Loading…
Loading…
Tender Value
₹52.2 L
EMD Value
₹1.0 L
Closing Date
15 Apr 2026, 3:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
TENDER SEC
14 conditions · 2 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or "V" whichever is less V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover.
The tenderer must have successfully completed or substantially completed any of the following during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or One similar work each costing not less than the amount equal to 60% of advertised value of the tender.
Defination of Similar Work :- Following works will be considered similar work: (i) Electrification of service building. (ii) Electrification of staff quarters. (iii) Electrification of offices. (iv) Electrification of Road and Colony lighting. (v) Rewiring of quarters and service buildings. (vi) Earthing arrangement (Plate and Pipe Earthing) for quarters, service buildings, LT/HT Panels etc. (vii) Installation, testing and commissioning of Electrical sub-station. (viii) Laying of HT cables. (ix) Laying of LT cables.
38 conditions · 18 needing a document upload
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Bid Security Declaration (Annexure-1 of Chapter-2): I/We, M/s (Name of bidder) am/are aware that I/We have been exempted from submission of Bid Security/Earnest Money Deposit in lieu of this Bid Security Declaration. I/We understand and accept that if I/We withdraw my/our bid within bid validity period or if awarded the tender and on being called upon to submit the Performance Guarantee/Performance Security fail to submit the same within the stipulated time period mentioned in tender documents or on being called upon to sign the contract agreement fail to sign the same within stipulated period mentioned in tender documents, I/We i.e., the bidder shall be banned from submission of bids in any Works / Service Tender issued by Indian Railways for a period of 12 months from the date of such banning done on e- platform IREPS.
Performance Guarantee: The successful bidder shall have to submit a Performance Guarantee (PG) within 21 (Twenty one) days from the date of issue of Letter of Acceptance (LOA). Extension of time for submission of PG beyond 21 (Twenty one) days and upto 60 days from the date of issue of LOA may be given by the Authority who is competent to sign the contract agreement. However, a penal interest of 12% per annum shall be charged for the delay beyond 21(Twenty one) days, i.e. from 22nd day after the date of issue of LOA. Further, if the 60thday happens to be a declared holiday in the concerned office of the Railway, submission of PG can be accepted on the next working day. In all other cases, if the Contractor fails to submit the requisite PG even after 60 days from the date of issue of LOA, the contract is liable to be terminated. In case contract is terminated railway shall be entitled to forfeit Bid Security and other dues payable to the contractor against that particular contract, subject to maximum of PG amount. In case a tenderer has not submitted Bid Security on the strength of their registration as a Startup recognized by Department of Industrial Policy and Promotion (DIPP) under Ministry of Commerce and Industry, DIPP shall be informed to this effect. The failed Contractor shall be debarred from participating in re-tender for that work.
The successful bidder shall submit the Performance Guarantee (PG) in any of the following forms, amounting to 5% of the original contract value:- (i) A deposit of Cash; (ii) Irrevocable Bank Guarantee; (iii) Insurance Surety Bond as per Annexure-7 of Chapter-6 (ACS 9 of IRGCC-2022). Note: In case of extension of Date of Completion selected bidder needs to submit extended Insurance Surety Bond/ Fresh Insurance Surety Bond/fresh Performance Security in any form as given above, before expiry of existing Insurance Surety Bond (iv) Government Securities including State Loan Bonds at 5% below the market value; (v) Pay Orders, Demand Drafts tendered by any scheduled Commercial Bank of India. (vi) Guarantee Bonds executed or Deposits Receipts tendered by any Scheduled Commercial Bank of India; (vii) Deposit in the Post Office Saving Bank; (viii) Deposit in the National Savings Certificates; (ix) Twelve years National Defence Certificates; (x) Ten years Defence Deposits; (xi) National Defence Bonds and (xii) Unit Trust Certificates at 5% below market value or at the face value whichever is less. Also, FDR in favour of FA&CAO (free from any encumbrance) may be accepted.
If a tender is accepted on the quoted rates of bidder which is below the advertised tender value, an additional performance security shall be submitted by the bidder as below: (a) Bid 1.1.1 quoted Below 0-5% (inclusive) - Additional Performance Security is NIL (b) Bid quoted Below 5% - Additional 5% Performance Security shall be submitted.
The Earnest Money deposited with the tender of successful tenderer will be retained as part of security deposit which will be 5 percent of the value of work awarded. The balance amount of security deposit will recovered on account bill of the work @ 6 percent till it reached up to 5 percent of the value of work including earnest money.
The contract shall be governed by the provision of Indian Railways Standard General Conditions of Contract-2022 (Latest) with correction slips up to the date of uploading of tender.
(i) Before submitting a tender, the tender will be deemed to have satisfied himself by actual inspection of the site and locality of the works, that all conditions liable to be encountered during the execution of the works are taken into account and that the rates he enters in the tender forms are adequate and all inclusive to accord with the provisions in Clause-37 of the Standard General Conditions of Contract for the completion of works to the entire satisfaction of the Engineer. (ii) Tenderer will examine the various provisions of The General Goods and Services Tax Act, 2017 (CGST)/Integrated Goods and Services Tax Act, 2017(IGST)/Union Territory Goods and Services Tax Act, 2017(UTGST)/ respective state's State Goods and Services Tax Act, (SGST) also, as notified by Central/State Govt& as amended from time to time and applicable taxes before bidding. Tenderers will ensure that full benefit of Input Tax Credit (ITC) likely to be availed by them is duly considered while quoting rates. (iii) The successful tenderer who is liable to be registered under CGST/IGST/UTGST/SGST Act shall submit GSTIN along with other details required under CGST/IGST/UTGST/SGST Act to railway immediately after the award of contract, without which no payment shall be released to the contractor. The contractor shall be responsible for deposition of applicable GST to the concerned authority. (iv) In case the successful tenderer is not liable to be registered under CGST/IGST/UTGST/SGST Act, the railway shall deduct the applicable GST from his/their bills under reverse charge mechanism (RCM) and deposit the same to the concerned authority.
INDIAN RAILWAY STANDARD GERNERAL CONDITION OF CONTRACT is available on the Indian Railways website. Tenderers are requested to visit the website and be aware of the Terms and Conditions of GCC.
Offer Submission Period - Fifteen days prior to opening of tender, during which tenderers can submit their offer.
The Earnest Money of the Unsuccessful Tenderer[s] as here in before provided will be returned to the Unsuccessful Tenderer[s] but the Railway shall not be responsible for any loss or depreciation that may happen to the Earnest Money for the due performance of the stipulation to keep the offer open for the period specified in the offer or to the Earnest Money while in their possession, nor be liable to pay interest thereof. The Earnest Money Amount will be directly credited to the Accounts of Unsuccessful Tenderer[s] as early as possible after the tender case is finalised.
Any notes appearing in the Schedule of Items, Quantities and Rates will take precedence over Additional Special Conditions of Contract and also GENERAL CONDITIONS OF CONTRACT and STANDARD SPECIFICATIONS. The Railway will take for granted that Tenderer[s] has/have acquainted himself/themselves with all terms and words used in the tender before submitting the tender.
Bank Guarantee [BGs] to be submitted by contractors as Performance Guarantee should be sent directly to the concerned authorities by the issuing bank under Registered post AD.
Bidders are not required to re-upload the tender document/NIT under his digital signature.
Electrification of New Station Building at existing platform no. 2, FOB, Approach Road, Machine siding, Underpass at LC-6 and Circulating Area at Mahrajganj Station
OT-22-2025
OT-22-2025
Open
Works - General
6 Months
Gorakhpur, Uttar Pradesh
₹0
₹1.0 L
15 Apr 2026
24 Mar 2026
1 Apr 2026
107 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 52,21,025.76 | ||
| — | — | — | 35,175.4 | ||
| Supply, fixing and commissioning of modular type switches, sockets & bell push as per latest IS. | for details. | Breakup | — | — | |
| — | — | — | 38,983.99 | ||
| Supply & fixing GI box alongwith modular base & cover plate for modular switches comforming to IS:3854/1997 (Latest version)/flush type socket outlet as per IS;1293-1988 (Latest version) including connection, testing & commissioning complete inall respect. | for details. | Breakup | — | — | |
| — | — | — | 6,52,472.72 | ||
| Supply & erection of PVC insulated multi stranded copper conductor single core FR cable conforming to IS:694 (Latest version) & its drawing in laid (Recessed/surface) PVC conduit pipe for wiring/sub-main/main as required including connection testing & commissioning. In addition to it suitable size of T-bend socket & other joints which is required provided by contractor. (incl, renovation of wiring of existing PF shelter, FOB, Station building etc) | for details. | Breakup | — | — | |
| — | — | — | 4,128.75 | ||
| Supply, erection, testing & commissioning of Mobile charging board made by hard board 10 mm thick size 205mm x 215 mm x 60 mm, 04 Nos. socket 3 pins 6 amps. On each board, 1 No. indication lamp on each board, fuse kit kat on each board, fixing of 205 mm x 160 mm x 10 mm thick hard board sheet for supporting of Mobile phone. | — | 15.00 | — | — | |
| — | — | — | 31,684.95 | ||
| Supply & fixing Prewired segregated sheet steel phosphatised powder coated 8 way SPN MCB,DB's prefitted with incoming 63AMP. 2pole MCB-1 no and outgoing 6/10/16/20 A. single poleMCB -6 Nos.breaking capcity 10KA, bus-bar,neutral link, earth bar, plates. Confirming to IS/IEC 60898-2;2003 and IS:13032/1991 including, drilling holes on the board, its connection, earthing the body etc. complete in all respect. | — | 15.00 | — | — | |
| — | — | — | 27,825.72 | ||
| Supply, testing & commissioning of Wall Mounting Type Air Circulator Electric Fan having 600 millimeter (mm) sweep size, | — | 4.00 | — | — | |
| — | — | — | 1,110 | ||
| Cutting circular holes in brick masonary wall, and making smooth surfacing plastering/painting etc, for exhaust fan installation, including all types of tools and machinary and material. | — | 10.00 | — | — | |
| — | — | — | 22,661.6 | ||
| Supply, installation, testing & commissioning of Exhaust fan fiber body 300 mm with louverindoor type window/wall Mount, as per IS: 2312 for 230 Volt AC Single. | — | 10.00 | — | — | |
| — | — | — | 5,056.52 | ||
| Supply , fixing , testing & commissioning of Exhaust fan plastic body 250 mm indoor type window/wall Mount as per IS:2312 with cover flap (with louver) 230 Volt AC single Phase. | — | 4.00 | — | — | |
| — | — | — | 4,509.5 | ||
| Supply & fixing of CPVC pipe 25 mm dia Conforming to IS: (Latest version) with accessories, Jn. Box etc including cleating/ clamping/fixing on wall/pillar at suitable interval etc. as per direction of Engg-In-charge. (Shelter & FOB) | — | 50.00 | — | — | |
| — | — | — | 900 | ||
| Supply and fixing of 15/20 Amp top plug, its connection etc complete in all respect | — | 10.00 | — | — | |
| — | — | — | 21,836.75 | ||
| Dismantling of over head lines comprising of copper/aluminium overhead conductor, G.I. wire, cross arms, insulators etc and shifting to a suitable location as per direction of Engineer Incharge at site. | — | 325.00 | — | — | |
| — | — | — | 2,68,137 | ||
| Design,Manufacturing,supply,installation,Testing & commissioning of LED based signage board of different size & single/Double side as requiredin hindi or english as required by Railway as per attached Specification complete in all respect.(for station name board) | — | 150.00 | — | — | |
| — | — | — | 1,52,328.05 | ||
| Earthing with G.I. earth pipe 4.5 metre long, 40mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required and connection with 40mm x 4 mm GI strip/flat instead of GI wire. | — | 35.00 | — | — | |
| — | — | — | 89,753.6 | ||
| Supplying and fixing surface/ recess mounted, vertical type, duly powder coated sheet steel made 415 V, TPN distribution board, consisting of100 A four pole MCCB-1 No,63 A DP MCB- 1No,32 A SP,MCB- 2Nos,16 A SP MCB- 1 No10 ASP, MCB- 1 No , inclusive of 100A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB as required. | — | 8.00 | — | — | |
| — | — | — | 3,84,000 | ||
| Supply, installation, testing & commissioning of 5 Star rated 1.5 Ton Split Type Air Conditioner | — | 8.00 | — | — | |
| — | — | — | 2,150 | ||
| Supply, installation, testing & commissioning of instantaneous tripping range enclosed board with 25 Amp. Mini MCB -1 no.10 KA, single phase confirming to IS:13032/1991, including drilling holes on the wall/board. Its connection, carting etc complete in all respect. (AC point) | — | 10.00 | — | — | |
| — | — | — | 2,242.2 | ||
| Supply installation testing and commissioning of modular socket outlet 6/20 Amp. for 230 V, 50 Hz, AC Supply | — | 10.00 | — | — | |
| — | — | — | 17,714.14 | ||
| Supply, installation, testing & commissioning of wall /Din rail mounted digital timer based Automatic change over for control of 2 to 6 AC, comprising of inbuilt contactor, connector, neutral link, LED indicator with wiring etc suitable for cyclic operation of two any type of Air- Conditioner. Each AC can be kept ON from 1 hour to 24 hours complete in all aspect. | — | 2.00 | — | — | |
| — | — | — | 32,078 | ||
| Supply and drawing of 8 SWG G.I. wire for Earthing purpose, complete in all respect. | — | 4300.00 | — | — | |
| — | — | — | 4,83,183.3 | ||
| Supply, delivery & Fixing of octagonal pole hot Dip Galvanized in single dip average 70 micron DFT, designed for maximum wind speed of 169KM/Hr.,BOP-7030 type pole of 6 Mtr long, top dia 70mm, bottom dia.130mm sheet thickness 3mm, in single section with Base plate(220x220x12)mm (LxBxT) with4x20mm dia. 700 mm long with 100mm projection foundation bolt complete with smart pack junction box with bakelite sheet, 6A MCB & stud terminals (for mounting inside base component of pole) and internal wiring for terminal to fitting with 2x2.5 sq.mm cable including single arm 1 mtr. long suitable for 3 to 10 mtr. pole | — | 38.00 | — | — | |
| — | — | — | 19,914.66 | ||
| Supply & fixing of Geyser of 20 Ltr storage capacity 5 star rated 230 volt AC steel body, material of tank stainless steel conforming to IS:2082:2018 with all accessories complete in all respect. | — | 2.00 | — | — | |
| — | — | — | 1,80,666 | ||
| Supply, installation, testing & commissioning of 60 Watt street light LED luminaire fittings with 5 year warranty as per attached technical particular Complete in all respect. | — | 50.00 | — | — | |
| — | — | — | 1,88,696.16 | ||
| Supply of 3 KVA UPS Single phase 160V-260V,50 HZ input supply, with 2 hour backup at full load complete in all respect. (Window ticketing/station building | — | 2.00 | — | — | |
| — | — | — | 29,771.5 | ||
| Supply of G.I. hot dip power coated perforated type cable tray size 14 SWG (2 mm) with cover, Hardware etc as per IS:2629/4759 for cabling on wall/pillar/ground or wherever is required complete in all respect. (for proper cabling of existing & new overhead cabling) i)Size 300mmx100mm | — | 50.00 | — | — | |
| — | — | — | 85,000 | ||
| Supply and fabrication of MS ladder type cable tray having 310 mm width and 100 mm height made with 2.5 mm MS sheet | — | 100.00 | — | — | |
| — | — | — | 7,425.56 | ||
| Hand driven generator (Megger) type insulation tester, 1000V, Range from 0-1000 Mega ohm, As IS:2992:1987 | — | 2.00 | — | — | |
| — | — | — | 24,780 | ||
| Supply of Aluminimum self supporting sliding Ladders, 20 feet height. | — | 2.00 | — | — | |
| — | — | — | 6,019.3 | ||
| Supply & testing of digital earth resistance tester 1000 Ohm with re-chargeable Battery with Kit for earth resistance & accessories Complete in all respect. | — | 2.00 | — | — | |
| — | — | — | 22,835 | ||
| Supply, installation, testing & energization of ceiling mounting 2 feet x2 feet,36 watt LED fitting or equivalent decorative LED luminiare as per direction of engineer in- charge with 3 year warranty with required size of clamp, ceiling rose etc complete in all respect | — | 10.00 | — | — | |
| — | — | — | 1,18,348.24 | ||
| Supply & fixing of PVC conduit pipe 25 mm dia2 mm thick conforming to IS:9537/Pt. III/1983 (Latest version) with accessories, Jn. Box etc including making, chase, plastering/clamping etc. | — | 3272.00 | — | — | |
| — | — | — | 26,399.4 | ||
| Supply, fixing, testing & commissioning of LED Down Lighters round & square, 10W Single Phase 230 Volt AC | — | 20.00 | — | — | |
| — | — | — | 80,832 | ||
| Supply, installation, testing & energization of 18-20 watt LED tube light fitting with 3 year warranty with required size of clamp etc complete in all respect. | — | 160.00 | — | — | |
| — | — | — | 7,444.96 | ||
| Dismantling of Existing Tubular/PSC/GI pole by excavation/ breaking CC foundation and handing over to state authority as per direction of Engineer-In-charge at site. | — | 8.00 | — | — | |
| — | — | — | 72,641.44 | ||
| Supply,fixing,testing & commissioning of 63/100A (capacity as per requirement) 4 pole MCCB with enclosure Breaking capacity -25 KA. | — | 8.00 | — | — | |
| — | — | — | 9,18,867 | ||
| Supply & laying of fire retardent,rodent proof double walled corrugated (DWC) pipes of 90mm outer dia and 76mm nominal inner dia meter confirming to IS: 14930 Part -II along with all accessories(socket/coupler and T joint where ever required) including excavation of 110cm depth and 40cm wide cable trench,in all kinds of soil and its refilling with the same excavated soil with laying of DWC pipe of required for laying and protection of power cable | — | 4300.00 | — | — | |
| — | — | — | 4,41,719.2 | ||
| All work pertaining to Horizontal Directional drilling (HDD/Boring and trenchless cable it includes supply transportation and insertion of self lubricated HDPE pipe of minimum 8 mm thick and 125 mm outer dia conforming to IS: 4984/1995 and laying of various cables in HDPE pipe as permisible depending on cable size in boring under the track/road will be crossed. The depth of Horizontal boring should be minimum 1.65 Mtr.upto 3 Mtr from rail flange/road level. Note: The bore and the laying of cable in the bore under the track/road as per direction of Engineer incharge. | — | 520.00 | — | — | |
| — | — | — | 22,269.44 | ||
| Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required (4 core 120 Sq.mm) | — | 8.00 | — | — | |
| — | — | — | 49,950.6 | ||
| Making support for cable by GI Pipe 100 mm dia B class on pole/ wall/ FOB/Shelter, conforming to IS:1239 complete in all respect. | — | 70.00 | — | — | |
| — | — | — | 77,637.42 | ||
| Supply, installation,testing & commissioning of 5 H.P, 3 Ph,415V capacity Mud water Sump Pump with suitable auto start, stop panel box, inbuilt NRV overload & Thermal protection complete in all respect. | — | 1.00 | — | — | |
| — | — | — | 6,480 | ||
| Supply, fixing, testing & commissioning of circular LED fitting 15 watt with 3 year warranty with required size of clamp etc complete in all respect. | — | 6.00 | — | — | |
| — | — | — | 2,11,783.19 | ||
| Design, Supply, installing, testing& commissioning of LT distribution panel with copper bus-bar 200A,consisting with the followingaccessories : (i) Panel board of MSsheet 1.6 mm thick, re-inforcement with 2.5mm thick members and channel arranging rakes and shelves of suitable size(ii) Incomer :MCCB 100A ,4 Pole,10KA-01 No, Changeover switch100Amp.4 pole - 01Nos ,Multifunction Meter-1 set, CT,Indication lamp R,Y,B (LED) (iii)Outgoing: 63A 4 pole MCCB-02Nos , 32A 4 pole MCCB -05Nos,32A 2 pole MCB -03Nos, 20A 2pole MCB -03Nos Indication lampR,Y,B (LED). MCCB of rated current>100A will be 70-100% adjustablesetting and 25kA breaking current capacity and 10KA for lesser ratedcurrent. LT Panel shall be manufactured in Confirming to IS-60947 and IS/IEC 61439 Part-1,Part-2, Part-3 complete in all respect. | — | 1.00 | — | — | |
| — | — | — | 1,587.9 | ||
| Supply, installation, testing & energisation of 10 watt LED tube light fitting with 3 year warranty with required size of clamp etc complete in all respect. | — | 10.00 | — | — | |
| — | — | — | 1,64,051.8 | ||
| Supply,Installing, testing & commissioning of 1200 mm sweep,5 star rated BLDC ceiling fanas per IS:374/2019 or latest in White Colourwith 3 blade,speed control compatiable to electronic regulator, input power 28W, bressless DC moter, Blade material aluminium, double ballbearing, 5 year warranty, 300 mm down rodcompete in all respect. | — | 44.00 | — | — | |
| — | — | — | 11,121.58 | ||
| Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc as required | — | 214.00 | — | — | |
| — | — | — | 73,322.1 | ||
| Supply, fabrication, installation, testing & commissioning of outdoor type bus-bar chamber made of 2 mm thick cold rolled steel sheet, 500mmx300mmx 150mm size Bus-bar chamber, comprising of 125 A ,4 Pole MCCB and alumn Bus-bar cross section (25mmx5mm) fixed on bus-bar insulator with top cover fixed with hinged & locking arrangement complete with red oxide primer & final painting with metal grey enameled paint, complete in all respect. Box framing will be done by 40mmx40mmx3mm angle iron. | — | 9.00 | — | — | |
| — | — | — | 315 | ||
| Supply & fixing of Blank switch on already fix switch board | — | 35.00 | — | — | |
| — | — | — | 6,064 | ||
| Supply & fixing of 40 x 2 mm MS flat etc complete in all respect. | — | 64.00 | — | — | |
| — | — | — | 939.4 | ||
| Supply and laying of PVC flexible pipe 25 mm dia including suitable fixing by MS flat clamp etc. from feeding point. | — | 70.00 | — | — | |
| — | — | — | 11,953.44 | ||
| Supply and fixinf of single arm bracket 1.0 meter long for supports of LED light with suitable size of cap. Complete in all respect. | — | 12.00 | — | — | |
| — | — | — | 44,831.04 | ||
| Cutting of CC work for road/wall etc & covering/plastering of cutted CC work under or side of road/wall by cement & sand mortal after laying of cable/fixing of pole/laying of CI pipe/GI pipe/wiring or for making new cable trenchwork Complete in all respect. | — | 32.00 | — | — | |
| — | — | — | 12,539.12 | ||
| Supply and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. | — | 44.00 | — | — | |
| — | — | — | 16,887.12 | ||
| Provision & supply of Timer based semi automatic light control Panel Board consisting with 16 A,4 Pole MCB-5Nos + 16A, contact rating digital timer-2 nos+16 A,4 Pole Contactors-2 nos with 1 feet x 2 feet size with Din rail, CRCA Sheet Powder coated box complete. | — | 2.00 | — | — |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
TDOT-22-202523-03-2026Rev.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .