GE (Utilities) Udhampur
GE (Utilities) Udhampur Po-Garhi Pin-182121
Provn of treated water at MAP STP to Bde solar plant and various children park at MAP Accn Garhi cantt area and Provn of Air Conditioning (Hot Cold) alongwith accessories for unit OR Dinning Hall and OR institute of SCSR under GE (Utilities) U
2026_MES_747701_1
GE/U-92/2025-26
Open Tender
Miscellaneous Works
Item Rate
120 days
GE (Utilities) Udhampur
AS PER NIT
8 documents required · 8 mandatory
₹500
GE (Utilities) Udhampur
₹92,986
20 Feb 2026
8 Jan 2026
31 Jan 2026
8 Jan 2026
29 Jan 2026
22 Jan 2026
Select, Excess (+), Less (-) Less (-)
Tender Inviting Authority: GE Utilities Udhampur
Name of Work:Provn of treated water at MAP STP to 87 Mtn Bde Solar Plant & various children park at MAP Accn Garhi cantt area and Provn of Air Conditioning (Hot & Cold) alongwith accessories for unit OR Dining Hall and OR institute at 1 Coy and 2 Coy of NCSR under GE (Utilities) Udhampur
Contract No: GE/U-92/2025-26
Ser. No. Item Description Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without Taxes TOTAL AMOUNT TOTAL AMOUNT In Words
Excavation in trenches not exceeding 1.5 mtr wide and not exc. 1.5 mtr in deep in soft/ loose soil getting out and levelling of bottom surface to required level, complete all as specified and directed by Engr-in-Charge. BI01010001010000000000000515BI0100001132 Cum 0.0000 Excess(+) Full Conversion INR 1.01 Supplying, Conveying and fixing spls. Including eart item1 123.223 Nos
Supply, installation, testing and commissioning of CI Butterfly Valve of size 100 mm, conforming to IS 13095, PN-16, wafer type, Disc: SG Iron, lever operated, complete all as specified and directed by Engineer-in-Charge. BI01010001010000000000000515BI0100001142 Each 0.0000 Excess(+) Full Conversion INR 1.02 Construction of chamber for 100mm sluice plates item2 213 Nos
Mounting of header at a height of 1.2 metre above the ground level on PCC pillar of dimension 0.5x0.5x1.8 meter (0.6 meter depth & 1.2 meter height above ground) are as under the followings:- BI01010001010000000000000515BI0100001146 1.02 Construction of chamber for 100mm sluice plates item2 213 Nos
Removing excavated material n. exc. 50m and depositing where directed at a level n. exc. 1.5 m above the starting piont, complete all as specified and directed by Engr-in-Charge. BI01010001010000000000000515BI0100001149 Cum 0.0000 Excess(+) Full Conversion INR 2 Construction of chamber for 100mm sluices valve item3 10 Nos
Note: Protective cover made of MS sheet of thickness not less than 1.60 mm shall be provided over the pumpset, fabricated in dome shape to suit the exact dimensions of the pumpset, ensuring sufficient clearance between the MS sheet and the pumpset for ventilation and maintenance, and to protect the pumpset from rain. The MS cover shall be fixed on the MS angle frame on foundation around pumpset using nuts and bolts. The surface of the MS cover shall be properly cleaned and treated, and painted with one coat of red oxide zinc chromate primer and two coats of approved synthetic enamel paint to prevent corrosion. The cost of providing, fabricating, painting, fixing and all associated works shall be deemed to be included in the quoted rate. BI01010001010000000000000515BI0100001156 1.02 Construction of chamber for 100mm sluice plates item2 213 Nos
Note: Protective cover made of MS sheet of thickness not less than 1.60 mm shall be provided over the pumpset, fabricated in dome shape to suit the exact dimensions of the pumpset, ensuring sufficient clearance between the MS sheet and the pumpset for ventilation and maintenance, and to protect the pumpset from rain. The MS cover shall be fixed on the MS angle frame on foundation around pumpset using nuts and bolts. The surface of the MS cover shall be properly cleaned and treated, and painted with one coat of red oxide zinc chromate primer and two coats of approved synthetic enamel paint to prevent corrosion. The cost of providing, fabricating, painting, fixing and all associated works shall be deemed to be included in the quoted rate. BI01010001010000000000000515BI0100001158 1.02 Construction of chamber for 100mm sluice plates item2 213 Nos
(a) Excavation and earth work for drilling hole for electrode in any type of soil. (b) PCC pit in cement concrete 1:2:4 type B-1. (c) Precast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than 1.87 Kg/Sqm. (d) Funnel with watering pipe of GI 20 mm nominal bore medium grade and copper lugs etc all as specified. (e) 15 mm nominal bore light grade GI protection pipe 7.5 mtr long for protection of earthing lead from mechanical injury or tempering. (f) Requisite quantity of common salt and charcoal. (g) Testing of earthing. Note : On testing after completion of earthing, if the desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk and cost to the entire satisfaction of the Engineer-in-Charge. BI01010001010000000000000515BI0100001161 1.02 Construction of chamber for 100mm sluice plates item2 213 Nos
Description all as per ser item No 22.00 here-in-before but of size 40/32 mm. BI01010001010000000000000515BI0100001165 RM 0.0000 Excess(+) Full Conversion INR 1.02 Construction of chamber for 100mm sluice plates item2 213 Nos
Incoming:- (a) MCCB 4 pole ,Ics=100%Icu- 35/36 KA, 415 Volts, 200 Amps , with thermal adjustable and fixed magnetic setting with extended terminals -01 Nos. (b) On load change over switches 4 pole of capacity 200 Amps -01 Nos. (c) Busbar of electrolytic grade aluminium, 300 Amp rating, 4-pole (R-Y-B-N), of adequate cross-section as per current carrying capacity, mounted and supported on non-hygroscopic, non-carbonising and corrosion-resistant SMC insulators, complete with proper phase colour coding, neutral identification, sleeves/insulation, necessary hardware, and conforming to relevant IS standards - 01 set Outgoing :- (a) MCCB 4 pole ,Ics=100%Icu- 35/36 KA, 415 Volts, 125 Amps , with thermal adjustable and fixed magnetic setting with extended terminals -01 Nos. (b) MCCB 4 pole ,Ics=100%Icu- 35/36 KA, 415 Volts, 63 Amps , with thermal adjustable and fixed magnetic setting with extended terminals -03 Nos. BI01010001010000000000000515BI0100001180 1.02 Construction of chamber for 100mm sluice plates item2 213 Nos
Note:- (i) Rate quoted is deemed to be inclusive of PCC foundation/pedestal and connected earth work. (ii) Panels shall be placed above 0.6 mtr from ground level (iii) Cables shall be terminated using gun metal /SS glands. (iv) Outgoing MCCBs shall be fed with solid busbar connectors and including suitable thimbles/lugs, nut bolts ,washers fitted the cables. BI01010001010000000000000515BI0100001181 1.02 Construction of chamber for 100mm sluice plates item2 213 Nos
(g) Repeatability: ±0.2% of reading (h) Ambient temperature: 0°C to 50°C (i) PTFE lining: up to 125°C max (j) Rubber lining: up to 90°C max (k) Maximum operating pressure: 10 kg/cm² (l) Transmitter enclosure: Die-cast aluminium, protection class IP-66 (m) Flow tube protection: IP-68 (n) Process connection: ASA 150 flanged (o) Electrodes: SS-316L (p) Lining material: PTFE (q) Flanges: Mild Steel (MS) (r) Pipe material: SS-304 (s) Housing material: Mild Steel (MS) Note:- The quoted rate shall be deemed to include all materials, labour, tools, cables, protection conduits, fittings and accessories required for installation, connection and commissioning of the complete flow meter system. BI01010001010000000000000515BI0100001184 1.02 Construction of chamber for 100mm sluice plates item2 213 Nos
Supply and installation of split AC in wall unit air conditioner reversible type indoor and outdoor unit complete with cordless remote control unit and with built in air plasma filter for better indoor air quality of capacity 1.5 TR with standard accessories including MS frame work for installation of outer with side, complete all as specified and directed by Engr-in-Charge. BI01010001010000000000000515BI0100001187 Nos 0.0000 Excess(+) Full Conversion INR 1.02 Construction of chamber for 100mm sluice plates item2 213 Nos
Please Enable Macros to View BoQ information
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.29 MB
BOQ_837314.xls
BOQ • 1.72 MB
TENDER92.pdf
Tender Documents • 1.29 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .