Electrical Works for (i)At NLP: Provision of Goods office, shed, High mast tower, drainage system, labour and merchant room, drinking water, water sprinkling system, bathroom, circulating area and approach road. (ii)At SPTR: Provision of Goods office, shed, labour and merchant room, Water sprinkling system, bathroom and drinking water facility.
LV-T-14-TSK-936~NFR
LV-T-14-TSK-936
Open
Works - General
12 Months
Tinsukia, Assam
₹0
₹87,300
4 Mar 2026
9 Feb 2026
18 Feb 2026
A-At NLP: Provision of Goods office, shed, High mast tower, drainage
Supply, fitting, fixing, testing & commissioning of wiring materials for concealed type 001 wiring of light point from main/sub-main board to the points by 1.5 mm.sq.single core multi-strand FRLS copper cable through heavy duty PVC pipe complete with modular type switch 6 A, ceiling rose, GI box with suitable modules for fixing switches.
Supply, fitting, fixing, testing & commissioning of wiring materials for concealed type 002 wiring of Fan Point/Exhaust fan point from main/sub-main board to the points by 1.5 mm.sq.single core multi-strand FRLS copper cable through heavy duty PVC pipe complete with modular type switch 6 A,ceiling rose,Modular GI metal box with suitable modules for fixing switches & Regulators and 1.0 sq mm multistrand FRLS copper Cable in green for earth contuinity wire .
Supply, fitting, fixing, testing & commissioning of Electronic fan Regulator 100 W .
Supply, fitting, fixing, testing & commisioning of wiring materials for concealed type 004 wiring 5 A plug point from main/sub-main board to the points by 1.5 mm. sq. single core multi-strand FRLS copper cable through heavy duty PVC pipe complete with modular type switch & socket 5 A,GI metal box with Suitable modules for fixing switch/socket with 1.0 mm² unsheathed FRLS copper cable in green colour for earth continuity wire.
Supply, fitting, fixing, testing & commisioning of wiring materials for concealed type wiring 15 A plug point from main/sub-main board to the points by 4 mm. sq. single core multi-strand FRLS copper cable through heavy duty PVC pipe complete with modular type switch & socket 15 A , GI metal box with Suitable modules for fixing switch/socket with 1.0 mm² unsheathed FRLS copper cable in green colour for earth continuity wire.
Supply, fitting , fixing of surface mounted LED Batten 20W, 4 Ft, ultra slim co- extruded polycarbonate channel with integrated electronic driver should be as per IEC: 006 62384/IS:16104( SMPS based constant current output, THD<20%), IP20 protection, color temperature=6500K, rated input voltage=230V AC, 50 Hz, power factor=0.9, view angle>=120°, lumens output not less than 100 lm/Watt, operating voltage range: 140-270 V AC. LED Should be as per LM-80/IS:16105. Fixture Size:(LXWxH=1156x25x35 mm +/-1) . The fitting should be warranted for 5 Years.
Supply and fitting , fixing of 18 Watt LED ,Slim, compact, auminum die cast edge lit panel light , recess mounted square fixture with opal diffuser and separate electronic driver. Ceiling Cut Out (210x210 mm).
Supply, fitting, fixing of exhaust fan 300 mm sweep,230V AC,50Hz metallic louver type
Supply, drawing and connection of single core 6 sq. mm PVC insulated & unsheathed multistrand FRLSH copper cable conforming to IS: 694 for voltage grade upto 1100 Volts , as per direction of supervisor incharge at site.
Supply, drawing and connection of single core 4 sq. mm PVC insulated & unsheathed multistrand FRLSH copper cable conforming to IS: 694 for voltage grade upto 1100 Volts , as per direction of supervisor incharge at site.
Supply, drawing and connection of single core 2.5 sq. mm PVC insulated & unsheathed multistrand FRLSH copper cable conforming to IS: 694 for voltage grade upto 1100 Volts , as per direction of supervisor incharge at site.
Supply, fitting, fixing, testing & commissioning of wall mounted type 6 way double door SPN MCB DB having IP 43 protection,Shrouded Neutral Bar & Bus Bar, Cement Spill Protector & 012 Door Earthing with the following domestic switchgears:- :- i) 240/415V, 50Hz, 10kA BC "C" series SP 32 Amps. MCB (In accordance with IS/IEC 60898-1) = 2 No. ii) 240V, 50Hz, with 10kA BC "C" series SP 16 Amps. MCB (In accordance with IS/IEC 60898-1) = 2 Nos. (iii) 240V, 50Hz, with 10kA BC "C" series SP 10 Amps. MCB (In accordance with IS/IEC 60898-1) = 2 Nos.
Supply, installation, testing and commissioning of VTPN Distribution Board System 013 type 4 way double door, IP 43 Protection with MCCB as incomer with the following switchgears: (i) MCCB, 4 pole, 100 Amps, 16 KA BC= 1 No (ii) MCB , SP, 63 Amps, 'C' series=4 Nos. (iii) MCB, SP, 32 Amps, 'C' series=3 Nos
Earthing by 50 mm dia, 3.6 mm thickness 3 Mtrs long GI pipe and 6 SWG GI wire,GI 014 nuts,bolts including masonary materials for earthing pit,salt,charcoal etc. and construction of earth pit covered with CI plate having locking arrangement and watering pipe as per Drawing No PCEE/ELG/DRG/2024/1 Dtd 30.09.2024
Supply, laying , connection , testing and commissioning of LT XLPE Insulated, Cores Laid Up, PVC Inner sheathed, Armoured stranded aluminum conductor cable size 95 mm.sq. 4 core having Galvanized steel Strip, Extruded PVC Type ST2 Sheathed, 650/1100V Grade As Per IS 015 7098(Part 1) 1988.For laying of above cable digging of trench and excavation of earth/concrete to depth 0.75 Mtrs. and breadth 0.5 Mtrs. below the ground level and a layer of sand of 0.075 Mtrs. thickness shall be spread over the ground before laying the cable and the cable shall be covered with a layer of sand of 0.075 Mtrs. thickness. The bottom of cable trench shall be leveled and got rid of any sharp material. The cable route markers should be provided along the route of cables to indicate their presence so that damage/accident are Not caused by inadvertent digging. .
Supply, laying, connection, testing and commissioning of LT XLPE Insulated, Cores 016 Laid Up, PVC Inner sheathed, Armoured stranded aluminum conductor cable size 25 mm.sq. 4 core having Galvanized steel Strip, Extruded PVC Type ST2 Sheathed, 650/1100V Grade As Per IS 7098(Part 1) 1988. For laying of above cable digging of trench and excavation of earth/concrete to depth 0.75 Mtrs. and breadth 0.5 Mtrs. below the ground level and a layer of sand of 0.075 Mtrs. thickness shall be spread over the ground before laying the cable and the cable shall be covered with a layer of sand of 0.075 Mtrs. thickness. The bottom of cable trench shall be leveled and got rid of any sharp material. The cable route markers should be provided along the route of cables to indicate their presence so that damage/accident are Not caused by inadvertent digging. (For HM Towers)
Supply, laying,connection, testing and commissioning of cable size 16 mm.sq. 2 core ,LT XLPE Insulated, Cores Laid Up, PVC Inner sheathed, Armoured cable having Aluminium Strip, Glavanised Wire Solid Aluminum Conductor, Extruded PVC Type ST2 Sheathed, 650/1100V Grade As 017 Per IS 7098(Part 1) 1988. For laying of above cable digging of trench and excavation of earth/concrete to depth 0.75 Mtrs. and breadth 0.5 Mtrs. below the ground level and a layer of sand of 0.075 Mtrs. thickness shall be spread over the ground before laying the cable and the cable shall be covered with a layer of sand of 0.075 Mtrs. thickness. The bottom of cable trench shall be leveled and got rid of any sharp material. The cable route markers should be provided along the route of cables to indicate their presence so that damage/accident are Not caused by inadvertent digging.
a) Supply and erection of single arm type Hot Dip Galvanized in single deep to average 65 micron DFT 7 mtr. long octagonal pole similar to NEZONE cat. No. NZOP7 with sectional dia 130x70 mm, overall sectional thickness 3 mm complete with base plate size 220x220x12 mm, 4 Nos. 700 mm long foundation bolt of 20 mm dia with all other accessories as per direction of Engineer in charge at site. b) Supply and erection of PCC/RCC/shallow foundation of size and depth 018 as per recommendation and drawing of the manufacturer (approx. 1.6 mtr.x 0.6 mtr.x0.6 mtr.) with excavation of earth for foundation of all depth and all places, nature and condition of soil including de-watering, shoring, shuttering, batching, mixing, placing, leveling, carrying etc and re-filling the pit after completion of foundation work from excavated earth or borrowed pit by contractor's own arrangement for octagonal poles. Drawing of foundation details, loading, sectional plan bar bonding schedule etc. should be submitted before execution to get the approval from Rly. competent authority. c) Supply and erection of suitable size galvanized single arm bracket 1.5 mtr. long along with spigot for holding/supporting one no. street light fitting.
Supply and installation of Desert cooler 55 Ltrs tank capacity having coverage area of 1200 sq feet and air delivery rate of 12000 meter cube per hour with cooling pads of honeycomb 019 type and fan size 16 inch with motor capacity of 650watt(having copper windings) and speed of 2600rpm with air throw distance of 100 feet with features of inverter compatibility,ice chamber,auto fill and drain,castor wheel,auto louver movement with thermal overhead protection,water level indicator having body of high grade,rust-resistant plastic for durability and lightweight design
Supply, installation testing and commissioning of Energy Efficient Ceiling Fan 1400 020 mm sweep BLDC motor, BEE 5 star rated ceiling fan With regulator enable motor with power of 28 watt with 10% tolerance , motor insulation B type 220-240V 50Hz single phase with Speed minimum 350 rpm minimum air delivery 225CMM complete set of 3 no's. blade , down rods, 2 nos canopies , shackle kit & all remaining accessories including nut bolts Washers complete as required .
Supply, fitting, fixing of LED Street Light 45 W to be fixed on octagonal pole. Specification of 45 W Street light : Housing: Pressure die-cast aluminium alloy for housing (heat sink) for effective thermal management, sturdiness & excellent corrosion resistance. Cable gland is used for maintaining ingress protection, Finish: Epoxy powder coated siemens grey after 021 phosphochromate treatment,Light source :High efficiency long life LED chip in modules with lumen efficacy of 140 lm/W with PC lens to ensure better uniformity of light distribution. Cover: Tempered protective toughened glass, thermal, shock and impact-resistant, fixed to the housing with SS screws. Electronic Driver: Built-in potted electronic LED driver with APFC (SMPS based constant current supply), lower THD, Open Circuit protection, Phase to Phase protection, Over Voltage protection, Surge Voltage protection & other safety tests as per IS 15885 Part-2/Sec 13.
"Supply, installation, testing and commissioning of Water cooler storage capacity 80 Ltrs, cooling capacity : 60ltrs/hr with RO commercial water purifier. Specification of water cooler: (i) Dimension: Width: 640 mm, Depth: 450 mm Height:1350 mm (ii) Weight without water: 85Kg (iii)Maximum Current(Amps)=5Amps (iv) Cooling capacity Ltrs/Hour=60 (v) Storage capacity= 80 Ltrs (vi) No of Cold water Taps= 1 No(vii) Refrigerant: R-134A (viii) Compressor: Hermatically Sealed with suction gas cooled motor equipped with overload protection.(ix) Condenser Fan: Propeller Type (x) Thermostats: Automatically controls temperature,(xi) Power Supply: 230 V AC+/- 10% , 50 Hz, Single phase, (xii) Water Supply: 3 M to 12 M head(xiii) Power Supply: 5 Amps , 3 pin plug with proper earth connection. Specification of Commercial RO water purifier: 1. Capacity: 50±10 ltrs/hr. 2. Compact Instituiotional RO System with Automatic Flushing. 3. Consist with 2 nos. of booster pump and 4 nos .of RO Membranes. 4. Duty cycle: 500 ltrs/day i.e. 8 10 hrs/day. 5. TDS Rejection: 90±5% 6. Dimensions: W 485 x D 300 x H 840."
Supply installation of Inverter Split Air Conditioner, 1.5 Ton, BEE 5 Star Rated of wall- mounted split type with inverter compressor technology, suitable for efficient cooling with low power consumption. The AC shall have a rated cooling capacity of 1.5 Ton (approximately 5.0-5.2 kW) and shall operate on 230 V AC, 50 Hz single phase power supply. The unit shall be BEE 5 Star rated as per latest BEE norms, with ISEER value not less than 4.6 (or as per current 5-Star classification), ensuring high energy efficiency. It shall be equipped with a high-efficiency rotary inverter 023 compressor, using eco-friendly refrigerant (R-32 or equivalent), suitable for tropical climatic conditions. The indoor unit shall have a low-noise blower, uniform air distribution, washable air filters, and precise temperature control, while the outdoor unit shall be robust, weather-resistant and supplied with a heavy-duty galvanized steel / powder-coated mounting bracket for fixing the outdoor unit. The scope shall include supply and installation of required low-pressure (suction) and high-pressure (liquid) copper connecting pipes of suitable diameter and thickness, properly insulated, of required length as per site installation conditions, complete with flare nuts and fittings, ensuring leak-proof operation.The AC shall include standard safety and protection features such as overload protection, voltage fluctuation protection, and auto-restart.
Supply, laying of GI pipe 50 dia having hot-dip galvanized configuration with zinc coating as per IS 4736 to ensure corrosion resistance(Medium Gauge )
Supplying and laying of following DWC HDPE pipe 63 mm dia (OD-63 mm & ID-51 mm 025 nominal) ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.
Supply, fitting, fixing of 200 Amps outdoor type cable junction box, angle frame 026 mounted, dust & vermin proof, complete with rain cap, aluminium basbar of suitable size for TPN, 200 Amps, 415 V made out of 16 SWG CRCA sheet duly painted, Cable Junction Box Size: (lxbxh=450x 450x600 mm). The base of the fedder pillar junction box to be provided with CC foundation of propotion 1:1.5:3( cement, sang,Chips) after connection of Ug cables.
Providing and executing horizontal boring by HDD machine underneath existing road / railway track at a depth of 2.60 metres below ground level, without causing any damage or disturbance to the existing road surface, pavement, or track structure. The boring shall be carried out to the required length with proper alignment and level control.Providing, lowering, and laying 150 mm diameter CI pipe, inside the bored hole for passing underground power/control cables. The 027 supply of CI pipe is included in the scope of this item. The pipe shall be properly positioned, jointed where required, and secured to prevent displacement. The item includes excavation of entry and exit pits, backfilling with suitable material, compaction, disposal of surplus excavated material, and restoration of all disturbed surfaces to their original condition. The rate shall be inclusive of all labour, HDD boring equipment, machinery, materials, handling, transportation, safety precautions, , and all incidental works, complete in all respects as per site conditions and directions of the Engineer-in-Charge.
Supply, fitting, fixing, testing and commissioning of of Indoor Type LT panel board. The panel shall be metal-enclosed, free-standing compartmentalized, modular type suitable for Indoor installation. The panel shall be dust and vermin proof and the enclosure shall provide a degree of protection of not less than IP-52. Control panel shall be fabricated out of 14 SWG cold rolled steel plates & properly supported using angles & channels. The whole panel shall be mounted on a base frame made out of suitable structural, preferably ISMC Channels. Joints of any kind in sheet shall be seam welded, all welding slag grounded off and welding pitwiped smooth with plumber metal. All panels and covers shall be properly fitted and square with the frames and holes in the panel correctly positioned. The Panel shall be fully compartmentalised with front and back opening doors.. When compartment door is opened, busbar and cable alley shall be shrouded by barrier plates. All panels shall be provided with suitable cable alley and vertical bus bar alley.Each cable chamber shall have cable entry from bottom and suitable removable gland plates shall be provided for this purpose. The cable chamber shall be provided with suitable supporting arrangement between the gland plate and terminals, in the middle. The cable chamber shall have a minimum width of 300 mm depending upon the outgoing cables. Each chamber shall be provided with a hinged type door opening away from the cable alley and shall be provided with black flowertype thumb screw which shall ensure tight closing. The edges of the door shall be provided with a neoprene rubber gasket to make the compartment dust proof.. The panel shall consists of the following Switchgears: ( BUS BAR=250 Amps TPN Aluminium) (i)MCCB 4 pole 250 Amps, 65KA BC Ics=100%Icu , Thermal Magnetic OL & SC Protection=1 NO (ii) MCCB 4 pole 125 Amps 25KA BC Ics=100%Icu , Thermal Magnetic OL & SC Protection-4 Nos (iii) MCB TPN 63 Amps C series-1 No. (iv)LED three phase indication lamp RYB for incoming mains. (v) Digital Voltmeter LED indication with inbuilt selector switch (0-500 V) -1 Sets (vi) Digital Ammeter LED indication with inbuilt selector switch (40-400 Amps) -1 Sets
"Supply , installation , testing and commissioning of High mast tower, 20 Mtrs, Top Dia: 150 mm & Bottom Dia:460 mm. Cross section of mast in Polygon( No. of sides) :20 Nos. Thickness: 3 mm top & 4 mm Bottom. with complete accessories(construction as per BS EN 10025 - 1993 or equivalant IS) with provision and fitting of 8 Nos of 150W LED Flood Light luminarie with secondary Lens. The structure shall be of 20 Mtr height in two sections, hot dip galvansied both inside and outside (conforming to IS4759- 1984,IS2629-1985, IS2633-1972) and suitable for wind speed as per IS875 Part III , including base plate of size 690X690X32 mm, Lightning protection final with GI single spike of suitable length, provision for 3 nos of eatrthing terminals at base of mast, Twin dome LED avaiation obstruction light at top of mast, 16 nos of 900mm/30mm(min.) size steel 029 E6.8 grade foundation bolts and Anchor plate of 590 PCD . The Construction of Foundation and PCD is included in scope of work as per manufacturers recomendation.The Mast shall also have raising and lowering system, head frame, hot dip galvanised steel lantern carrige (using 50mm dia B class GI pipe) suitable for fixing 6 nos of LED high mast luminaires symmetrically, trailing cable of 24Amp rating EPR insulated and PVC sheathed 5core X 2.5 sq.mm copper conductor cable and other wiring materials for luminaires, integral power tool (415V, 3phase, 1HP - 2mtr per minute single speed motor reversible) installation inside the base compartment, 2 nos of continuous 6mm stainless steel wire ropes(7/19 construction), double drum winch (manual and electrical both) as per IS 807, Feeder type control panel for operation of luminaires with astromical ON/OFF timers with suitable MCBs, contractors for automatic control of luminairs, power tool control(Induction Motor) and raise lower push button etc., complete as required. "
Supply, installation, testing and commissioning of energy efficient 7.5KW/10 HP 030 multistage submersible pumping set, discharge capacity: ( 240-1080) LPM for a head of (63-16) Mtrs , outlet pipe size: 80 mm,The Pump should carry a warranty of 12 Months from the date of commissioning.
Supply of energy efficient 7.5KW/10 HP multistage submersible pumping set, discharge capacity: ( 240-1080) LPM for a head of (63-16) Mtrs , outlet pipe size: 80 mm,The
Supply, installation, testing & commissioning of Automatic Star Delta Starter in sheet steel enclosure For 7.5HP/10 KW pump with Robust 4 pole contactor, Overload relay with built in single phase preventor, Relay Amps 8.9-13.5 Amps with Electronic Star delta timer suitable for 415 032 V. 50Hz. AC supply made out of 16 SWG CRCA sheet. The panel shall be totally enclosed, dust & vermin proof, neoprene gasket of thickness not less than 2 mm shall be used between all adjacent units & beneath all covers so that the joints are effectively dust vermin proof. The panel shall have uniform height & depth and pdg. with insulated & spring loaded thumb screws. The busbar chamber shall have 3 phase & neutral Cu. busbar. The panel shall be complete with PVC insulated Cu. wire & shall be ready for connection to the equipments.
Supply of Automatic Star Delta Starter in sheet steel enclosure For 7.5HP/10 KW 033 pump with Robust 4 pole contactor, Overload relay with built in single phase preventor, Relay Amps 8.9-13.5 Amps with Electronic Star delta timer suitable for 415 V. 50Hz. AC supply made out of 16 SWG CRCA sheet. The panel shall be totally enclosed, dust & vermin proof, neoprene gasket of thickness not less than 2 mm shall be used between all adjacent units & beneath all covers so that the joints are effectively dust vermin proof. The panel shall have uniform height & depth and pdg. with insulated & spring loaded thumb screws. The busbar chamber shall have 3 phase & neutral Cu. busbar. The panel shall be complete with PVC insulated Cu. wire & shall be ready for connection to the equipments.
Supply, laying of GI pipe 80 mm dia having hot-dip galvanized configuration with zinc coating as per IS 4736 to ensure corrosion resistance(Heavy Gauge with necessary GI flange
Supply,laying,fixing and connection of Flat 6.0 SQ mmThree Core PVC Insulated & PVC Sheathed Industrial copper Cable for Submersible Pump Motors 1100 Volt, conforming to IS 694.
Supply, fitting, fixing of Cast Iron body (confronting to IS 210) Non return valve 80 mm dia having Nitrile Rubber ''O'' RINGS for leak tightness and stainless steel flap pins to resist corrosion.
B-At SPTR: Provision of Goods office, shed, labour and merchant room,
Supply, fitting, fixing, testing & commissioning of wiring materials for concealed type 001 wiring of light point from main/sub-main board to the points by 1.5 mm.sq.single core multi-strand FRLS copper cable through heavy duty PVC pipe complete with modular type switch 6 A, ceiling rose, GI box with suitable modules for fixing switches.
Supply, fitting, fixing, testing & commissioning of wiring materials for concealed type 002 wiring of Fan Point/Exhaust fan point from main/sub-main board to the points by 1.5 mm.sq.single core multi-strand FRLS copper cable through heavy duty PVC pipe complete with modular type switch 6 A,ceiling rose,Modular GI metal box with suitable modules for fixing switches & Regulators and 1.0 sq mm multistrand FRLS copper Cable in green for earth contuinity wire .
Supply, fitting, fixing, testing & commissioning of Electronic fan Regulator 100 W .
Supply, fitting, fixing, testing & commisioning of wiring materials for concealed type 004 wiring 5 A plug point from main/sub-main board to the points by 1.5 mm. sq. single core multi-strand FRLS copper cable through heavy duty PVC pipe complete with modular type switch & socket 5 A,GI metal box with Suitable modules for fixing switch/socket with 1.0 mm² unsheathed FRLS copper cable in green colour for earth continuity wire.
Supply, fitting, fixing, testing & commisioning of wiring materials for concealed type 005 wiring 15 A plug point from main/sub-main board to the points by 4 mm. sq. single core multi-strand FRLS copper cable through heavy duty PVC pipe complete with modular type switch & socket 15 A , GI metal box with Suitable modules for fixing switch/socket with 1.0 mm² unsheathed FRLS copper cable in green colour for earth continuity wire.
Supply, fitting , fixing of surface mounted LED Batten 20W, 4 Ft, ultra slim co- extruded polycarbonate channel with integrated electronic driver should be as per IEC: 006 62384/IS:16104( SMPS based constant current output, THD<20%), IP20 protection, color temperature=6500K, rated input voltage=230V AC, 50 Hz, power factor=0.9, view angle>=120°, lumens output not less than 100 lm/Watt, operating voltage range: 140-270 V AC. LED Should be as per LM-80/IS:16105. Fixture Size:(LXWxH=1156x25x35 mm +/-1) . The fitting should be warranted for 5 Years.
Supply and fitting , fixing of 18 Watt LED ,Slim, compact, auminum die cast edge lit panel light , recess mounted square fixture with opal diffuser and separate electronic driver. Ceiling Cut Out (210x210 mm).
Supply, fitting, fixing of exhaust fan 300 mm sweep,230V AC,50Hz metallic louver type
Supply, drawing and connection of single core 6 sq. mm PVC insulated & unsheathed multistrand FRLSH copper cable conforming to IS: 694 for voltage grade upto 1100 Volts , as per direction of supervisor incharge at site.
Supply, drawing and connection of single core 4 sq. mm PVC insulated & unsheathed multistrand FRLSH copper cable conforming to IS: 694 for voltage grade upto 1100 Volts , as per direction of supervisor incharge at site.
Supply, drawing and connection of single core 2.5 sq. mm PVC insulated & unsheathed multistrand FRLSH copper cable conforming to IS: 694 for voltage grade upto 1100 Volts , as per direction of supervisor incharge at site.
Supply, fitting, fixing, testing & commissioning of wall mounted type 6 way double door SPN MCB DB having IP 43 protection,Shrouded Neutral Bar & Bus Bar, Cement Spill Protector & 012 Door Earthing with the following domestic switchgears:- :- i) 240/415V, 50Hz, 10kA BC "C" series SP 32 Amps. MCB (In accordance with IS/IEC 60898-1) = 2 No. ii) 240V, 50Hz, with 10kA BC "C" series SP 16 Amps. MCB (In accordance with IS/IEC 60898-1) = 2 Nos. (iii) 240V, 50Hz, with 10kA BC "C" series SP 10 Amps. MCB (In accordance with IS/IEC 60898-1) = 2 Nos.
Supply, installation, testing and commissioning of VTPN Distribution Board System 013 type 4 way double door, IP 43 Protection with MCCB as incomer with the following switchgears: (i) MCCB, 4 pole, 100 Amps, 16 KA BC= 1 No (ii) MCB , SP, 63 Amps, 'C' series=4 Nos. (iii) MCB, SP, 32 Amps, 'C' series=3 Nos
Earthing by 50 mm dia, 3.6 mm thickness 3 Mtrs long GI pipe and 6 SWG GI wire,GI 014 nuts,bolts including masonary materials for earthing pit,salt,charcoal etc. and construction of earth pit covered with CI plate having locking arrangement and watering pipe as per Drawing No PCEE/ELG/DRG/2024/1 Dtd 30.09.2024
Supply, laying, connection, testing and commissioning of LT XLPE Insulated, Cores Laid Up, PVC Inner sheathed, Armoured stranded aluminum conductor cable size 25 mm.sq. 4 core having Galvanized steel Strip, Extruded PVC Type ST2 Sheathed, 650/1100V Grade As Per IS 7098(Part 1) 1988. For laying of above cable digging of trench and excavation of earth/concrete to 015 depth 0.75 Mtrs. and breadth 0.5 Mtrs. below the ground level and a layer of sand of 0.075 Mtrs. thickness shall be spread over the ground before laying the cable and the cable shall be covered with a layer of sand of 0.075 Mtrs. thickness. The bottom of cable trench shall be leveled and got rid of any sharp material. The cable route markers should be provided along the route of cables to indicate their presence so that damage/accident are Not caused by inadvertent digging. (For HM Towers)
Supply, laying,connection, testing and commissioning of cable size 16 mm.sq. 2 core ,LT XLPE Insulated, Cores Laid Up, PVC Inner sheathed, Armoured cable having Aluminium Strip, Glavanised Wire Solid Aluminum Conductor, Extruded PVC Type ST2 Sheathed, 650/1100V Grade As 016 Per IS 7098(Part 1) 1988. For laying of above cable digging of trench and excavation of earth/concrete to depth 0.75 Mtrs. and breadth 0.5 Mtrs. below the ground level and a layer of sand of 0.075 Mtrs. thickness shall be spread over the ground before laying the cable and the cable shall be covered with a layer of sand of 0.075 Mtrs. thickness. The bottom of cable trench shall be leveled and got rid of any sharp material. The cable route markers should be provided along the route of cables to indicate their presence so that damage/accident are Not caused by inadvertent digging.
a) Supply and erection of single arm type Hot Dip Galvanized in single deep to average 65 micron DFT 7 mtr. long octagonal pole similar to NEZONE cat. No. NZOP7 with sectional dia 130x70 mm, overall sectional thickness 3 mm complete with base plate size 220x220x12 mm, 4 Nos. 700 mm long foundation bolt of 20 mm dia with all other accessories as per direction of Engineer in charge at site. b) Supply and erection of PCC/RCC/shallow foundation of size and depth 017 as per recommendation and drawing of the manufacturer (approx. 1.6 mtr.x 0.6 mtr.x0.6 mtr.) with excavation of earth for foundation of all depth and all places, nature and condition of soil including de-watering, shoring, shuttering, batching, mixing, placing, leveling, carrying etc and re-filling the pit after completion of foundation work from excavated earth or borrowed pit by contractor's own arrangement for octagonal poles. Drawing of foundation details, loading, sectional plan bar bonding schedule etc. should be submitted before execution to get the approval from Rly. competent authority. c) Supply and erection of suitable size galvanized single arm bracket 1.5 mtr. long along with spigot for holding/supporting one no. street light fitting.
Supply and installation of Desert cooler 55 Ltrs tank capacity having coverage area of 018 1200 sq feet and air delivery rate of 12000 meter cube per hour with cooling pads of honeycomb type and fan size 16 inch with motor capacity of 650watt(having copper windings) and speed of 2600rpm with air throw distance of 100 feet with features of inverter compatibility,ice chamber,auto fill and drain,castor wheel,auto louver movement with thermal overhead protection,water level indicator having body of high grade,rust-resistant plastic for durability and lightweight design
Supply, installation testing and commissioning of Energy Efficient Ceiling Fan 1400 019 mm sweep BLDC motor, BEE 5 star rated ceiling fan With regulator enable motor with power of 28 watt with 10% tolerance , motor insulation B type 220-240V 50Hz single phase with Speed minimum 350 rpm minimum air delivery 225CMM complete set of 3 no's. blade , down rods, 2 nos canopies , shackle kit & all remaining accessories including nut bolts Washers complete as required .
Supply, fitting, fixing of LED Street Light 45 W to be fixed on octagonal pole. Specification of 45 W Street light : Housing: Pressure die-cast aluminium alloy for housing (heat sink) for effective thermal management, sturdiness & excellent corrosion resistance. Cable gland is used for maintaining ingress protection, Finish: Epoxy powder coated siemens grey after 020 phosphochromate treatment,Light source :High efficiency long life LED chip in modules with lumen efficacy of 140 lm/W with PC lens to ensure better uniformity of light distribution. Cover: Tempered protective toughened glass, thermal, shock and impact-resistant, fixed to the housing with SS screws. Electronic Driver: Built-in potted electronic LED driver with APFC (SMPS based constant current supply), lower THD, Open Circuit protection, Phase to Phase protection, Over Voltage protection, Surge Voltage protection & other safety tests as per IS 15885 Part-2/Sec 13.
"Supply, installation, testing and commissioning of Water cooler storage capacity 80 Ltrs, cooling capacity : 60ltrs/hr with RO commercial water purifier. Specification of water cooler: (i) Dimension: Width: 640 mm, Depth: 450 mm Height:1350 mm (ii) Weight without water: 85Kg (iii)Maximum Current(Amps)=5Amps (iv) Cooling capacity Ltrs/Hour=60 (v) Storage capacity= 80 Ltrs (vi) No of Cold water Taps= 1 No(vii) Refrigerant: R-134A (viii) Compressor: Hermatically Sealed 021 with suction gas cooled motor equipped with overload protection.(ix) Condenser Fan: Propeller Type (x) Thermostats: Automatically controls temperature,(xi) Power Supply: 230 V AC+/- 10% , 50 Hz, Single phase, (xii) Water Supply: 3 M to 12 M head(xiii) Power Supply: 5 Amps , 3 pin plug with proper earth connection. Specification of Commercial RO water purifier: 1. Capacity: 50±10 ltrs/hr. 2. Compact Instituiotional RO System with Automatic Flushing. 3. Consist with 2 nos. of booster pump and 4 nos .of RO Membranes. 4. Duty cycle: 500 ltrs/day i.e. 8 10 hrs/day. 5. TDS Rejection: 90±5% 6. Dimensions: W 485 x D 300 x H 840."
Supply installation of Inverter Split Air Conditioner, 1.5 Ton, BEE 5 Star Rated of wall- mounted split type with inverter compressor technology, suitable for efficient cooling with low power consumption. The AC shall have a rated cooling capacity of 1.5 Ton (approximately 5.0-5.2 kW) and shall operate on 230 V AC, 50 Hz single phase power supply. The unit shall be BEE 5 Star rated as per latest BEE norms, with ISEER value not less than 4.6 (or as per current 5-Star classification), ensuring high energy efficiency. It shall be equipped with a high-efficiency rotary inverter 022 compressor, using eco-friendly refrigerant (R-32 or equivalent), suitable for tropical climatic conditions. The indoor unit shall have a low-noise blower, uniform air distribution, washable air filters, and precise temperature control, while the outdoor unit shall be robust, weather-resistant and supplied with a heavy-duty galvanized steel / powder-coated mounting bracket for fixing the outdoor unit. The scope shall include supply and installation of required low-pressure (suction) and high-pressure (liquid) copper connecting pipes of suitable diameter and thickness, properly insulated, of required length as per site installation conditions, complete with flare nuts and fittings, ensuring leak-proof operation.The AC shall include standard safety and protection features such as overload protection, voltage fluctuation protection, and auto-restart.
Supply, fitting, fixing, testing and commissioning of of Indoor Type LT panel board. The panel shall be metal-enclosed, free-standing compartmentalized, modular type suitable for Indoor installation. The panel shall be dust and vermin proof and the enclosure shall provide a 023 degree of protection of not less than IP-52. Control panel shall be fabricated out of 14 SWG cold rolled steel plates & properly supported using angles & channels. The whole panel shall be mounted on a base frame made out of suitable structural, preferably ISMC Channels. Joints of any kind in sheet shall be seam welded, all welding slag grounded off and welding pitwiped smooth with plumber metal. All panels and covers shall be properly fitted and square with the frames and holes in the panel correctly positioned. The Panel shall be fully compartmentalised with front and back opening doors.. When compartment door is opened, busbar and cable alley shall be shrouded by barrier plates. All panels shall be provided with suitable cable alley and vertical bus bar alley.Each cable chamber shall have cable entry from bottom and suitable removable gland plates shall be provided for this purpose. The cable chamber shall be provided with suitable supporting arrangement between the gland plate and terminals, in the middle. The cable chamber shall have a minimum width of 300 mm depending upon the outgoing cables. Each chamber shall be provided with a hinged type door opening away from the cable alley and shall be provided with black flowertype thumb screw which shall ensure tight closing. The edges of the door shall be provided with a neoprene rubber gasket to make the compartment dust proof.. The panel shall consists of the following Switchgears: ( BUS BAR=250 Amps TPN Aluminium) (i)MCCB 4 pole 250 Amps, 65KA BC Ics=100%Icu , Thermal Magnetic OL & SC Protection=1 NO (ii) MCCB 4 pole 125 Amps 25KA BC Ics=100%Icu , Thermal Magnetic OL & SC Protection-4 Nos (iii) MCB TPN 63 Amps C series-1 No. (iv)LED three phase indication lamp RYB for incoming mains. (v) Digital Voltmeter LED indication with inbuilt selector switch (0-500 V) -1 Sets (vi) Digital Ammeter LED indication with inbuilt selector switch (40-400 Amps) -1 Sets
Supply, installation, testing and commissioning of energy efficient 7.5KW/10 HP 024 multistage submersible pumping set, discharge capacity: ( 240-1080) LPM for a head of (63-16) Mtrs , outlet pipe size: 80 mm,The Pump should carry a warranty of 12 Months from the date of commissioning.
Supply of energy efficient 7.5KW/10 HP multistage submersible pumping set, discharge capacity: ( 240-1080) LPM for a head of (63-16) Mtrs , outlet pipe size: 80 mm,The
Supply, installation, testing & commissioning of Automatic Star Delta Starter in sheet steel enclosure For 7.5HP/10 KW pump with Robust 4 pole contactor, Overload relay with built in single phase preventor, Relay Amps 8.9-13.5 Amps with Electronic Star delta timer suitable for 415 026 V. 50Hz. AC supply made out of 16 SWG CRCA sheet. The panel shall be totally enclosed, dust & vermin proof, neoprene gasket of thickness not less than 2 mm shall be used between all adjacent units & beneath all covers so that the joints are effectively dust vermin proof. The panel shall have uniform height & depth and pdg. with insulated & spring loaded thumb screws. The busbar chamber shall have 3 phase & neutral Cu. busbar. The panel shall be complete with PVC insulated Cu. wire & shall be ready for connection to the equipments.
Supply of Automatic Star Delta Starter in sheet steel enclosure For 7.5HP/10 KW pump with Robust 4 pole contactor, Overload relay with built in single phase preventor, Relay Amps 8.9-13.5 Amps with Electronic Star delta timer suitable for 415 V. 50Hz. AC supply made out of 16 027 SWG CRCA sheet. The panel shall be totally enclosed, dust & vermin proof, neoprene gasket of thickness not less than 2 mm shall be used between all adjacent units & beneath all covers so that the joints are effectively dust vermin proof. The panel shall have uniform height & depth and pdg. with insulated & spring loaded thumb screws. The busbar chamber shall have 3 phase & neutral Cu. busbar. The panel shall be complete with PVC insulated Cu. wire & shall be ready for connection to the equipments.
Supply, laying of GI pipe 80 mm dia having hot-dip galvanized configuration with zinc coating as per IS 4736 to ensure corrosion resistance(Heavy Gauge with necessary GI flange
Supply,laying,fixing and connection of Flat 6.0 SQ mmThree Core PVC Insulated & PVC Sheathed Industrial copper Cable for Submersible Pump Motors 1100 Volt, conforming to IS 694.
Supply, fitting, fixing of Cast Iron body (confronting to IS 210) Non return valve 80 mm dia having Nitrile Rubber ''O'' RINGS for leak tightness and stainless steel flap pins to resist corrosion.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].