Tender Value
Refer Docs
EMD Value
₹3.2 L
Closing Date
28 Jul 2026, 2:00 pmClosed
Executive Engineer STD Udhampur
Executive Engineer STD Udhampur
Revamping/Renovation of Various R/Stns in respect of STD Udhampur (Elect Works) Scheme Code PDDSS2627100642)
2026_PDD_315098_1
12-A of 2026-27
Open Tender
Electrical Works
Item Rate
120 days
Udhampur
Please refer Tender documents.
4 documents required · 4 mandatory
₹5,000
Executive Engineer STD Udhampur
₹3.2 L
29 Jul 2026
8 Jul 2026
29 Jul 2026
8 Jul 2026
28 Jul 2026
8 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Survey, Supply, Installation , Testing and Commissioning for revamping/stablisation of various 33/11 KV Receiving Stations by replacement of wornout/damaged equipment by new one under the jurisdiction of Sub Division Katra | - | - | - | - |
| 2 | 33 kV Vacuum Circuit Breaker (36 kV, 1250A, 26.2 kA, Outdoor Type) SCADA compatible Make Megawin, BHEL,ABB,Pascal or Stelmac | 1 | nos | - | - |
| 3 | 33kv Isolator without Earthing Blade (36kv , 1250A,outdoor,3 poles, 25KA ). | 1 | set | - | - |
| 4 | 30 kv Lightening arrestors (30kv,10KA, Polymer, station class, ZnO)gap less | 1 | set | - | - |
| 5 | 33 kV C&R Panel along with O/C, E/F and differential relays (IEC61850), mimic diagram, Voltmeter, Ammeter, Annunciation Windows with annunciation relays, 3-phase Tri-vector meter -5 Amps, DLMS Compliant with RS-485 port SCADA Compatible.Make Make Megawin, BHEL,ABB,Pascal or Stelmac | 1 | nos | - | - |
| 6 | 33 KV Current transformer(33kv 1 phase, multi ratio ,multicore, outdoor)1 no per phase 400/200/5 | 3 | nos | - | - |
| 7 | CONTROL CABLES : i) 6 Core 2.5mm2 multistrand control cable copper armoured, 1.1KV Grade ISI,FRLS of make Havells, Polycab,etc. | 80 | mtr | - | - |
| 8 | ii) 2 Core 2.5mm2 multistrand control cable copper armoured, 1.1KV Grade ISI,FRLS of make Havells, Polycab,etc. | 80 | mtr | - | - |
| 9 | Supply, Errection, Testing & commisioning of Float-Cum-boost Charger with full wave rectification for 220v, 1 Phase 50HZ AC input supply suitable for charging of Battery Bank 32V, 100AH of 15+1 No. cells of 2V each, sealed maintenance free VRLA type, Hgh Impact Polyprophelene copolymer container flame retardant | 1 | no | - | - |
| 10 | 11 kV VCB Panel Board Set (12 kV, 1250A, 25 kA, Indoor) with O/C, E/F relays (IEC61850), Mimic Diagram, Voltmeter, Ammeter, Annunciation Windows with annunciation relays, 3-phase Tri-vector meter -5 Amps, DLMS Compliant with RS-485 port SCADA Compatible etc MAKE :- Seimens, Megawin, Pascal, or Stelmac :- For 10 MVA Power Transformer (1+5) including Smart meters Trivector. | 1 | set( 1 incomer +5 outgoing) | - | - |
stage.html
html • 0.02 MB
tech_bid_open.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.17 MB
BOQ_1021092.xls
BOQ • 0.29 MB
SBDElectWorks.pdf
Tender Documents • 7.41 MB
Checklist.pdf
Other Document • 0.12 MB
CorrigendumPaymentandcompletion.pdf
PDF • 0.21 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .