Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.6 LAccepted-AOC BUDOOBAGH NOWPORA 0 KHANYAR SRINAGAR JAMMU KASHMIR 190003 | SRINAGAR | JAMMU AND KASHMIR | 190003 | L1 | Accepted-AOC BEING L1. | |
| 2 | L2₹7.4 L+₹63,709 (9.38%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN L1. | |
| 3 | L3₹7.8 L+₹97,478 (14.4%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN L1. | |
| 4 | L4₹8.2 L+₹1.4 L (21.2%)Rejected-Finance 4 BATWARA BATWARA BATWARA SRINAGAR JAMMU KASHMIR 190004 | SRINAGAR | JAMMU AND KASHMIR | 190004 | L4 | Rejected-Finance OTHER THAN L1. | |
| 5 | L5₹9.5 L+₹2.7 L (39.7%)Rejected-Finance | L5 | Rejected-Finance OTHER THAN L1. |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
28 Jun 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE 864 EWS
GE 864 EWS BB CANTT SRINAGAR
REPAIR / REPLACEMENT OF SUMMER / WINTER APPLIANCES OF VARIOUS LOCATIONS AT BB CANTT, SRINAGAR
2021_MES_446994_1
864/WS-22/2021-22
Open Tender
Miscellaneous Works
Item Rate
180 days
BB CANTT SRINAGAR
ALL AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE 864 EWS
₹20,000
Yes
14 May 2022
31 May 2021
30 Jun 2021
31 May 2021
28 Jun 2021
14 Jun 2021
60 days
Amount
Taking down the split AC of capacity 1.5/2.0 TR by disconnecting of refrigerant and electrtic connections of the inner and outer unit and removing the AC unit for cleaning/servicing with pressure water to remove oil, grease and dust without spoiling control wiring or damaging of electric motors and apply one coat of clean solution with wire mesh brush/nylon brush on the condensing coils of out door and inner unit including oiling and greasing to all moving parts with replacement of the defective parts, gas charging & testing and re-installing in same position, compete all as specified and directed by Engineer-in-Charge Note :- Spare parts and gas charging shall be measured and paid separately under relevant items.
Disconnecting of electric connection of the window type AC from its stabilizer or its electric board and taking out the unit carefully for carrying out the cleaning / servicing unit with pressure water to remove all dust and sand particles and apply one coat of cleaning solution and clean the unit with wire mesh brush/nylon brush and applying oil and grease to all moving parts including condensing motor and replacing the defective spare parts including testing after re-installing in same position and connecting, complete all as specified and directed by Engineer-in-Charge. Note :- Spare parts and gas charging shall be measured and paid separately under relevant items.
S&F in replacement sealed reciprocating compressor unit for 1.5 TR window type AC, complete all as specified and directed. Make :- Panasonic / Danfoss / Voltas / Hitachi / Mitsubishi
S&F in replacement sealed reciprocating compressor unit for 1.5 TR split type AC, complete all as specified and directed. Make :- Panasonic / Danfoss / Voltas / Hitachi / Mitsubishi
S&F in replacement sealed reciprocating compressor unit for 2.0 TR split type AC, complete all as specified and directed. Make :- Panasonic / Danfoss / Voltas / Hitachi / Mitsubishi
S&F in repair/replacement kit wiring for window type AC capacity 1.5 TR, complete all as specified and directed. Make :- Napoleon / LG
S&F in replacement drain pipe of PVC, size 15mm, 3 Mtr long, complete all as specified and directed.
S&F in replacement Printed Circuit Board (PCB) for split type AC operating at hot & cold mode of capacity 1.5 / 2.0 Ton, suitable for LG / Godrej / Blue Star ACs, complete all as specified and directed.
S&F in replacement of Printed Circuit Board (PCB) for window type AC operating at hot & cold mode of capacity 1.5 Ton, suitable for LG / Carrier / Usha ACs, complete all as specified and directed.
S&F in replacement front cabinet grill for 1.5/2.0 TR capacity window type AC, suitable for LG / Carrier / Usha ACs , complete all as specified.
S&F in replacement evaporator unit of capacity 1.5 TR comprising of copper tubes and finns including flare nuts and proper pressure testing of the unit for leakage after fixing, complete all as specified and directed. Make :- PATTON / DORIN
S&F in replacement condenser unit of capacity 1.5 TR comprising of copper tubes and finns including flare and dead nuts and proper pressure testing of the unit for leakage after fixing, complete all as specified and directed. Make :- PATTON / DORIN
S&F in replacement evaporator unit of capacity 2.0 TR comprising of copper tubes and finns including flare nuts and proper pressure testing of the unit for leakage after fixing, complete all as specified and directed. Make :- PATTON / DORIN
S&F in replacement condenser unit of capacity 2.0 TR comprising of copper tubes and finns including flare and dead nuts and proper pressure testing of the unit for leakage after fixing, complete all as specified and directed. Make :- PATTON / DORIN
S&F in replacement indoor unit Hot & Cold complete set to match with existing for 1.5 TR split AC consist of motor, cooling coil, remoting system etc. including testing of unit, complete all as specified and directed. Make :- LG / Godrej / Blue Star
S&F in replacement polyvinyle chloride front grille with cabinet cover of inner unit of 1.5/2.0 TR split AC, suitable for LG / Godrej / Blue Star ACs, complete all as specified and directed.
S&F in replacement starting capacitor 80-100 MFD 6 pin, complete all as specified and directed. Make :- Brite / Escorp / Havells
Supply only running capacitor 80-100 MFD, complete all as specified and directed. Make :- Brite / Escorp / Havells
S&F in replacement condenser motor 1/3 HP with fan blade and bracket suitable for split type AC 1.5 TR, complete all as specified and directed. Make :- Synergy / Haier
S&F in replacement inner unit (evaporator) asynchronous motor 25 Watt, 4 Pole, 220-240 Volt with SS single shaft suitable for split type AC 1.5/2.0 TR, complete all as specified and directed. Make :- Synergy / Haier
S&F in replacement control display panel (single line/double line) of split AC of capacity 1.5/2.0 TR, suitable for LG / Godrej / Blue Star ACs, complete all as specified and directed.
S&F in replacement knob suitable for window type AC of capacity 1.5 TR.
S&F in replacement starting relay for window / split type AC 1.5 to 2.0 TR, complete all as specified.
S&F in replacement split AC outdoor unit 1.5 TR consisting of compressor, condenser coil, blower motor with fan etc., complete all as specified and dirceted. Make :- LG / Godrej / Blue Star
Supply and Charging of refrigerant R-22/R-410 (a) after nitrogen flushing and pressure testing of close ciruit (compressor and refrigerant lines) of split / window type AC of any capacity, complete all as specified and directed by Engineer-in- Charge.
Supply only butane in catridge for brazing of copper tube and tube joint of split/window type AC of any capacity, complete all as specified and directed by Engineer-in- Charge.
Supply only teflon tape for ACs of size 25x25mm.
Supply only PVC insulation tape of ACs of size 25x25mm
S&F in replacement of MCB SPN, 32 Amps, 10 KA 'C' curve, complete all as specified and directed. Make :- Havells / Indo Asian / Legrand
S&F in replacement polyvinyle chloride air filter for split type AC of any capacity, complete all as specified and directed.
S&F in replacement polyvinyle chloride air filter for window type A/C of capacity 1.5/2.0 TR make, complete all as specified and directed.
S&F in replacement thermistor for split type AC, suitable for LG / Godrej / Blue Star make, complete all as specified and directed.
S&F in replacement thermistor for 1.5 TR window type AC, suitable for LG / Godrej / Blue Star make, complete all as specified and directed.
S&F in replacement swing motor with wiring leads for inner unit of 1.5/2.0 TR Split AC, suitable for LG / Godrej / Blue Star make, complete all as specified and directed.
S&F in replacement axial PVC blower with end bushes for inner unit of 1.5/2.0 TR split AC, suitable for LG / Godrej / Blue Star make, complete all as specified and directed.
S&F in replacement PVC louver flap complete with links for inner unit of 1.5/2.0 TR split AC, suitable for LG / Godrej / Blue Star make, complete all as specified and directed.
S&F reverse valve by soldering brazzing with reverse coil for Hot & Cold AC of capacity 1.50 TR including extension of refrigerant pipes and testing, complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 37.00 above but suitable for 2.0 Ton AC.
Dismantling of Refrigerator / Deep freezer of any capacity for carrying out repair/replacement of following worn out parts and re-assembling, testing and commisioning of the same after repairing, comlete all as specified and directed by Engineer-in-Charge. Note :- Spares and Gas charging shall be measured and paid seprately under respective items.
Replacement of compressor 'A' type suitable for refrigerator of capacity 165-180 Ltrs. Make : LG / Godrej
Replacement of compressor 'B' type suitable for refrigerator of capacity 190-240 Ltrs. Make :- LG / Godrej
Replacement of compressor 'C' type suitable for refrigerator of capacity 240-410 Ltrs. Make :- LG / Godrej
Replacement of compressor 411 KCN suitable fordeep freezer of capacity 260-600 Ltrs. Make :- LG / Godrej / Haier
Replacement of freezer compartment of Refrigerator of capacity 165-240 Ltrs.
Replacement of condensing coil of Refrigerator of capacity 165-240 Ltrs.
Replacement of freezer compartment of Refrigerator of capacity 240-410 Ltrs.
Replacement of condensing coil of Refrigerator of capacity 240-410 Ltrs.
Recharging of refrigerant R-134(a) including nitrogen flushing, vaccumization and pressure testing, complete all as specified and directed.
S&F copper tubing size 3/8" for Refrigerent gas line with nitrile insulation including making connection with flare nut of same size after cutting every 5 mtr, complete all as specified and directed.
S&F copper tubing size 1/4" for refrigerent liquid line with nitrile insulation including making connection with flare nut of same size after cutting every 5 mtr, complete all as specified and directed.
S&F capillary tube 1/32 "of copper including making connection, complete all as specified and directed.
Isolating the voltage stabilizer of capacity 4/5 KVA single phase by disconnecting all electric connections and dismantling the same for carrying out cleaning and applying one coat spray painting, repairing / replacement of following worn out parts and re-assembling, testing after repairing, complete all as specified and directed by Engineer-in-Charge. Note :- Spare parts shall be measured and paid separately under relevent item.
Rewinding of main transformer of 5/4 KVA with same gauge super enameled copper winding wire complete with insulating materials and varnishing heating for dry up including taking out of burnt/unserviceable winding, complete all as specified and directed by Engineer-in-Charge.
Replacement of printed circuit board for 5/4 KVA voltage stablizer.
Replacement of relays for 5/4 KVA voltage stablizer.
Replacement of voltmeter 0-300 volts.
Replacement of switch/socket terminal of rating 5/15 Amps including control wiring.c
S&F in replacement Quartz tube of heat piller 40cm, complete all as specified and directed. Make :- Gopi or equivalent
S&F in replacement heat element coiled 750 Watt of heat piller, complete all as specified and directed.
S&F in replacement heat resistance connector strip of copper double complete with lugs, complete all as specified and directed.
S&F in replacement switch block eiose flash set of three 15 Amps, complete all as specified and direted.
S&F in replacement propeller fan with blade 100mm, complete all specified and directed. Make :- Gopi or equivalent
S&F in replacement heat resistance connection of copper, complete all as specified and directed. Make :- Gopi or equivalent
S&F in replacement Osillation motor AC 230 Volt, 90 degree cut complete with base, complete all as specified and directed. Make :- Gopi or equivalent
S&F PVC insulated 4 Sqmm flexible cord 4 Core with stranded copper conductor, complete all as specified and directed. Make :- Finolex / Polycab / Havells
S&F PVC insulated 4 Sqmm single core multistranded copper conductor cable, complete all as specified and directed. Make :- Finolex / Polycab / Havells
S&F PVC insulated 2.5 Sqmm single core multistranded copper conductor cable, complete all as specified and directed. Make :- Finolex / Polycab / Havells
S&F PVC insulated 6 Sqmm single core multistranded copper conductor cable, complete all as specified and directed. Make :- Finolex / Polycab / Havells
Supply only nitrile insulation of density 13mm thick suitable for refrigerant tubing of dia 1/2". Make :- Superlon or equivalent
Supply only nitrile insulation of density 13mm thick suitable for refrigerant tubing of dia 1/4". Make :- Superlon or equivalent
Supply only single phase portable AC washing pressure pump C120, 1800 Watt, complete all as specified and directed.
Supply only brazing rod for welding.
Supply only AC stand for outdoor unit of wall brackets with fasteners is suitable for all brands AC out door units powder coated metal wall mounted carring capacity 1.5/2.0 Ton AC, complete all as specified and directed.
Supply only voltage stabilizer 5 KVA single phase input voltage 230 Volt output (+/- 1%) full load upto 20 Amps gives protection againest low voltage, high voltage and over load trip, complete all as specified and dirceted. Make :- Godrej / V Guard or equivalent
S&F in replacement starting capacitors 36-200 MFD 6 pin / 4 pin, complete all as specified and directed. Make :- Brite / Escorp / Havells
S&F indoor unit blower motor with blower 1.5 / 2.0 TR air conditioner of any type & any make as per sample including inverter model, complete all as specified and directed by Engineer-in-Charge.
S&F outdoor unit fan motor with fan1.5 / 2.0 TR AC of any type and any make as per sample including inverter model, complete all as specified and directed.
Supply only remote control for 1.5 / 2.0 TR inverter/Non inverter airconditioner of any type and make as per sample.
ORISON ENTERPRISES
M/S M.A.S ELECTRICALS
M/S FAISAL TRADING CO.
M/S SMA and SONS CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .