Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹47.2 LAccepted-AOC TRICHY | ARIYALUR | TAMIL NADU | 608901 | ₹47.2 L | L1 | Accepted-AOC Being L1 |
| 2 | L2₹47.4 L+₹25,739 (0.55%)Rejected-Finance NO 1C C L C WORKS ROAD NEW COLONY CHROMEPET CHENNAI 600044 | CHENGALPATTU | TAMIL NADU | 600044 | ₹47.4 L+₹25,739 (0.55%) | L2 | Rejected-Finance Highly Quoted |
| 3 | L3₹48.0 L+₹80,729 (1.71%)Rejected-Finance D 60 BRINDAVAN NAGAR CIVIL AERODROME POST COIMBATORE 641014 | COIMBATORE | COIMBATORE | TAMIL NADU | 641014 | ₹48.0 L+₹80,729 (1.71%) | L3 | Rejected-Finance Highly Quoted |
| 4 | L4₹51.7 L+₹4.6 L (9.67%)Rejected-Finance | ₹51.7 L+₹4.6 L (9.67%) | L4 | Rejected-Finance Highly Quoted |
| 5 | L5₹54.3 L+₹7.1 L (15.1%)Rejected-Finance | ₹54.3 L+₹7.1 L (15.1%) | L5 | Rejected-Finance Highly Quoted |
Tender Value
₹63.1 L
EMD Value
₹1.3 L
Closing Date
13 Nov 2019, 5:00 pmClosed
Asst.Gen.Manager(E-E)
O/o Jt.Gen.Manager(E-E), Coimbatore International Airport.
Provision of GI sheet roofing including part office space over the old portion of the Departure Terminal Building at Coimbatore International Airport. SH. Electrical Works.
2019_AAI_35325_1
AAI/CBIA/ENGG(E)/GI SHEET/19-20
Open Tender
Electrical Works
Item Rate
270 days
Coimbatore International Airport
Please refer Tender documents.
13 documents required · 13 mandatory
₹1,120
Airports Authority of India
₹1.3 L
12 Feb 2020
6 Nov 2019
18 Nov 2019
7 Nov 2019
13 Nov 2019
7 Nov 2019
7 Nov 2019 - 12 Nov 2019
Amount
Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium conductor power cable conforming to IS 7098 (Part 1) amended upto date. 3.5 X 240 Sq.mm
Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium conductor power cable conforming to IS 7098 (Part 1) amended upto date. 3.5 X 150 Sq.mm
Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium conductor power cable conforming to IS 7098 (Part 1) amended upto date. 3.5 X 95 Sq.mm
Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium conductor power cable conforming to IS 7098 (Part 1) amended upto date. 3.5C 25 Sq.mm
Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium conductor power cable conforming to IS 7098 (Part 1) amended upto date. 4C 16 Sq.mm
Supplying and making indoor cable end termination with brass compression gland and aluminium lugs for following size of PVC insulated PVC sheathed/ XLPE aluminium conductor cable of 1.1 kV grade as required. 3.5C 240 Sq.mm
Supplying and making indoor cable end termination with brass compression gland and aluminium lugs for following size of PVC insulated PVC sheathed/ XLPE aluminium conductor cable of 1.1 kV grade as required. 3.5C 150 Sq.mm
Supplying and making indoor cable end termination with brass compression gland and aluminium lugs for following size of PVC insulated PVC sheathed/ XLPE aluminium conductor cable of 1.1 kV grade as required. 3.5C 95 Sq.mm
Supplying and making indoor cable end termination with brass compression gland and aluminium lugs for following size of PVC insulated PVC sheathed/ XLPE aluminium conductor cable of 1.1 kV grade as required. 3.5C 25 Sq.mm
Supplying and making indoor cable end termination with brass compression gland and aluminium lugs for following size of PVC insulated PVC sheathed/ XLPE aluminium conductor cable of 1.1 kV grade as required. 4 C 16 Sq.mm
Laying of one number XLPE/PVC insulated PVC sheathed aluminium/copper conductor power cable of 1.1 KV grade of following sizes in the existing RCC/ Hume/ Stoneware/ Metal pipe/trench as required. Upto 35 Sq.mm
Laying of one number XLPE/PVC insulated PVC sheathed aluminium/copper conductor power cable of 1.1 KV grade of following sizes in the existing RCC/ Hume/ Stoneware/ Metal pipe/trench as required. Above 35 Sq.mm upto 95 Sq.mm
Laying of one number XLPE/PVC insulated PVC sheathed aluminium/copper conductor power cable of 1.1 KV grade of following sizes in the existing RCC/ Hume/ Stoneware/ Metal pipe/trench as required. Above 95 Sq.mm upto 185 Sq.mm
Laying of one number XLPE/PVC insulated PVC sheathed aluminium/copper conductor power cable of 1.1 KV grade of following sizes in the existing RCC/ Hume/ Stoneware/ Metal pipe/trench as required. Above 185 Sq.mm upto 400 Sq.mm
Laying and fixing of one number XLPE/ PVC insulated PVC sheathed aluminium/copper conductor cable of 1.1 KV grade of following sizes on wall/ surface as required. Upto 35 Sq.mm
Laying and fixing of one number XLPE/ PVC insulated PVC sheathed aluminium/copper conductor cable of 1.1 KV grade of following sizes on wall/ surface as required. Above 35 Sq.mm upto 95 Sq.mm
Laying and fixing of one number XLPE/ PVC insulated PVC sheathed aluminium/copper conductor cable of 1.1 KV grade of following sizes on wall/ surface as required. Above 95 Sq.mm upto 185 Sq.mm
Laying and fixing of one number XLPE/ PVC insulated PVC sheathed aluminium/copper conductor cable of 1.1 KV grade of following sizes on wall/ surface as required. Above 185 Sq.mm upto 400 Sq.mm
Laying and fixing of one number XLPE/ PVC insulated PVC sheathed aluminium/copper conductor cable of 1.1 KV grade of following sizes on cable tray as required(With Caable tie). Upto 35 Sq.mm
Laying and fixing of one number XLPE/ PVC insulated PVC sheathed aluminium/copper conductor cable of 1.1 KV grade of following sizes on cable tray as required(With Caable tie). Above 35 Sq.mm upto 95 Sq.mm
Laying and fixing of one number XLPE/ PVC insulated PVC sheathed aluminium/copper conductor cable of 1.1 KV grade of following sizes on cable tray as required(With Caable tie). Above 95 Sq.mm upto 185 Sq.mm
Laying and fixing of one number XLPE/ PVC insulated PVC sheathed aluminium/copper conductor cable of 1.1 KV grade of following sizes on cable tray as required(With Caable tie). Above 185 Sq.mm upto 400 Sq.mm
Supplying and fixing of following sizes ISI marked PVC conduit along with all accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm
Supplying and fixing of following sizes ISI marked PVC conduit along with all accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm
Wiring for light point / fan point / exhaust fan point / call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface/recessed Medium class PVC conduit, with modular switch, modular plate,suitable GI box and earthing the point with 1.5sqmm FR PVC insulated copper conductor single core cable as required. (Group C)
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed/steel /PVC conduit as required 3 x 2.5 sq. mm
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed/steel /PVC conduit as required 4 x 2.5 sq. mm
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed/steel /PVC conduit as required 4 x 4 sq. mm
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed/steel /PVC conduit as required 4 C 16 Sq.mm
Supply of 4 (4+12) Way, double door vertical type TPN prewired load line sheet steel,MCB distribution board,415 volts with loose wire box,terminal blocks, duly prewired with suitable size FR PVC insulated copper conductor upto trerminal blocks,tinned copper busbar,neutral link,earth bar,din bar,detatchable gland plate,inter connections,phosphatized and powder painted, including eathing etc. as required ( incommer sutable for MCCB).
Supply of 6 way (4+18 IC/OG Pre Wired with cable end box) ,TPN harizontal , sheet steel, MCB distribution board, 240 volts, on surface/ recess,double door complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
Supply of 4 way (2+2, incomer MCB), IP 43-Metal Door , sheet steel, MCB distribution board, 240 volts, on surface/ recess,IP-43 glazed door complete (But without MCB/RCCB/Isolator)
Supply of 8 way (SP MCB), IP 43-Metal Door , sheet steel, MCB distribution board, 240 volts, on surface/ recess,IP-43 glazed door complete (But without MCB/RCCB/Isolator)
Supply of 63 A rating, four pole, 415 V MCB in the existing MCB DB complete etc. as required.
Supply of 32 A rating, four pole, 415 V MCB in the existing MCB DB complete etc. as required.
Supply of 25 A rating, four pole, 415 V MCB in the existing MCB DB complete etc. as required.
Supply of "B" Series SP MCB of rating 6-32 A suitable for operation at 415V 50 Hz AC
Supply of "C" Series SP MCB of following rating suitable for operation at 415V 50 Hz AC (a) 6 A -32 A
Fixing of 4 way (4+12 IC/OG Pre Wired with cable end box) ,TPN Vertical , sheet steel, MCB distribution board prewired sheet steel, MCB distribution board including testing,commissioning etc. as required
Fixing of 6 way (4+18 IC/OG Pre Wired with cable end box) ,TPN harizontal , sheet steel, MCB distribution board prewired sheet steel, MCB distribution board including testing,commissioning etc. as required
Fixing of 4 way (2+2, incomer MCB), IP 43-Glazed Door , sheet steel, MCB distribution board, 240 volts, on surface/ recess,IP-43 glazed door complete (But without MCB/RCCB/Isolator)
Fixing of 8 way (SP MCB), IP 43-Glazed Door , sheet steel, MCB distribution board, 240 volts, on surface/ recess,IP-43 glazed door complete (But without MCB/RCCB/Isolator)
Fixing of (63/40/32/25 A) rating 240 V, miniature circuit Breaker in the existing MCB DB complete with connections, testing,comissioning etc. as required.(a)three Pole/ four Ploe
Fixing of 5A to 32 A rating 240 V,"B"/"A" Series, miniature circuit Breaker in the existing MCB DB complete with connections, testing,comissioning etc. as required.(a)Single Pole/ Double Ploe
Supply of ISI marked UPVC MAXI Trunking ( casing & caping ) including Cover of following sizes 25mm X 16mm
Supply of ISI marked UPVC MAXI Trunking ( casing & caping ) including Cover of following sizes 75 mm X 50mm
Supply of ISI marked UPVC MAXI Trunking ( casing & caping ) including Cover of following sizes 100 mm X 50mm
Supply of ISI marked UPVC MAXI Trunking ( casing & caping ) including Cover of following sizes 150 mm X 50mm
Supply of following PVC Modular boxes siuitable to 5/6 and 15/16 Amps socket/Switch etc as required 3 Module
Supply of following PVC Modular boxes siuitable to 5/6 and 15/16 Amps socket/Switch etc as required 4 Module
Supply of following PVC Modular boxes siuitable to 5/6 and 15/16 Amps socket/Switch etc as required 6 Module
Supply of following PVC Modular boxes siuitable to 5/6 and 15/16 Amps socket/Switch etc as required 8 Module
Supply of following PVC Modular base with cover siuitable to 5/6 and 15/16 Amps socket/Switch etc as required 3 Module
Supply of following PVC Modular base with cover siuitable to 5/6 and 15/16 Amps socket/Switch etc as required 4 Module
Supply of following PVC Modular base with cover siuitable to 5/6 and 15/16 Amps socket/Switch etc as required 6 Module
Supply of following PVC Modular base with cover siuitable to 5/6 and 15/16 Amps socket/Switch etc as required 8 Module
Supply of following swich & Socket suitable to operate at 30 V, 50 Hz AC supply (Anchor/Havells/Legrand/MK) 15/16 amps, one way SP modular switch
Supply of following swich & Socket suitable to operate at 30 V, 50 Hz AC supply (Anchor/Havells/Legrand/MK) 6 pin 15/16 amps modulor socket
Supply of following swich & Socket suitable to operate at 30 V, 50 Hz AC supply (Anchor/Havells/Legrand/MK) 5/6 amps, one way SP modular switch
Supply of following swich & Socket suitable to operate at 30 V, 50 Hz AC supply (Anchor/Havells/Legrand/MK) 3 pin 5/6 amps modular socket
Supply of 36W recessed mounted LED 2X2 luminaire (full glow) with CRCA steel sheet housing with opal acrylic diffuser fixed in separate CRCA steel sheet frame with (including frame) operating voltage range (220-240V AC). LED driver with colour temperature 6000K range. LED having 50,000 burning hours and with THD less than 10%. complete with all necessary accessories as required (Panosonic CAT Ref. PBLM03404 or Halonix CAT REF. HLFPU22-02-36-CW. or having superior specification equivalent or As per tecnical Specification .)
Installation, testing and commissioning of prewired flourescent fitting / CFL/LED light fitting of all types complete with all accessories, lamps etc. directly on ceiling / wall, existing MS structure including connection with 1.5 sq.mm PVC insulated FRLS copper conductor single core cable and earthing etc. as required.
Installation, testing and commissioning of prewired flourescent fitting & CFL/LED light fitting of all types complete with all accessories, lamps etc. on false ceiling with mounting chain, anchor bolt, hooks etc including connection with 1.5 sq.mm PVC insulated FRLS copper conductor single core cable in flexible MS conduit and earthing etc. as required.
Supply of 12" inch 300 mm sweep industrial exhaust fan suitable for operation 230 V, 50 Hz Ac supply as required.
Supply of 15" inch industrial exhaust fan suitable for operation 230 V, 50 Hz Ac supply as required.
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
Providing and fixing 25 mm X 5 mm G.l. strip on surface or in recess for connections etc. as required.
Earthing with 38 mm dia, 3 mtr length copper pipe including excavation using 150 mm dia Augur or by manually digging a pit of size 600x600 mm at a depth of 3 mtr. Refilling with chemical powder (moisture enchancer) of 50 kgs i/c providing masonary enclosure with cover plate having locking arrangement etc complete as required.
Supply of Stainless Steel Hi-Speed Hand Dryer complete as required suitable for operation on 230 V, 50 Hz AC supply ect as required
Fixing of Hand Dryers complete with all accessories, etc. on wall with direct clipping including connection with 1.5 sq.mm PVC insulated FRLS copper conductor single core cable and earthing etc. as required.
Supplying and installing following size of Pre Fabricated Hot-Dip Galvanised cable trays with perforation in convenient sections, joined with connectors, suspended/Floor Support with GI suspenders/Support including bolts & nuts etc as required. 100 mm width X 50 mm depth X 1.6 mm thickness
Supplying and installing following size of Pre Fabricated Hot-Dip Galvanised cable trays with perforation in convenient sections, joined with connectors, suspended/Floor Support with GI suspenders/Support including bolts & nuts etc as required. 150 mm width X 50 mm depth X 1.6 mm thickness
Supplying and installing following size of Pre Fabricated Hot-Dip Galvanised cable trays with perforation in convenient sections, joined with connectors, suspended/Floor Support with GI suspenders/Support including bolts & nuts etc as required. 300 mm width X 50 mm depth X 1.6 mm thickness
Supply of 3C 2.5Sq.mm PVC insulated & FRPVC round sheathed Copper conductor (Flexible) Induastrial cable, 1.1 KV grade conforming to IS 694 etc as required (100 mtr each coil)
Supply of 3C 1.5Sq.mm PVC insulated & FRPVC round sheathed Copper conductor (Flexible) Induastrial cable, 1.1 KV grade conforming to IS 694 etc as required (100 mtr each coil)
Outdoor cable jointing kit with cast resin compound with lugs for 4 X 240 sq. mm 1.1 KV grade cable.
Outdoor cable jointing kit with cast resin compound with lugs for 4 X 150 sq. mm 1.1 KV grade cable.
Outdoor cable jointing kit with cast resin compound with lugs for 4 X 95 sq. mm 1.1 KV grade cable.
Outdoor cable jointing kit with cast resin compound with lugs for 4 X 25 sq. mm 1.1 KV grade cable
Supply of 3 star rated, 2 TR capacity Hi-wall split type Air conditioner consisting of 1 No. indoor unit (fan coil) with cordless LCD/LED remote and one number outdoor condensing unit comprising with sealed rotary/scroll compressor , suitable for operation on single phase, 230 volt, 50 Hz, AC supply, providing copper refrigerant pipes, copper cable, PVC drain pipe between room unit and condensing unit up to the length of 3 meters including first charge of refrigerant (R32/R410), and mounting stand/bracket for outdoor unit complete inline with tender documents as required.
ITC of 2.0 Ton Air-Conditioning unit including civil work such as driiling for hole, painting, finishing with the same and interconnection of pipelines/refrigerant lines and control cables comprising of the following including first charge of refrigerant etc., complete as required.
Supply of extra copper pipe line suitable for 1.5/2.0/3.0 TR AC units including providing insulation control cable etc. as required. 3/8" & 5/8" copper pipe line
Supply of 5KVA Voltage stabilizer wall mounting type suitable for 1.5/2.0 ton split A/C units suitable for operation on 230V, 50Hz. AC supply capable of performing with working voltage range 170 Volt to 270 Volt.
Supplying and fixing DP sheet steel enclosure on surface/recess along with 25/32 A 240 V "C" curve DP MCB complete with connections, testing and commissioning etc. as required
Dismantling and re-installation of following type split type AC units up to 3 mtrs refrigerant piping including mounting of indoor and out door units, drain piping arrangements, charging of refrigerant gas, insulation of refrigerant piping with extended polythylene / PVC piping etc. complete as required (1.5 Ton/ 2 Ton Split AC Units)
Supply, laying/fixing, termination etc. of following size insulated FRLS armoured copper cable in surface/ recess / above false ceiling /concealed space/wall concealed, etc. for control cabling of Fire detection and alarm devices and interconnecting them by 2 x 1.5 sq mm etc complete in all respects as required by the standard specifications.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/recessed conduit/submain wiring /cable as required.
LAKSHMI ELECTRICAL ENTERPRISES
C P MONCHESTER ELECTRICALS
Manoprabha Electricals
KALKI ELECTRICALS
Shantha ELectricals and Engineers Pvt Ltd
CHENNAI ENGINEERING SERVICES
DElite System Engineering (India) Pvt. Ltd.
stage.html
html • 0.06 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .