Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹1.3 CrAccepted-AOC PROP SUMAN AHMED 10TH BYE LANE DISPUR GUWAHATI KAMRUP M ASSAM | KAMRUP | ASSAM | 781030 | ₹1.3 Cr | 1 | Accepted-AOC As per DBC minutes |
| 2 | 2₹1.4 Cr+₹4.0 L (3.00%)Rejected-AOC | ₹1.4 Cr+₹4.0 L (3.00%) | 2 | Rejected-AOC As per DBC minutes |
Tender Value
₹1.5 Cr
EMD Value
₹3.0 L
Closing Date
13 Jul 2022, 5:00 pmClosed
Director of Agriculture, Assam
Sixmile, Khanapara, Guwahati-22
Construction of Soil Testing Quality Control and Input Testing STQC and IT Laboratory at Diphu District Karbi Anglong
2022_DAASC_26030_1
A/E/4210/ST/Re/Ph-II/19-20/241
Open Tender
Civil Works
Works
270 days
Diphu
Refer as tender Documents
4 documents required · 4 mandatory
₹3,000
₹3.0 L
Yes
Directorate of Agriculture
6 Dec 2022
21 Jun 2022
14 Jul 2022
21 Jun 2022
13 Jul 2022
29 Jun 2022
28 Jun 2022
Amount
Civil Work (Main Building)
Earth work in excavation for foundation trenches of walls, retaining walls, Footing of Columns, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified. Up to a depth of 2.00m. below the existing G.L. Ordinary Soil
Main Building-Total
Extra over item above for each 1m depth or part thereof beyond the initial depth of 2m
Total
Earth / Sand filling with river sand or silt (predominantly non plastic) by truck carriage including loading and unloading in plinth in layer not more than 150 mm thick including necessary, carriage, watering, ramming etc. complete as directed and specified including payment of land compensation, Forest Royalty, Sales Tax and other duties and taxes as may be necessary.Main Building Plinth,Deduction in front area,Left side Near Corridor area
Total
NOMINAL MIX. ( P.C.C. WORKS )
Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footings, tie beams, steps, walls, brick works etc. as directed and specified including dewatering if necessary and curing complete (shuttering where necessary shall be measured and paid separately).In prop. 1 cement : 3 sand : 6 coarse aggregate by volume
Main Building-Total
Providing and laying 25mm thick damp proof course with cement concrete in prop 1:1.5: 3 with graded stone agg. of 10mm down nominal size including providing approved damp proof admixture in proportion as recommended by the manufacturer including curing etc. complete as directed.
Ground Floor-Total
REINFORECED CEMENT CONCRETE WORKS
Providing and laying controlled cement concrete of grade M 20 with 20mm down graded stone aggregate including dewatering if necessary, and curing complete, excluding cost of form work and reinforcement for reinforced concrete work (form work and reinforcement will be measured and paid separately). Using Mixer Machine.In substructure upto plinth level.Foundation, footings, columns with base, tie and plinth beam, grade beam, pile cap, base slab, retaining wall, walls of septic tank, inspection pit and the like and other works not below 100mm thick.M20 grade concrete or prop. 1:1.5:3
(Main building)Total
In super structure. Columns, pillars, posts, struts, suspended floor, roof, landing, shelf and support, balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase including preparing of top surfaces and furnishing and nosing.M20 grade concrete or prop. 1:1.5:3
Main building
PLYBOARD SHUTTERING
Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in::Foundation, footings, bases of columns, pile cap, raft and mass concrete works etc.Using 25mm thick plank
Main building
Sides of tie beams, grade beams etc. at or below ground level.
Columns, Pillars, Posts & Strut
Sides and soffits of beam, beam haunchings, cantilever girders, bressumers, lintel and horizontal ties.Tie beam, beams, lintels.
Total (Main building)
Flat surfaces such as soffits of suspended floors, roofs, landings, cantilever slab, chajjas, balcony and the like Floors etc. upto 200 mm in thicknessSides and soffits of beam, beam haunchings, cantilever girders, bressumers, lintel and horizontal ties.Tie beam, beams, lintels.
Main Building-Total
Staircase with sloping or stepped soffits including risers and stringers but excluding landing .
Main building
BRICK WORK
Providing brick flat soling in foundation and under floor with stone / best quality picked jhama bricks, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials, and if necessary dewatering, complete.Brick on flat soling.
Total (Main building)
Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed. In Sub-structure upto plinth level including dewatering if necessary.In proportion 1:4.
Main Building-Total
1st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paid separately). 115 mm thick brick wall. In cement mortar in proportion 1:4.(1 cement:4 sand).
Main Building-Total
FLOORING
Plain cement concrete floor base in prop1:3:6 laid in alternate bays as specified with coarse agg. of size 13mm to 32mm including dewatering if necessary, and curing etc. complete. (b) 50mm thick
Main Building-Total
Cement concrete works in topping 1:1:2 (1cement :1sand :2 graded aggregates on R.C.C floor, tread and rise of steps finished with a floating coat of neat cement using cement slurry for bond @ 2.75 kg.of cement per sq. m. of floor to be laid in panels including curing complete as directed. b) 15mm thick
Main Building-Total
65 mm thick cement concrete floor consisting of 50 mm under layer of cement concrete in prop. 1:3:6 (1cement : 3 coarse sand : 6 coarse aggregate of 25mm and down) and 15 mm thick wearing layer in cement concrete in prop. 1:1:2 (1cement :1 coarse sand : 2 coarse aggregate of size 10mm down) laid in panels and finished with a floating coat of neat cement finish (using cement slurry for bond @ 2.75 kg. per square metre of floor area) including curing etc. complete as directed.
Ground Floor -Total
Providing VITRIFIED floor tiles of approved quality of specified size, shape and thickness not less than 18mm on floors, skirtings, risers and treads of steps over 15 mm thick base of cement mortar in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf) / white cement slurry mixed with approved pigment to match shade of tiles, mixed with approved pigment to match the shade of the tiles, complete at all levels as specified and directed. (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department)
Executive range-Somany/ Orient/Nitco /Varmora/VITA/ Marbito/ Make Of size 800mmx800mm and above
Total
Providing Antiskid Tiles of approved quality size, shape not less than 8mm on floor, skirting over a cement mortar bed 15mm thick of 1:3 (1 cement: 3 coarse sand) approved make fix with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf)/ white cement complete at all level as specified and directed.CERAMIC.Normal range (Sizes 300 mm x 300mm and above).Orient made: Galaxy Brown, Galaxy creama, Galaxy Pink, Galaxy Green, Pulsar Beige, Pulsar Blue, Pulsar Dove, Pulsar Pink, Burj Brown, Burj Green, Burj Slate
Main Building -Total
Providing polished granite slab of approved quality, size, shape and thickness not less than 18 mm on floors, skirtings, treads and risers of steps over cement mortar bed 15 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile Choksey/Sika/Pedelite/Rouf) /white cement slurry mixed with approved pigment to match the shade of granite slab, complete at all levels as specified and directed. (Cement plastering to be measured and paid separately). (Coloured pigment should be in conformity with colour of slab and as approved and directed by the Department).
Normal Quality.With White cement
Providing polished vitrified wall tiles of approved quality, size, shape and thickness not less than 8mm on walls and skirtings over cement mortar bed 10 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf)/white cement slurry mixed with approved pigment to match shade of tilesc complete at all levels as specified and directed. (coloured pigment should be in conformity with colour of tiles and as approved and directed by the department).
i) Of size 300mmx450mm and above
Main Building-Total
Providing polished SUNROCK-Hi CTS/ MULTIWYN tiles of approved quality, size, shape and thickness not less than 18mm on floors and skirtings over cement mortar bed 10 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey / Sika / Pedelite / Rouf) /white cement slurry mixed with approved pigment to match shade of tiles complete at all levels as specified and directed. (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department).
(a) SUNROCKHi CTS TILES
i). Well, Chocolate, Diamond Square, Ramp, Beach Sand (300x300) mm
CEMENT PLASTERING
15 mm thick Cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed.
On rough side. In cement mortar 1:4. Ground Floor
building-Total
On fair side. In cement mortar 1:4.
building-Total
10 mm thick Cement plaster in single coat on fair side of brick/concrete walls for interior plastering up to 1st floor level including arises or rounded angles not exceeding 80mm girth and finished even and smooth including curing complete as directed.
b) In cement mortar 1:3
Extra over item no 6.2.1 to 6.2.3 for plastering on celling and soffits of stairs up to 1st floor level (instead of plastering on walls) including curing complete as directed.
Main Building-Total
WOOD WORKS
Providing wood work in frame (chowkaths) of doors, windows, clerestory windows
(b) With Ist Class timber ( Bonsum/Sundi)
Providing, fitting and fixing factory made exterior type fully panelled single leaf door shutters of approved brand conforming to relevent I.S code having kiln seasoned and vacuum pressure treated Hollock / Bonsum / Sundi rail and styles with pannel of Anchor brand 12mm thick veneered Teak wood particle board bonded with phenol - formaldehyde synthetic resin adhesive conforming to relevent I.S code including 4 nos of oxidised iron butt hinges (100mm x75 mm x3.55mm) to each leaf complete.
(i) 40mm thick
GRILLS
Supplying, fitting and fixing anodised aluminium decorated grill with anodised aluminium rectangular frame of 'F' and 'H' section fitted with walls, columns or stiffeners by special type of screws as per specification by the Department for all levels. (Aluminium Alloy procured from primary aluminium producer (On submission of certificate of alloy purchaging from primary producer)
Ground Floor,first floor-Total
ALUMINIUM WINDOWS
Providing, fitting and fixing anodised aluminium sliding windows and ventilators of standard sections of approved brand without horizontal glazing bars, joints mitred and welded (manufactured to relevant IS specifications) and providing and fixing handles, angle cleat, rubber gasket, roller, bolting device, locking arrangements, screws etc as required complete as specified and directed for all levels.
2 track sliding windows.5 mm clear glass
main building -Total
5 mm frosted glass
Ground Floor,first floor-Total
3 track sliding windows.6mm clear glass
Ground Floor,first floor-Total
ALUMINIUM PARTITION
Providing, fitting and fixing anodised aluminium partition walls of standard sections of approved brand, joints mitred and welded (manufactured to relevant I.S. specification) and providing and fitting angle cleat, rubber gasket, bolting device screws etc. at all levels.
Prelaminated Board
Ground Floor,first floor-Total
Providing, fitting and fixing anodised aluminium framed glazed doors with partition walls partly glass and partly prelaminated board with anodised aluminium frame made of 100mm x 43mm x 2mm sections of approved brand with doors style of size 81mm x 43mm x 2mm, top rails 46mm x 43mm x 2mm, lock rails 81mm x 43mm x 2mm, fitting with glazing clip, special rubber type gusket complete including hydraulic floor spring pivot aluminium door handle lock angles cleat etc. complete as directed by the department at all levels.
6mm thick glass panes and 12mm prelaminated board.Ground Floor,first floor-Total
P.V.C. DOORS & DOOR FRAMES
Providing, fitting and fixing 40 mm x 48 mm wood reinforced PVC chowkhats fixed to the columns / stiffeners / walls with necessary holdfast / sleeves etc. as specified and directed at all levels.
Ground Floor,first floor-Total
Providing, fitting and fixing 24 mm / 29 mm thick polymer reinforced moulded PVC door shutters fixed to the chowkath with necessary hinges, screws, bolts etc. as specified and directed at all levels (Door fixtures and fittings to be measured and paid seperately).
29 mm thick. Ground Floor,first floor-Total
PAINTING
Providing two coats of Birla White Wall Care Putty (Water Resistant White Cement based putty for concrete/ mortar walls and ceiling both internal and external) after removing all loosely adhering material from the wall surface with the help of emery stone, putty blade or wire brush and moistening the wall with sufficient quantity of clean water as specified and directed by the department. (Total thickness of two coats is maximum 1.5mm)
Thickness = 1.5 mm thick
Wall painting (two coats) with Plastic emulsion paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) on new surface to give an even shade after throughly brushing the surfaces free from mortar droppings and other foreign matter and sand papered smooth.
Applying priming coat with ready mixed paint, wood primer (pink) over new wood based surfaces over 100mm in girth/ width after and including preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter, sand papering and knotting.
With ready mixed paint, wood primer (pink)
Painting two coats surfaces over 100mm in width or grith (excluding priming coat) on new wood and wood based surfaces with enamel paint of approved brand and manufacture (Asian paint/Berger paint/ICI paint/J& N paint/Nerolac paint) to give an even shade including cleaning the surfaces of dirt, dust and other foreign matter sand papering and stopping.
Surface over 100mm in width or girth. High gloss (Asian paint/ Berger paint/ ICI paint/ J& N paint/ Nerolac)
Applying primary coat with ready mixed "red -lead /red-oxide" primer over new steel and other metal surface up to 100mm in width or girth after preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and scoured with wire brushes, fine steels, wood scrapers and sand paper.
With ready mixed 'red-lead/ red oxide' primer
Painting two coats Surfaces over 100mm in width or grith (excluding priming coat) on new steel and other metal surface with enamel paint of approved brand and manufacture (Asian paint/Berger paint/ICI paint/J& N paint/Nerolac paint) to give an even shade including cleaning the surfaces of dirt, dust and other foreign matter. .
Surface over 100mm in width or girth.High gloss (Asian paint/ Berger paint/ ICI paint/ J& N paint/ Nerolac
Supplying, fitting, fixing and painting where necessary (one coat primer and two coats of paint) M/ F suspended ceiling which includes G.I. perimeter channels of size 0.55mm thick…etc.
DOOR FITTINGS
Supplying, fitting, fixing anodised aluminium fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete.( anodised to bright natural matt & satin finished )
Sliding door bolts.250mm x16mm sliding door bolt.
Tower bolt
300mm x 12mm tower bolt.
M) Motor lock Vertical Typ
V) ii) 75mm (Godrej with handle(4 Lever)
REINFORCEMENT
Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level) From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL.Super Ductile (SD) TMT reinforcement bars
DOOR FRAMES
Providing and fixing stainless steel (Grade-304) railing made of Hollow tubes,channels,plates etc. including welding,grinding,buffing,polishing and making curvature(wherever required) and fitting the same with necessary stainless steel bolts and nuts complete i.e fixing the railing with necessary accessories and stainless steel dash fasteners, stainless steel bolts etc. of required size,on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer- in- charge (For payment,only weight of stainless steel member is to be considered .No extra payment for fixing accessories such as nuts,bolts,fasteners etc. will be considered)
Providing and fixing in position collapsible M.S. shutters with vertical channels 20mmx10mmx2mm braced with flat iron diagonals 20mmx5mm size with top and bottom rails of T-iron 40mmx40mmx6mm with 38mm dia steel pulleys complete with bolts and nuts, locking arrangements, stoppers, handles including applying a priming coat of red lead paint.
PLINTH PROTECTION WORKS AND PERIPHERY DRAINS
Providing plinth protection with bricks flat laid in cement mortar 1: 4 and finished with 15mm thick cement plaster in prop. 1:2 with a floating coat of neat cement finish.
Providing drain with brick work in cement mortar in proportion 1:5 with half brick thick side walls and 100mm thick C.C (1:3:6) base over one brick flat soling including 15mm thick cement plastering in prop. 1:3 finished with a floating coat of cement slurry as directed with necessary shttering for sides and earth work in excavation of foundation trenches and refilling the sides after completion of work etc. as specified. 300mm wide and average 250mm deep with bed slope 1 in 150 with initial depth of 100mm.
ANTI TERMITE TREATMENT
Pre construction anti-termite treatment at the bottom of foundation pits and walls on either side up to a height of 300 mm from the the bottom of the excavation made for column, plinth beam, wall trenches etc by applying the emulsion @ 5 litres per square meter of the surface area before starting construction work (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete. With aqueous emulsion having concentration 1:19 with chloropirophose solution and water i.e. 1% solution. Total
FIRE EXTINGUISHER
Supply, Installation, Fixing of DRY CHEMICAL POWDER Fire Extinguisher confirming to IS: 2171 with ISI mark and CO2 cartridge will be confirming to IS: 4947 with ISI mark, Powder will be confirming to IS: 4308 with ISI Mark (10 kg) BRAND : FIRESTOP / FIREND / FIRE SHIELD
Supply, Installation, Fixing of ABC Stored Pressure Fire Extinguisher with built – In pressure Gauge to know the Ready ness of the Extinguisher Squeeze Grip Handle As per IS:13849 with ISI mark (05 kg capacity) BRAND : FIRESTOP / FIREND / FIRE SHIELD
BIO-DIGESTER(Septic tank)
Earth work in excavation for foundation trenches of walls, retaining walls, Footing of Columns, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified. Up to a depth of 2.00m. below the existing G.L. Ordinary Soil
NOMINAL MIX. ( P.C.C. WORKS )
Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footings, tie beams, steps, walls, brick works etc. as directed and specified including dewatering if necessary and curing complete (shuttering where necessary shall be measured and paid separately).In prop. 1 cement : 3 sand : 6 coarse aggregate by volume
Providing and laying controlled cement concrete of grade M 20 with 20mm down graded stone aggregate including dewatering if necessary, and curing complete, excluding cost of form work and reinforcement for reinforced concrete work (form work and reinforcement will be measured and paid separately). Using Mixer Machine.In substructure upto plinth level.Foundation, footings, columns with base, tie and plinth beam, grade beam, pile cap, base slab, retaining wall, walls of septic tank, inspection pit and the like and other works not below 100mm thick.M20 grade concrete or prop. 1:1.5:3
In Super structure from plinth level upto Ist Floor Level. Vertical Wall, In Prop : M20 Grade of concrete 1: 1.5:3
ii) Columns, pillars, posts, struts, suspended floor, roof, landing, shelf and support, balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase (except spiral staircase and landing ) including preparing the top surface and finishing of nosing. N) Without using admixture, plasticiser b) M20 grade concrete or Prop. 1:1.5:3
PLYBOARD SHUTTERING
Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in::Foundation, footings, bases of columns, pile cap, raft and mass concrete works etc.Using 25mm thick plank Columns, Pillars, Posts & Strut
Flat surfaces such as soffits of suspended floors, roofs, landings, cantilever slab, chajjas, balcony and the like Floors etc. upto 200 mm in thickness
Vertical surface such as walls (any thickness), parapet walls, partitions and the like including attached pilasters, butresses, plinth and string courses and the like.
Providing brick flat soling in foundation and under floor with stone / best quality picked jhama bricks, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials, and if necessary dewatering, complete.Brick on flat soling.
65 mm thick cement concrete floor consisting of 50 mm under layer of cement concrete in prop. 1:3:6 (1cement : 3 coarse sand : 6 coarse aggregate of 25mm and down) and 15 mm thick wearing layer in cement concrete in prop. 1:1:2 (1cement :1 coarse sand : 2 coarse aggregate of size 10mm down) laid in panels and finished with a floating coat of neat cement finish (using cement slurry for bond @ 2.75 kg. per square metre of floor area) including curing etc. complete as directed.
CEMENT PLASTERING
10 mm thick Cement plaster in single coat on fair side of brick/concrete walls for interior plastering up to 1st floor level including arises or rounded angles not exceeding 80mm girth and finished even and smooth including curing complete as directed. b) In cement mortar 1:4
Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level) a) From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL (ii)Super Ductile (SD) TMT reinforcement bars
NON SHEDULE ITEM
Alumunium Rod
Aluminium hanger
Nylon matrices
Alumunium binder
Bacteria
PVC Pipe fittings
Sanitary and Water Supply Works
EUROPEAN TYPE WATER CLOSET
Providing fitting and fixing vitreous China pedestal type water closet (European type WC pan 400 mm high) with seat and lead, CP brass hinges and rubber buffers, CI / MS brackets, 40 mm diameter flush band withfittings including painting of fittings and brackets, required. Parryware make.White (i) Universal Closet S trap
PVC FLUSHING CISTERN
Supplying, fiting and fixing PVC flushing cistern with all internal fittings with CI brackets including fitting and fixing standard size CP flush pipe, union clamps etc. Paryware make.White. Economy single flush
URINAL
Providing fitting and fixing vitreous China flat back type lipped front urinal basin with standard flush pipe and CP brass spreader andbrass unions, etc. complete including painting of fittings and brackets, cutting and making good the walls and floors wherever required. c) Jaquar make.White. Urinal (Cat.No.URS-WHIT-0704) With Sensor (Cat No. SNR-CHR51097)
Supplying fiting and fixing vitreous china division plate including fitting and fixing compete as directed and specified. (ii) Hindware Make (a) White (i) Division Plate 680 x 300 (Cat. No.61001)
WASH BASIN
Providing vitreous China wash basin with CI / MS brackets, CP brass chain with plug, PVC waste pipe including painting of fittings and brackets, cutting and making good the walls wherever required. (Pillar cock, stop cocks, waste coupling are to be paid separately). BASIN (without pedestal), Parryware Make. Tapti Basin 500 x 360 (Cat No.C0424/410).
MIRROR
Providing fitting and fixing Mirror with plastic frame of size 500 x 400mm complete as directed and specified.
SOAP TRAY,SOAP DISH,LIQUID SOAP DISPENSER AND LIQUID SOAP CONTAINER
Providing, fitting and fixing CP soap tray / soap dish complete as directed and specified. (i) Jaquar Make (a) Continental (Cat.No.ACN-1331N)
TOWEL RAIL,TOWEL RACK & TOWEL RING
Providing, fitting and fixing CP towel rail complete as directed and specified. Jaquar make (i) continental towel ring square cat no.ACN-1121
WASTE COUPLING
Providing, fitting and fixing Chrome Plated waste coupling complete as directed and specified. b) sona(i) Rupa 32mm (HT/FT)(Cat No.WS-0801)
Providing, fitting and fixing Chrome Plated bottle trap pipe complete as directed and specified. (a) Sona make (i) Pipe for bottle trap 300mm long (Cat. No.BT-0761)
PVC PIPES, BENDS, JUNCTIONS, TEES ETC.
Supplying, fitting and fixing PVC pipes of 6 Kg/cm2 (Supreme/Prince) or other ISI approved including joining ,fitting and fixing wiyh clamps etc.as necessary complete at all levels including below G.L as directed and specified. a) In exposed surfaces or in trenches. (ii) 110mm dia.
Supplying fiting and fixing 87.5 degree PVC bend with door of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. a) In exposed surfaces or in trenches. (ii) 100mm dia
Supplying fiting and fixing PVC single tee with door of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. a) In exposed surfaces or in trenches. (ii) 110mm dia
Providing fitting and fixing PVC cowel of ISI make complete as directed and specified. (ii) 110mm dia. PVC cowel of ISI make
Supplying, fitting and fixing Chrome Plated (C.P.) basin mixer complete as directed. Lauret Make a) Central hole basin mixer Cat No. 1210 for wash basin
GRATING
C.P. Grating. 110 mm dia
Construction of inspection pit inside measurement 450mm x450mm x450mm .. Etc excavation of pit as directed.
Supplying including fitting fixing of following A.C. Exhaust fan in the existing hole on the wall of following sweeps with making necessary connection as approved by the Deptt.)as required complete and as directed by the Department. High Speed 225 mm sweep (ORIENT make), Trans Air 225 mm sweep (Crompton make), Ventil Air DX 250 mm sweep Louver type (Havells make)
Renewing laboratory sink of Parryware make with PVC waste pipe etc. complete including painting the fittings ,cutting &making good the walls wherever required. (Sink cock, stop cocks, waste coupling are to be paid separately. (b) coloured (ii) Size 450 x 300 x 180 (Cat.No.50001)
Piping
Providing & fixing CPVC Pipes having thermal stability for hot and cold water supply:-
(A)) Exposed or in trenches
a) 15 mm nominal outer dia pipe
d) 32 mm nominal outer dia pipe
e) 40 mm nominal outer dia pipe
(B) Concealed pipe with cutting chases & making good the walls
a) 15 mm nominal outer dia pipe
b) 20 mm nominal outer dia pipe
BIB COCK
Supplying fitting and fixing CP bib cock 15 mm diametre of approved brand directed and specified. (GI and CP pipes will be measured separately).Jaquare make.Continental /Clarion Agmeco brand (v) Bib Cock Two way with Flange CAT No.CC 00203/CAT No.CN 00203
STOP COCK
Supplying fitting and fixing stop-cock of approved brand of size as mentioned below and directed and specified.
Agmeco Brand
(a) 15mm dia(Male/ Female )
(b)15mm dia(Concealed )
Supplying and fitting fixing C.P. pillar cock of 15mm dia of approved brand as specified and directed. Agmeco (classic) (b) Round
Supplying and fitting gun metal country pit valve (full way valve) I.S.I. Make as specified and directed.
a) 50mm dia
c) 25 mm dia.
Supplying fitting and fixing G.I. Pipes of following sizes, with all necessary 'R' brand or similar approved G.I. Fittings such as bend, tee, elbow, reducer, nipple, plug, long screw fitting, H.W. clamps etc.complete at all levels including below G.L. as directed and specified.
(A) Exposed on walls b) 40 mm dia (Medium) i) Using Tata make
f) 15 mm dia (Medium) i) Using Tata make
(II) Concealed by chieselling or breaking brick wall/ C.C. wall/ R.C.C. wall and making good to the damaged structure. f) 15 mm dia (Medium) i) Using Tata make
Supplying and placing plastic cylindrical vertical claused top (PCVC) tank of Sintex / Polycon / Patton make over the stagging with manhole cover with locking and cleaning arrangement including providing pads of size as required for inlet and outlet pipe 2000 Lt capacity (a) Sintex make
Supplying fitting and fixing iron removal filter filling with treated sand, pebbles, manganishdioxide and other required materials of various filtration rate per hour of DOLPHIN make with all necessary fittings such as valve,bib cock,pipe connection etc.with a free maintanance period of six monthhs (A) With Zoloto fittings (III) 5000 liters capacity (a) 6 mm thick Vessel FRP
INTERNAL ELECTRICAL WORKS MAIN LABORATORY BUILDING
SCHEDULE ITEMS
Supply and laying of following size Power/Control Copper cables, Solid Copper conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Unarmoured/Armour (Galvanised for cables up to 10 x 1.5 sq mm.8 x 2.5 sq mm.2 x 10 sq mm.3 x 10 sq mm.4 x 6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 Sheathed, 650/1100 V grade as per IS 7098 (Part 1) 1988, U.G. cable laid in ground/partially in air (as required for termination over ground including excavation of cable trench up to depth of 75cm, refilling, protective brick covering, Sand cushioning etc complete handling of surplus spoil, debris et to proper place as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make) . 3 core A2XWY A2XFY 10.00 Sq.mm 3 Core armoured U.G. cable
Supplying including installation, commissioning of vermin and dust proof totally enclosed, Phosphatised Powder Painted cubical indoor type floor/wall mounting compartmentalize panel board of size 1.25M X0.7MX 0.40M made of 16 SWG1.66 m thick C.R. sheet and 35mm X 35mm X 5mm size angle having 4 no legs at the bottom. The panel board is to be erected in 1 : 3 : 6 PCC foundation including brick soling / grouting etc. complete neatly Wiring done with provision for one no 250A 4pole 415V MCCB or Switch Fuse Unit as incomer and provision for 2nos DP or TPN out going as specified and directed by the deptt. confirming to IP 43 protection comprising of the following electrical items:
Wiring to 5 a pin 6 Amps plug point with 1.5 sq. mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed 2 mm thick/ heavy rigid ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system including 5 pin 6 Amps flush type plug socket and 6 Amps F/T switch (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.), GI/ MS switch board (I.S.I. mark with phenolic laminated sheet cover including earth continuity with 1.5 sq. mm. cable to third pin of the plug socket etc. as required complete, when placed elsewhere.
Short point up to 3.00 metre. length.
Wiring for Circuit Wiring with 2 x 1.5 sq. mm. cable in 20 mm dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including earth continuity in surface/ recessed 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit wiring system.
With 2 x 4 sq. mm. + earth continuity with 1x2.5 sq. mm. cable in 20 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
With 2 x 6 sq. mm. + earth continuity with 1x 4 sq. mm. cable in 25 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
With 2 x 10 sq. mm. + earth continuity with 1x 6 sq. mm. cable in 25 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
Supplying and fixing of bulk head fitting suitable for CFL lamp complete with all accessories including 20 watts CFL lamp and connection as approved by the Deptt.)as required.
Supply, installation & testing of Copper Plate earth station with 600 mmx600 mmx3 mm copper earth plate with necessary 40 mm dia. G.I. medium duty watering pipe with G.I. Fittings such as Socket, Tee, elbow, nipple and 50 mmx40 mm G.I. reducing socket for funnel including locking arrangement with 300 mmx300 mmx6 mm C.I. hinged cover plate complete with digging of earth pit, construction of brick chamber and plastering of both inner & outer surface of wall as specified and directed by the deptt .
Supplying & laying of 8 SWG Copper. earth from Earth Electrode (below G.L.) to electrical switch gears or electrical machineries including making necessary connection as approved, specified and directed by the deptt.
Wiring for light point with 2x1.5 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor … etc as directed.
Short point up to 3.00 metre. length.
Medium point up to 6.00 metre. Length.
Long point up to 10.00 metre. Length.
Wiring for Fan point with 2x1.5 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor … etc as directed. Medium point up to 6.00 metre. Length.
Wiring for Call Bell point with 2x1.5 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor … etc as directed. Long point up to 10.00 metre. Length.
Wiring for 5/6 pin 16 Amps power plug point with 4 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system including earth continuity with 2.5 sq. mm cable to the 3rd pin of the socket as required complete with 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) Medium point up to 6.00 metre. Length.
Supplying and fixing of polished Brass Bracket of 18 S.W.G, 25 cm long cast back plate and brass lamp holder complete including connection as approved by the Deptt.)as required Without Lamp
Supplying including fitting and fixing of electronic resistance type regulator for ceiling fan complete with all connection etc.
Supplying fixing I.C.T.P and N link Main Switch with rewire able fuses of 500 Volt grade( HPL/ GECO / ANCHOR or equivalent make) including drilling boards/iron frames and fixing with bolts and nuts and connection as approved by the Deptt.)complete as required 30/32 Amps Capacity T.P. N
Providing and fixing IC distribution fuse board with re-wireable fuses of 250 Volts grade 15 Amps per way including fixing to the board and connection etc. 3 - way capacity
Installation, testing and commissioning of pre-cabled fluorescent fitting of all types, complete with all accessories and tubes etc. directly on ceiling/wall including connection as approved by the Deptt.)with 1.5 sq mm PVC insulated copper cables as required.
Supplying with fitting and fixing sheet steel, phosphatised, powder painted Single door surface mounting MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. Schneider neo break, C&S, Havells, INDOASIAN, HPL or equivalent as approved by the Deptt.)make) 6 way SPN single door
EXTERNAL ELECTRICAL WORKS MAIN LABORATORY BUILDING
Supplying & laying of 8 SWG Copper. earth from Earth Electrode (below G.L.) to electrical switch gears or electrical machineries including making necessary connection as approved, specified and directed by the deptt.
Transformer
Supplying, installation testing and commissioning of the following rating copper wound indoor / out door type transformer complete including the payment to be made to power supply authority for supervision charge, labour charge, cost of L.T/H.T metering etc. (excluding the cost of load security) and making necessary arrangement for charging approval of the sub-station from the competent authority as directed and specified by the department. Transformer should be as per CEA guidelines as ammended up to date upto 200 KVA star rating up to 5 star, above 200KVA as per CEA guidelines for losses along with LV enclosure. 63 KVA,50Hz.11/0.433 KV. Oil filled transformer with Off Circuit tap change.
Supplying and fitting fixing of H.T. danger plate complete as required and as directed by the department.
Supplying including installation, testing and commissioning of Water Cooled Jackson Diesel Generator set coupled to suitable alternator of 415 V, AC, 3-Phase 0.8 p.f.(la mounted on a 1) M.S. Fabricated base frame.,2) M.S. fuel tank of required capacity.,3) Residual Silencer.,4) AMF/Standard Control Panel.5) Suitable batteries with lead.,5) First fill of lube oil.,6) Acoustic Enclosure complete with all accessories as specified and directed by the department conforming to IS comprising the following Technical Specification.. (RANGE FROM 15 KVA TO 625 KV
TECHNICAL DATA CJ25D5P GENERATOR SET SPECIFICATIONS 25/20 3. No. of Phases. 1 phase. 4. POWER FACTOR 0.8 LAG JACKSON ENGINE SPECIFICATION. 1. make). Cummins 2. Model. X 2.5 G2 3. No. of Cylinders. 3 4. Aspiration. Natural 5. Cooling. Water Cooled. 6. Governor. Mechanical 7. Battery Capacity Rating. 12 Volt. 8. FUEL CONSUMPTION LTR/HR @ 75% LOAD 4.8 ALTERNATOR SPECIFICATION. 1. make). CGT (STAMFOR 2. Voltage Regulation. +/- 1.0% 3. Insulation. Class - H. 4. Standard Enclosure. IP 23 5. No. of Phases. 3 AND 1
WITH SRANDARD CONTROL PANEL
MAIN ENTRANCE GATE
EARTH WORK Earthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified.(a) In Ordinary Soil. Upto 2.00m Depth.
NOMINAL MIX. ( P.C.C. WORKS )
Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footings, tie beams, steps, walls, brick works etc. as directed and specified including dewatering if necessary and curing complete (shuttering where necessary shall be measured and paid separately). In prop. 1 cement : 3 sand : 6 coarse aggregate by volume
REINFORECED CEMENT CONCRETE WORKS
Providing and laying controlled cement concrete of grade M 20 with 20mm down graded stone aggregate including dewatering if necessary, and curing complete, excluding cost of form work and reinforcement for reinforced concrete work (form work and reinforcement will be measured and paid separately). In substructure upto plinth level Foundation, footings, columns with base, tie and plinth beam, grade beam, pile cap, base slab, retaining wall, walls of septic tank, inspection pit and the like and other works not below 100mm thick. in prop: 1:1.5:3
In super structure Columns, pillars, posts, struts, suspended floor, roof, landing, shelf and support, balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase including preparing of top surfaces and furnishing and nosing. (b) in prop: 1:1.5:3
PLY BOARD FORMWORK
Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in:
Foundation, footings, bases of columns, pile cap, raft and mass concrete works etc. (b) Using 25mm thick Plank.
Sides of tie beams, grade beams etc. at or below ground level. (b) Using 25mm thick plank
Columns, pillars, posts, & struts of square/ rectangular/ polygonal in plan or any shape like Tee/L etc. having plane vertical face.
Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level) a) From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL b) Other ISI approved TMT reinforcement bar (SAI/BISCON/THERMAX) (For Assam Type Bldg., drain works,,retaining wall&boundary wall etc. .
Providing, fitting and fixing M.S. grill of required pattern for windows/ clerestory windows/ openingwith M.S. flats at required spacing in frame all round, squre or round M.S. bars with round headed bolts and nuts or screws. II Ornamental grill (c) Fixed to Brickwork/P.C.C/R.C.C.
PLASTERING
20 mm thick Cement plaster in two coats on single or half brick walls for interior plastering up to 1st floor level including arises, internal rounded angles,chamfers and / or rounded angles not exceeding 80mm in girth and finished even and smooth including curing complete as directed. B) On fair side a) In cement mortar 1:3
PAINTING
Applying one coat of cement primer of approved brand and manufacture on new wall surface after throughly brooming the surfaces free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth.
Finishing old/new wall with water proofing weather coat smooth anti-fungal exterior painting of approved make of Dulux (ICI) paint of required shade after cleaning and clearing the surface etc. including scaffolding complete as directed at all levels (two coats)
Applying primary coat over new steel and other metal surface over 100m in width or girth after preparing the surface by throughly cleaning oil,grease, dirt and other foreign matter and scoured with wire brushes, fine steels, wood scrapers and sand paper. a). With ready mixed "red-lead/ red oxide" primer.
Painting two coats (excluding priming coat) on new steel and other metal surface with enamel paint of approved brand and manufacture(Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surface of all dirt, dust and other foreign matter. (i).Surfaces over 100mm in width or girth. b). High gloss (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac).
PARKING ENTRANCE GATE
Earthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified.(a) In Ordinary Soil. Upto 2.00m Depth.
Providing soling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete. (a).Brick on flat soling.
Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately). (a) In prop 1cement: 3 sand :6 coarse aggregate by volume
Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level) a) From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL (i) TMT Corrosion resistant steel (CRS) reiforcement bar
FORM WORK
Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in: Foundation, footings, bases of columns, pile cap, raft and mass concrete works etc. b) Using 25mm thick Plank.
Sides of tie beams, grade beams etc. at or below ground level. (a) Using 38mm thick plank (b) Using 25mm thick plank
Columns, Pillars, Posts & Strut (a) Square, Rectangular, polygonal in plan or any shape like Tee/L etc. having plane vertical face (ii) Using 25mm thick plank
REINFORECED CEMENT CONCRETE WORKS
Providing and laying controlled cement concrete of grade M 20 with 20mm down graded stone aggregate including dewatering if necessary, and curing complete, excluding cost of form work and reinforcement for reinforced concrete work (form work and reinforcement will be measured and paid separately). In substructure upto plinth level Foundation, footings, columns with base, tie and plinth beam, grade beam, pile cap, base slab, retaining wall, walls of septic tank, inspection pit and the like and other works not below 100mm thick. in prop: 1:1.5:3
In super structure Columns, pillars, posts, struts, suspended floor, roof, landing, shelf and support, balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase including preparing of top surfaces and furnishing and nosing. (b) in prop: 1:1.5:3
Supplying, fitting and fixing double leaf heavy duty iron gate, frame made from 50mm x 6mm M.S. flat iron with another horizontal flat at the middle, 20mm dia M.S bars at 200mm apart from bottom flat to top flat and 20 mm dia M.S. bars at 200mm apart from bottom flat to middle flat including drilling, welding etc. complete. All vertical bars are to be protruded at least 100mm above the middle and top flat is to be flattended and pointed as directed. Necessary locking arrangement on both faces, arrangement for temporary closing the gate and 2 nos.( minium) strong iron hinges of M.S bars and flat of same sizes on each leaf to be embeded in C.C brick pillars as necessary including a red oxide painting to all iron works as directed and specified. (Separate payment will be made for posts).
WASTE DISPOSAL AREA
Earthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified.(a) In Ordinary Soil. Upto 2.00m Depth.
Providing soling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete. (a).Brick on flat soling.
Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately). (a) In prop 1cement: 3 sand :6 coarse aggregate by volume
Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level) a) From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL (i) TMT Corrosion resistant steel (CRS) reiforcement bar
Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in:
Foundation, footings, bases of columns, pile cap, raft and mass concrete works etc. b) Using 25mm thick Plank.
Sides of tie beams, grade beams etc. at or below ground level.
(b) Using 25mm thick plank
Columns, Pillars, Posts & Strut
(a) Square, Rectangular, polygonal in plan or any shape like Tee/L etc. having plane vertical face
(ii) Using 25mm thick plank
REINFORECED CEMENT CONCRETE WORKS
Providing and laying controlled cement concrete of grade M 20 with 20mm down graded stone aggregate including dewatering if necessary, and curing complete, excluding cost of form work and reinforcement for reinforced concrete work (form work and reinforcement will be measured and paid separately). In substructure upto plinth level Foundation, footings, columns with base, tie and plinth beam, grade beam, pile cap, base slab, retaining wall, walls of septic tank, inspection pit and the like and other works not below 100mm thick. in prop: 1:1.5:3
In super structure Columns, pillars, posts, struts, suspended floor, roof, landing, shelf and support, balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase including preparing of top surfaces and furnishing and nosing. (b) in prop: 1:1.5:3
1st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paid separately) (A) 112mm thick brick wall (a) In cement mortar in proportion 1:4. (1 cement:4 sand)
15 mm thick Cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed. B) On fair side b) In cement mortar 1:4
15 mm thick Cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed. A) On rough side b) In cement mortar 1:4
Cement plaster skirting with cement mortar in prop. 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement including rounding of junctions with floor. (a) 15 mm thick
DISMENTALLING OF ASSAM TYPE BUILDING
Demolishing CC floors of various thickness including top layer and base course and disposal of debris as directed for all levels.
Dismantling all types of ceiling, partition and wall lining and stacking the materials as directed by the department for all levels
Dismantling all types of corrugated/ trapezoidal sheet roofing including ridges, hips, valleys and gutters etc. and stacking the materials as directed by the department for all levels
Demolishing brickwork including stacking of serviceable materials and disposal of unserviceable materials as directed for all levels
Demolishing RCC work including stacking of steel bars and disposal of unserviceable material as directed for all levels
Dismantling and removing the existing door and window frame (chowkath) both wooden and steel of different sizes without damaging the walls and removing the frame and necessary repairs to the edges of the walls as directed for all levels. (i) Area of door/window up to 3.00 m2
Boundary DRAIN
Construction of Boundary Drain
Road Surface Drain ( for 10.00 m length)
Earthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified.(a) In Ordinary Soil. Upto 2.00m Depth.
Providing soling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete. (a).Brick on flat soling.
Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately). (a) In prop 1cement: 3 sand :6 coarse aggregate by volume
Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed. (I) In Sub-structure upto plinth level including dewatering if necessary (a) In proportion 1:3.
40 mm thick cement concrete floor consisting of 25 mm under layer of cement concrete in prop. 1:3:6 (1cement : 3 coarse sand : 6 coarse aggregate of 12.5 mm and down) and 15 mm thick wearing layer in cement concrete in prop. 1:1:2 (1cement :1 coarse sand : 2 coarse aggregate of size 10mm down) finished with a floating coat of neat cement finish using cement slurry for bond @ 2.75 kg. per square metre of floor area , wearing layer is to be laid in panels including curing etc. complete as directed.
Cement plaster skirting with cement mortar in prop. 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement including rounding of junctions with floor. (a) 15 mm thick
BOUNDARY WALL
Earthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified.(a) In Ordinary Soil. Upto 2.00m Depth.
Providing soling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete. (a).Brick on flat soling.
Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately). (a) In prop 1cement: 3 sand :6 coarse aggregate by volume
Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level)
a) From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL
(i) TMT Corrosion resistant steel (CRS) reiforcement bar
c) ISI approved Mild steel reinforcement bar(M.S.Bar)
FORM WORK
Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in: Foundation, footings, bases of columns, pile cap, raft and mass concrete works etc. b) Using 25mm thick Plank.
Sides of tie beams, grade beams etc. at or below ground level. (b) Using 25mm thick plank
Columns, Pillars, Posts & Strut (a) Square, Rectangular, polygonal in plan or any shape like Tee/L etc. having plane vertical face (ii) Using 25mm thick plank
REINFORECED CEMENT CONCRETE WORKS
Providing and laying controlled cement concrete of grade M 20 with 20mm down graded stone aggregate including dewatering if necessary, and curing complete, excluding cost of form work and reinforcement for reinforced concrete work (form work and reinforcement will be measured and paid separately). In substructure upto plinth level Foundation, footings, columns with base, tie and plinth beam, grade beam, pile cap, base slab, retaining wall, walls of septic tank, inspection pit and the like and other works not below 100mm thick. in prop: 1:2:4
In super structure Columns, pillars, posts, struts, suspended floor, roof, landing, shelf and support, balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase including preparing of top surfaces and furnishing and nosing. (b) in prop: 1:2:4
Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed. (I) In Sub-structure upto plinth level including dewatering if necessary (b) In proportion 1:4.
1st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paid separately) (A) 112mm thick brick wall (a) In cement mortar in proportion 1:4. (1 cement:4 sand)
15 mm thick Cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed. A) On rough side a) In cement mortar 1:3
a) Applying one coat of cement primer of approved brand and manufacture on new wall surface after throughly brooming the surfaces free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth.
b) Finishing wall with water proofing cement paint of approved brand and manufacture and of required shade on new wall surface (two coats) to give an even shade after throughly brooming the surfaces to remove all dirt and remains of loose powdered materials.
INSTALLATION OF AIR CONDITION SYSTEM
Supplying with installation testing and commissioning of Hi -- wall 4 STAR rating non ducted split type air conditioner of the following capacity with cordless remote complete with indoor and outdoor unit, copper pipe and electrical connection as approved by the Deptt.)up to 5 m between the room unit and out door unit as directed by the department. (Carrier make) Kurve/ Voltas make) Model PLATINUM 4S 1.5 Ton Capacity
Electrical Service connection (LS)
MRINMOY JYOTI THOUSEN
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .