| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.7 LAccepted-AOC 2 EVEREST VIHAR PT T N MISHRA MARG NIRMAN NAGAR JAIPUR 302019 | JAIPUR | RAJASTHAN | 302019 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹29.2 L+₹2.5 L (9.53%)Rejected-Finance SHIV BARI ROAD NEAR KASUMAL HOTEL BIKANER 334003 RAJASTHAN | BIKANER | BIKANER | RAJASTHAN | 334003 | L2 | Rejected-Finance Other than Lowest | |
| 3 | L3₹36.0 L+₹9.4 L (35.1%)Rejected-Finance 26 740 35 KESARI HOUSE NEAR RICO INDUSTRIAL AREA DEVIPURA SIKAR RAJASTHAN 332 001 | SIKAR | SIKAR | RAJASTHAN | 332001 | L3 | Rejected-Finance Other than Lowest |
| Sl No | Description | Qty | Unit | Rasam Engg Co. L1 | M/s Rohit Construction Co. L2 | HUMERS INFRATECH L3 |
|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, laying of cable/pipe/pole etc or soil for shaft, walls, cesspts, manholes, pier holes etc not exceeding 10 sqm on plan and getting out soft/disintegrated soil complete all as specified and directed by Engineer -in- Charge. | 190 | CUM | 270 ₹51,300 | 400 ₹76,000 | 150 ₹28,500 Lowest |
| 2.00 | Excavation in trenches n.exc 1.5 m wide and exc 1.5 m depth but not exceeding 3.0 m depth and getting out soft/disintegrated soil, including trimming the sides and forming bottom surface to required levels for laying cables complete all as specified and directed by Engineer -in- Charge. | 1 | CUM | 500 ₹500 | 1,000 ₹1,000 | 165 ₹165 Lowest |
| 3.00 | Returning, filling in, including, spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick soft/disintegrated soil complete all as specified and directed by Engineer -in- Charge. | 165 | CUM | 60 ₹9,900 | 30 ₹4,950 Lowest | 120 ₹19,800 |
| 4.00 | Removing excavated material (soil) to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed by Engineer -in- Charge. | 25 | CUM | 60 ₹1,500 | 30 ₹750 Lowest | 100 ₹2,500 |
| 5.00 | Supply, Installation, Testing & Commissioing of HT 11 KV, 3 phase 50 Hz, indoor type, totally enclosed metal clad switchgear complete with Vacuum Circuit Breaker (VCB) having rating 800 Amps and rupturing capacity 350 MVA, including overload and earth fault Protection,ammeter, voltmeter etc complete all as specified and directed by Engineer -in- Charge.
Note :- Proposed VCB will be connect the existing VCB BUS
Make of Existing VCB : Crompton Greaves Ltd
IS : 3427-1997/IEC62271-200 | 2 | EACH | 6,85,000 ₹13,70,000 Lowest | 7,50,000 ₹15,00,000 | 9,50,000 ₹19,00,000 |
| 6.00 | Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminium conductor, 11000 volts grade, of size 95 sq mm 3 core complete all as specified and directed by Engineer -in- Charge.
Note :- Earthwork, excavation & protection pipe shall be measured and paid separately under relevant items. | 380 | RM | 900 ₹3,42,000 Lowest | 1,000 ₹3,80,000 | 1,150 ₹4,37,000 |
| 7.00 | All as per item No. 6.00 here-in-before above but size of cable 120 sq mm 3 Core. | 200 | RM | 1,100 ₹2,20,000 Lowest | 1,200 ₹2,40,000 | 1,250 ₹2,50,000 |
| 8.00 | S&F Air break switch gang operated HT 11 KV Volt grade triple pole with 12 insulators, 400 amps rating with drop out fuse assembly with fuse carrier, fuse element mounted on insulator and fitted on steel frame vertical type operated mechanism from ground level consisting of operating rod of 25mm bore medium grade GI pipe ISI marked of suitable length worked from ground level and with locking arrangement flat iron clamp 50mm x 6mm including MS channel of suitable size and length for fixing GOD including bolts, nuts, and washers complete all as specified and directed by Engineer -in- Charge.
Note :- Channel, cross arms, bracings etc shall be measured and paid separately under relevant items. | 4 | EACH | 15,000 ₹60,000 Lowest | 18,000 ₹72,000 | 23,500 ₹94,000 |
| 9.00 | Supply and install, testing and commissioning of lighting arrestor (Static type) out door Non-Linear resistor type line discharge class-2 nominal discharge current 10 kA and high current with starnd 100 kA assembly suitable for 11 KV including all clamps, nuts, bolts and washers and connection to earth strip with 32 x 6 mm complete all as specified and directed by Engineer -in- Charge. | 2 | SET OF THREE | 3,500 ₹7,000 Lowest | 3,500 ₹7,000 Lowest | 16,000 ₹32,000 |
| 10.00 | M&L for steel tubular swaged poles and complete with cast iron / M.S base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-55 (11 mtrs long) including painting with two coats of aluminium paint over a coat of red oxide metal primer. The pole shall conform to IS 2713:1980 and each component pipe shall be ISI marked and conform to IS -1161 complete all as specified and directed by Engineer -in- Charge. Note :- For 2 nos four pole structure | 8 | EACH | 24,000 ₹1,92,000 Lowest | 28,000 ₹2,24,000 | 28,000 ₹2,24,000 |
Tender Value
₹40.9 L
EMD Value
₹82,000
Closing Date
14 Oct 2025, 6:00 pmClosed
CWE (A) Jaisalmer
HQ CWE ARMY JAISALMER 345001 RAJASTHAN
PROVN OF 11 KV VCB AND ALLIED WORKS FOR 33/11 KV MRS STATION HQ UNDER GE (A) JAISLAMER.
2025_MES_731130_1
84357/C/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
JAISALMER
AS PER NIT
8 documents required · 8 mandatory
₹500
GE ARMY JAISALMER
₹82,000
Yes
31 Oct 2025
16 Sept 2025
16 Oct 2025
16 Sept 2025
14 Oct 2025
1 Oct 2025
16 Sept 2025 - 22 Sept 2025
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .