Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.8 CrAccepted-AOC S NO 50 8 MAMTA SOCIETY VADGAONSHERI BEHIND AYYAPPA TEMPLE PUNE 411014 | PUNE | PUNE | MAHARASHTRA | 411014 | ₹1.8 Cr Quoted ₹1.9 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹1.9 Cr+₹3.4 L (1.84%)Rejected-Finance | ₹1.9 Cr+₹3.4 L (1.84%) | L2 | Rejected-Finance Other than L1 |
| 3 | L3₹1.9 Cr+₹6.8 L (3.64%)Rejected-Finance | ₹1.9 Cr+₹6.8 L (3.64%) | L3 | Rejected-Finance Other than L1 |
| 4 | L4₹2.0 Cr+₹8.0 L (4.25%)Rejected-Finance 67 KAILASH VIHAR TIWARIPUR BAGIA JAJMAU KANPUR 208010 | KANPUR | KANPUR NAGAR | UTTAR PRADESH | 208010 | ₹2.0 Cr+₹8.0 L (4.25%) | L4 | Rejected-Finance Other than L1 |
| 5 | L5₹2.0 Cr+₹10.2 L (5.42%)Rejected-Finance 1630 SECTOR 7C CHANDIGARH 160019 | CHANDIGARH | CHANDIGARH | CHANDIGARH | 160019 | ₹2.0 Cr+₹10.2 L (5.42%) | L5 | Rejected-Finance Other than L1 |
Tender Value
₹2.4 Cr
EMD Value
₹3.1 L
Closing Date
18 Jan 2023, 6:00 pmClosed
Chief Engineer Pune Zone
Chief Engineer Pune Zone Dakshin Kaman Marg CAMP, Pune PIN- 411001
CONVERSION OF ALL OVERHEAD HT AND LT ELECTRICITY LINES TO UG CABLE AT GOA.
2022_MES_570069_1
CA NO CEPZ/MUM/TOKEN-13 OF 2022-23
Open Tender
Civil Works
Item Rate
365 days
Panaji
Class B Category b(ii)
Also refer NIT
8 documents required · 8 mandatory
₹2,000
GE Panaji Goa
₹3.1 L
Yes
3 Mar 2023
19 Dec 2022
20 Jan 2023
19 Dec 2022
18 Jan 2023
11 Jan 2023
20 Dec 2022 - 2 Jan 2023
Amount
Dismantling and taking down of ACSR or ACC conductors of any type or size and at any location all as specified and directed.
Dismantling of GI earth or Guard wires of any size all as specified and directed.
Dismantling & taking down of existing old cross arms made out of MS channels, angles including GI clamps, nuts, bolts etc. complete all as specified and directed.
Dismantling insulators any type, any size all as directed.
Dismantling of existing stay assembly of any size and type from its position carefully including demolition of concrete in coping and foundation of stay assembly including all necessary excavation and earthwork complete all as specified and as directed.
Taking down old unserviceable LT UG cables of any size complete all as specified and as directed.
Excavating in post holes (or similar holes) each n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, in Hard/ Dense soil complete all as specified and as directed.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for removing/ laying cables/pipes, erecting poles / stays and struts etc. and getting out in hard / dense soil including trimming sides and forming bottom surface all as specified and directed.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for removing/ laying cables/pipes, erecting poles / stays and struts etc. and getting out in soft disintegrated rock including trimming sides and forming bottom surface all as specified and directed.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for removing/ laying cables/pipes, erecting poles / stays and struts etc. and getting out in hard rock including trimming sides and forming bottom surface all as specified and directed.
Excavation in trenches not exceeding 1.5 m wide and depth exc 1.5m but not exceeding 3.0m for removing/ laying cables/pipes, erecting poles / stays and struts etc. and getting out in hard rock including trimming sides and forming bottom surface all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm using excavated hard/ dense soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm using excavated soft disintegrated rock complete all as specified and directed.
Removing excavated materials to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 m above the starting point for rock including spreading in low lying area and levelling all as specified and directed.
Supply only chain link MS Galvanized fencing 50 mm mesh, dia of wire 5mm all as specified and directed.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire complete all as specified and directed.
M&L for Hardcore of broken stones or boulders of gauge n exc. 63mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L for Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed.
M&L Plain cement concrete (1:4:8) type D2 using 40 mm graded coarse aggregate for foundation, filling and mass concrete etc. complete all as specified and directed.
M&L Plain cement concrete (1:2:4) type B1 using 20 mm graded coarse aggregate in roof kerbs or mud stops, rounded or chamfered on edges complete all as specified and directed.
M&L Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and directed.
M&L Machine pressed precast concrete interlocking paver blocks any shape and size conforming to IS 15658-2006 of 80 mm thickness M-40 Grade complete all as specified and directed.
M&L Rendering 10mm thick in cement mortar 1:4 on fair faces of brick work, finishing surfaces even and smooth without using extra cement complete all as specified and directed.
M&L Screed bed or bedding layer of mortar 15 mm thick in cement mortar 1:6 for laying floor finishes complete all as specified and directed.
Supplying, laying, connecting, testing and commissioning XLPE insulated PVC bedded galvanized steel strip or wire armoured, electric power cable, 1100 volts grade, heavy duty with stranded aluminium conductor, conforming to IS 7098 (Part-I) laid in cable trenches/ ducts/ wall/ surfaces/ pipe including compression gland, lugs, as required at site compllete all as specified and directed of following sizes:-
(a) 10 Sqmm 2 Core
(b) 10 Sqmm 4 Core
(c) 16 Sqmm 2 Core
(d) 16 Sqmm 4 Core
(e) 25 Sqmm 2 Core
(f) 25 Sqmm 3.5/ 4 Core
(g) 35 Sqmm 3.5 Core
(h) 50 Sqmm 3.5 Core
(j) 70 Sqmm 3.5 Core
(k) 120 Sqmm 3.5 Core
(l) 185 Sqmm 3.5 Core
(m) 240 Sqmm 3.5 Core
Supplying, laying, connecting, testing and commissioning XLPE insulated, screened PVC bedded galvanized steel strip or wire armoured, electric power earthed cable, 6.35/11 KV (E) grade, heavy duty with stranded aluminium conductor of size 95 Sqmm 3 core, conforming to IS 7098 (Part-II) laid in cable trenches/ ducts/ wall/ surfaces/ pipe including compression gland, lugs, as required at site compllete all as specified and directed.
NOTES for Item Nos. 25 (25.01 to 25.12) & 26: (a) Pre-despatch inspection and testing shall be done by the officer detailed by Accepting Officer. All testing shall be performed as per relevant IS. (b) Testing for IR and continuity shall be recorded before and after laying of cable. (c) Suitable glands and aluminium lugs for end termination of cable shall be provided by the contractor without any extra cost to the department. (d) Straight through joints be permitted only after approval by GE without any extra cost to department. Cable shall be ordered after physical measurement on ground. (e) Excavation, earthwork, sand, cable protection covers and GI pipe required shall be measured and paid separately under respective items of schedule. (f) Cable shall be laid in trenches/ fixed to MS structural bracket including clamps, gland, lugs etc.
S & F danger notice plate for HT of size 25 cm x 20 cm and 1.6 mm thick mild steel sheet, vitreous enamelled white with letters, figures and conventional skull and bones and written with words "DANGER 11 KV" in English, Hindi & Marathi in signal red colour and fixed with MS clamps bolts and nuts of approved size, complete all as specified and directed.
M&L for river sand cushioning (dry) in trenches for protection of UG cable (below, above and around the UG cable laid in trenches) of 23 cm spread thickness (8cm in depth before laying the cable and 15cm in depth after laying the cable) and consolidated (punned) upto 18mm thickness complete all as specified and as directed. Note:- Only punned thickness of sand shall be considered for measurement purposes.
Supplying and fixing burnt bricks sub class B laid breadth-wise along the length of cable laid in trenches over sand cushion laid for protection of cable all as specified and as directed.
Supplying and laying factory made unreinforced precast concrete cable cover ISI marked, class HV, type 1, flat size 300 mm x 180 mm x 40 mm M-20 grade concrete duly embossed with "HT CABLE 11 KV", laid lengthwise perpendicular to the axis of cable complete all as specified and as directed.
S&F GI tubing light grade for protection of cable fixed in wall or laid in trenches, suitable for following sizes:-
(a) 100 mm bore
(b) 80 mm bore
(c) 50 mm bore
(d) 40 mm bore
Supply, install and erect in true vertical position steel tubular swaged welded poles complete with MS base plate 6 mm thick and of size 300 mm x 300mm, finial taper, pole cap, MS bolts, nuts & screws etc., pole made out of ERW M.S. tubing conforming to IS-2713 Part-II type 410 SP- 55 (11.0 meters long) HT including holes of required numbers and size for fixing of cross arms and applying two coats of aluminium paint over a coat of red oxide primer over the exposed surface and applying two coats of black bituminous paint over the embedded portion of pole in concrete, painting three signal red colour bands at lower portion of exposed pole starting from pole cap each band of 300 mm height at 300 mm spacing, painting pole number by black paint in stencilled letters/figures of 8 cm height, complete all as specified and directed. (Note:- Excavation and PCC for foundation and coping will be measured & paid separately under relevant items of BOQ).
M&L Cross arms, bracing, supports, clamps, back plates, hooks etc, fabricated from structural steel sections ( M.S. Channels, angle sections, flat, round or square bars etc) of required sizes and shapes, including bolts, nuts and washers, welding, bending, cutting cold or hot, drilling holes for inserting bolts, in any shape or size, as indicated or directed complete including painting with one red oxide primer coat, two coats of aluminium paint complete all as specified and directed.
S&F HT 11 KV outdoor non-linear type lightening arrestor with mountings, accessories, complete fixed on cross arms of two pole structure/ GI flat strip and connect with same size of ACSR conductor encased in PVC alkathene pipe with all fittings connected to earth strip with nut, bolt, washer transmission class discharge capacity of 10 kilo amps and suitable for working pressure 9 KV RMS complete all as specified and directed by Engineer-in-Charge.
Supply and fix Gang operated air break switch off load disconnecting switch 11 KV, 200 Amps with 12 insulators, triple pole, each pole consisting of galvanised steel base HT insulator as per BSS/ISS non-ferrous knife and spring loaded contacts, arching arms of adequate section to break magnetising current complete with square shaft of Gl, adequate length for Phase separation, operating handle complete with locking arrangement with lock and key in both "OFF" and "ON" position, with suitable clamp, nuts, bolts complete for fixing on the channel, making all electric connections / Jumpers with botlle lugs commissioning and testing complete alongwith Supply and fix new drop out expulsion fuse HT 11 KV grade rating up to 50 Amps mounted on insulator and steel frame complete all heavy fuse barrel with fuse element complete set conforming to IS: 1818 as specified and as directed by Engineer - in - Charge. Make: Jaipuria brothers/ ATLAS/ PACTIL or equivalent make as given in Appendix 'C'.
M&L for PCC 1:3:6 type C2 using 40mm graded stone aggregate for foundation of poles/ struts/ PCC platform etc. complete all as specified and directed.
M&L for PCC (1:4:8) type D2 using 40 mm graded coarse aggregate for pedestal of poles, all including necessary formwork, fair finishing to the exposed surfaces using extra cement complete all as specified and directed.
M & L Pin type insulator, porcelain, vitreous brown or green including one galvanised mild steel spindle, two galvanised iron washer and one GI nut, 150mm height and 150mm dia for 11KV grade complete all as specified and directed.
M & L Disc insulator, porcelain, vitreous 150mm high and 150mm dia ball and socket type, white, brown or green two in series assembly for tension with tension clamps for conductors working pressure 11KV including galvanised steel fittings complete all as specified and directed.
M & L for Anti-climbing device; spikes type fabricated out of MS bars (round, square or flat), 12mm dia round bar made out of 40 x 6mm MS flat including nuts, bolts, washers and welding in two halves made to shape to suit the cross section of the pole spike welded to flat iron bolts, nuts, washers including one primer coat, one under coat and two finishing coats of silver aluminium paint including preparation of surfaces complete all as specified and directed.
M & L for aluminium conductor steel reinforced of adequate size not less than weasel for HT overhead line on PCC pole, stretching without kinks ad bends including winding wire complete all as specified and directed.
S&F weather proof hot press SMC street light junction box of size 250 x 250 x 155 mm depth including MCB SP 6 Amps and connecting terminal 4-way of suitable current rating and fixing with street light poles (steel) using necessary MS clamps, nuts, bolts, washers etc of suitable size all as specified and directed.
M & L for Disconnecting/ dismantling in position of 11 KV distribution transformers & Shifting of Spare Transformer of any capacity up to 400 KVA from 3 TTR substation to new Substation by using crane and necessary connections from both HT/ LT cables all as specified and directed. Note: Trasportation for shifting to the required site and required T&P like crane etc are to be arranged by contractor and rate for the same shall be deemed to be included in the item.
M&L Boring of holes under roads/railway crossing, pavement, hard standing by trenchless technology adopting HDD technology in normal/ hard/ rock soil with minimum 8 inches bore and using ultra sound technique and necessary machine including HDPE pipe of 110 mm dia suitable for 0.4 MPa working pressure without any damage to existing structure and making good to match with the adjoining surfaces/structure including bentonite shall be put external around the cable with HDPE pipe as per cable laid complete all as specified and directed.
Supply and spreading stone aggregates of 40 mm size at/ around Electrical outdoor installation yard, 11 KV substation, near DP structure etc. complete all as specified and directed. (Note:- Measurement shall be stack measurement when the stone aggregates are brought at site)
Design, Fabrication, Supply, Erecting, Connecting and Testing totally enclosed LT cubicle panel board 3 Phase 4 wire system outdoor double door front and back opening type, sloped canopy (Hood) on top extended 100 mm all around, separate compartment for each control gear, cable alley, provision of knock out type plates for various sizes of cables in and out, incoming and out going feeders duly marked on rivetted plates etc complete, CPRI approved factory made fabricated out of 3mm thick CRCA sheet duly treated through 7 tank pre treatment process and painted with epoxy powder coated matt finish of SIEMENS GREY structural RAL 7032 shade colour, built in industrial type locking arrangement on front and back, and pre wired with PVC insulated multi stranded copper conductor for controls and monitors, PVC sleeved aluminium strip for connecting MCCBs, Panel mounted on Angle iron frame of sutable size duly painted and embedded in PCC 1:3:6 45cm below ground level and 15cm above ground level and consisting of following complete all as specified and directed (Feeder Pillar No-01 at 64 Hav S/Stn area): -
Bus Bar Chamber: Electrically grade Bus bar aluminium of capacity equal to 1.5 times of rated incoming conirol switch gear including interconnection of all switch gears duly insulated with colour coded heat shrinkable sleeve and mounted on suitable size of 'F' class insulators made of non hygroscopic, non combustible, track resistant high strength FRP insulators for phases and neutral set of 4 for RYB & N -01 set
Incoming
(a) MCCB, 4 pole, 415 Volts 50 Hz 630 Amps adjustable type with rupturing capacity of 50KA - 01 No
(b) Multifunction meter to read V, A, Hz etc - 01 No
(c) Indicator LED type for RYB set of 03 - 01 Set
Outgoing
(a) MCCB, 4 pole, 415 Volts 50 Hz 25 Amps rupturing capacity 16KA - 10 Nos
(b) MCCB, 4 pole, 415 Volts 50 Hz 40 Amps rupturing capacity 16KA - 04 Nos
(c) MCB DP, 230 Volts 50 Hz 20 Amps rupturing capacity 10KA - 01 No
(d) MCB DP, 230 Volts 50 Hz 16 Amps rupturing capacity 10KA - 01 No
(e) Digital Astro timeswitch 8A, 240 V AC of Make L&T Model No T2DDT7 or equivalent make approved by GE - 01 No
(f) 3 pole power contactor 25A, coil voltage 240 V AC of Make L&T ML1.5 Cat No. SS91851/Siemens/Schneider or equivalent make approved by GE. - 01 No
Design, Fabrication, Supply, Erecting, Connecting and Testing totally enclosed LT cubicle panel board 3 Phase 4 wire system outdoor double door front and back opening type, sloped canopy (Hood) on top extended 100 mm all around, separate compartment for each control gear, cable alley, provision of knock out type plates for various sizes of cables in and out, incoming and out going feeders duly marked on rivetted plates etc complete, CPRI approved factory made fabricated out of 3mm thick CRCA sheet duly treated through 7 tank pre treatment process and painted with epoxy powder coated matt finish of SIEMENS GREY structural RAL 7032 shade colour, built in industrial type locking arrangement on front and back, and pre wired with PVC insulated multi stranded copper conductor for controls and monitors, PVC sleeved aluminium strip for connecting MCCBs, Panel mounted on Angle iron frame of sutable size duly painted and embedded in PCC 1:3:6 45cm below ground level and 15cm above ground level and consisting of following complete all as specified and directed (Feeder Pillar No-02 at JCO's Accn area): -
Bus Bar Chamber: Electrically grade Bus bar aluminium of capacity equal to 1.5 times of rated incoming conirol switch gear including interconnection of all switch gears duly insulated with colour coded heat shrinkable sleeve and mounted on suitable size of 'F' class insulators made of non hygroscopic, non combustible, track resistant high strength FRP insulators for phases and neutral set of 4 for RYB & N -01 set
Multifunction meter to read V, A, Hz etc - 01 No
Indicator LED type for RYB set of 03 - 01 Set
Incoming
(a) MCCB, 4 pole, 415 Volts 50 Hz 250 Amps adjustable type with rupturing capacity of 36KA - 01 No
Outgoing
(a) MCCB, 4 pole, 415 Volts 50 Hz 25 Amps rupturing capacity 16KA - 02 Nos
(b) MCCB, 4 pole, 415 Volts 50 Hz 40 Amps rupturing capacity 16KA - 18 Nos
(c) MCB DP, 230 Volts 50 Hz 16 Amps rupturing capacity 10KA - 01 No
(d) Digital Astro Timeswitch 8A, 240 V AC of Make L&T Model No T2DDT7 or equivalent make approved by GE - 01 No
(e) 3 pole power contactor 25A, coil voltage 240 V AC of Make L&T ML1.5 Cat No. SS91851/Siemens/Schneider or equivalent make approved by GE. - 01 No
Design, Fabrication, Supply, Erecting, Connecting and Testing totally enclosed LT cubicle panel board 3 Phase 4 wire system outdoor double door front and back opening type, sloped canopy (Hood) on top extended 100 mm all around, separate compartment for each control gear, cable alley, provision of knock out type plates for various sizes of cables in and out, incoming and out going feeders duly marked on rivetted plates etc complete, CPRI approved factory made fabricated out of 3mm thick CRCA sheet duly treated through 7 tank pre treatment process and painted with epoxy powder coated matt finish of SIEMENS GREY structural RAL 7032 shade colour, built in industrial type locking arrangement on front and back, and pre wired with PVC insulated multi stranded copper conductor for controls and monitors, PVC sleeved aluminium strip for connecting MCCBs, Panel mounted on Angle iron frame of suitable size duly painted and embedded in PCC 1:3:6 45cm below ground level and 15cm above ground level including taking down old unserviceable LT panel and consisting of following complete all as specified and directed (Feeder Pillar No-03 at 3 TTR New Substation): -
Bus Bar Chamber: Electrically grade Bus bar aluminium of capacity equal to 1.5 times of rated incoming conirol switch gear including interconnection of all switch gears duly insulated with colour coded heat shrinkable sleeve and mounted on suitable size of 'F' class insulators made of non hygroscopic, non combustible, track resistant high strength FRP insulators for phases and neutral set of 4 for RYB & N -01 set
Multifunction meter to read V, A, Hz etc - 01 No
Indicator LED type for RYB set of 03 - 01 Set
Incoming
(a) MCCB, 4 pole, 415 Volts 50 Hz 125 Amps adjustable type with rupturing capacity of 25KA - 01 No
Outgoing
(a) MCCB, 2 pole, 415 Volts, 50 Hz, 25 Amps rupturing capacity 16KA - 13 Nos
(b) MCCB, 4 pole, 415 Volts 50 Hz 16 Amps rupturing capacity 16KA - 02 Nos
(c) MCB DP, 230 Volts 50 Hz, 16 Amps rupturing capacity 10KA - 01 No
(d) Digital Astro Timeswitch 8A, 240 V AC of Make L&T Model No T2DDT7 or equivalent make approved by GE - 01 No
(e) 3 pole power contactor 25A, coil voltage 240 V AC of Make L&T ML1.5 Cat No. SS91851/Siemens/Schneider or equivalent make approved by GE. - 01 No
Design, Fabrication, Supply, Erecting, Connecting and Testing totally enclosed LT cubicle panel board 3 Phase 4 wire system outdoor double door front and back opening type, sloped canopy (Hood) on top extended 100 mm all around, separate compartment for each control gear, cable alley, provision of knock out type plates for various sizes of cables in and out, incoming and out going feeders duly marked on rivetted plates etc complete, CPRI approved factory made fabricated out of 3mm thick CRCA sheet duly treated through 7 tank pre treatment process and painted with epoxy powder coated matt finish of SIEMENS GREY structural RAL 7032 shade colour, built in industrial type locking arrangement on front and back, and pre wired with PVC insulated multi stranded copper conductor for controls and monitors, PVC sleeved aluminium strip for connecting MCCBs, Panel mounted on Angle iron frame of suitable size duly painted and embedded in PCC 1:3:6 45cm below ground level and 15cm above ground level and consisting of following complete all as specified and directed (Feeder Pillar No-04 at 3 TTR New Substation): -
Bus Bar Chamber: Electrically grade Bus bar aluminium of capacity equal to 1.5 times of rated incoming conirol switch gear including interconnection of all switch gears duly insulated with colour coded heat shrinkable sleeve and mounted on suitable size of 'F' class insulators made of non hygroscopic, non combustible, track resistant high strength FRP insulators for phases and neutral set of 4 for RYB & N -01 set
Multifunction meter to read V, A, Hz etc - 01 No
Indicator LED type for RYB set of 03 - 01 Set
Incoming
(a) MCCB, 4 pole, 415 Volts 50 Hz 200 Amps adjustable type with rupturing capacity of 35KA - 01 No
Outgoing
(a) MCCB, 2 pole, 415 Volts, 50 Hz, 25 Amps rupturing capacity 16KA - 20 Nos
(b) MCCB, 4 pole, 415 Volts 50 Hz 25 Amps rupturing capacity 16KA - 04 Nos
(c) MCB DP, 230 Volts 50 Hz, 16 Amps rupturing capacity 10KA - 01 No
(d) Digital Astro Timeswitch 8A, 240 V AC of Make L&T Model No T2DDT7 or equivalent make approved by GE - 01 No
(e) 3 pole power contactor 25A, coil voltage 240 V AC of Make L&T ML1.5 Cat No. SS91851/Siemens/Schneider or equivalent make approved by GE. - 01 No
Design, Fabrication, Supply, Erecting, Connecting and Testing totally enclosed LT cubicle panel board 3 Phase 4 wire system outdoor double door front and back opening type, sloped canopy (Hood) on top extended 100 mm all around, separate compartment for each control gear, cable alley, provision of knock out type plates for various sizes of cables in and out, incoming and out going feeders duly marked on rivetted plates etc complete, CPRI approved factory made fabricated out of 3mm thick CRCA sheet duly treated through 7 tank pre treatment process and painted with epoxy powder coated matt finish of SIEMENS GREY structural RAL 7032 shade colour, built in industrial type locking arrangement on front and back, and pre wired with PVC insulated multi stranded copper conductor for controls and monitors, PVC sleeved aluminium strip for connecting MCCBs, Panel mounted on Angle iron frame of suitable size duly painted and embedded in PCC 1:3:6 45cm below ground level and 15cm above ground level and consisting of following complete all as specified and directed (Feeder Pillar No-05 at 5 TTR Md Accn Main Power House Feeder): -
Bus Bar Chamber: Electrically grade Bus bar aluminium of capacity equal to 1.5 times of rated incoming conirol switch gear including interconnection of all switch gears duly insulated with colour coded heat shrinkable sleeve and mounted on suitable size of 'F' class insulators made of non hygroscopic, non combustible, track resistant high strength FRP insulators for phases and neutral set of 4 for RYB & N -01 set
Multifunction meter to read V, A, Hz etc - 01 No
Indicator LED type for RYB set of 03 - 01 Set
Incoming
(a) MCCB, 4 pole, 415 Volts 50 Hz 100 Amps adjustable type with rupturing capacity of 25KA - 01 No
Outgoing
(a) MCCB, 2 pole, 415 Volts, 50 Hz, 16 Amps rupturing capacity 25KA - 07 Nos
(b) MCCB, 2 pole, 415 Volts 50 Hz, 25 Amps rupturing capacity 25KA - 02 Nos
(c) MCCB, 2 pole, 415 Volts 50 Hz, 32 Amps rupturing capacity 25KA - 02 Nos
(d) MCCB, 4 pole, 415 Volts 50 Hz, 25 Amps rupturing capacity 16KA - 01 No
(e) MCB DP, 230 Volts 50 Hz, 16 Amps rupturing capacity 10KA - 01 No
(f) Digital Astro Timeswitch 8A, 240 V AC of Make L&T Model No T2DDT7 or equivalent make approved by GE - 01 No
(g) 3 pole power contactor 25A, coil voltage 240 V AC of Make L&T ML1.5 Cat No. SS91851/Siemens/Schneider or equivalent make approved by GE. - 01 No
Design, Fabrication, Supply, Erecting, Connecting and Testing totally enclosed LT cubicle panel board 3 Phase 4 wire system outdoor double door front and back opening type, sloped canopy (Hood) on top extended 100 mm all around, separate compartment for each control gear, cable alley, provision of knock out type plates for various sizes of cables in and out, incoming and out going feeders duly marked on rivetted plates etc complete, CPRI approved factory made fabricated out of 3mm thick CRCA sheet duly treated through 7 tank pre treatment process and painted with epoxy powder coated matt finish of SIEMENS GREY structural RAL 7032 shade colour, built in industrial type locking arrangement on front and back, and pre wired with PVC insulated multi stranded copper conductor for controls and monitors, PVC sleeved aluminium strip for connecting MCCBs, Panel mounted on Angle iron frame of suitable size duly painted and embedded in PCC 1:3:6 45cm below ground level and 15cm above ground level and consisting of following complete all as specified and directed (Feeder Pillar No-06 at 3/5 TTR OTM Accn Main Power House Feeder): -
Bus Bar Chamber: Electrically grade Bus bar aluminium of capacity equal to 1.5 times of rated incoming conirol switch gear including interconnection of all switch gears duly insulated with colour coded heat shrinkable sleeve and mounted on suitable size of 'F' class insulators made of non hygroscopic, non combustible, track resistant high strength FRP insulators for phases and neutral set of 4 for RYB & N -01 set
Multifunction meter to read V, A, Hz etc - 01 No
Indicator LED type for RYB set of 03 - 01 Set
Incoming
(a) MCCB, 4 pole, 415 Volts 50 Hz 160 Amps adjustable type with rupturing capacity of 35KA - 01 No
Outgoing
(a) MCCB, 2 pole, 415 Volts, 50 Hz, 16 Amps rupturing capacity 25KA - 01 No
(b) MCCB, 2 pole, 415 Volts 50 Hz, 25 Amps rupturing capacity 25KA - 01 No
(c) MCCB, 4 pole, 415 Volts 50 Hz, 25 Amps rupturing capacity 16KA - 11 Nos
(d) MCB DP, 230 Volts 50 Hz, 16 Amps rupturing capacity 10KA - 01 No
(e) Digital Astro Timeswitch 8A, 240 V AC of Make L&T Model No T2DDT7 or equivalent make approved by GE - 01 No
(f) 3 pole power contactor 25A, coil voltage 240 V AC of Make L&T ML1.5 Cat No. SS91851/Siemens/Schneider or equivalent make approved by GE. - 01 No
Design, Fabrication, Supply, Erecting, Connecting and Testing totally enclosed LT cubicle panel board 3 Phase 4 wire system outdoor double door front and back opening type, sloped canopy (Hood) on top extended 100 mm all around, separate compartment for each control gear, cable alley, provision of knock out type plates for various sizes of cables in and out, incoming and out going feeders duly marked on rivetted plates etc complete, CPRI approved factory made fabricated out of 3mm thick CRCA sheet duly treated through 7 tank pre treatment process and painted with epoxy powder coated matt finish of SIEMENS GREY structural RAL 7032 shade colour, built in industrial type locking arrangement on front and back, and pre wired with PVC insulated multi stranded copper conductor for controls and monitors, PVC sleeved aluminium strip for connecting MCCBs, Panel mounted on Angle iron frame of suitable size duly painted and embedded in PCC 1:3:6 45cm below ground level and 15cm above ground level and consisting of following complete all as specified and directed (Feeder Pillar No-07 at 3/5 MT Coy New S/Stn feeder) :-
Bus Bar Chamber: Electrically grade Bus bar aluminium of capacity equal to 1.5 times of rated incoming conirol switch gear including interconnection of all switch gears duly insulated with colour coded heat shrinkable sleeve and mounted on suitable size of 'F' class insulators made of non hygroscopic, non combustible, track resistant high strength FRP insulators for phases and neutral set of 4 for RYB & N -01 set
Incoming
(a) MCCB, 4 pole, 415 Volts 50 Hz 160 Amps adjustable type with rupturing capacity of 35KA - 01 No
(b) Multifunction meter to read V, A, Hz etc - 01 No
(c) Indicator LED type for RYB set of 03 - 01 Set
Outgoing
(a) MCCB, 2 pole, 415 Volts, 50 Hz, 25 Amps rupturing capacity 25KA - 20 Nos
(b) MCCB, 4 pole, 415 Volts 50 Hz, 16 Amps rupturing capacity 16KA - 01 No
(c) MCB DP, 230 Volts 50 Hz, 16 Amps rupturing capacity 10KA - 01 No
(d) Digital Astro Timeswitch 8A, 240 V AC of Make L&T Model No T2DDT7 or equivalent make approved by GE - 01 No
(e) 3 pole power contactor 25A, coil voltage 240 V AC of Make L&T ML1.5 Cat No. SS91851/Siemens/Schneider or equivalent make approved by GE. - 01 No
Design, Fabrication, Supply, Erecting, Connecting and Testing totally enclosed LT cubicle panel board 3 Phase 4 wire system outdoor double door front and back opening type, sloped canopy (Hood) on top extended 100 mm all around, separate compartment for each control gear, cable alley, provision of knock out type plates for various sizes of cables in and out, incoming and out going feeders duly marked on rivetted plates etc complete, CPRI approved factory made fabricated out of 3mm thick CRCA sheet duly treated through 7 tank pre treatment process and painted with epoxy powder coated matt finish of SIEMENS GREY structural RAL 7032 shade colour, built in industrial type locking arrangement on front and back, and pre wired with PVC insulated multi stranded copper conductor for controls and monitors, PVC sleeved aluminium strip for connecting MCCBs, Panel mounted on Angle iron frame of suitable size duly painted and embedded in PCC 1:3:6 45cm below ground level and 15cm above ground level and consisting of following complete all as specified and directed (Feeder Pillar No-08 at 5 TTR Md Accn New S/Stn feeder) :-
Bus Bar Chamber: Electrically grade Bus bar aluminium of capacity equal to 1.5 times of rated incoming conirol switch gear including interconnection of all switch gears duly insulated with colour coded heat shrinkable sleeve and mounted on suitable size of 'F' class insulators made of non hygroscopic, non combustible, track resistant high strength FRP insulators for phases and neutral set of 4 for RYB & N -01 set
Incoming
(a) MCCB, 4 pole, 415 Volts 50 Hz 250 Amps adjustable type with rupturing capacity of 36KA - 01 No
(b) Multifunction meter to read V, A, Hz etc - 01 No
(c) Indicator LED type for RYB set of 03 - 01 Set
Outgoing
(a) MCCB, 2 pole, 415 Volts, 50 Hz, 16 Amps rupturing capacity 25KA - 02 Nos
(b) MCCB, 4 pole, 415 Volts 50 Hz, 16 Amps rupturing capacity 16KA - 14 Nos
(c) MCCB, 4 pole, 415 Volts 50 Hz, 25 Amps rupturing capacity 16KA - 03 Nos
(d) MCCB, 4 pole, 415 Volts 50 Hz, 40 Amps rupturing capacity 16KA - 01 No
(e) MCB DP, 230 Volts 50 Hz, 16 Amps rupturing capacity 10KA - 01 No
(f) Digital Astro Timeswitch 8A, 240 V AC of Make L&T Model No T2DDT7 or equivalent make approved by GE - 01 No
(g) 3 pole power contactor 25A, coil voltage 240 V AC of Make L&T ML1.5 Cat No. SS91851/Siemens/Schneider or equivalent make approved by GE. - 01 No
Design, Fabrication, Supply, Erecting, Connecting and Testing totally enclosed LT cubicle panel board 3 Phase 4 wire system outdoor double door front and back opening type, sloped canopy (Hood) on top extended 100 mm all around, separate compartment for each control gear, cable alley, provision of knock out type plates for various sizes of cables in and out, incoming and out going feeders duly marked on rivetted plates etc complete, CPRI approved factory made fabricated out of 3mm thick CRCA sheet duly treated through 7 tank pre treatment process and painted with epoxy powder coated matt finish of SIEMENS GREY structural RAL 7032 shade colour, built in industrial type locking arrangement on front and back, and pre wired with PVC insulated multi stranded copper conductor for controls and monitors, PVC sleeved aluminium strip for connecting MCCBs, Panel mounted on Angle iron frame of suitable size duly painted and embedded in PCC 1:3:6 45cm below ground level and 15cm above ground level and consisting of following complete all as specified and directed including taking down old LT Panel board at 64 Hav S/Stn (Main LT Panel at 64 Hav Substation for 400 KVA TFR) :-
Bus Bar Chamber: Electrically grade Bus bar aluminium of capacity equal to 1.5 times of rated incoming conirol switch gear including interconnection of all switch gears duly insulated with colour coded heat shrinkable sleeve and mounted on suitable size of 'F' class insulators made of non hygroscopic, non combustible, track resistant high strength FRP insulators for phases and neutral set of 4 for RYB & N -01 set
Incoming
(a) ACB, 4 pole, 415 Volts with Thermal Magnetic Release (Manual fixed type) of capacity 800 Amps - 01 No
(b) Multifunction meter to read V, A, Hz etc - 01 No
(c) Indicator LED type for RYB set of 03 - 01 Set
Outgoing
(a) MCCB, 4 pole, 415 Volts, 50 Hz, 320 Amps adjustable type with rupturing capacity 25KA - 01 No
(b) MCCB, 4 pole, 415 Volts, 50 Hz, 250 Amps adjustable type with rupturing capacity 25KA - 01 No
(c) Provision of spare compartment for fixing of MCCB of capacity upto 200 Amps -01 No
Design, Fabrication, Supply, Erecting, Connecting and Testing totally enclosed LT cubicle panel board 3 Phase 4 wire system outdoor double door front and back opening type, sloped canopy (Hood) on top extended 100 mm all around, separate compartment for each control gear, cable alley, provision of knock out type plates for various sizes of cables in and out, incoming and out going feeders duly marked on rivetted plates etc complete, CPRI approved factory made fabricated out of 3mm thick CRCA sheet duly treated through 7 tank pre treatment process and painted with epoxy powder coated matt finish of SIEMENS GREY structural RAL 7032 shade colour, built in industrial type locking arrangement on front and back, and pre wired with PVC insulated multi stranded copper conductor for controls and monitors, PVC sleeved aluminium strip for connecting MCCBs, Panel mounted on Angle iron frame of suitable size duly painted and embedded in PCC 1:3:6 45cm below ground level and 15cm above ground level and consisting of following complete all as specified and directed (Main LT Panel at 3 TTR OTM Accn new S/Stn for 200 KVA) :-
Bus Bar Chamber: Electrically grade Bus bar aluminium of capacity equal to 1.5 times of rated incoming conirol switch gear including interconnection of all switch gears duly insulated with colour coded heat shrinkable sleeve and mounted on suitable size of 'F' class insulators made of non hygroscopic, non combustible, track resistant high strength FRP insulators for phases and neutral set of 4 for RYB & N -01 set
Incoming
(a) MCCB, 4 pole, 415 Volts, 50 Hz, 320 Amps rupturing capacity 36KA - 01 No
(b) Multifunction meter to read V, A, Hz etc - 01 No
(c) Indicator LED type for RYB set of 03 - 01 Set
Outgoing
(a) MCCB, 4 pole, 415 Volts, 50 Hz, 125 Amps, rupturing capacity 16KA - 01 No
(b) MCCB, 4 pole, 415 Volts, 50 Hz, 200 Amps, rupturing capacity 25KA - 01 No
(c) Provision of spare compartment for fixing of MCCB of capacity upto 200 Amps -01 No
Notes for item Nos. 46.00 to 55.00 :- (a) Panel manufacturer should have in house powder coating plant with minimum 8 tanks pretreatment of MS sheet facilities, dust free spray paint booth. (8 tanks pretreatment process includes: degreasing/ water rinsing/ de-rusting/ water rinsing/ activation/ phosphating/ water rinsing / passivation). (b) Thickness of powder coating shall not be less than 80 microns and test certificate for powder coating shall be furnished along with LT Panel. (c) Pre-dispatch inspection shall be carried out by the authorized representative of Accepting Officer. In case of any deviation from approved drawing, the same shall be rejected and fresh LT Panel shall be fabricated by the manufacturer. Testing shall be done at manufacturer's premises and all routine tests like IR and continuity tests shall be performed / recorded in presence of authorized representative of Accepting Officer. (d) All the electrical switchgears like MCCBs, MCBs and ACBs should be of same make.
M & L for cable jointing kit for 11 KV grade cable for outdoor termination, heat shrink type, joint complete with jointing material and accessories complete all as specified and directed suitable for 3 core XLPE, armoured aluminium conductor cable of size 95 Sqmm. Note: Rate quoted by the contractor is deemed to be inclusive of lugs, nuts, bolts and washers etc.
M & L for cable jointing kit for 11 KV grade cable for straight through, heat shrink type, joint complete with jointing material and accessories complete all as specified and directed suitable for 3 core XLPE, armoured aluminium conductor cable of size 95 Sqmm. Note: Rate quoted by the contractor is deemed to be inclusive of lugs, nuts, bolts and washers etc.
M&L for Earthing complete with galvanised steel earth plate electrode 600mm x 600mm x 6mm thick, buried vertically in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level surrounded from all sides by 15cm thick packed layer of charcoal dust and common salt in alternate layers, electrode connected to and including galvanised iron earth lead strip of size 32mm x 6mm upto 7.5 m from earthing by means of bolts, nuts and washers of galvanised iron or steel including necessary excavation and earth work in any type of soil, removal of surplus soil to a distance n. exc 50 m, PCC 1:3:6 type C-1 earth chamber of outer dimensions 54 cm x 54 cm x 30 cm and internal dimensions 30 cm x 30 cm x 30 cm with RCC 1:2:4 type B1cover of dimensions 54 x 54 x 10 cm reinforced with 6mm dia MS round bars and handle of 8mm dia MS bar and GI pipe 40 mm dia light grade with required fittings for protection of GI earth strip from earth plate to test point / plant / machineries buried in ground, laid under floors/ plinths or fixed on walls or concealed in walls etc; both to be provided to the extent as required at site, 20 mm dia GI pipe medium grade for watering arrangements with funnel internally secured with wire mesh all as shown in Electrical Plate No. 3 of SSR Part I 2009, complete all as specified and directed, including testing on completion.
Note for item No. 58.00 :- The quoted rate shall be deemed to include for protection pipe, GI water pipe, wire mesh, funnel, excavation, RCC pit cover, PCC, Test point, 32 x 6mm copper from top of earth plate upto 5m above ground level and if GI protection pipe is less than 5m, no price adjustment shall be made.
Supply and fix duly painted cable route marker made up of aluminium cast material 150mm dia Round plate of thickness 5 to 6 mm and round bar of 25 mm dia duly embossed on block of PCC of size 10x10 cm with Marking embossed letter of 3 mm thickness as HT Cable / LT Cable including necessary earthwork complete all as specified and directed at site by Engr-in-Charge.
M/s Prem Associates
N K BUILDERS
Ashirwad Contractor and Supplier
SAGGI ELECTRIC COMPANY
Priyanka Power line
Sant Construction Co.
Horizon Construction
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .