| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.8 LAccepted-AOC 441 G F LIG FLATS PH 2 SEC 14 PKT 3 DWARKA NEW DELHI SECTOR 14 DWARKA DWARKA SOUTH WEST DELHI DELHI 110078 | SOUTH WEST DELHI | DELHI | 110078 | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹27.4 L+₹2.5 L (10.2%)Rejected-Finance RZ A2 2 CHANAKYA PLACE PART I OPP C 1A BLOCK JANAK PURI NEW DELHI 110059 | NEW DELHI | WEST DELHI | DELHI | 110059 | L2 | Rejected-Finance Not Being L1 | |
| 3 | L3₹27.5 L+₹2.6 L (10.3%)Rejected-Finance GROUND FLOOR F 11 PHASE II MAYAPURI WEST DELHI DELHI 110064 | DELHI | WEST DELHI | DELHI | 110064 | L3 | Rejected-Finance Not Being L1 | |
| 4 | L4₹32.4 L+₹7.5 L (30.1%)Rejected-Finance S 170 B 192 VILLAGE JHARERA DELHI SOUTH WEST DELHI DELHI 110010 | NEW DELHI | DELHI | 110010 | L4 | Rejected-Finance Not Being L1 | |
| 5 | L5₹33.5 L+₹8.5 L (34.3%)Rejected-Finance 10 WARD NO 18 PLOT NO 34 KAMDENU FURNTIURE SIKAR RAJASTHAN 332025 | SIKAR | RAJASTHAN | 332025 | L5 | Rejected-Finance Not Being L1 |
| Sl No | Description | Qty | Unit | SANJEEV ENTERPRISES L7 | GLIBS CONSTRUCTION L6 | Ayush Enterprises L4 | RUCHIKA ENGG.WORKS L2 | Ruchi enterprises L5 | OMVIN ENTERPRISES LLP L1 | AMIT ENTERPRISES L3 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down carefully aluminum/copper point wiring (light, fan, socket or power) complete along with fittings such as switches, ceiling roses, pendants, regulators sockets etc, and removing from site and making good disturbed surfaces of walls, floors etc., all as directed. | 355 | Per Point | 5 ₹1,775 | 15 ₹5,325 | 30 ₹10,650 | 3 ₹1,065 Lowest | 4 ₹1,420 | 5 ₹1,775 | 7 ₹2,485 |
| 2.00 | Taking down existing unserviceable MCB DB along with MCBs complete by disconnecting all as directed. | 84 | Each Job | 10 ₹840 | 10 ₹840 | 30 ₹2,520 | 3 ₹252 Lowest | 4 ₹336 | 5 ₹420 | 10 ₹840 |
| 3.00 | Taking down existing unserviceable T/Light fitting . | 120 | Each | 5 ₹600 | 10 ₹1,200 | 30 ₹3,600 | 3 ₹360 | 5 ₹600 | 2 ₹240 Lowest | 10 ₹1,200 |
| 4.00 | Taking down existing unserviceable sub main wiring aluminum/copper cable along with all conduits and fittings all as directed. | 3,550 | RM | 5 ₹17,750 | 10 ₹35,500 | 15 ₹53,250 | 3 ₹10,650 | 2 ₹7,100 | 1 ₹3,550 Lowest | 10 ₹35,500 |
| 5.00M&L for point wiring using approved colour coding as per IS (For phase and neutral), with stranded copper conductor 1.5 Sqmm (nominal area), single core, multistranded, FRLS, PVC insulated and unsheathed cable 1100 volts grade, ISI 694 marked drawn in existing conduits (surface/recessed), terminated in junction box incl 1.5 Sqmm (Nominal area) single core, multistranded, FRLS, PVC insulated and unsheathed cable as earth continuity conductor to common earth and connected to earth dolly complete all as specified for the following :- Note :- 1. Colour code of wiring should be(for phase-Red,neutral-black and earth wire-green) 2. Modular switch sockets fan regulator shall be measured and paid separately under respective items. 3. Cost of Modular MS Box, Modular cover plate an frame of any modules as required at site and as directed by ENgr-in-charge is deemed to be included in the quoted rates. | ||||||||||
| 5.10 | One light point / fan point controlled by one, one way 5 Amps switch | 50 | Per Point | 800 ₹40,000 | 450 ₹22,500 | 680 ₹34,000 | 320 ₹16,000 | 200 ₹10,000 Lowest | 350 ₹17,500 | 250 ₹12,500 |
| 5.20 | One 3 pin socket outlet 5 Amps on independent board | 30 | Per Point | 800 ₹24,000 | 450 ₹13,500 | 680 ₹20,400 | 320 ₹9,600 | 200 ₹6,000 Lowest | 350 ₹10,500 | 250 ₹7,500 |
| 5.30 | One 3 pin socket outlet 5 Amps on same board | 20 | Per Point | 300 ₹6,000 | 80 ₹1,600 Lowest | 680 ₹13,600 | 100 ₹2,000 | 200 ₹4,000 | 300 ₹6,000 | 100 ₹2,000 |
| 6.00M&L for point wiring using approved colour coding as per IS (For phase and neutral), with stranded copper conductor 1.5 Sqmm (nominal area), single core, multistranded, FRLS, PVC insulated and unsheathed cable 1100 volts grade, ISI 694 marked drawn in and including stove enamelled metallic conduit with fittings ISI marked, terminated in junction box incl 1.5 Sqmm (Nominal area) single core, multistranded, FRLS, PVC insulated and unsheathed cable as earth continuity conductor to common earth and connected to earth dolly complete all as specified for the following :- Note :- 1. Colour code of wiring should be(for phase-Red,neutral-black and earth wire-green) 2. Modular switch sockets fan regulator shall be measured and paid separately under respective items. 3. Cost of Modular MS Box, Modular cover plate an frame of any modules as required at site and as directed by ENgr-in-charge is deemed to be included in the quoted rates. | ||||||||||
| 6.10 | One light point / fan point controlled by one, one way 5 Amps switch | 135 | Per Point | 800 ₹1,08,000 | 450 ₹60,750 | 720 ₹97,200 | 320 ₹43,200 | 300 ₹40,500 | 300 ₹40,500 | 250 ₹33,750 Lowest |
Tender Value
₹36.5 L
EMD Value
₹73,000
Closing Date
27 Feb 2026, 6:00 pmClosed
GE E/M RR HOSP DELHI CANTT-10
GE E/M RR HOSP DELHI CANTT-10
REPLACEMENT OF OLD ALUMINIUM SUB MAIN WIRING ALONG WITH OTHER CONNECTED ITEMS IN BASEMENT AND SERVICE CORRIDOR AREA AT AHRR UNDER GE E/M RR HOSP. DELHI CANTT-10
2026_MES_751631_1
GE/H/T-92/2025-26
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE E/M RR HOSP DELHI CANTT-10
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE E/M RR HOSP
₹73,000
Yes
24 Mar 2026
6 Feb 2026
2 Mar 2026
6 Feb 2026
27 Feb 2026
20 Feb 2026
Taking down carefully aluminum/copper point wiring (light, fan, socket or power) complete along with fittings such as switches, ceiling roses, pendants, regulators sockets etc, and removing from site and making good disturbed surfaces of walls, floors etc., all as directed.
Taking down existing unserviceable MCB DB along with MCBs complete by disconnecting all as directed.
Taking down existing unserviceable T/Light fitting .
Taking down existing unserviceable sub main wiring aluminum/copper cable along with all conduits and fittings all as directed.
M&L for point wiring using approved colour coding as per IS (For phase and neutral), with stranded copper conductor 1.5 Sqmm (nominal area), single core, multistranded, FRLS, PVC insulated and unsheathed cable 1100 volts grade, ISI 694 marked drawn in existing conduits (surface/recessed), terminated in junction box incl 1.5 Sqmm (Nominal area) single core, multistranded, FRLS, PVC insulated and unsheathed cable as earth continuity conductor to common earth and connected to earth dolly complete all as specified for the following :- Note :- 1. Colour code of wiring should be(for phase-Red,neutral-black and earth wire-green) 2. Modular switch sockets fan regulator shall be measured and paid separately under respective items. 3. Cost of Modular MS Box, Modular cover plate an frame of any modules as required at site and as directed by ENgr-in-charge is deemed to be included in the quoted rates.
One light point / fan point controlled by one, one way 5 Amps switch
One 3 pin socket outlet 5 Amps on independent board
One 3 pin socket outlet 5 Amps on same board
M&L for point wiring using approved colour coding as per IS (For phase and neutral), with stranded copper conductor 1.5 Sqmm (nominal area), single core, multistranded, FRLS, PVC insulated and unsheathed cable 1100 volts grade, ISI 694 marked drawn in and including stove enamelled metallic conduit with fittings ISI marked, terminated in junction box incl 1.5 Sqmm (Nominal area) single core, multistranded, FRLS, PVC insulated and unsheathed cable as earth continuity conductor to common earth and connected to earth dolly complete all as specified for the following :- Note :- 1. Colour code of wiring should be(for phase-Red,neutral-black and earth wire-green) 2. Modular switch sockets fan regulator shall be measured and paid separately under respective items. 3. Cost of Modular MS Box, Modular cover plate an frame of any modules as required at site and as directed by ENgr-in-charge is deemed to be included in the quoted rates.
One light point / fan point controlled by one, one way 5 Amps switch
One 3 pin socket outlet 5 Amps on independent board
One 3 pin socket outlet 5 Amps on same board
M&L for point wiring using approved colour coding as per IS (For phase and neutral), with stranded copper conductor 2.5 Sqmm (nominal area), single core, multistranded, FRLS, PVC insulated and unsheathed cable 1100 volts grade, ISI 694 marked drawn in existing conduits (surface/recessed), terminated in junction box incl 2.5 Sqmm (Nominal area) single core cable as earth continuity conductor to common earth and connected to earth dolly complete for one power point 15 Amps all as specified. Make of cable : Plaza/Finolex/Havells Note :- 1. Colour code of wiring should be(for phase-Red,neutral-black and earth wire-green) 2. Modular switch sockets fan regulator shall be measured and paid separately under respective items. 3. Cost of Modular MS Box, Modular cover plate an frame of of any modules as required at site and as directed by ENgr-in-charge is deemed to be included in the quoted rates.
M&L for point wiring using approved colour coding as per IS (For phase and neutral), with stranded copper conductor 2.5 Sqmm (nominal area), single core, multistranded, FRLS, PVC insulated and unsheathed cable 1100 volts grade, ISI 694 marked drawn in and including stove enamelled metallic conduit with fittings ISI marked, terminated in junction box incl 2.5 Sqmm (Nominal area) single core cable as earth continuity conductor to common earth and connected to earth dolly complete for one power point 15 Amps all as specified. Make of cable : Plaza/Finolex/Havells Note :- 1. Colour code of wiring should be(for phase-Red,neutral-black and earth wire-green) 2. Modular switch sockets fan regulator shall be measured and paid separately under respective items. 3. Cost of Modular MS Box, Modular cover plate an frame of of any modules as required at site and as directed by ENgr-in-charge is deemed to be included in the quoted rates.
M&L for Sub main wiring/power wiring PVC insulated, armoured, heavy duty electric cable with copper conductor, 1100 Volts grade, cross sectional area 16 sqmm 4 core all as specified and directed by Engr in charge
M&L for Sub main wiring/power wiring complete with four runs of 16.0 Sqmm, single core, PVC insulated, unsheathed FRLS cable, 1100 Volts grade, multistranded with copper conductor, drawn through existing conduits (surface/recessed) , with one run of PVC insulated, 16.0Sqmm FRLS copper conductor for earth continuity all as specified and as directed. NOTE :- Four runs of main copper conductor, one run of copper conductor for earth continuity and one run of conduit shall be measured as one unit length.
M&L for Sub main wiring/power wiring complete with four runs of 16.0 Sqmm, single core, PVC insulated, unsheathed FRLS cable, 1100 Volts grade, multistranded with copper conductor, drawn through and including stove enamelled steel conduit with all fittings as required , with one run of PVC insulated, 16.0Sqmm FRLS copper conductor for earth continuity all as specified and as directed. NOTE :- Four runs of main copper conductor, one run of copper conductor for earth continuity and one run of conduit shall be measured as one unit length.
M&L for Sub main wiring/power wiring PVC insulated, armoured, heavy duty electric cable with copper conductor, 1100 Volts grade, cross sectional area 10 sqmm 3 core all as specified and directed by Engr in charge
M&L for Sub main wiring/power wiring complete with two runs of 6.0 Sqmm, single core, PVC insulated, unsheathed FRLS cable, 1100 Volts grade, multistranded with copper conductor, drawn through existing conduits (surface/recess) , with one run of PVC insulated, 6.0Sqmm FRLS copper conductor for earth continuity all as specified and as directed. NOTE :- Two runs of main copper conductor, one run of copper conductor for earth continuity and one run of conduit shall be measured as one unit length.
M&L for Sub main wiring/power wiring complete with two runs of 6.0 Sqmm, single core, PVC insulated, unsheathed FRLS cable, 1100 Volts grade, multistranded with copper conductor, drawn through and including concealed stove enamelled steel conduit with all fittings as required , with one run of PVC insulated, 6.0Sqmm FRLS copper conductor for earth continuity all as specified and as directed. NOTE :- Two runs of main copper conductor, one run of copper conductor for earth continuity and one run of conduit shall be measured as one unit length.
M&L for Sub main wiring/power wiring complete with two runs of 4.0 Sqmm, single core, PVC insulated, unsheathed FRLS cable, 1100 Volts grade, multistranded with copper conductor, drawn through existing conduits (surface/recess) , with one run of PVC insulated, 4.0Sqmm FRLS copper conductor for earth continuity all as specified and as directed. NOTE :- Two runs of main copper conductor, one run of copper conductor for earth continuity and one run of conduit shall be measured as one unit length.
Supply and Fixing Ceiling rose 3 terminal 5 Amps 230 volts PVC/Polycarbonate, insulated body.
Supply & Fixing 6 Amps 1 way one module switch complete.
Supply & Fixing 6 Amps 3 pin socket two module complete.
Supply & Fixing 16 Amps one way one module switch complete.
Supply & Fixing modular multi socket outlet 6A/16 Amps 3/3 Pin socket 2 module complete.
S&F MCB DB SPN 4 way with 200 Amps rated bus bar with mild steel sheet enclosure, vertical, double door type suitable for fixing MCBs including connecting etc., complete all as specified and as directed.
S&F MCB DB SPN 6 way with 200 Amps rated bus bar with mild steel sheet enclosure, vertical, double door type suitable for fixing MCBs including connecting etc., complete all as specified and as directed.
S&F MCB DB SPN 8 way with 200 Amps rated bus bar with mild steel sheet enclosure, vertical, double door type suitable for fixing MCBs including connecting etc., complete all as specified and as directed.
S & F Vertical Distribution Board iron clad, double door with IP-43 1K-09 protection suitable for MCCB as incommer and MCB SP as outgoing 415 Volts 3 phase 50 C/S 4 way, complete with appropriate size copper bus bar and neutral link confirming to cat pt No 607790 of Legrand or equivalent of make Hager / Merlin Gerin multi-9 complete with one MCCB 3 pole 415 Volts 100 Amps rating with rupturing cap 16 KA of the same make as of distribution board & including cutting chases to wall for fixing DB and making good the disturbed wall surface all as required at site or directed by Engr-in-Charge.
S & F Vertical Distribution Board iron clad, double door with IP-43 1K-09 protection suitable for MCCB as incommer and MCB SP as outgoing 415 Volts 3 phase 50 C/S 8 way, complete with appropriate size copper bus bar and neutral link confirming to cat pt No 607790 of Legrand or equivalent of make Hager / Merlin Gerin multi-9 complete with one MCCB 3 pole 415 Volts 125 Amps rating with rupturing cap 16 KA of the same make as of distribution board & including cutting chases to wall for fixing DB and making good the disturbed wall surface all as required at site or directed by Engr-in-Charge.
S&F MCB SP 6-32 Amps 230 volts 6 KA , B curve ISI all as directed
S&F MCB SP 6-32 Amps 230 volts 6 KA , C curve ISI all as directed
S&F MCB SPN 32 Amps 230 volts , C curve ISI marked all as directed
S&F MCB SPN 25 Amps 230 volts , B curve ISI marked all as directed
S&F MCB TP 63 Amp 415 V 10 KA C curve ISI marked all as directed
S&F MCB TPN 63 Amp 415 V 10 KA C curve ISI marked all as directed
S&F LED Batten industrial type 40 W , 230 Volt, waterproof with IP-65, IK08 protection, robust and durable body made of ABS or Polycarbonate with a frosted or milky polycarbonate diffuser cover, high efficiency SMD LED chipsfor enhanced brightness, integrated high quality driver offering protection against surge voltage, open circuits, short circuits and having high power factor (PF>0.95) and low THD<20%
S&F LED tube light with batten 1X18/20 watts LED, 230Volt energy efficient, industrial batton type, powder coated, CRC Sheet complete with all as accessories internally pre wired and including connecting up with three core twisted flexible copper conductor cable with suitable size Complete all as specified and as directed.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.48 MB
TenderT92.pdf
Tender Documents • 1.17 MB
T92SoC.pdf
Additional Documents • 0.42 MB
BOQ_841825.xls
BOQ • 0.36 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .