O/O EXECUTIVE ENGINEER WSS DIV NO. 1 JALANDHAR
O/O EXECUTIVE ENGINEER WSS DIV NO. 1 JALANDHAR
Providing and Installing of Air Conditioners RO and Water Cooler in official Premisses for Holding Sarkar Tuhade Dwar by Honble Chief Minister Punjab At Jalandhar Under Head 4215
2024_WSS_127091_1
04-GOVTWOKS-2024
Open Tender
Civil Works
Item Rate
20 days
Jalandhar
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
₹37,500
2 Dec 2024
12 Sept 2024
27 Sept 2024
12 Sept 2024
27 Sept 2024
12 Sept 2024
Amount
Air conditioner & Water Cooler & RO Etc.
Providing & Installing 5 Star split type wall mounted air conditioner capacity 2.0 tonne OGeneral / mitsubishi Heavy Duty make having cooling capacity 7040 watts, Rated ISEER5.22 KWH/KWH, Air Flow of 1500 cum per/hr , Ambient operating Temperature range 18 deg– 55 deg. With R32 refrigerant type, MCB arrangement for installing OD units on terrace including inlet and outlet copper tubes with proper insulation drainage arrangement cable link between ID unit and OD unit. stands for OD unit and concealing of copper pipes and drainage pipe within the building and installing charges complete in all respects.
Providing & Installing 5 Star Window air conditioner capacity 2.0 tonne OGeneral / mitsubishi Heavy Duty make having cooling capacity 6050 watts, Rated ISEER 3.18 KWH/KWH, Air Flow of 860 cum per/hr , Ambient operating Temperature range 18 deg– 50 deg. With R32 refrigerant type MCB arrangement for installing OD units on terrace including inlet and outlet copper tubes with proper insulation drainage arrangement cable link between ID unit and OD unit. stands for OD unit and concealing of copper pipes and drainage pipe within the building and installing charges complete in all respects.
Providing & Installing 1 Star Tower Air conditioner capacity 4.00 tonne Blue Star Fixed Speed make having cooling capacity 12896 watts, Rated ISEER 2.71 KWH/KWH, Air Flow of 877 cum per/hr , Ambient operating Temperature range 18 deg– 52 deg. With R32 refrigerant type with MCB arrangement for installing OD units on terrace including inlet and outlet copper tubes with proper insulation drainage arrangement cable link between ID unit and OD unit. stands for OD unit and concealing of copper pipes and drainage pipe within the building and installing charges complete in all respects.
Supplying & Installation for Extra hard soft copper refrigrant piping complete with all required fitting
Providing, laying, jointing, fixing and testing uPVC Pipe with G.I. specials as per ISI-4985, including cost of G.I. specials such as tees, bends, sockets, elbows etc. testing inside building complete.
Providing & fixing in position Water Cooler without Stablizer of approved make (to the approval of Engineer-in-charge ) including carriage complete in all respect.
Water Cooler Semi Steel Body 80/120 ltr Capacity without Stablizer
AUTOMATIC VOLTAGE STABLIZER:
Supply and erection of Single phase copper wound Automatic voltage stablizer of suitable capacity electronically controlled circuit with input voltage 140-260 volts single phase AC supply and output voltage 220 ± 5% volts single phase AC supply having main silicon core copper wound step up transformer with suitable nos. of turns on primary side and secondary side the transformer should be fully insulated inside the MS sheet box of suitable size. There should be power control relay and single pole MCB (C-curve, 10kA) of suitable capacity complete with internal copper wiring along with amp. meter and volt meter, high voltage cut off 280 volt input (240 volt output) and 90 volt maximum boost and overloading protection to be provided:-
Automatic Voltage Stablizer 5 KVA
Automatic Voltage Stablizer 10 KVA (For Tower AC)
Providing & fixing in position Commercial RO without reservoir with four no cartridge/ membrane having flow rate 50 ltr/hr with 6 stage purification process of approved make (to the approval of Engineer-in-charge ) including carriage and fixing in position complete in all respect.
Provision of RO for kitchen with 20 Litres/Hour, Capacity of tank 9 ltr, Storage capacity complete in all respect.
Providing and Fixing Kitchen Chimney / Hoods Make :- Faber (to the approval of Engineer-in-charge ) including carriage complete in all respect. Size 90 cm, Air Suction Capacity 1400 CMH
Providing and Fixing Oil filled heater 13 Fin Make :- Black & Decker (to the approval of Engineer-in-charge ) including carriage complete in all respect.
Providing and Fixing Refrigerator 650 ltr capacity frost free make: LG/ Samsung/ whirlpool (to the approval of Engineer-in-charge ) including carriage complete in all respect.
The Dashmesh Cooperative Labour and Construction Society Limited
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .