Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.8 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹15.0 L+₹1.2 L (8.71%)Rejected-AOC PLOT NO 28 SANTOSHIMA COLONY WEST MARREDPALLY SECUNDERABAD 500026 | HYDERABAD | TELANGANA | 500026 | L2 | Rejected-AOC Being not L1 | |
| 3 | L3₹18.4 L+₹4.7 L (33.9%)Rejected-AOC | L3 | Rejected-AOC Being not L1 |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
5 Mar 2022, 6:00 pmClosed
Shri M Saravanan, IDSE, GE
Garrison Engineer North 35 Allenby Lines Secunderabad 500087
COMPREHENSIVE REPAIRS TO COOLING APPLIANCES WATER COOLERS DESERT COOLERS, SPLIT WINDOW ACs DEEP FREEZERS AND REFRIGERATORS UNDER AGE EM N OF GE NORTH SECUNDERABAD
2022_MES_506116_1
GE/N/SEC OF 2021-22 (8560/E8)
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Garrison Engineer North 35 Allenby Lines Secundera
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GARRISON ENGINEER NORTH SECUNDERABAD
₹30,000
Yes
23 Mar 2022
5 Feb 2022
7 Mar 2022
5 Feb 2022
5 Mar 2022
19 Feb 2022
Amount
Material and labour for cleaning and servicing of Split Type 1.5 Ton AC including repair of all loose electrical connections, abnormal noise in indoor/outdoor unit, foundation, power contactor etc including TOP UP of suitable gas complete all as specified and directed. Note: Replacement of any spares will be measured and paid separately
Material and labour for checking the leakage of Split type 1.5 Ton AC with the help of N2 Gas and after defecting and repairing the leakage, charge the suitable refrigerant upto required level as specified on the unit complete all as specified and directed. Note: Replacement of capillary tube will be paid and measured separately
Supply and fixing in replacement of spares for Split AC 1.5 Ton of suitable make as per sample complete all as specified and directed. (a) 1/2 inch copper pipe along with insulation material
(b) 1/4 inch copper pipe along with insulation material
(c) 5/8 inch copper pipe along with insulation material
(d) Capacitor 45+/- 2 mfd
(e) Capacitor 60+/-6 mfd
(f) Capacitor 4 mfd
(g) Capacitor 6 mfd
(h) Panel Board of suitable make as per sample
(j) Fan blade
(k) Fan motor
(l) Condenser coil unit complete
(m) valve of 1/2 or 1/4 or 5/8
(n) Flarry nut 1/4, 3/8, 5/8 and 1/2
(o) Evaporator Coil
(p) Indoor motor
(q) Swing motor complete of suitable size as per sample
(r) swing blade
(s) Room sensor
(t) coil sensor
(u) Dead plug of Brass Type
(v) Complete Rewiring of Outdoor Split AC
(w) Universal Remote
(x) Replacement of Indoor Unit capacity 1.5 Ton complete set as per sample and existing Make.
(y) Replacement of Outdoor Unit capacity 1.5 Ton complete set as per sample and existing Make.
(z) Contactor for Inverter type AC
(aa) PCB Board of Inverter type AC
(ab) Air Sensor of Inverter type AC
(ac) Coil Sensor of Inverter type AC
(ad) Heavy duty compressor terminal Pin
(ae) Inlet water PVC pipe 20mm dia along with clamps
(af) Flexible PVC pipe of 20mm dia as per sample
Supply and Fix in replacement of Outdoor unit for 1.5 Ton split AC Stand for fixing in wall complete all as specified and directed.
Disconnecting the Electrical connection, removing the copper line, discharge line of Split AC 1.5 Ton capacity including indoor and outdoor units and all accessories and shifting/re-installing and testing the whole unit of Split AC in new location and checking the leakage of Split type 1.5 Ton AC with the help of N2 Gas and after defecting and repairing the leakage, charge the suitable refrigerant upto required level as specified in suitable size and length of copper pipe and making the holes in wall complete all as specified and directed.
Supply and Fix in replacement of Factory made hermatically sealed compressor including rubber bushes sleeves, washers, nuts and bolts, terminal covers, clips etc complete all as specified for the following items with capacities of any make including necessary transport from units to work shop and back to units after repairs complete all as specified and directed. (a) Split Type AC 1.5 Ton capacity Note 1: Rates deemed to be included for servicing, repairs and replacement of all connected parts, transportation of cooling appliances to work shop and back. Note 2: Rates deemed to be included for the gas required for charging.
Supply and Fix in replacement of Sheet metal single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB SP 230 Volts of 25-32 Amps capacity complete all as specified and directed.
Supply and Fix in replacement of Plug Tops of 16 Amps complete all as specified and directed.
Material and Labour for repairs of Split/cassette AC i.e water drain leakage problem detection and refitting the same in entire system including testing and commissioning complete serviceable for Split AC 1.5 Ton complete all as specified and directed.
M & L for Water cooler servicing and including supply and charging of refrigerant R-134a/Suitable Refrigerant including cost of welding, leak detection, making good the defects in entire system, testing and commissioning of water coolers of 40/80 ltrs capacity complete all as specified and directed.
Supply and Fix in replacement of Factory made hermatically sealed compressor including rubber bushes sleeves, washers, nuts and bolts, terminal covers, clips etc complete all as specified for the following items with capacities of any make including necessary transport from units to work shop and back to units after repairs of Water Coolers 40/80 Ltrs complete all as specified and directed. Note 1: Rates deemed to be included for servicing, repairs and replacement of all connected parts, transportation of cooling appliances to work shop and back. Note 2: Rates deemed to be included for the gas required for charging
Supply and fixing in replacement of following spares for Water coolers of 40/80 Ltrs capacity complete all as specified and directed. (a) Relay package assembly as per Existing Model
Thermostat/cooling sensor complete unit complete all as specified and directed.
Capillary tube including filter/stainer complete all as specified and directed.
Condenser fan motor 1/16 HP 230 volts including blades complete all as specified and directed.
PVC Ball valve high pressure with polythene float and fly nut complete for iron pipe 15mm dia complete all as specified and directed.
Magnetic door gasket for complete unit and complete all as specified and directed.
GI/Stainless steel water drain tray complete all as specified and directed.
Self closing taps, cast copper alloy, chromium plated screwed for iron pipe 15mm dia complete all as specified and directed.
Timer switch
PCB as per sample
OLP as per sample
Fan motor
Fan blade
Capacitor 10-15 mfd
Blower as per sample
Supply and Fixing in replacement of spares for Desert Cooler of any make and size complete all as specified and directed. (a) Water circulating pump 1/70 HP capacity single phase 230 Volts 1340 RPM 1.5 Mtr Head
Khas-Khas screen complete set for Each Cooler complete all as specified and directed.
Float valve suitable for any type of desert coolers 230 volts 50 Hz complete all as specified and directed.
PVC Pipe suitable for any type desert cooler 230 volts 50 Hz complete all as specified and directed.
Fan motor double speed 230 volts 50 Hz 1/13 HP complete set and complete all as specified and directed.
Swing Motor
Swing Blade
Fan Blade
Distributor complete set
Supply and fix steel water tubing of medium grade duly ISI marked galvanised of 15mm dia bore including all fittings such as tees, bends and elbow reducer, unions, clamps including cutting the existing line and connecting complete all as specified and directed.
M & L for Refrigerator servicing and including supply and charging of refrigerant R-134a/Suitable Refrigerant including cost of welding, leak detection, making good the defects in entire system, testing and commissioning of Refrigerator of 260 to 310 ltrs capacity complete all as specified and directed.
Supply and Fix in replacement of Factory made hermatically sealed compressor including rubber bushes sleeves, washers, nuts and bolts, terminal covers, clips etc complete all as specified for the following items with capacities of any make including necessary transport from units to work shop and back to units after repairs of Refrigerator of 260 to 310 ltrs capacity complete all as specified and directed. Note 1: Rates deemed to be included for servicing, repairs and replacement of all connected parts, transportation of cooling appliances to work shop and back. Note 2: Rates deemed to be included for the gas required for charging.
Supply and fixing in replacement of following spares for Refrigerator of 260 to 310 ltrs capacity complete all as specified and directed. (a) Relay package assembly as per Existing Model
Thermostat/cooling sensor
Capillary tube including filter/stainer
Condenser fan motor 1/16 HP 230 volts including blades complete all as specified and directed.
Magnetic door gasket for complete unit
PVC body tray
Fan Blade
cooling coil/freezer
condenser
Biometer Fuse
Heater
Timer
Time delay
Door lock with Key
Supply and fixing in replacement of following spares for voltage stabilizer of single phase upto 5 KVA capacity complete all as specified and directed. (a) Rectifier unit as per sample
Relay unit as per sample
Indication lamp set
Power supply control card
Low cut High cut Time delay card
9-0-9/12-0-12 Transformer
Power connectors
Main Transformer Circuit
S & F MCB SP 6 to 32 Amps 240 volts for fixing on MCB DB's complete all as specified and directed.
M & L for MCB TP, 415 volts suitable for fixing on MCB DB of capacity 63/40 Amps including removing the existing unserviceable one and making good the distrubed surface to match with the existing surface complete all as specified and directed.
S & F in replacement sheet metal enclosure MCB DB SPN 8 way with 200 amps rated bus bar 240 volts double door with locking system complete all as specified and directed.
S & F in replacement Horizontal type TPN DB 4 way double door made out of CRCA sheet housing with powder coating & confirming to IS 13032, IS 8623, BS 5486 accommodated suitably in a MS enclosure weather proof made out of 3 mm thick MS sheet having hinged and robust locking arrangement including painting by red-oxide one coat and powder coated complete all as specified and directed.
All as per Sl item No 96 here in before, but VTPN 4 way DB Suitable for MCCB 63/100Amps complete all as specified and directed.
M & L Submain wiring with 2 runs of single core 4 sqmm PVC insulated sheated multistranded FR 1100 volts grade with copper conductor drawn through non-metallic rigid PVC conduit and conduit accessories of medium grade not not less than 25mm dia including one run of single core 4 sqmm PVC insulated sheated multistranded 1100 volts grade with copper conductor cable as earth continuity conductor along with the wiring and connected from DB to DB/main board including removing the existing unserviceable submain wiring complete all as specified and as directed. Note: 3 runs of copper cable and 1 run of conduit shall be measured and paid as one unit length.
All as per Sl item No 98, but 2runs of single core 6 sqmm and one run of single core 6 sqmm as earth continuity conductor complete all as specified and directed. Note: 3 runs of copper cable and 1 run of conduit shall be measured and paid as one unit length.
M&L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc as required 4mm dia galvanised iron or steel wire complete all as specified and directed.
M&L for Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of Landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth complete all as specified and directed.
Supply & Replace MCCBs 415V,10KA, 63/100 amps 3 Pole suitable for DB including removing the existing unserviceable one and making good the distrubed surface to match with the existing surface complete all as specified and directed.
Supply & Replace MCCBs 415V,10KA, 125/160 amps 3 Pole suitable for DB including removing the existing unserviceable one and making good the distrubed surface to match with the existing surface complete all as specified and directed.
Supply and replace PVC Dummy sheets circular type of 4"
Supply and replace PVC Dummy sheets circular type of 6"
Supply and replace Rigid PVC casing & capping 20/25 mm wide
Supply and replace Piano switch 6 Amps
Supply and replace PVC rectangular box (Gang box) with 5 Amps switch socket
Supply and replace PVC rectangular box (Gang box) with 5/15 Amps switch socket
Supply and replace PVC wire of Flexible cord with copper conductor multistanded of twin core 0.5 sqmm
Supply and replace 3 core PVC copper wire of 1.5 Sq mm
Supply and replace 3 core PVC copper wire of 2.5 Sq mm
Supply and replace Service wire twin core of 10.0 Sq mm aluminium type flat unarmoured
Supply and replace Plug top 5 Amps 3 pin 230 Volts
Supply and replace Plug top 15 Amps 3 pin 230 Volts
M&L for servicing of Deep Freezer servicing and including supply and charging of refrigerant R-22 or any type gas including cost of welding, leak detection, making good the defects in entire system, testing and commissioning of Refregerator of 320 to 400 ltrs capacity complete all as specified and directed
Supply and Fix in replacement of factory made hermatically sealed compressor including rubber bushes sleeves, washers, nuts and bolts, terminal covers, clips etc for Deep Freezer of capacity 320 to 400 ltrs with all necessary items of any make and transport from units to work shop and back to units after repairs complete all as specified and as directed. Note 1: Rates deemed to be included for servicing, repairs and replacement of all connected parts, transportation of cooling appliances to work shop and back. Note 2: Rates deemed to be included for the gas required for charging.
Supply and fixing in replacement of following spares for Deep Freezer of 320 to 400 ltrs capacity complete all as specified as directed:- (a) Relay package assembly as per Existing Model
(b) Thermostat/cooling sensor
(c) Capillary tube including filter/strainer
(d) Condenser fan motor 1/16 HP 230 volts including blades complete
(e) Magnetic door gasket for complete unit
(f) cooling coil/freezer
(g) condenser
(h) Biometer Fuse
(j) Heater
(k) Timer
(l) Time delay
(m) condenser Motor
Universal refrigeration and Engineering Company
SANTHAM TRADERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .