Loading…
Loading…
Tender Value
₹3.3 Cr
EMD Value
₹1.7 L
Closing Date
15 Jun 2026, 6:00 pm
CEO
BHOPAL SMART CITY DEVELOPMENT CORPORATION LIMIITED
Design, Development, Construction, testing and commissioning of 24x7 water distribution system infrastructure for ABD area along with O AND M for five year.
2026_UAD_507977_1
MPBSCDCL /TENDER NO- 323
Open Tender
Civil Works - Water Works
365 days
ABD Area Under Bhopal Smart City
PLEASE REFER TENDER DOCUMENT
3 documents required · 3 mandatory
₹15,000
₹1.7 L
BHOPAL SMART CITY DEVELOPMENT CORPORATION LIMIITED
15 May 2026
15 May 2026
16 Jun 2026
15 May 2026
15 Jun 2026
15 May 2026
22 May 2026
Providing, laying, Jointing & field testing of High Density Polyethylene pipes, (HDPE) confirming to IS 4984/ 14151/ 12786/ 13488 with necessary jointing material like mechanical connector or jointing pipes by heating to the ends of pipes with the help of Teflon coated electric mirror/ heater to the required temperature and then pressing the ends together against each other, to form a monolithic & leak proof joint by thermosetting process. It may be required to be done with Jacks/Hydraulic Jacks/ But fusion machine. (50mm & above fusion jointed & below 50mm mechanical jointed)
Earth work in excavation for foundation, trenches for pipes / cables or drains etc. by mechanical means / manual means (exceeding 30cm in depth.) including ramming of bottom, dressing of sides, disposal of excavated earth including of all liftand lead upto 50m. Disposed earth to belevelled and neatly dressed.
Filling by available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Filling with moorum for pipe bedding or over the pipe including supply of moorum/sand
Providing & fixing of following Cast iron double flanged sluice valves as per I.S.:14846-2000 fitted with cast iron cap including jointing & testing with cost of jointing material such as bolts, nuts, rubber insertions etc. all complete PN-1.6
Designing, Supplying, Installing, Commissioning & testing of Flow Control Valve with level control / Pressure reducing valve/ AlttitudeValve for inlet/ outlet with flow controlling, pressure controlling & monitoring on web and to the pipeline feeding to ESR/MBR/GSR with cable, PLC SCADA etc. complete
Providing & fixing cast iron double air valves, flangedwithout in-built isolating valve as per IS : 14845-2000 including jointing & testing with cost of jointing material andrubber insertion all complete PN-1.6
Supply and Installation of Woltman Type, dry dial,inferential type, Magnetically coupled, Class B‟accuracy water meters in any position with interchangeable mechanism Conforming to ISO 4064:1993 standard with EEC certification mark, with IP68protection class copper can register with 5 mm temperedmineral glass cover, AMR compatibility with 5 years warranty complete and successful accuracy testcertificate from FCRI, Palakkad with C.I. Body “T‟ Typestructure:
Construction of Brick masonry valve chamber with 20 cm thick wall in 1:6 C.M. with 12mm thick 1:4 Cement Plaster and base course 10 cm. thick in M15. Inside Dimensions 110x80x100cm M-20 RCC chamber cover size 130x120cmx10cm including cost of materials, labour, finished with floating coat of neat cement etc. complete.
Providing, laying, Jointing & field testing of High Density Polyethylene pipes, (HDPE) confirming to IS 4984/ 14151/ 12786/ 13488 with necessary jointing material like mechanical connector or jointing pipes by heating to the ends of pipes with the help of Teflon coated electric mirror/ heater to the required temperature and then pressing the ends together against each other, to form a monolithic & leak proof joint by thermosetting process. It may be required to be done with Jacks/Hydraulic Jacks/ But fusion machine. (50mm & above fusion jointed & below 50mm mechanical jointed)
Earth work in excavation for foundation, trenches for pipes / cables or drains etc. by mechanical means / manual means (exceeding 30cm in depth.) including ramming of bottom, dressing of sides, disposal of excavated earth including of all liftand lead upto 50m. Disposed earth to belevelled and neatly dressed.
Filling by available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Filling with moorum for pipe bedding or over the pipe including supply of moorum/sand
Providing & fixing of following Cast iron double flanged sluice valves as per I.S.:14846-2000 fitted with cast iron cap including jointing & testing with cost of jointing material such as bolts, nuts, rubber insertions etc. all complete PN-1.6
Designing, Supplying, Installing, Commissioning & testing of Flow Control Valve with level control / Pressure reducing valve/ AlttitudeValve for inlet/ outlet with flow controlling, pressure controlling & monitoring on web and to the pipeline feeding to ESR/MBR/GSR with cable, PLC SCADA etc. complete
Providing & fixing cast iron double air valves, flangedwithout in-built isolating valve as per IS : 14845-2000 including jointing & testing with cost of jointing material andrubber insertion all complete PN-1.6
Supply and Installation of Woltman Type, dry dial,inferential type, Magnetically coupled, Class B‟accuracy water meters in any position with interchangeable mechanism Conforming to ISO 4064:1993 standard with EEC certification mark, with IP68protection class copper can register with 5 mm temperedmineral glass cover, AMR compatibility with 5 years warranty complete and successful accuracy testcertificate from FCRI, Palakkad with C.I. Body “T‟ Typestructure:
Construction of Brick masonry valve chamber with 20 cm thick wall in 1:6 C.M. with 12mm thick 1:4 Cement Plaster and base course 10 cm. thick in M15. Inside Dimensions 110x80x100cm M-20 RCC chamber cover size 130x120cmx10cm including cost of materials, labour, finished with floating coat of neat cement etc. complete.
Providing, laying, Jointing & field testing of High Density Polyethylene pipes, (HDPE) confirming to IS 4984/ 14151/ 12786/ 13488 with necessary jointing material like mechanical connector or jointing pipes by heating to the ends of pipes with the help of Teflon coated electric mirror/ heater to the required temperature and then pressing the ends together against each other, to form a monolithic & leak proof joint by thermosetting process. It may be required to be done with Jacks/Hydraulic Jacks/ But fusion machine. (50mm & above fusion jointed & below 50mm mechanical jointed)
Earth work in excavation for foundation, trenches for pipes / cables or drains etc. by mechanical means / manual means (exceeding 30cm in depth.) including ramming of bottom, dressing of sides, disposal of excavated earth including of all liftand lead upto 50m. Disposed earth to belevelled and neatly dressed.
Filling by available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Filling with moorum for pipe bedding or over the pipe including supply of moorum/sand
Providing & fixing of following Cast iron double flanged sluice valves as per I.S.:14846-2000 fitted with cast iron cap including jointing & testing with cost of jointing material such as bolts, nuts, rubber insertions etc. all complete PN-1.6
Designing, Supplying, Installing, Commissioning & testing of Flow Control Valve with level control / Pressure reducing valve/ AlttitudeValve for inlet/ outlet with flow controlling, pressure controlling & monitoring on web and to the pipeline feeding to ESR/MBR/GSR with cable, PLC SCADA etc. complete
Providing & fixing cast iron double air valves, flangedwithout in-built isolating valve as per IS : 14845-2000 including jointing & testing with cost of jointing material andrubber insertion all complete PN-1.6
Supply and Installation of Woltman Type, dry dial,inferential type, Magnetically coupled, Class B‟accuracy water meters in any position with interchangeable mechanism Conforming to ISO 4064:1993 standard with EEC certification mark, with IP68protection class copper can register with 5 mm temperedmineral glass cover, AMR compatibility with 5 years warranty complete and successful accuracy testcertificate from FCRI, Palakkad with C.I. Body “T‟ Typestructure:
Construction of Brick masonry valve chamber with 20 cm thick wall in 1:6 C.M. with 12mm thick 1:4 Cement Plaster and base course 10 cm. thick in M15. Inside Dimensions 110x80x100cm M-20 RCC chamber cover size 130x120cmx10cm including cost of materials, labour, finished with floating coat of neat cement etc. complete.
Providing, laying, Jointing & field testing of High Density Polyethylene pipes, (HDPE) confirming to IS 4984/ 14151/ 12786/ 13488 with necessary jointing material like mechanical connector or jointing pipes by heating to the ends of pipes with the help of Teflon coated electric mirror/ heater to the required temperature and then pressing the ends together against each other, to form a monolithic & leak proof joint by thermosetting process. It may be required to be done with Jacks/Hydraulic Jacks/ But fusion machine. (50mm & above fusion jointed & below 50mm mechanical jointed)
Earth work in excavation for foundation, trenches for pipes / cables or drains etc. by mechanical means / manual means (exceeding 30cm in depth.) including ramming of bottom, dressing of sides, disposal of excavated earth including of all liftand lead upto 50m. Disposed earth to belevelled and neatly dressed.
Filling by available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Filling with moorum for pipe bedding or over the pipe including supply of moorum/sand
Providing & fixing of following Cast iron double flanged sluice valves as per I.S.:14846-2000 fitted with cast iron cap including jointing & testing with cost of jointing material such as bolts, nuts, rubber insertions etc. all complete PN-1.6
Designing, Supplying, Installing, Commissioning & testing of Flow Control Valve with level control / Pressure reducing valve/ AlttitudeValve for inlet/ outlet with flow controlling, pressure controlling & monitoring on web and to the pipeline feeding to ESR/MBR/GSR with cable, PLC SCADA etc. complete
Providing & fixing cast iron double air valves, flangedwithout in-built isolating valve as per IS : 14845-2000 including jointing & testing with cost of jointing material andrubber insertion all complete PN-1.6
Construction of Brick masonry valve chamber with 20 cm thick wall in 1:6 C.M. with 12mm thick 1:4 Cement Plaster and base course 10 cm. thick in M15. Inside Dimensions 110x80x100cm M-20 RCC chamber cover size 130x120cmx10cm including cost of materials, labour, finished with floating coat of neat cement etc. complete.
1.The ESR height at Platinum Plaza and Jawahar Baldhan has been considered as 17 m from ground level, whereas the ESR height at TT Nagar has been taken as 10 m. Accordingly, the pipeline sizes have been designed and calculated.
2.To maintain the pressure upto UGT levels the interconnected network is being designed
Providing, laying, Jointing & field testing of High Density Polyethylene pipes, (HDPE) confirming to IS 4984/ 14151/ 12786/ 13488 with necessary jointing material like mechanical connector or jointing pipes by heating to the ends of pipes with the help of Teflon coated electric mirror/ heater to the required temperature and then pressing the ends together against each other, to form a monolithic & leak proof joint by thermosetting process. It may be required to be done with Jacks/Hydraulic Jacks/ But fusion machine. (50mm & above fusion jointed & below 50mm mechanical jointed)
Providing and laying Equal Tee confirming to IS specifications (HDPE)
Earth work in excavation for foundation, trenches for pipes / cables or drains etc. by mechanical means / manual means (exceeding 30cm in depth.) including ramming of bottom, dressing of sides, disposal of excavated earth including of all liftand lead upto 50m. Disposed earth to belevelled and neatly dressed.
Filling by available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Filling with moorum for pipe bedding or over the pipe including supply of moorum/sand
Providing and laying Reducer 8 kg/sq.cm : confirming to IS specifications.
Providing and laying Bend 90ْ confirming to IS specifications.
Electro Fusion End Cap
Providing & fixing of following Cast iron double flanged sluice valves as per I.S.:14846-2000 fitted with cast iron cap including jointing & testing with cost of jointing material such as bolts, nuts, rubber insertions etc. all complete PN-1.6
Designing, Supplying, Installing, Commissioning & testing of Flow Control Valve with level control / Pressure reducing valve/ AlttitudeValve for inlet/ outlet with flow controlling, pressure controlling & monitoring on web and to the pipeline feeding to ESR/MBR/GSR with cable, PLC SCADA etc. complete
Providing & fixing cast iron double air valves, flangedwithout in-built isolating valve as per IS : 14845-2000 including jointing & testing with cost of jointing material andrubber insertion all complete PN-1.6
Supply and Installation of Woltman Type, dry dial,inferential type, Magnetically coupled, Class B‟accuracy water meters in any position with interchangeable mechanism Conforming to ISO 4064:1993 standard with EEC certification mark, with IP68protection class copper can register with 5 mm temperedmineral glass cover, AMR compatibility with 5 years warranty complete and successful accuracy testcertificate from FCRI, Palakkad with C.I. Body “T‟ Typestructure:
Construction of Brick masonry valve chamber with 20 cm thick wall in 1:6 C.M. with 12mm thick 1:4 Cement Plaster and base course 10 cm. thick in M15. Inside Dimensions 110x80x100cm M-20 RCC chamber cover size 130x120cmx10cm including cost of materials, labour, finished with floating coat of neat cement etc. complete.
Providing, laying, Jointing & field testing of High Density Polyethylene pipes, (HDPE) confirming to IS 4984/ 14151/ 12786/ 13488 with necessary jointing material like mechanical connector or jointing pipes by heating to the ends of pipes with the help of Teflon coated electric mirror/ heater to the required temperature and then pressing the ends together against each other, to form a monolithic & leak proof joint by thermosetting process. It may be required to be done with Jacks/Hydraulic Jacks/ But fusion machine. (50mm & above fusion jointed & below 50mm mechanical jointed)
Providing and laying Equal Tee confirming to IS specifications (HDPE)
Earth work in excavation for foundation, trenches for pipes / cables or drains etc. by mechanical means / manual means (exceeding 30cm in depth.) including ramming of bottom, dressing of sides, disposal of excavated earth including of all liftand lead upto 50m. Disposed earth to belevelled and neatly dressed.
Filling by available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Filling with moorum for pipe bedding or over the pipe including supply of moorum/sand
Providing and laying Bend 90ْ confirming to IS specifications.
Providing and laying Reducer 8 kg/sq.cm : confirming to IS specifications.
Electro Fusion End Cap
Providing & fixing of following Cast iron double flanged sluice valves as per I.S.:14846-2000 fitted with cast iron cap including jointing & testing with cost of jointing material such as bolts, nuts, rubber insertions etc. all complete PN-1.6
Designing, Supplying, Installing, Commissioning & testing of Flow Control Valve with level control / Pressure reducing valve/ AlttitudeValve for inlet/ outlet with flow controlling, pressure controlling & monitoring on web and to the pipeline feeding to ESR/MBR/GSR with cable, PLC SCADA etc. complete
Providing & fixing cast iron double air valves, flangedwithout in-built isolating valve as per IS : 14845-2000 including jointing & testing with cost of jointing material andrubber insertion all complete PN-1.6
Supply and Installation of Woltman Type, dry dial,inferential type, Magnetically coupled, Class B‟accuracy water meters in any position with interchangeable mechanism Conforming to ISO 4064:1993 standard with EEC certification mark, with IP68protection class copper can register with 5 mm temperedmineral glass cover, AMR compatibility with 5 years warranty complete and successful accuracy testcertificate from FCRI, Palakkad with C.I. Body “T‟ Typestructure:
Construction of Brick masonry valve chamber with 20 cm thick wall in 1:6 C.M. with 12mm thick 1:4 Cement Plaster and base course 10 cm. thick in M15. Inside Dimensions 110x80x100cm M-20 RCC chamber cover size 130x120cmx10cm including cost of materials, labour, finished with floating coat of neat cement etc. complete.
Providing, laying, Jointing & field testing of High Density Polyethylene pipes, (HDPE) confirming to IS 4984/ 14151/ 12786/ 13488 with necessary jointing material like mechanical connector or jointing pipes by heating to the ends of pipes with the help of Teflon coated electric mirror/ heater to the required temperature and then pressing the ends together against each other, to form a monolithic & leak proof joint by thermosetting process. It may be required to be done with Jacks/Hydraulic Jacks/ But fusion machine. (50mm & above fusion jointed & below 50mm mechanical jointed)
Providing and laying Equal Tee confirming to IS specifications (HDPE)
Earth work in excavation for foundation, trenches for pipes / cables or drains etc. by mechanical means / manual means (exceeding 30cm in depth.) including ramming of bottom, dressing of sides, disposal of excavated earth including of all liftand lead upto 50m. Disposed earth to belevelled and neatly dressed.
Filling by available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Filling with moorum for pipe bedding or over the pipe including supply of moorum/sand
Providing and laying Reducer 8 kg/sq.cm : confirming to IS specifications.
Providing and laying Bend 90ْ confirming to IS specifications.
Electro Fusion End Cap
Providing & fixing of following Cast iron double flanged sluice valves as per I.S.:14846-2000 fitted with cast iron cap including jointing & testing with cost of jointing material such as bolts, nuts, rubber insertions etc. all complete PN-1.6
Designing, Supplying, Installing, Commissioning & testing of Flow Control Valve with level control / Pressure reducing valve/ AlttitudeValve for inlet/ outlet with flow controlling, pressure controlling & monitoring on web and to the pipeline feeding to ESR/MBR/GSR with cable, PLC SCADA etc. complete
Providing & fixing cast iron double air valves, flangedwithout in-built isolating valve as per IS : 14845-2000 including jointing & testing with cost of jointing material andrubber insertion all complete PN-1.6
Supply and Installation of Woltman Type, dry dial,inferential type, Magnetically coupled, Class B‟accuracy water meters in any position with interchangeable mechanism Conforming to ISO 4064:1993 standard with EEC certification mark, with IP68protection class copper can register with 5 mm temperedmineral glass cover, AMR compatibility with 5 years warranty complete and successful accuracy testcertificate from FCRI, Palakkad with C.I. Body “T‟ Typestructure:
Construction of Brick masonry valve chamber with 20 cm thick wall in 1:6 C.M. with 12mm thick 1:4 Cement Plaster and base course 10 cm. thick in M15. Inside Dimensions 110x80x100cm M-20 RCC chamber cover size 130x120cmx10cm including cost of materials, labour, finished with floating coat of neat cement etc. complete.
Providing and laying in position Plain cement concrete (PCC) of specified grade excluding the cost of centering and shuttering
Providing and laying in position ready mix M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix , manufactured in fully automatic batching Plant and transported to site of work in transit mixer for all leads having continuous agitated mixer including pumping of ready mix concrete from transit mixer to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including cost of Admixtures in recommended proportions as per IS 9103 to accelerate/retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in- charge.
Rater/year
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.29 MB
rfp.pdf
Tender Documents • 1.82 MB
Financial_Bid.xls
Other Document • 0.42 MB
Download all tender documents and submit your bid