2 Ton split type A/C any type and at any location including taking down existing one
Over load relay (in replacement) suitable for split type Air Conditioner of any make up to 2.0 TR capacity, including taking down existing one all as specified and directed.
Remote assembly corded/cordless (in replacement) for any type and size of split type ACs, upto 2.0 TR including taking down existing one all as specified and directed.
Supply and fixing Blower motor (in replacement) suitable for split type Air Conditioner of any make up to 2 TR capacity including taking down existing unserviceable one, all as specified and directed. Make of fan motor: AUE/ GEC/Himsun.
Supply and fix PCB board of any make for indoor unit of split AC 1.5 Ton/ 2 Ton including taking down existing one all as specified and directed.
Supply and fixing Condenser Fan motor (in replacement) suitable for window type Air Conditioner of any make up to and including 1.5/2.0 TR capacity, including taking down existing one all as specified directed. Make of fan motor: AUE/GEC/Himsun.
Suction valve suitable for 1.5 Ton/2 Ton of split type AC of existing make
Supply and fix old UNSV indoor unit including blower fan , PCB board and all accessaries capacity 1.5/2.0 Ton split type A/C including taking down existing unserviceable one any type all as specifed and directed by Engineer-in-charge
Supply and fixing Filter (in replacement) suitable for split type Air Conditioner of any make upto 2 TR capacity, including taking down existing one all as specified and directed.
Supply and fix discharge valve suitable for 1.5 Ton/2 Ton of split type AC including taking down existing one.
DC blower fan motor for inverter split AC of 1.5 Ton to 2 Ton and including taking down existing unserviceable one of any capacity and at any location all as specified and directed.
Blower of indoor unit suitable for 1.5 Ton / 2 Ton split AC including taking down existing unserviceable one at any location all as specified and directed.
Supply and fixing Remote sensing unit (in replacement) for upto 2.0 TR split type AC including taking down existing unserviceable one all as specified and directed. Make : As per existing AC at the site.
S & F Copper tube (in replacement) 15 mm / 18 mm dia, superior quality suitable for refrigeration and suction lines of split ACs, drawn trough pipes/ fixed to walls/ laid on floor or roof all as specified and directed
Supply and fix metal frame stand factory made outdoor type to hold outdoor split unit of ACs including taking down existing one all as directed and specified.
S & F Copper tube, 9 mm bore (in replacement) superior quality suitable for refrigeration and discharge lines of split ACs, drawn trough pipes/ fixed to walls/ laid on floor or roof including taking down existing one all as specified and directed.
Filter (in replacement) suitable for window type Air Conditioner of any make up to 1.5/ 2 TR capacity including taking down existing one all as specified and directed.
Supply and fixing Front grill (in replacement) suitable for split type Air Conditioner of any make up to 2 TR capacity, including taking down existing one all as specified and directed.
Hermetic sealed/Rotory new compressor for split type AC upto and including 1.5 TR capacity (in replacement) including disconnecting the electrical and refrigerant connection of defective sealed unit of split type AC of capacity 1.5 Ton and connection of all pipe line & charging of refrigerant and testing complete including taking down existing one all as specified and directed Make :- Voltas, LG, Samsung Note:- (a) Compressor shall be purchased from manufacturer/ authorised dealer of the manufacturer. Compressor shall be in sealed condition and shall bear warranty for 12 months from the date of purchase.
Condenser coil (in replacement) after disconnecting the refrigerant connection of defective condenser coil unit of split type AC upto 1.5 TR and replacing the condenser coil unit connecting the same unit with refrigerant connections complete including taking down existing one all as specified and directed.
Supply and fixing flexible PVC pipe of suitable size for indoor unit drain water of split AC suitable for any type and any capacity.
M&L for Refrigerant gas, (R 407C) suitable for cooling equipments supplied and filled all as specified and directed.
Supply and fix 3 pin metal clad plug top 20 Amps, AC 230 volts for any type of AC including taking down existing unserviceable one all as specified and as directed.
Supply & fix metal clad switch socket single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20A concealed in walls. Make : Cat Pt No 607841 of Legrand or equivalent of Schnieder (Multi -9) or Siemens/L&T (Hegar).
Supply and fix dummy nut of dia 3/8" suitable for 1.5 Ton/2 Ton of split type AC
Supply and fix dully nut of dia 1/4" suitable for 1.5 Ton/2 Ton of split type AC
Supply and fix dummy nut of dia 5/8" suitable for 1.5 Ton/2 Ton of split type AC
Supply and fix dummy nut of dia 1/2" suitable for 1.5 Ton/2 Ton of split type AC
PVC insulated multi stranded copper conductor 3 core 2.5 sq.mm, including connecting up and taking down existing unserviceable cable of any description and size (in replacement) all as specified and directed.
M&L for shifting of Air Conditioner, window/Split type capacity up to 2 TR from existing location to new location as per user requirement and installing, toping up of gas, replacement of copper tubing connecting up, commissioning and testing complete all as specified and as directed by Engineer-in-Charge. Note :- The rate for following works deemed to be included in quoted rate :- (a) Transportation of air conditioner any type any capacity from one to other location. (b) Fixing only base plate with necessary fixing material on stone / brick walls and as directed (c) Fixing only outdoor and indoor units as required and directed (d) Connecting indoor / outdoors units of split ACs with copper tubes, flairs nuts, warping suction and discharge lines with inclucating materials with necessary fixing arrangements such as bolts, nuts washers and clamps etc on walls (e) fixing PVC pipes 50mm dia for outlet of outdoor units to drain out dew water with necessary clamps. (f) Fixing of wall mounting voltage stabilizer of 3 KVA to 5 KVA capacity on the wall with necessary fixing arrangements such as bolts, nuts washers and clamps etc on wall. (g) Fixing PVC hose/ PVC pipes of 15mm sizes as reqd at site with necessary junction boxes, PVC bends etc. including two length of PVC copper cables of 4 sqmm size for electrical connection of ACs. (h) No additional payment shall be made for leakage of gas occuring during shifting of Air Conditioner and topping up of required gas. (j) Fixing of copper tubing of qty of required size.
Supply and fix flair nut of dia 5/8" suitable for 1.5 Ton/2 Ton of split type AC
Supply and fix flair nut of dia 1/2" suitable for 1.5 Ton/2 Ton of split type AC
Supply and fix flair nut of dia 3/8" suitable for 1.5 Ton/2 Ton of split type AC
Supply and fix flair nut of dia 1/4" suitable for 1.5 Ton/2 Ton of split type AC
Supply and fix flair nut of dia 1/16" suitable for 1.5 Ton/2 Ton of split type AC
M & L for pressure testing and rectifying the leakages found in the system of window/ split type ACs capacity up to 2 Ton capacity including vacumizing, charging and checking the gas pressure to desire level complete for satisfactory functioning all as specified and as directed. Note:Toping up of gas will be measured and paid seperately
S&F Hermetic sealed/Rotory new compressor for window type AC of capacity 1.5 Ton (in replacement) including disconnecting the electrical and refrigerant connection of defective sealed unit of window type AC of capacity 1.5 Ton and connection of all pipe line & charging of refrigerant and testing complete including taking down existing one all as specified and directed Make :- Voltas, LG, Samsung Note:- (a) Compressor shall be purchased from manufacturer/ authorised dealer of the manufacturer. Compressor shall be in sealed condition and shall bear warranty for 12 months from the date of purchase.
Supply and fixing Front grill (in replacement) suitable for window type Air Conditioner of any make up to 1.5 TR capacity, including taking down existing one all as specified and directed.
Supply and fix condenser fan blade suitable for 1 Ton / 1.5 Ton split/ window AC including taking down existing unserviceable one and all as specifed and directed.
Supply and fixing Thermostat (in replacement) suitable for window type Air Conditioner of any make up to 1.5 TR capacity, including taking down existing one all as specified and directed.
Supply and fixing Over load relay (in replacement) suitable for window type Air Conditioner of any make up to and including 1.5/ 2 TR capacity, including taking down existing one all as specified and directed.
Supply and fixing Blower motor (in replacement) suitable for window type Air Conditioner of any make up to 1.5/ 2 TR capacity including taking down existing unserviceable one all as specified and directed. Make of fan motor: AUE/ GEC/Himsun.
S & F Condenser coil (in replacement) after disconnecting the refrigerant connection of defective condenser coil unit of window type AC upto and including 1.5/ 2 Ton and replacing the condenser coil unit connecting the same unit with refrigerant connections complete including taking down existing one all as specified and directed.
Supply and fix overload protector for window/ split AC 1.5/2 Ton TR capacity including taking down existing unserviceable one all as specified and direced. Make: Indfoss
Inspection, checking adjustment and minor repair of unserviceable window type/ split type AC any type any capacity placed at any location includes repair/ replacement of defective parts such as checking of electrical connection, condenser, gas leakage, PCB, condenser fan blade, indoor unit, outdoor unit, compressor, PVC pipe etc., complete all as specified and as directed by Engineer-in-Charge. Note :- Repair/ replacement of unserviceable parts shall be measured and paid separately complete all as specified and as directed by Engineer-in-Charge.
Supply and fix single phase single pole contactor suitable for 1.5/ 2.0 split type AC all as specified and as directed.
Repair and maintenance of inverter type split AC of any capacity / any Make from any location including attending breakdown calls, routine maintenance and servicing ,testing and commissioning all as specified and directed here under :- a) Cleaning the body, evaporator and condenser with detergent, combing the pins and flushing with air blower. b) Checking electrical connection, cleaning, Greasing, oiling, fan motor, cleaning of air filter with blower. (c) Testing all copper tube ,joints, leads for any leaking and Top up with the refrigerant gas if necessary. (d) The work shall be done by a specialized team of Engineer/Technicians of OEM. (e) Nearly 50 number of inverter type split AC are installed at the distant height. To carryout servicing of these AC's special T&P (Boomer vechice) of height 24 meter will be required. The cost of arrangement of special T&P will be inclusive in quoted rate.
S&F PCB board of inverter type split type AC for 1.5 Ton/2 Ton including taking down existing unserviceable one at any location all as specified and as directed.
Taking out, inspection, checking adjustment and minor repair of unserviceable refrigerator 165/ 180/ 175/210/260/280/300/310/320/335 ltr capacity of any type any make for repair/ replacement of defective parts such as condenser, PVC pipe, loose electrical connection etc., cleaning, condenser unit of foreign particle and descaling with carbon di oxide gas to ensure smooth flow of refrigerating gas, reassembling the appliance, testing and placing in original position complete all as specified and as directed by Engineer-in-Charge. Note :- Repair/ replacement of unserviceable parts shall be measured and paid separately complete all as specified and as directed by Engineer-in-Charge.
M&L for pressure testing and rectifying the leakage found in the system of refrigerator of capacity 310 to 335 litres including vacuuming and charging the refrigerant (R 134a gas to the desired pressure and filling new compressor oil etc. complete for satisfactory functioning all as specified and as directed. Note:Topping up of gas will be measured and paid seperately
S&F hermetically sealed new compressor (in replacement) for 308 to 335 Ltr capacity of refrigerator including filling of refrigerant suitable and testing complete by disconnecting the electrical and refrigerant connection of defective sealed unit of Refrigerator compressor of capacity 308 to 350 litres. Make :- As per existing make of Refrigerator Note:- (a) Compressor shall be purchased from manufacturer/ authorised dealer of the manufacturer. Compressor shall be in sealed condition and shall bear warranty for 12 months from the date of purchase.
S&F in replacement condensing coil for refrigerator of capacity 310 to 335 Ltr complete all as specified and directed.
S & F Evaporator coil, suitable for refrigerator of 308 to 335 ltrs any make size and type (in replacement) all as specified and as directed.
M&L for pressure testing and rectifying the leakage found in the system of refrigerator of capacity 260 to 300 litres including vacuuming and charging the refrigerant (R 134a gas to the desired pressure and filling new compressor oil etc. complete for satisfactory functioning all as specified and as directed.Note:Topping up of gas will be measured and paid seperately
S&F hermetically sealed new compressor (in replacement) for 260 to 310 Ltr capacity of refrigerator including filling of refrigerant suitable and testing complete by disconnecting the electrical and refrigerant connection of defective sealed unit of Refrigerator compressor of capacity 165 to 255 litres. Make :- As per existing make of Refrigerator Note:- (a) Compressor shall be purchased from manufacturer/ authorised dealer of the manufacturer. Compressor shall be in sealed condition and shall bear warranty for 12 months from the date of purchase.
S&F in replacement condensing coil for refrigerator of capacity 260 to 310 Ltr complete all as specified and directed.
S & F Chiller tray (in replacement) suitable for Refrigerator of any make, 260 to 310 litres capacity, all as specified and directed.
S & F Evaporator coil, suitable for refrigerator of 260 to 300 ltrs any make size and type (in replacement) all as specified and as directed.
S & F Vegetable tray (in replacement) suitable for Refrigerator of any make, 260 to 310 litres capacity, all as specified and directed.
S&F ice superior quality plastic/PVC Ice cube tray for refrigerator of capacity 210 Ltrs to 310 ltrs complete all as specified and directed.
Supply and fix in repair electric bulb 20 watt 230v threaded type for refrigetator of Capacity 200 ltrs to 310 ltrs complete all as specified and directed.
Freezer compartment including door and accessories suitable for refrigeratorr 280, 300, 310 and 320 ltrs capacity refrigerator and including taking existing unserviceable one complete all as specified and as directed. Make : Godrej/LG/whirlpool
PVC shelf transparent type of tough plastic suitable for refrigerator of capacity 300 ltrs complete including taking down existing unserviceable one all as specified nd as directed. Make : Godrej/LG/Whirlpool
M&L for pressure testing and rectifying the leakage found in the system of refrigerator of capacity 165 to 260 litres including vacuuming and charging the refrigerant (R 134a gas to the desired pressure and filling new compressor oil etc. complete for satisfactory functioning all as specified and as directed.Note:Topping up of gas will be measured and paid seperately
S&F hermetically sealed new compressor (in replacement) for 165 to 260 Ltr capacity of refrigerator including filling of refrigerant suitable and testing complete by disconnecting the electrical and refrigerant connection of defective sealed unit of Refrigerator compressor of capacity 165 to 255 litres. Make :- As per existing make of Refrigerator Note:- (a) Compressor shall be purchased from manufacturer/ authorised dealer of the manufacturer. Compressor shall be in sealed condition and shall bear warranty for 12 months from the date of purchase.
S&F in replacement condensing coil for refrigerator of capacity 165 to 260 Ltr complete all as specified and directed.
S & F Chiller tray (in replacement) suitable for Refrigerator of any make, 165 to 260 litres capacity, all as specified and directed.
Supply and fix in repair magnetic beading for refrigerator of cap 165 ltrs to 335 ltrs complete all as specified and directed.
S & F Relay, box type, suitable for refrigerator of any make 165 to 335 litres capacity (in replacement) fixed in repairs, all as specified and directed.
S & F Evaporator coil, suitable for refrigerator of 165 to 260 ltrs any make size and type (in replacement) all as specified and as directed.
M & L for preparing the old painted surface of refrigerator of capacity 165 litres to 335 litres and spray painting with synthetic enamel paint of approved colour all as specified and directed.
S & F Vegetable tray (in replacement) suitable for Refrigerator of any make, 165 to 260 litres capacity, all as specified and directed.
Freezer compartment including door and accessories suitable for refrigerator 165/175 ltrs capacity refrigerator and including taking down existing one complete all as specified and as directed. Make : Godrej/LG/whirlpool
S & F Thermostat, suitable for refrigerator of any make 165 to 335 litres capacity (in replacement) all as specified and directed.
S & F in replacement Gasket, suitable for door of Refrigerator of any make, 165 to 260 litres capacity, fixed in repairs all as specified and directed.
Multi capacitors 2 µfd for cooling appliances including taking down existing unserviceable one complete all as specified and as directed. Make :KELTRON/SRIRAM/EPCOS/BHEL
Filter of refrigerator including taking down existing unserviceable one complete all as specified and as directed.
Timer and sensor of Refrigerator including taking down existing unserviceable one complete all as specified and as directed as per Make of Refrigerator
Over load protector for refrigerator including taking down existing unserviceable one any description complete all as specified and as directed..
Copper capillary tube suitable for refrigerator including taking down existing unserviceable one, any description complete all as specified and directed.
Starting relay suitable for refrigerator including taking down existing unserviceable one complete all as specified and as directed Make : SRIRAM/GODREJ/RANUTROL
Multi capacitors 4 µfd for cooling appliances including taking down existing unserviceable one all as specified and as directed. Make :KELTRON/SRIRAM/EPCOS/BHEL
Multi capacitors 2.5 µfd for cooling appliances including taking down existing unserviceable one complete all as specified and as directed. Make :KELTRON/SRIRAM/EPCOS/BHEL
M&L for dismantling the transformer from the stabilizers of 4 KVA and removing the old / burnt transformer and replaced with new transformer
M&L for dismantling the transformer from the stabilizers of 5 KVA and removing the old / burnt transformer and replaced with new transformer
Replacement of following spare parts for 4 KVA to 5 KVA capacity stabilizers (a) Relay set ( set of two )
(b) PCB ( Printed circuit board)
S&F Digital voltmeter 0-250volt (in replacement) for voltage stabilizers any type as per existing all as specified and directed
Comprehensive maintenance of 3 phase oil cooled servo stabilizer of Make : BEC with input variation between 340V to 400V with output stabilized at 415 Volts of capacity 75KVA with all spares including isolating stabilizer from system, Opening up, examining the accessories parts,cleaning,soldering as required and testing and connecting back with the system. periodical maintenance as recommended by the original manufacturer complete all as specified and directed, Location TRCL plant
Comprehensive maintenance of 3 phase oil cooled servo stabilizer of Make : BEC with input variation between 340V to 400V with output stabilized at 415 Volts of capacity 50KVA with all spares including isolating stabilizer from system, Opening up, examining the accessories parts,cleaning,soldering as required and testing and connecting back with the system. periodical maintenance as recommended by the original manufacturer complete all as specified and directed. Location T/51 plant
Comprehensive maintenance of 3 phase oil cooled servo stabilizer of Make : Vinitec with input variation between 340V to 470V with output stabilized at 415 Volts of capacity 250KVA with all spares including isolating stabilizer from system, Opening up, examining the accessories parts, cleaning, soldering as required and testing and connecting back with the system. periodical maintenance as recommended by the original manufacturer complete all as specified and directed, Location MAFI Sub Stn No - 02
Note for Item No 133 to 135 :- (a) In above items, maintenance shall be done through authorised person of OEM. The contractor shall make AMC contract with the original manufacturer of servo stabilizer and the repairs/maintenance shall be carried out through the original manufacturers only. (b) The rate quoted shall be deemed to include for carried out all repairs to servo stabilizer noticed during the period 11 months.
Supply only Servo motor suitable for 50 to 75 KVA servo stablizer including taking down existing unserviceable one of any Make all as specified and directed.
Supply only Microprocessor board of servo stablizer of capacity 50KVA to 250KVA and including taking down existing one all as specified and as directed.
Supply only Bypass switch of servo stabilizer of capacity 50 to75 KVA including taking down existing unserviceable one of any Make all as specified and directed.
Supply only Buck Boost transformer of servostablizer of capacity 50KVA to 75KVA including taking down existing unserviceable one of any Make all as specified and directed..
Taking down aluminum/copper point wiring on & including hard wood battens, surface conduit and board/ blocks etc or through conduits for light, socket or power point, fan point complete (Taking down of fittings such as switches, sockets, bells, ceiling rose, holders , regulators, light fittings, MCB, lamps etc shall be measured and paid seperately) and making good the disturbed plaster surfaces of wall, floor, ceiling and painting 2 coat of white wash/distamber to meet the existing surface and removing materials and debris to reinstate the premise neat and clean complete all as specified and directed.
Point wiring complete with 1.5 sqmm single core PVC insulated, unsheathed fire retacable 1100 volts grade, multi stranded with copper conductor drawn through and incl PVC casing caping with accessories in wall/roof/ceiling etc incl MS modular terminal boxes, concealed surface to walls covered with modular plates with cover etc and 1.5 sqmm PVC insulated, unsheathed copper conductor multistranded cable 1100V grade as earth continuity conductor & connecting to common earth dolly all as specified for Make of Wire : Plaza/ Polycab/ Havells Make of Casing Capping : Polycab/Modi/ Presto Plast Note: (a) Switches, sockets outlets, blanking plate, Light fittngs, fans, bells & regulators will be measured and paid for separetely). (b) Connection of wire with switch, socket shall be through copper thumble (lugs) only.
One light point/fan/bell point controlled by one switch
All as per item No. 142 here in before but for One 3 pin socket out 5 amp on the same board
All as per item No. 142 here in before but for one switch socket outlet 3 pin 5 Amps on independent board
All as per Sl No 142 above but Wiring with 4 Sqmm copper multistranded unsheathed cable and 4 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently
Point wiring complete with 1.5 sqmm single core PVC insulated, unsheathed fire retacable 1100 volts grade, multi stranded with copper conductor drawn through and incl PVC Conduit with accessories in wall/roof/ceiling etc incl MS modular terminal boxes, concealed surface to walls covered with modular plates with cover etc and 1.5 sqmm PVC insulated, unsheathed copper conductor multistranded cable 1100V grade as earth continuity conductor & connecting to common earth dolly all as specified for Make of Cable : Plaza/ Polycab/ Havells Make of Conduit : Avon Plast/ Supreme/ Diplast Note: (a) Switches, sockets outlets, blanking plate, Light fittngs, fans, bells & regulators will be measured and paid for separetely). (b) Connection of wire with switch, socket shall be through copper thumble (lugs) only.
One light point/fan/bell point controlled by one switch
All as per item No 147 here in before but for One 3 pin socket out 5 amp on the same board
All as per item No. 147 here in before but for one switch socket outlet 3 pin 5 Amps on independent board
All as per Sl No 147 above but Wiring with 4 Sqmm copper multistranded unsheathed cable and 4 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently
Supply and fix modular switch 1 way 6 amp.1 module. Make : Legrand (Model- Arteor), ABB (Cheiron), Schneider (Ulti)
Supply and fix modular Socket, 6A - 2/3 pin combined 2 module. Make : Legrand (Model- Arteor), ABB (Cheiron), Schneider (Ulti)
Supply and fix modular switch 1 way 16 amp.1 module. Make : Legrand (Model- Arteor), ABB (Cheiron), Schneider (Ulti)
Supply and fix modular Socket, 16A - 2/3 pin combined 2 module. Make : Legrand (Model- Arteor), ABB (Cheiron), Schneider (Ulti)
Supply and Fix bell push, flush type
Supply and Fix bell push, modular type, 1 way
Supply and Fix ceiling rose 3 plates flush type 6 Amps,250 volts AC ISI marked.
4 feet surface mounted batten type 20W LED luminaire with emergency light output, shall be maximum 4 hours battery backup in case of power failure with Li battery, luminaire efficacy 100 lm/w with an operating voltage range from 140V - 270V, initial lumen at battery mode will reduce to 35 - 50%, charging time appox 8 - 12 hours. The luminaire shall have aluminium extruded main housing, PC LED front cover. The luminaire shall have a CCT of 6500K, CRI >80, Power factor >0.95, THD <30%, driver efficiency > 85%, electronic control gear, CC driver and 50,000 burning hours as per L70 B50 criteria. The luminaire shall be EMI/ EMC complaint and shall have open and short circuit protection, reverse polarity protection, internal surge protection of 3.0 KV, IP 20 ingress protection. Make :- Halonix Model No : HLB-08-20-CW-INV or equivalent of Philips/ Bajaj
Note for item No 159 :- (a) LED Chip make shall be Nichia, Osram, Cree, Lumilid, Seoul semiconductor. (b) The contractor shall submit to Engineer-in-Charge LM-80 and LM-79 report from the NABL approved lab of LED Chip used and luminaise respectively while getting sample and material approved. (c) The contractor shall also submit test report from the manufacture to comply with all requirements and specifications given in the contract. (d) The contractor shall submit warranty certificate from manufacturer for minimum 02 years.
Supply and fix single pole MCB 6 to 32 Amps, 240 v, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity conforming to IS 8828 of 1996 including taking down existing one all as specified (Make/Model : Lexic MCB of MDS Legrand Cat No :408587 to 408595 / Siemens/ Schnieder.
S & F PVC insulated multi stranded copper conductor 4 sqmm 4 core including connecting by using suitable size of lugs including taking down existing unserviceable cable of any description and size all as specified and directed.
Supply, installation, testing & commissioning of maintenance free chemical earthing system comprising 17mm dia copper bonded rod 3 mtr long horizontally pre welded T-terminal rod with provision for connection size of 50 x 150mm long, 6mm thickness with equal space either side, with 12mm dia hole of 02 numbers each on either side of the terminal clamp with 250 microns (average) coating thickness, tested and certified by CPRI India alongwith 50 Kg earth energizer compound and 10 litres earth resistance reducing liquid. The earthing energizer compound and resistance reducing earthing liquid shall be tested as per IEC-62561-7 read with ASTM G57-06, CI 3.4 A by any NABL accredited lab. The above mentioned rod shall be installed in 4-6 inch bore, 12 feet depth with a distance of minimum 3 meters between each installation all as directed. Make : Model HTSP 317 of safeTrode or equivalent in ISG Global/ ERICO.
The quoted rate shall also deemed to be included the following :- (i) Prior to installation of maintenance free chemical earthing, soil resistivity test to be carried out at the location where earthing work to be done in presence of Engr-in- Charge/JE (E/M),user and the report has to submit to Garrison Engineer with recommendation of manufacturer, if required additional interconnection of earthing (not more than 04 number of earthing) to achive earth result less then 1 Ohms. The arrangement done for soil resistivity testing and submission of report with recommendation deemed to be included in the quoted rate.
(ii) The description/ size/ qty of items mentioned in above are for indicating only however qty/ size may vary at site condition to maintain the earth resistance 1 ohm. The contractor shall quote rate by considering all factors.
(iii) Rate of earth energizer compound of 25 Kg of 02 bags and earth resistance reducing liquid 10 litre per cane for each pit deemed to be included in the quoted rate.
(iv) Resistivity of earth energizer compound and resistance reducing earthing liquid shall be certified by any NABL accredited lab carried out as per IEC-62561-7 read with ASTMG57-06, CI-3.4A and the certificate of same shall be submitted by the contractor before commencement of work.
(v) Earth enhancing material should not leach into the adjacent soil or underground water channels and its PH valve should be in neutral range complete all as specified and as directed. It should solidify when mixed with water and set like concrete.
(vi) Copper strip of size 20 x 3 mm should be fixed on proper post insulator at the instrument end ( copper strip will be measured and paid separately).
(vii) Testing of earth shall be carried out in presence of departmental and user representative and report shall be submitted to Garrison Engineer duly signed by all concern.
(viii) Earth resistance tester will be provided by the contractor. Tester should be calibrated from authorised company/ lab.
(ix) Earthing shall be tested after completion of work by the contractor in presence of Engr-in-charge, user and proper record shall be maintened duly signed by all concerned. After testing if the desired earth resistance of less than 1 Ohm is not obtained, the earthing will be redone at no extra cost to Govt. till desired result is obtained.
(x) The contractor shall given a written guarantee of minimum three years for maintaining the earth resistance less than 1 Ohm after certified date of completion.
(xi) No further maintenance or periodic watering or recharge shall be required in earthing during its guarantee period of over 03 years in all type of soil including soft/ disintegrated or hard rock.
(xii) During the guarantee period, if earth resistance is not maintained less than 1 ohm the contractor has to redo or rectify at no extra cost to Govt till desired result is mainained.
(xiii) A security deposit of value equal to 2.5 % of the rate quoted for chemical earthing per each earthing shall be retained from payment due to the contractor for the guarantee period.
(xiv) The electrode shall carry manufacturer's name .
(xv) The connection clamp shall be permanentlly welded to the copper bounded rod to avoid any kind of connectivity loss,.The pre-welded copper bounded rod shall not need any additional clamp for termination.
(xvi) The acceptable earth resistance at earth busbar/ test point shall not be more than 0.1 ohm.
(xvii) The contractor shall submit CPRI India certified document for copper bonded rod to ensure genuity of material.
(xviii) Sign board of mild steel 2 mm thick duly painted with two coats of synthetic enamel paint over a coat of red oxide Zinc chrome primer showing result of earthing should be fixed near the earth pit after completion as directed by engr -in- charge.
(xix) Earth work such as auguring and making good the surrounding area shall carried out in any type of soil.
Copper strip 20 x 3mm thick as earthing lead fixed to wall/roofs etc including taking down existing one all as directed. NOTE : All Joints should be joined by Exothermic Welding or Brazing.
Earth pit cover made of heavy duty poly plastic of high grade polypropylene tested and certified by any NABL accredited lab for load bearing capacity not less than 9.2 tonnes with top dia not less than 250mm, bottom dia not less than 330 mm and height not less than 260 mm dia for each electrode pit complete all as specified and directed. Make : Model SEPC 250 of SAFE TRODE/ Electrogrip Model/ EGTEK3LC of ISG Global or equivalent in ERICO. Note :- The contractor shall submit load bearing capacity certificate from the manufacturer.
M&L for pressure testing and rectifying the leakage found in the system of Deep freezer of capacity 320 litres including vacuuming and charging the refrigerantRefrigerant gas R-134 a gas to the desired pressure and filling new compressor oil etc. complete for satisfactory functioning all as specified and as directed.Note:Topping up of gas will be measured and paid seperately
S&F hermetic sealed new compressor (in replacement) 1/6 HP suitable for deep freezer of capacity 320 ltr including disconnecting the electrical and refrigerant connection of defective sealed unit of deep freezer 320 litres and connection of all pipe line & charging of refrigerant and testing complete all as specified and directed Note:- (a) Compressor shall be purchased from manufacturer/ authorised dealer of the manufacturer. Compressor shall be in sealed condition and shall bear warranty for 12 months from the date of purchase.
Copper capillary tube of Deep freezer including taking down existing unserviceable one, any description complete all as specified and as directed.
Condenser fan motor of Deep freezer including taking down existing unserviceable one complete all as specified and as directed.
Thermostat for Deep freezer including taking down existing unserviceable one complete all as specified and as drected. Make : Whirlpool/Renutrol.
Starting relay of Deep freezer including taking down existing unserviceable one complete all as specified and as directed. Make- Sriram/Godrej/Ranutrol
Filter for Deep freezer including taking down existing unserviceable one complete all as specified and as directed
Over load protector for Deep freezer including taking down existing unserviceable one, any description complete all as specified and as directed.
M&L for Refrigerant gas, (R 22) Freon suitable for cooling equipments supplied and filled all as specified and directed.
Multi capacitors 60 µfd for cooling appliances and including taking down existing one complete all as specified and as directed. Make :KELTRON/SRIRAM/EPCOS/BHEL
Multi capacitors 50+5 µfd for cooling appliances including taking existing unserviceable one complete all as specified and as directed. Make :KELTRON/SRIRAM/EPCOS/BHEL
M&L for dismantling the transformer from the voltage stabilizers of following capacity and removing the old / burnt transformer and replaced with new transformer (a) 0.5 KVA
Replacement of following spare parts for 1 KVA to 2 KVA capacity voltage stabilizers (a) Relay set ( set of two )
(b) PCB ( Printed circuit board)
Taking out, inspection, checking adjustment and minor repair of unserviceable water cooler 40/80/60/120/150/200 ltr capacity of any type any make for repair/ replacement of defective parts such as condenser, PVC pipe, loose water tap, float valve, loose electrical connection etc., cleaning condenser unit of foreign particle and descaling with carbon di oxide gas to ensure smooth flow of water cooler gas, reassembling the appliance, testing and placing in original position complete all as specified and as directed by Engineer-in-Charge. Note :- Repair/ replacement of unserviceable parts shall be measured and paid separately complete all as specified and as directed by Engineer-in-Charge.
M&L for pressure testing and rectifying the leakages found in the system of water cooler of capacity 150 litres and vacuuming and charging refrigerant gas (R-134a) and filling new compressor oil etc. complete for satisfactory functioning all as specified and directed. Note:Topping up of gas will be measured and paid seperately
S&F hermetic sealed new compressor (in replacement) for water cooler 150 ltr/Hr cooling capacity including disconnecting the electrical and refrigerant connection of defective sealed unit of storage type water cooler of capacity 150 litres and connection of all pipe line & charging of refrigerant and testing complete including taking down existing one all as specified and directed. Make :- As per existing make of Water Cooler Note:- Compressor shall be purchased from manufacturer/ authorised dealer of the manufacturer. Compressor shall be in sealed condition and shall bear warranty for 12 months from the date of purchase.
S&F Electric condensor Fan motor, AC 230 volt, single phase with recommended RPM etc (in replacement) suitable for water cooler of any make of 150/150 litres capacity, all as specified and directed. Make of Fan motor: AUE/ GEC/HIMSUN
S & F Door gasket (in replacement) suitable for lid of water cooler upto 150 litres capacity, all as specified and directed.
Supply and fix Stainless steel tray (in replacement) suitable for water cooler of 150 Litres capacity all as specified and directed.
Taking down corroded bottom portion of water cooler of 150 litres capacity and provision of 14 gauge MS sheet with suitable size angle iron frame work duly welded to the body of the water cooler including two coats of synthetic enamel painting over a coat of red oxide primer to match the existing colour all as specified and directed.
M&L for preparing the old painted surface of the water coolers of capacity cap 150 Litres and spray painting with synthetic enamel paint over one coat of red oxide primer including replacement of worn out nut, bolt, washer, screw and writing MES No and capacity all as specified and directed.
M&L for pressure testing and rectifying the leakages found in the system of water cooler of capacity 60/120 litres and vacuuming and charging refrigerant gas (R-134a) and filling new compressor oil etc. complete for satisfactory functioning all as specified and directed. Note:Topping up of gas will be measured and paid seperately
S&F hermetic sealed new compressor (in replacement) for water cooler 60/120 ltr/Hr cooling capacity including disconnecting the electrical and refrigerant connection of defective sealed unit of storage type water cooler of capacity 60/120 litres and connection of all pipe line & charging of refrigerant and testing complete all as specified and directed. Make :- As per existing make of Water Cooler Note:- Compressor shall be purchased from manufacturer/ authorised dealer of the manufacturer. Compressor shall be in sealed condition and shall bear warranty for 12 months from the date of purchase.
S&F Electric condensor Fan motor, AC 230 volt, single phase with recommended RPM etc (in replacement) suitable for water cooler of any make of 60/120 litres capacity, including taking down existing one all as specified and directed. Make of Fan motor: AUE/ GEC/HIMSUN
Candle (filter) 10” size incl taking down old unsv all as specified and directed
S&F Self closing push type Bib tap 15mm dia made out of cast copper alloy chromium plated (in replacement) suitable for water cooler conforming to ISI mark, including testing and leak proof etc.complete all as specified and directed.
Supply and fix in repair PVC connection pipe 450mm long 15 mm dia with brass unions with washers on both the ends all as specified and directed.
S&F ball brass valve high pressure 15mm dia complete fitting such as PVC polythene ball, layer check nut washer etc for water cooler of any capacity including taking down existing one all directed.
Supply and fix in replacement of gun metal gate valve 15mm dia including GI nipple including taking down existing one all as specified and as directed
S&F PVC drain out pipe 30mm dia bore (in replacement) as per existing including providing necessary GI clamps, nut bolt etc.all as specified and directed
Supply and charging of refrigerant gas R-134a to water cooler, refrigerator and deep freezer air conditioner of any type, make and capacity all as specified and directed
M&L for pressure testing and rectifying the leakages found in the system of water cooler of capacity 40/ 80 litres and vacuuming and charging refrigerant gas (R-134a) and filling new compressor oil etc. complete for satisfactory functioning all as specified and directed. Note:Topping up of gas will be measured and paid seperately
S&F hermetic sealed new compressor (in replacement) for water cooler 40/80 ltr/Hr cooling capacity including disconnecting the electrical and refrigerant connection of defective sealed unit of storage type water cooler of capacity 40/80 litres and connection of all pipe line & charging of refrigerant and testing complete all as specified and directed. Make :- As per existing make of Water Cooler Note:- Compressor shall be purchased from manufacturer/ authorised dealer of the manufacturer. Compressor shall be in sealed condition and shall bear warranty for 12 months from the date of purchase.
M&L for repairing the leakage in the steel water tank of water cooler of any capacity by welding brazing/ soldering complete all as specified and directed.
Taking down corroded bottom portion of water cooler of 40/80 litres capacity and provision of 14 gauge MS sheet with suitable size angle iron frame work duly welded to the body of the water cooler including two coats of synthetic enamel painting over a coat of red oxide primer to match the existing colour all as specified and directed.
Supply and fix Stainless steel tray (in replacement) suitable for water cooler of 40/ 80 litres capacity all as specified and directed.
S&F Evaporator coil suitable for water cooler of capacity 40/80 ltr/hr cooling capacity (in replacement) complete all as specified directed.
S&F Electric condensor Fan motor, AC 230 volt, single phase with recommended RPM etc (in replacement) suitable for water cooler of any make of 40/80 litres capacity, all as specified and directed. Make of Fan motor: AUE/ GEC/HIMSUN
S&F Condensing coil suitable for water cooler of capacity 40/80 ltr/hr cooling capacity (in replacement) complete all as specified directed.
Multi capacitors 45 µfd for cooling appliances including taking down existing unserviceable one complete all as specified and as directed. Make :KELTRON/SRIRAM/EPCOS/BHEL
Multi capacitors 6 µfd for cooling appliances including taking down existing unserviceable one complete all as specified and as directed. Make :KELTRON/SRIRAM/EPCOS/BHEL
M&L for preparing the old painted surface of the water coolers of capacity up to 40/80 Litres and spray painting with synthetic enamel paint over one coat of red oxide primer including replacement of worn out nut, bolt, washer, screw and writing MES No and capacity all as specified and directed.
Supply and fix in replacement of filter for water cooler of any size any make all as specified and as directed
Carbon (filter) 12” size incl taking down old unsv all as specified and directed
Routine repair and annual maintenance of Aqua guards installed in various locations including attending breakdown calls, monthly routine maintenance including replacement of carbon , micron filter as and when required and changing of defective spares, quarterly cleaning of Aqua Guard internally and externally, changing of filters as directed by Engineer-in-charge, for the any models / types, for 11 month period of each aqua guard
PCB Card 12 Volt of DC capacity for Aquaguard incl dismantling old unsv and including taking down existing one complete all as specified and directed and as directed
Routine repair and annual maintenance of best water doctor of tank capacity 25/ 44 ltrs installed in various locations including attending breakdown calls, monthly routine maintenance including replacement of carbon , micron filter as and when required and changing of defective spares, quarterly cleaning of Aqua Guard internally and externally, changing of filters as directed by Engineer-in-charge, Make :- Best water doctor model No. HIMA-5NC of flow rate 100 ltr/ hr.
Routine repair and annual maintenance of best water doctor of tank capacity 40/ 80 ltr installed in various locations including attending breakdown calls, monthly routine maintenance including replacement of carbon , micron filter as and when required and changing of defective spares, quarterly cleaning of Aqua Guard internally and externally, changing of filters as directed by Engineer-in-charge, Make :- Best water doctor model No. UV 7 NC of flow rate 200 ltr/ hr.
Note for item No 234 & 235 :- (a) The contractor shall make AMC contract with the authorised service agency of best water cooler and repair/ maint shall be carried out through the authorised person of OEM only. (b) The rate quoted shall deem to be included for carried out all repairs to water cooler noticed during the period 11 months.
Multi capacitors 36 µfd for cooling appliances including taking down existing unserviceable one complete all as specified and as directed. Make :KELTRON/SRIRAM/EPCOS/BHEL
Multi capacitors 50+2 µfd for cooling appliances including taking down existing unserviceable one complete all as specified and as directed. Make :KELTRON/SRIRAM/EPCOS/BHEL
Excavation in trenches exe 1.5m depth and n exc 1.5 mtr in wide in hard/dense soil and getting out.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in hard and dense soil
Removing of excavated material exc 1.5 KM but n exc 5 KM and depositing where directed at a level n exc 1.5m above the starting point.
Riddling Sand obtained from excavation for cable protection 8cm under the cable and 15cm above the cable in trench and get the thick layer of 18cm after ramming. Note :- In case sufficient sand not obtained from excavation, the required additional qty obtain from out side land as directed by the Engineer-in-Charge. The rate is deemed to be included.
Fly ash cover for cable protection.
XLPE insulated, screened, PVC Bedded, galvanised steel strip or wire armoured, electric power cable heavy duty with aluminium condutor 1100Volts grade cross sectional area 50 Sqmm 3.5 core laid in trenches /ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets, taking down existing cable etc all as specified and directed. Note : Excavation and earth work shall be measured and paid seperately. Make : KEI/ Polycab/ Havells
XLPE insulated,screened ,PVC Bedded, galvanised steel strip or wire armoured, electric power cable heavy duty with aluminium condutor 1100Volts grade cross sectional area 35 Sqmm 3.5 core laid in trenches /ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets, taking down existing cable etc all as specified and directed. Note : Excavation and earth work shall be measured and paid seperately. Make : KEI/ Polycab/ Havells
Cutting existing road/PCC/Drain for laying of DI/GI or any type of pipe including necessary earth work, excavation exc 600mm depth but not exc 1mtr depth, wide 800mm including making existing surface with PCC 1:2:4 type B1 using 20mm aggregate thickness of concrete is 150mm complete all as specified and directed.
Note for item No 246 :- The tenderer shall take into consideration for following points while quoting his rate for this item and the unite rate is deemed be included for :-
(i) Earth work excavation in any type of soil
(ii) Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick complete all as specified and as directed.
(iii) Removing excavated material to out side MD land
(iv) Laying of any type/any bore of pipe in trenches including taking down any description. Supply of pipe will be measured and paid separately
(v) 150 mm thick PCC 1:2:4 type B1 as in road
Supply only GI pipe 50 mm bore medium grade for cable protection complete all as specified and as dierced by Engr-in-Charge. Make : Tata, Jindal, Surya Prakash Note : The unit rate is included for supply only and cutting existing road , excavation, Laying of any type/any bore of pipe in trenches including taking down any description and 150 mm thick PCC 1:2:4 type B1 as in road will be measured and paid separately.
Cable jointing kit for 1.1 KV grade cable for outdoor stright through heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armored aluminium conductor cable of size 35 sqmm to 50 sqmm. Make : Reychems, Densons, M-seal
S&F in replacement MCCB four pole, 400 Amp ultimate breaking capacity 36 KA, 415V including connecting by using suitable size of lugs complete conforming to IEC -61439-1 complete all as specified. Make : L & T/ Legrand/ Siemens
S&F in replacement MCCB four pole, 250 Amp ultimate breaking capacity 36 KA, 415V including connecting by using suitable size of lugs complete conforming to IEC -61439-1 complete all as specified. Make : L & T/ Havells/ ABB
Supply, installation, commissioning and testing of Factory assembled, Floor mounted, free standing, type tested LT Feeder Pillar Panels, with canopy, as per electrical specifications for outdoor installation, to be made of IP65 Polycarbonate modular enclosures. The Enclosures made of Polycarbonate, should be weather/ vermin proof, anti-acid, anti-corrosive, UV resistance in accordance with IEC 61439-1, Fire retardant and Self-extinguishing in accordance with IEC 60695-2-11, UL subject 94 for flammability V-0, should pass glow wire test for 960° in accordance with 60695-2-11. Degree of protection against mechanical load should be IK 08 (5 Joule) in accordance with IEC 62262, IP 65 in accordance with IEC 60529 & IEC60439-1, should have Dielectric Properties, RoHS compliant & Halogen free. The manufacturer of boards/panel shall submit a copy of type test reports as per above-mentioned norms either from UL/ERDA/CPRI/NABL labs in India. The panels should be modular and compartmentalized in construction with opaque and transparent doors, properly tightened to base with thermoplastic screws having sealing gaskets of extruded silicon rubber to withstand adverse weather effects. The depth of modular enclosures should be above 200mm for air circulation & to minimize temp rise. Panel should be fitted with 01 No polycarbonate IP 65, 9W LED translucent bulk head luminaire, 6500K, PF > 0.95 under canopy for easy maintenance. Panel should be fitted outside with 01 No of 16A 3P IP 65 industrial socket and 01 No of 32A 5P IP 65 industrial socket. 3 phase and neutral 400 amps current carrying capacity copper bus bar insulated with colour coded heat shinkable sleeves with SMC/DMC insulators, complete with the following switch gears and mounting the panel board on ground with PCC (1:3:6) bedding upto a height of 45 cm above ground level, including dismantling and taking out old u/s LT Panel Board and remove from site reconnecting existing LT Cables with new panel board complete all as directed :-
XLPE insulated,screened ,PVC Bedded, galvanised steel strip or wire armoured, electric power cable heavy duty with aluminium condutor 1100Volts grade cross sectional area 25 Sqmm 4 core laid in trenches /ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets, taking down existing cable etc all as specified and directed. Note : Excavation and earth work shall be measured and paid seperately. Make : KEI/ Polycab/ Havells
XLPE insulated,screened ,PVC Bedded, galvanised steel strip or wire armoured, electric power cable heavy duty with aluminium condutor 1100Volts grade cross sectional area 16 Sqmm 4 core laid in trenches /ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets, taking down existing cable etc all as specified and directed. Note : Excavation and earth work shall be measured and paid seperately. Make : KEI/ Polycab/ Havells
Cable jointing kit for 1.1 KV grade cable for outdoor stright through heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armored aluminium conductor cable of size 16 sqmm to 25 sqmm Make : Reychems, Densons, M-Seal
Supply only 50 mm bore of pipe high density polyethylene pipes (HDPE) of pressure rating 6 kgf/ cm2 laid in trenches for cable protection passing under road/ floor or for fixing to poles complete all as specified and directed. Note : The unit rate is included for supply only and cutting existing road , excavation, Laying of any type/any bore of pipe in trenches including taking down any description and 150 mm thick PCC 1:2:4 type B1 as in road will be measured and paid separately.
S&F in replacement on distribution board MCCB four pole, 125 Amp ultimate breaking capacity 25 KA, 415V including connecting by using suitable size of lugs complete conforming to IEC -61439-1 complete all as specified. Make : L & T/ Siemens/ ABB
S&F in replacement on distribution board MCCB three pole, 63 Amp ultimate breaking capacity 16 KA, 415V including connecting by using suitable size of lugs complete conforming to IEC -61439-1 complete all as specified. Make : L & T/ Siemens/ Legrand
Supply and fix Double pole MCB 32 Amp, 240 V, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity complete conforming to IS 8828 of 1996 all as specified (Make/Model : Siemens/ ABB/ Legrand.
PVC tape roll self adhesive of size 1.90cm x 0.125mm x 25m. Make- Steelgrip, Kinjal, Anchor.
M&L for Sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 4 sqmm drawn through in and incl suitable size PVC conduit and all accessories fixed to wall/floors along with 4 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size.
Note for item No 267: (a) 2 runs of 4 sqmm cable along with one run of 4 sqmm cable for earth conductor shall be measured as one length. (b) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles. Make:- Havells/ Polycab/ Plaza.
M&L Earthing with Galvanised Earth Plate Electrode 600x600x 6mm thick burried directly in Ground (Earth Pit not less than 2.25 Metre below Ground Level) with Top edge of the Plate not less than 1.50 Metre below Ground Level, connected with Galvanised Earth Strip of size 25 x 6mm by means of Bolts, Nuts, Check Nuts and Washers of GI or Steel and connected Earthing Testing Point/Bus-bar including GI 40mm bore (dia) light grade Protection Pipe, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt, magnesium sulphate (1 : 1 : 0.5) in alternate layers of not exc 150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded stone aggregate) and Pre-cast RCC Cover Slab of size 350x350x50 mm in Cement Concrete 1:2:4 (20mm graded stone aggregate), reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, Funnel with GI Watering Pipe 20mm bore (dia) medium grade including necessary Excavation in Soft/Loose Soil, Returning, Filling in and Removal of surplus Spoil upto a distance of 50.00 Metre and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on Completion including taking down old unserviceable one, complete all as per specified and as directed.
Note for item No 269 :- (a) All Joints should be joined by Exothermic Welding or Brazing.
(b) After completion of work earthing shall be tested by the contractor in presence of Engineer-in-Charge, User and proper record shall be maintained duly signed by all concerned.
(c) Earth resistance tester should be calibrated from authorised company/ lab.
(d) After testing if desired earth resistance of less than 5 Ohm is not obtained, the earthing will be redone at no extra cost to Govt till desired result is obtained.
Comprehensive Repair & servicing of 2 KVA to 7.5KVA on line UPS of Make BEC with battery with distilled water, attending day to day complaints as directed by the Engineer -in-charge. Note:-(a) The contractor shall make AMC contract with the original manufacturer of UPS and the repairs/maintenance shall be carried out through the original manufacturers only Location - 28 runway end, Navy hangar, HRDF hut. (b) Cost of any minor items to be replaced is included in the item rate quoted.
Comprehensive Repair & servicing of 5 KVA single phase on line UPS of Make Aplab with battery ,attending day to day complaints as directed by the Engineer -in-charge. Note:-(a) The contractor shall make AMC contract with the original manufacturer of UPS and the repairs/maintenance shall be carried out through the original manufacturers only Location - New TRCL Bldg (06 Nos), Old TRCL Bldg-04 Nos, New ATC (RT Cabin/ Met Section) - 04 Nos, Transmitter - 01 No. (b) Cost of any minor items to be replaced is included in the item rate quoted.
Comprehensive Repair & servicing of 10 KVA three phase on line UPS of Make BEC with battery ,attending day to day complaints as directed by the Engineer -in-charge, once in 03 months. Note:-(a) The contractor shall make AMC contract with the original manufacturer of UPS and the repairs/maintenance shall be carried out through the original manufacturers only Location - Tarang Lab. (b) Cost of any minor items to be replaced is included in the item rate quoted.
Comprehensive maintenance of 25KVA true online UPS system with SMF batteries, with input supply of 3 phase 415V,50HZ of Make Aplab including attending day to day complaints , isolating UPS from system, Opening up, examining the accessories parts, cleaning, soldering as required and testing and connecting back with the system. as directed by the Engineer -in-charge. Note:-(a) The contractor shall make AMC contract with the original manufacturer of equipment and the repairs/maintenance shall be carriedout through the original manufacturers only. Location CRRW. (b) Cost of any minor items to be replaced is included in the item rate quoted.
Comprehensive maintenance of 40KVA true online UPS system with SMF batteries, with input supply of 3 phase 415V,50HZ of Make Aplab including attending day to day complaints , isolating UPS from system,Opening up,examining the accessories parts,cleaning,soldering as required and testing and connecting back with the system. as directed by the Engineer -in-charge. Note:-(a) The contractor shall make AMC contract with the original manufacturer of the equipment and the repairs/maintenance shall be carriedout through the original manufacturers only. Location generator set room. (b) Cost of any minor items to be replaced is included in the item rate quoted.
Note For item No 274 to 278 :- Payment shall be made thrice for the period of 11 months proportionately, for comprehensive maintenance.
Supply only Cooling fan suitable for 5 to 25KVA true online UPS and including taking down existing one of Make - Aplab all as specified and directed.
Supply only DC Capacitor suitable for 5 to 50KVA true online UPS including taking down existing unserviceable one of all as specified and directed. Make - Aplab
Supply only IGBT suitable for 5-25KVA true online UPS and including taking down existing one all as specified and directed of Make - Aplab
Supply only IGBT suitable for 40-50KVA true online UPS of Make - Aplab
Supply and Fix Sealed Maintenance Free (SMF) battery of capacity 12 V, 26 AH, suitable for existing 3 phase online UPS as required at location including initial charging complete with inbuilt charger including electrolyte/ distilled water etc including taking down of old battery and shifting to MES store yard for deposit all as directed by engineer in charge complete all as specified. Make of battery : Exide of model No. EP 65 or equivalent in Amar raja (Power Zone)/ Amaron Note :- (i) The contractor shall submit full replacement warranty certificate for minimum 02 years from the date of installation. (ii) The contractor shall supply SMF battery as per requirement given by Engineer-in-Chare throughout the currency of contract.
Comprehensive maintenance of 20KVA static frequency converter with input supply of 3 phase 415V,50HZ with output of 115 V,400HZ. of Make Aplab including attending day to day complaints , isolating converter from system, Opening up, examining the accessories parts,cleaning,soldering as required and testing and connecting back with the system. as directed by the Engineer -in-charge. Note:-(a) The contractor shall make AMC contract with the original manufacturer of servo stabilizer and the repairs/maintenance shall be carried out through the original manufacturers only. Location CRRW. (b) Cost of any minor items to be replaced is included in the item rate quoted.
Comprehensive maintenance of DC power supply (Rectifier)28 Volts DC Output,15 KW with input supply of 3 phase 415V,50HZ . of Make Aplab including attending day to day complaints , isolating converter from system,Opening up,examining the accessories parts,cleaning,soldering as required and testing and connecting back with the system. as directed by the Engineer -in-charge. Note:-(a) The contractor shall make AMC contract with the original manufacturer of the equipment and the repairs/maintenance shall be carriedout through the original manufacturers only. Location Generator Room,Instrument Rotable section. (b) Cost of any minor items to be replaced is included in the item rate quoted.
Note For item No 285 & 286 :- Payment shall be made thrice for the period of 11 months proportionately, for comprehensive maintenance.
Supply only Cooling fan suitable for 20KVA Frequency converter and including taking down existing one of as specified and directed Make - Aplab
Supply only Cooling fan suitable for 15 KW DC power supply of Make - Aplab
Supply only DC Capacitor suitable for 20 to 40KVA Frequency converter including taking down existing unserviceable one of Make - Aplab all as specified and directed.
Supply only IGBT suitable for 20-40 KVA Frequency converter including taking down existing unserviceable one of all as specified and directed Make - Aplab
Supply only IGBT suitable for 15 KW/20KW DC power supply including taking down existing unserviceable one of Make - Aplab all as specified and directed.
Comprehensive maintenance of 3 phase servo stabilizer with input variation between 340V to 400V with output stabilized at 415 Volts of capacity 10 KVA of Make Adroit including attending day to day complaints , isolating stabilizer from system, Opening up, examining the accessories parts,cleaning,soldering as required and testing and connecting back with the system. as directed by the Engineer -in-charge Note:-(a) The contractor shall make AMC contract with the original manufacturer of servo stabilizer and the repairs/maintenance shall be carried out through the original manufacturers only. Location AVRO
Comprehensive maintenance of 3 phase air cooled servo stabilizer with input variation between 340V to 400V with output stabilized at 415 Volts of capacity 15KVA of (Make RDC)including isolating stabilizer from system, Opening up, examining the accessories parts,cleaning,soldering as required and testing and connecting back with the system as directed by the Engineer -in-charge, Note:-(a) The contractor shall make AMC contract with the original manufacturer of servo stabilizer and the repairs/maintenance shall be carried out through the original manufacturers only. Location RT Cabin
Comprehensive maintenance of 3 phase oil cooled servo stabilizer with input variation between 340V to 400V with output stabilized at 415 Volts of capacity 75KVA with all spares including isolating stabilizer from system, Opening up, examining the accessories parts,cleaning,soldering as required and testing and connecting back with the system. periodical maintenance as recommended by the original manufacturer complete all as specified and directed. Location Transmitter plant
Comprehensive maintenance of 3 phase oil cooled servo stabilizer with input variation between 340V to 400V with output stabilized at 415 Volts of capacity 125KVA of Make Power One including isolating stabilizer from system, Opening up, examining the accessories parts,cleaning,soldering as required and testing and connecting back with the system as directed by the Engineer -in-charge Note:-(a) The contractor shall make AMC contract with the original manufacturer of servo stabilizer and the repairs/maintenance shall be carried out through the original manufacturers only. Location SRE bldg
Comprehensive maintenance of 3 phase oil cooled servostabilizer of Make BEC with input variation between 340V to 400V with output stabilized at 415 Volts of capacity 150KVA with all spares including isolating stabilizer from system, Opening up, examining the accessories parts,cleaning,soldering as required and testing and connecting back with the system. periodical maintenance as recommended by the original manufacturer complete all as specified and directed. Location DWR BLDG
Note for Item No 293 to 297 :- (a) In above items, maintenance shall be done through authorised person of OEM. The contractor shall make AMC contract with the original manufacturer of servo stabilizer and the repairs/maintenance shall be carried out through the original manufacturers only. (b) The rate quoted shall be deemed to include for carried out all repairs to servo stabilizer noticed during the period 11 months.
M&L for Servicing of Air curtains unit, of any type capacity and length, single phase AC, 230 Volts as in preventive maintenance alongwith blower assembly filter and other components including checking electrical connections all as specified and as directed.
M&L for blower motor assembly of Air curtain unit of any type capacity and length, single phase AC, 230 Volts as including electrical connections all as specified and as directed.
Periodical servicing, calibaration and maintenance of composite synchronous panel of Make Jackson PCC 3.3 based auto load management, auto load sharing, auto synchronization panel suitable for 3 x 810 KVA stand by DG set comprising of following components :-
(a) INCOMER (i) Air circuit breaker 1600A, 415V, 50Hz – 03 Nos (ii) Engine start/ stop push button. (iii) Digital temperature Scanner - 03 Nos (iv) Annunciator– 03 Nos. (v) Electric buzzer (hooter)– 03 Nos (vi) Digital multifunction meter– 03 Nos. (vii) DC voltmeter – 03 Nos (viii) Indicating LED lights for 3 phase R, Y, B, breaker – ON/ OFF, neutral – ON/ OFF, battery charger ON/ OFF etc.
Note :- (i) The unit quoted rate shall deem to be included to carried out all repairs noticed during the period. (ii) Repairs/ maintenance shall be carried out through the authorised service agency only as per instructions recommended by the original manufacturer. (iii) The authorised service agency must be attended as and when called for urgent nature of repair of synchronous panel irrespective of number of visit. (iv) Otherwise, periodicity shall be around 03 months or as per manufacturer instruction. (v) Replacement of minor items shall be included in the unit quoted rate. (vi) Replacement of any major defective items will not be included in the scope of work. However, the decision of Accepting Officer is final and binding in deciding, whether the defective item is major or minor in nature.
SUPER COOL
Neptune Engineers and Builders
PRIYA ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .