| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹1.3 LAccepted-Finance | ₹1.3 L | 1 | Accepted-Finance L1 |
| 2 | 2₹1.4 L+₹13,250 (10.3%)Accepted-Finance | ₹1.4 L+₹13,250 (10.3%) | 2 | Accepted-Finance L2 |
| Sl No | Description | Qty | Unit | Vinoth Electricals L1 | GAJENDRAA ELECTRIC COMPANY L2 |
|---|---|---|---|---|---|
| 1.00 | Transformer Oil filtration through hot stream Line process for 1 No. of 250 KVA Transformer up to the required value of 40KV for one minute including Transportation charges for filtering unit & oil testing kit.(250 KVA TR - 320 Ltrs & AVR - 300 Ltrs) | 620 | Ltrs | 18 ₹11,160 Lowest | 19 ₹11,780 |
| 2.00 | Testing of BDV and Acidity for transformer oil and issuing necessary test certificate. | 2 | Sets | 1,180 ₹2,360 Lowest | 1,200 ₹2,400 |
| 3.00 | Renewal by supply and fixing of new Transparent type Silicajel breather suitable for existing 250 KVA transformer with silicajel and oil cup. | 1 | Nos | 2,850 ₹2,850 Lowest | 3,000 ₹3,000 |
| 4.00 | Renewal by topping up of New transformer oil up to the required level for Transformer conservators and AVR | 90 | Ltrs | 225 ₹20,250 Lowest | 228 ₹20,520 |
| 5.00 | Charges for complete servicing of LT 440V 50Hz Air circuit breaker including thorough inspection of the ACB and carrying out the following maintenance nature of works for proper and efficient functioning of ACBs all as specified and as directed
Check, clean, align / tighten of the following:
a. All terminals and moving contacts,
b. All terminals UV/Shunt trip coil, check insulation resistance
c. All terminals of Breaker mounted release and current Tr.
d. All terminals of internal wiring circuits of complete panel
e. Cleaning Arc Chutes and checking LV Inc/OG connections
f. checking its mechanism alignment & draw-in arrangement
and apply petroleum jelly to all surfaces of contacts check insulation resistance and set for proper functioning. | 1 | Nos | 9,300 ₹9,300 Lowest | 9,900 ₹9,900 |
| 6.00 | Charges for testing of Earth Electrodes, Identification of Earth Pits and issuing necessary test reports | 10 | Nos | 480 ₹4,800 Lowest | 500 ₹5,000 |
| 7.00 | Towards the charges for servicing of 11 KV Air Break Gang Operated Switch for Easy operation by applying Petroleum Jelly in the Moving, Fixed Contacts and replacing the worn out parts. | 1 | Sets | 5,000 ₹5,000 Lowest | 5,500 ₹5,500 |
| 8.00 | Charges for complete checking of Main MV Panel Board, Distribution Panel boards for tightness of cable connections, bus-bar, incoming and Outgoing interconnecting flats, bus-bar interlinks etc., | 1 | Job | 3,500 ₹3,500 Lowest | 4,000 ₹4,000 |
| 9.00 | Servicing of APFC Panel, which includes the following:
• removing and cleaning all the accumulated dust, lubrication the contacts,
• checking the operation of all contactors, capacitors and tightening all the connections,
• checking for AUTO / MANUAL operation
• Checking the current transformer
• Checking Incoming cable connections etc.,
at site with necessary engineers and testing equipment’s | 1 | Nos | 9,000 ₹9,000 Lowest | 9,200 ₹9,200 |
| 10.00 | Renewal by supply and fixing of 230 V AC/DC LED Indication lamps | 20 | Nos | 250 ₹5,000 Lowest | 300 ₹6,000 |
Tender Value
Refer Docs
EMD Value
₹1,960
Closing Date
15 Sept 2026, 3:00 pmClosed
Executive Engineer electrical
Office of the Executive Engineer(Electrical), PWD, Electrical Division-II, Chepauk, Chennai-5
Electrical works Special repairs to 11 KV HT transformer and its allied works at Tamil Arasu Press at Taramani, Chennai-113.
2026_PWD_698465_1
09E2627
Open Tender
Electrical Works
Lump-sum
Tamilarasu Press in Taramani, Chennai-113.
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹1,960
16 Sept 2026
27 Aug 2026
15 Sept 2026
27 Aug 2026
15 Sept 2026
27 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Transformer Oil filtration through hot stream Line process for 1 No. of 250 KVA Transformer up to the required value of 40KV for one minute including Transportation charges for filtering unit & oil testing kit.(250 KVA TR - 320 Ltrs & AVR - 300 Ltrs) | - | Ltrs | - | - |
| 2 | Testing of BDV and Acidity for transformer oil and issuing necessary test certificate. | - | Sets | - | - |
| 3 | Renewal by supply and fixing of new Transparent type Silicajel breather suitable for existing 250 KVA transformer with silicajel and oil cup. | - | Nos | - | - |
| 4 | Renewal by topping up of New transformer oil up to the required level for Transformer conservators and AVR | - | Ltrs | - | - |
| 5 | Charges for complete servicing of LT 440V 50Hz Air circuit breaker including thorough inspection of the ACB and carrying out the following maintenance nature of works for proper and efficient functioning of ACBs all as specified and as directed
Check, clean, align / tighten of the following:
a. All terminals and moving contacts,
b. All terminals UV/Shunt trip coil, check insulation resistance
c. All terminals of Breaker mounted release and current Tr.
d. All terminals of internal wiring circuits of complete panel
e. Cleaning Arc Chutes and checking LV Inc/OG connections
f. checking its mechanism alignment & draw-in arrangement
and apply petroleum jelly to all surfaces of contacts check insulation resistance and set for proper functioning. | - | Nos | - | - |
| 6 | Charges for testing of Earth Electrodes, Identification of Earth Pits and issuing necessary test reports | - | Nos | - | - |
| 7 | Towards the charges for servicing of 11 KV Air Break Gang Operated Switch for Easy operation by applying Petroleum Jelly in the Moving, Fixed Contacts and replacing the worn out parts. | - | Sets | - | - |
| 8 | Charges for complete checking of Main MV Panel Board, Distribution Panel boards for tightness of cable connections, bus-bar, incoming and Outgoing interconnecting flats, bus-bar interlinks etc., | - | Job | - | - |
| 9 | Servicing of APFC Panel, which includes the following:
• removing and cleaning all the accumulated dust, lubrication the contacts,
• checking the operation of all contactors, capacitors and tightening all the connections,
• checking for AUTO / MANUAL operation
• Checking the current transformer
• Checking Incoming cable connections etc.,
at site with necessary engineers and testing equipment’s | - | Nos | - | - |
| 10 | Renewal by supply and fixing of 230 V AC/DC LED Indication lamps | - | Nos | - | - |
stage.html
html • 0.03 MB
tech_eval.pdf
fin_eval.pdf
finance_839571.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.03 MB
TenderDocument9.pdf
Tender Documents • 0.91 MB
BOQ_839571.xls
BOQ • 0.36 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .