Tender Value
₹42.6 L
EMD Value
₹85,200
Closing Date
5 Dec 2023, 6:00 pmClosed
Sh Sachin Jaiswal, IDSE, CWE Chandimandir
HQ CWE Chandimandir
CA NO. CWE/CHD-64/2023-24 PROVN OF WKS AND SERVICES FOR EST OF A REGIONAL NEAR LINE DATA CENTRE (R-NLDC) UNDER PROJ NETWORK FOR SPECTRUM (NFS) AT N AREA UNDER GE CHANDIGARH
2023_MES_626974_1
CWE/CHD-64/2023_24
Open Tender
Miscellaneous Works
Item Rate
180 days
HQ CWE Chandimandir
Class D category b(ii)
8 documents required · 8 mandatory
₹500
Yes
GE Chandigarh
₹85,200
Yes
23 Jan 2024
6 Nov 2023
11 Dec 2023
6 Nov 2023
5 Dec 2023
21 Nov 2023
7 Nov 2023 - 13 Nov 2023
Amount
Material and labour for point wiring with 1.5 sq mm copper conductor FRLS (multistrand) PVC insulated ISI marked unseathed cable in and including concealed , non metalic rigid PVC conduit medium grade ISI marked, conduit not less than 19 mm with all fittings & other accessories and also including PVC insulated ISI marked unseathed FRLS cable of size 1.5 sq mm copper conductor as earth wire to common earth dolly including concealed in wall/ceiling, modular MS Box, 1.6mm thick with modular cover plate with frame , sockets, fan regulator etc for One light/fan point controlled by one way switch complete all as specified & directed. : Note:- (i). cable Colour should beas per IS code. (ii). Modular switch sockets fan regulators shall be measured and paid separately under respective items. (iii). Cost of mudular MS box , modular cover plate and frame of any modules as required at site and as directed by Engineer-in-charge is deemed to be included in th quoted rates.
One light point/fan/ point controlled by one switch complete all as specified & directed
Supply and fixing modular switch 6Amp, 230 volts piano flush type universal single pole one way ISI marded with IS 3854 : 1997 or IS having finger proof terminals with captive screws having front fixing & removing geatures without removing plates complete all as specified & directed .
Supply and fixing ceiling rose, surface type Bakelite 65x55mm 3 terminal isolated body complete all as specified & directed
Supply and fixing Recess mounting 38 Watt LED luminaires 2' x 2' with CRCA white matte powder coated housing, polycarbonate with light transmission > 85% complete with all accessories including 36 Watt LED Lamp. complete all as specified and as directed.
Supply and fix exhaust fan, steel body AC single Phase. 230V of size 450mm sweep heavy duty with, blades, and frame and louvers complete all as specified and as directed.
Supply and fixing Cable alinuminium ducting (Size Width 5 - 10 inch 2 Meter Long) complete all as specified and as directed.
Supply and fixing Anti static mats (Size 2.0 mm x 1.0 Mtr with 2.0 Mtr long )complete all as specified and as directed.
Supply, Installation, testing and commissioning of floor mounted Air Cooled Package Units DX type of cap 11.0 TR with scroll type compressor, S&T Cond., Microprocessor based control panel for operation on refrigerant R-407 C complete with 1st charge of refrigerant gas & oil etc. complete all as specified and as directed.
Supply, Installation, testing and commissioning of floor mounted Air Cooled Package Units DX type of cap 5.5 TR with scroll type compressor, S&T Cond., Microprocessor based control panel for operation on refrigerant R-407 C complete with 1st charge of refrigerant gas & oil etc. complete all as specified and as directed.
Supply & Fixing of Copper refrigerant Piping for Discharge line from indoor Unit to Outdoor Air Cooled Fan with 5/8" pipe with fitting complete all as specified and as directed.
Supply & Fixing of Copper refrigerant Piping for liquid line from indoor Unit to Outdoor Air Cooled Fan with 7/8" pipe with fitting complete all as specified and as directed..
Supply & charging of Refrigerant Gas R - 407 C in 4 Nos. air cooled Package AC complete with pressure testing and flushing etc. complete all as specified and as directed.
Supply & fixing of 22 Gauge Gl sheet ducting with all fittings such as Tee, bends, tunings, vanes, flange etc., made of Gl sheet of Class - VIII as per IS - 277 fabricated as per IS - 655 including suspesnsion and suporting arrangements including, nut & bolts duly insulated with 13 mm thick aluminium foil faced XPE Foam complete all as specified and as directed.
Supply & fixing of 24 Gauge Gl sheet ducting with all fittings such as Tee, bends, tunings, vanes, flange etc., made of Gl sheet of Class - VIII as per IS - 277 fabricated as per IS - 655 including suspesnsion and suporting arrangements including, nut & bolts duly insulated with 13 mm thick aluminium foil faced XPE Foam complete all as specified and as directed.
Supply and application of duct insulation with 13mm thick closed cell class O Nitrile rubber insulation complete all as specified and as directed.
Supply and application of 10 mm thick open cell nitryle accaustic insulation having density 140 -180 kg/m3 complete all as specified and as directed.
Supply & installiation of control Cabling between indoor & outdoor unit as per required size complete all as specified and as directed.
Supply & Fixing of supply air Grill / diffusers made of aluminium section powder coated with Volume Control dampercomplete all as specified and as directed.
Supply & Fixing of return air Grill / diffusers made of aluminium section powder coated without Volume Control damper complete all as specified and as directed.
Supply & Fixing of Fire damper made of Gl sheet 18 G complete with fuse link complete all as specified and as directed.
Supply & Fixing of fresh air grill with damper made of Gl sheet 18 G complete with bird screen complete all as specified and as directed.
Supply & fixing of volume control damper made of Gl sheet 18 G complete for PAC Units complete all as specified and as directed.
Supply & fixing of Canvas connection made of fire retardent cloth for PAC Units complete all as specified and as directed.
Supply & fixing of fresh air grill with damper made of Gl sheet 18 G complete with bird screen complete all as specified and as directed.
Supply & fixing of volume control damper made of Gl sheet 18 G complete for PAC Units complete all as specified and as directed.
Material & labour for making PCC foundation and platform for PAC Units and MS Stand for Air cooled fan and making wall opening for ducting, piping and cabling etc. includinq making good the disturb surface as per site requirement complete all as specified and as directed.
Supply ,installation ,testing and commissioning step down 11/0.433 KV (at no load ) transformer 3 phase, 4 wire AC, 50 cycles,100 KVA copper wound, outdoor type,EE level-2 with offload manual tap charging arrangement (gear type) on HT side to very secondary voltage up to minus 7.5% for 7 steps @ 3 % including suitable cable entry boxes on both sides to recive HT and LT cable complete in all respect with standared accessories and fitments confirming to IS -1180 latest connection complete all as specified and directed Temperature of oil shall not rise to 35 Degree centigraded to ambient and 40 degree centigrade of winding, Transformer shall be painted with two coated of smoke grey epoxy paint confirming to IS 632. Note:-(a) Transformer shall be oil immersed naturally/self cooled (ONAN) with external cooling tybes/radiator, double wound,copper winding, core type, MS radiator cooled tank complete with first fill of transformer oil of dielectric strength not less than 60 KV as per IS-335 with test certificated and Star BEE level following:-
(i) Rating and diagram plate (ii) Lifting Lugs (iii) Air release vent with plug (iv) Conservator with oil indication (v) Mild steel wheel with oil indication (vi) Silica gel breather assembly with first filling of silica gel (vii) Oil temprtature gauge and washout plug (viii) Complete with under/lover voltage cut off.
Excavation in trenches in soft & loose soil not exceeding 1.5 metre deep and not exceeding 1.5 mtr wide and getting out soil including forming bottom surface to required slope/gradient for laying cables/pipes etc. including removing cable protection PCC covers/ bricks & stacking serviceable covers / bricks for reuse and disposal of unserviceable covers within 50 m complete all as specified and directed by Engineer-in-Charge. Note : (i) Excavation shall be made carefully in order to avoid damage of existing cables and protection covers (ii) The excavation work shall be carried out in short lengths for locating fault in under ground cables at different locations.
All as per item No 30 here-in-before but exc 1.5 deep and n.exc 3 mtr complete all as specified and directed.
Returning, filling in (soils) including spreading, leveling, watering and well ramming in layers of 25 cm thick after the cables etc. are laid, jointed and tested complete all as specified and directed by Engineer-in-Charge.
Removal of surplus excavated spoil (Soils) not exceeding 50 Mtr distance and depositing where directed by Engineer-in-Charge at a level not exceeding 1.5 m above the starting point complete all as specified.
Material & labour for sand filling with clean dry find sand unwashed including gently pun ning around cables in trenches/ducts for cable protection complete all as specified and directed by Engineer-in-Charge. Note. Only punned thickness shall be measured and paid.
Supplying & Laying un-reinforced factory made pre cast flat concrete cable protection cover of class HV, type I, size 300mm x 180mm x 40mm, complete all as specified and directed by the Engineer-in-Charge.
Supply, jointing and testing cable jointing kit of 11 KV (earthed) grade cable for outdoor termination, Heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 Sqmm to 185 Sq mm including taking down old unserviceable cable jointing kit complete all as specified and directed.
Supply, erecting and fixing in true vertical position, steel tubular swaged pole (410 SP – 55), 11 mtr long, complete with cast iron base plate, pole cap / finial taper plug, bolts, nuts and washers, welded reduced section and longitudinal weld throughout entire length of pole with and including 2 coats of black bituminous paint externally upto planting depth and remaining exterior portion of pole finished with one coat of red oxide primer complete all as specified and directed by Engr-in-Charge. Note. Earthwork, PCC work in foundation& coping of pole, Cross arms, danger notice board and anti climbing device shall be measured and paid separately.
Material and labour for fabrication cross arms, bracing, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, driling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat and two under coat of synthetic enamel paint complete all as specified & directed.
Supply, installation and testing 11 KV outdoor type , gang operated Air-break switch triple pole mechanically operated ,mounted on insulator and steel frame with operating mechanism worked from ground level with suitable dia of GI pipe (Med. grade) operating rod of suitable length with an ON-OFF position capacity 200 amps with dropout fuse & 12 insulator connected with new ACSR conductor (jumper) duly Logged incoming and out going with Steel nut bolts and washers complete all as specified & directed.
Material & labour for PCC (1:4:8) type D-1 (using 40 mm graded stone aggregate) for foundation of the pole including necessary form work complete all as specified and directed.
Material & labour for PCC (1:3:6) type C-1 (using 20 mm graded black trap/granite/basalt stone aggregate) for coping of the pole including necessary form work complete all as specified and directed.
Material and labour for earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6mm buried directly in ground vertically to a depth not less than 4.5 meter below normal ground level (with top edge of earth plate not less than 3.75 meter below ground level) connected to GI strip 32 x 6mm main earthing lead by means of galvanized bolts, nuts and washers with connected to earth test point & to main switch board /panel etc. all as specified and testing on completion with and including necessary excavation and earth work in any type of soil, earth electrode, earthing lead from electrode to equipment/substation/panel etc, adequate quantity of charcoal dust and common salt, test point terminal block made out of phoshper bronzein sheet steel box, PCC (1:3:6) type C-1 (using 20mm graded black trap/granite/Basalt stone aggregate) for earth pit with 40 x 40 x 6mm mild steel angle iron frame for cover, pre cast RCC (1:2:4) type B-1 (using 20mm graded black trap/granite/Basalt stone aggregate) 40mm thick cover reinforced with 8mm dia TMT bars 3 Nos both way with 12mm dia round bar handle, GI light grade watering pipe 20 mm dia with funnel and wire mesh, and 40 mm dia GI light grade earth lead protection pipe, complete all as specified and directed.
Supply ,laying, jointing and testing 11 KV (Earthed), aluminium conductor, screened, XLPE insulated, armoured shielded and PVC sheathed cables conforming to IS 7098 (Part-II) amended upto date having cross sectional area 120 Sqmm 3 core complete all as specified and directed by the Engineer-in-Charge. Note :- Earth work, sand cushioning, pipe and PCC cable protection cover shall be measured and paid separately)
Supply, laying, jointing and testing cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 Sq mm 3.5 Core. complete all as specified and directed by Engineer-in-Charge.
Supply and fixing Lightening arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 KA on 11000 volts complete all as specified and directed by Engineer-in-Charge.
Supply and fixing on HT pole danger notice plate for HT 11KV/33KV of size 25 cm x 20 cm , 1.6mm thick mild steel sheet vitreous enameled white with letters, figure and conventional skull & bones “DANGER” etc. in signal red colour and fixed with MS clamps made out of 25mmx3mm MS flat iron, nut, bolts complete all as specified and directed.
Supply, installation, commission ing and testing of LT panel cubical type Outdoor type made out of 16 gauge MS sheet floor mounted vermin and weather proof type factory made conformin g to IP-42 protection and angle iron of size 40x40x6mm covered from all sides and also four Nos legs 45 cm long of angle iron 40x40x6mm with front openable door complete with one coat of powder coated over a one coat of red oxide primer including connecting with single core suitable size of copper wire and copper bus bar of 300 Amp capacity duly installed/ embedded in PCC 1:2:4 block of size 30x30x30cm with colour code tape and totally enclosed in separate chamber. The size of panel board should be able to accommodate and including the following accessories:-
(a) MCCB, 415 volts, 225 Amp rating, 4 Pole fixed for incoming supply with over load short circuit protection with rupturing capacity 25 KA- 01 No (b) MCCB, 415 volt 100 Amp rating three pole, fixed for outgoing supply with over load short circuit protection breaking capacity 16 KA-02 Nos, (c) MCCB 415 volt, 25 Amp rating, 3 Pole fixed for outgoing supply with over load short circuit protection, bracking capacity 10 KA for capacitor bank -01 No (d) MCB TPN 415 volt, 6 Amp rating, 3 phase fixed for outgoing supply, breaking capacity 10 KA -01 No for dozer motor. (e) Supply & fix fully automatic star delta starter 30 HP capacity heavy duty suitable for submersible pumping set, - 01 No (f) Supply & fix starter AC, 3 Phase, 415 volt suitable for compact dozer motor 60 watt capacity, relay range 0.23 to 0.47 Amp - 01 No
(n) Supply and fixing capacitor bank for power factor improvement static condenser type 8 KVAR cap suitable for submersible motor 30 HP, 2900 RPM capacity, Make Crompton Greaves/E PCOS/Mehar/Siemens - 01 No (o) Automatic phase reversal corrector unit of suitable capacity at incoming -01 No (p) Supply & fixing kilowatt hour meter, 3 phase, 415 volt, electronic type CT operated type of suitable capacity at incoming supply -01 No (q) S&F power factor meter 96 sqmm at incoming supply, dynomo meter type, three element three phase, 4 wire balanced and unbalanced load voltage 500 volt with suitable current coil, (a) MCCB, 415 volts, 100 Amp rating, 4 Pole fixed for incoming supply with over load short circuit protection with rupturing capacity 25 KA- 01 No . (b) MCCB, 415 volt 63 Amp rating three pole, fixed for outgoing supply with over load short circuit protection breaking capacity 16 KA-02 Nos
Supply and fixing single pointed air termination copper rod,12 mm dia and 300 mm long complete all as specified and directed
Supply and fixing copper strip 25 mm x 3.15 mm with saddles and fixing screwed for roof conductors and down conductors complete all as specified and directed
Material & labour for Test point terminal block made of gun metal or phosphorous bronze,size 75x75x25 mm;drilled and screwd including 3 Nos 8 mm dia 25 mm long hex head screw complete all as specified and directed
Material & labour for earthing complete with copper earth plate thick electrode of size 600x600x3.15 mm thick burried directly in ground earth pit not less than 2.25 m below ground level connected to copper earth strip of size 20 x 3 mm by means of bolts , nuts ,brass/copper washers, GI pipe 40mm dia light grade 7.5m long,galvanised iron pipe medium grade 20 mm bore for watering and including funnel,wire mesh,RCC 1:2:4 cover slab 50 mm thick with re-inforcement of 8 mm TMT bars@ 100 mm c/c both directions and PCC chamber with 1:3:6 type C2 including excavation and earth work ,disposal of surplus soil to a distance not exeeding 50 mm,charcoal,lugs, common salt complete all as specified and as shown on plate No.3 of SSR part-1.
Material & labour for chemical earthing using outer & inner pipe of copper as earthing electrodes and hydroscopic jelly back fill for good conductivity complete all as directed (Dia of outer pipe shall be 50mm, dia of inner pipe shall be 40mm, length shall be 3 mtrs, thickness of both pipes shall be 2.1 mm and made of minimum 95% copper metal) complete with PCC earth pit and 50mm center to center both ways MS handle 10mm dia made to shape with 50X50X6mm angle iron frame duly painted, earth work in any type of soil connected to earthing test point and testing complete all as specified and as directed all as per Model No. CU-370 Make Om Electrotech or equivelent.
Supply and fixing copper strip 25 mm x 3.15 mm with saddles and fixing screws for roof conductores and down conductors above ground complete all as specified and directed
Material & labour for test point terminal block made of gun metal or phosphorous bronze,size 75x75x25 mm;drilled and screwd including 3 Nos 8 mm dia 25 mm long hex head screw complete all as specified and directed
R D Bansal
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .