Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.4 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹26.3 L+₹2.7 L (11.3%)Rejected-AOC CHANDIGARH | CHANDIGARH | CHANDIGARH | 160001 | L2 | Rejected-AOC Rejected | |
| 3 | L3₹28.0 L+₹4.4 L (18.4%)Rejected-AOC BUILDING NO FLAT NO 19 6TH CROSS ROAD SANJEEVINI NAGAR MUDALAPALYA BANGALORE 560072 | BANGALORE | BANGALORE | KARNATAKA | 560072 | L3 | Rejected-AOC Rejected | |
| 4 | L4₹28.8 L+₹5.2 L (22.0%)Rejected-AOC 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | L4 | Rejected-AOC Rejected | |
| 5 | L5₹29.6 L+₹6.0 L (25.3%)Rejected-AOC | L5 | Rejected-AOC Rejected |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
14 Feb 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GARRISON ENGINEER
GE (U) Chandimandir PIN-134107
GE(U)/CHM-36/2023-24 REPAIR/ REPLACEMENT OF LT DISTRIBUTION SYSTEM AND CONNECTED ITEMS OF WORK AT VARIOUS E/M INSTALLATION UNDER GE (U) CHANDIMANDIR
2024_MES_637593_1
GE(U)/CHM-36/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
Chandimandir
Please refer Tender documents.
5 documents required · 5 mandatory
₹500
GE (U) Chandimandir
₹80,000
Yes
2 Apr 2024
16 Jan 2024
19 Feb 2024
16 Jan 2024
14 Feb 2024
31 Jan 2024
Amount
Excavation in trenches for foundations, laying / taking out of cables, erecting of poles etc, in any type of soil, not exceeding 1.5 mtr in depth and not exceeding 1.5 mtr in width and getting out, complete all as specified and as directed.
Excavating in post holes (or similar holes) each not exceeding 0.5 cum, getting out, returning, filling in and ramming earth, in layers not exceeding 25cm, watering, and removing surplus spoil to a distance not exceeding 50m and making good surface all as specified and directed by Engineer - in - Charge.
Surface excavation not exceeding 30cm deep and averaging 15cm deep and getting out in hard / dense soil all as specified and directed by Engineer - in – Charge.
Returning, filling in soils, in trenches including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and as directed.
Removing excavated soils to a distance exceeding 50 metres and not exceeding 100 metre and depositing where directed at a level not exceeding 1.50 metre above the starting point.
Surface dressing not exceeding 15cm deep including cleaning away all grass vegetation, sapling, shrubs, brushwood, undergrowth, roots and removing rubbish upto a distance of 50 Metres outside the periphery of the area complete all as specified and directed by Engineer - in - Charge.
M & L Sand filling under floors or in foundations including watering and consolidation all as specified and directed by Engineer - in - Charge.
Supply and lay in trenches, un-reinforced precast concrete cable cover, Class LV, Type-I, flat, size 250 mm x 150mm x 40mm for cable protection in trenches complete all as specified and directed by Engineer-in-Charge.
Supply and laying 50mm outer dia, double walled, corrugated HDPE duct pipe conforming to IS- 14930 Pt-II with antirodent and non flame propogating properties of approved colour complete with fittings for cable protection complete all as specified and as directed.
M&L Cement concrete 1:2:4 type B-1 using 20mm graded crushed stone aggregate for foundations, mass and for repairing to paths/ road & hardstanding etc. including necessary cutting of roads/ paths for passing of pipes and making good the disturbed portion complete all as specified and directed by Engineer – in - Charge.
M&L for Hardcore of gauge n exc. 63 mm of broken stone, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface around outdoor transformer and HT 11 KV two/four pole structure complete all as specified and directed.
M&L Brick work with sub class 'B' old size burnt bricks, straight or curved on plan exceeding 6 mtr mean radius built in CM 1:6 all as specified and directed by Engineer - in - Charge .
M & L rendering 10mm thick on fair faces of brick work or concrete surfaces in CM 1:6 finished even & smooth without using extra cement all as specified and directed by Engineer - in - Charge .
M&L as in replacement of Power Cables, Aluminium Stranded Conductor 300 sqmm, 3.5 core, XLPE Insulated, Cores laid up, PVC Inner sheathed, Armoured with galvanized wire or galvanized steel strip, overall PVC Sheathed, 1100V Grade as per IS 7098 (Part 1) complete laid in trenches / floors / ducts/ fixed to poles / walls / drawn through pipes etc including provn of lugs, glands, nuts, bolts & washers etc for connecting in LT feeder pillar box / transformer bushings/LT OH Line and testing on completion including taking down old unserviceable cable complete all as specified and directed by Engineer-in-Charge.
M&L as in replacement of Power Cables, Aluminium Stranded Conductor 240 sqmm, 3.5 core, XLPE Insulated, Cores laid up, PVC Inner sheathed, Armoured with galvanized wire or galvanized steel strip, overall PVC Sheathed, 1100V Grade as per IS 7098 (Part 1) complete laid in trenches / floors / ducts/ fixed to poles / walls / drawn through pipes etc including provn of lugs, glands, nuts, bolts & washers etc for connecting in LT feeder pillar box / transformer bushings/LT OH Line and testing on completion including taking down old unserviceable cable complete all as specified and directed by Engineer-in-Charge.
M&L as in replacement of Power Cables, Aluminium Stranded Conductor 185 sqmm, 3.5 core, XLPE Insulated, Cores laid up, PVC Inner sheathed, Armoured with galvanized wire or galvanized steel strip, overall PVC Sheathed, 1100V Grade as per IS 7098 (Part 1) complete laid in trenches / floors / ducts/ fixed to poles / walls / drawn through pipes etc including provn of lugs, glands, nuts, bolts & washers etc for connecting in LT feeder pillar box / transformer bushings/LT OH Line and testing on completion including taking down old unserviceable cable complete all as specified and directed by Engineer-in-Charge.
M&L as in replacement of Power Cables, Aluminium Stranded Conductor 150 sqmm, 3.5 core, XLPE Insulated, Cores laid up, PVC Inner sheathed, Armoured with galvanized wire or galvanized steel strip, overall PVC Sheathed, 1100V Grade as per IS 7098 (Part 1) complete laid in trenches / floors / ducts/ fixed to poles / walls / drawn through pipes etc including provn of lugs, glands, nuts, bolts & washers etc for connecting in LT feeder pillar box / transformer bushings/LT OH Line and testing on completion including taking down old unserviceable cable complete all as specified and directed by Engineer-in-Charge.
M&L as in replacement of Power Cables, Aluminium Stranded Conductor 120 sqmm, 3.5 core, XLPE Insulated, Cores laid up, PVC Inner sheathed, Armoured with galvanized wire or galvanized steel strip, overall PVC Sheathed, 1100V Grade as per IS 7098 (Part 1) complete laid in trenches / floors / ducts/ fixed to poles / walls / drawn through pipes etc including provn of lugs, glands, nuts, bolts & washers etc for connecting in LT feeder pillar box / transformer bushings/LT OH Line and testing on completion including taking down old unserviceable cable complete all as specified and directed by Engineer-in-Charge.
M&L as in replacement of Power Cables, Aluminium Stranded Conductor 95 sqmm, 3.5 core, XLPE Insulated, Cores laid up, PVC Inner sheathed, Armoured with galvanized wire or galvanized steel strip, overall PVC Sheathed, 1100V Grade as per IS 7098 (Part 1) complete laid in trenches / floors / ducts/ fixed to poles / walls / drawn through pipes etc including provn of lugs, glands, nuts, bolts & washers etc for connecting in LT feeder pillar box / transformer bushings/LT OH Line and testing on completion including taking down old unserviceable cable complete all as specified and directed by Engineer-in-Charge.
M&L as in replacement of Power Cables, Aluminium Stranded Conductor 70 sqmm, 3.5 core, XLPE Insulated, Cores laid up, PVC Inner sheathed, Armoured with galvanized wire or galvanized steel strip, overall PVC Sheathed, 1100V Grade as per IS 7098 (Part 1) complete laid in trenches / floors / ducts/ fixed to poles / walls / drawn through pipes etc including provn of lugs, glands, nuts, bolts & washers etc for connecting in LT feeder pillar box / transformer bushings/LT OH Line and testing on completion including taking down old unserviceable cable complete all as specified and directed by Engineer-in-Charge.
M&L as in replacement of Power Cables, Aluminium Stranded Conductor 50 sqmm, 3.5 core, XLPE Insulated, Cores laid up, PVC Inner sheathed, Armoured with galvanized wire or galvanized steel strip, overall PVC Sheathed, 1100V Grade as per IS 7098 (Part 1) complete laid in trenches / floors / ducts/ fixed to poles / walls / drawn through pipes etc including provn of lugs, glands, nuts, bolts & washers etc for connecting in LT feeder pillar box / transformer bushings/LT OH Line and testing on completion including taking down old unserviceable cable complete all as specified and directed by Engineer-in-Charge.
M&L as in replacement of Power Cables, Aluminium Stranded Conductor 35 sqmm, 3.5 core, XLPE Insulated, Cores laid up, PVC Inner sheathed, Armoured with galvanized wire or galvanized steel strip, overall PVC Sheathed, 1100V Grade as per IS 7098 (Part 1) complete laid in trenches / floors / ducts/ fixed to poles / walls / drawn through pipes etc including provn of lugs, glands, nuts, bolts & washers etc for connecting in LT feeder pillar box / transformer bushings/LT OH Line and testing on completion including taking down old unserviceable cable complete all as specified and directed by Engineer-in-Charge.
M&L as in replacement of Power Cables, Aluminium Stranded Conductor 25 sqmm, 4 core, XLPE Insulated, Cores laid up, PVC Inner sheathed, Armoured with galvanized wire or galvanized steel strip, overall PVC Sheathed, 1100V Grade as per IS 7098 (Part 1) complete laid in trenches / floors / ducts/ fixed to poles / walls / drawn through pipes etc including provn of lugs, glands, nuts, bolts & washers etc for connecting in LT feeder pillar box / transformer bushings/LT OH Line and testing on completion including taking down old unserviceable cable complete all as specified and directed by Engineer-in-Charge.
M&L as in replacement of Power Cables, Aluminium Stranded Conductor 16 sqmm, 4 core, XLPE Insulated, Cores laid up, PVC Inner sheathed, Armoured with galvanized wire or galvanized steel strip, overall PVC Sheathed, 1100V Grade as per IS 7098 (Part 1) complete laid in trenches / floors / ducts/ fixed to poles / walls / drawn through pipes etc including provn of lugs, glands, nuts, bolts & washers etc for connecting in LT feeder pillar box / transformer bushings/LT OH Line and testing on completion including taking down old unserviceable cable complete all as specified and directed by Engineer-in-Charge. Note for item 14 to 24 above: (i) Excavation, earth work and provision of cable covers / protection pipe etc shall be measured and paid separately under relevant items of BOQ.
Supply and laying as in replacement 50 mm bore tube "light grade" galvanised iron pipe laid in trenches or fixed along poles with mild steel clamps or protection to GI earth strip/cable, complete all as specified and directed by Engr-in- Charge.
Supply and laying as in replacement 80 mm bore tube "light grade" galvanised iron pipe laid in trenches or fixed along poles with mild steel clamps or protection to GI earth strip/cable, complete all as specified and directed by Engr-in- Charge.
Supply and laying as in replacement 100 mm bore tube "light grade" galvanised iron pipe laid in trenches or fixed along poles with mild steel clamps or protection to GI earth strip/cable, complete all as specified and directed by Engr-in- Charge.
M&L for earthing complete with galvanized iron earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level connecting to GI strip 32x6 mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanized iron or steel and earth wire protected by 50mm dia GI pipe medium grade and connected to pole structure/ panel board/earthing test point all as shown in electrical plate No. 3 of SSR Part-I(2009) and testing on completion complete all as specified and directed. Note :- The unit rate quoted shall also include for excavation, earth work in any type of soil, plain cement concrete 1:3:6 mix, Type C1 pit, 40mm thick RCC 1:2:4 mix type B1 cover reinforced with 8mm dia TMT bras @ 150mm C/C both ways, GI funnel with watering pipe, wire mesh, protection pipe, earth strip up to 7.50m long complete in addition to item No. 1(a) to (e) of preamble (Notes) under sub heading earthing, specified in SSR Part II.
M&L for earthing complete with copper earth plate electrode 600mm x 600mm x 3.15 mm thick buried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level connecting to copper strip 20x3 mm as earthing lead by means of bolts, nuts, check nuts and washers of copper and earth wire protected by 50mm dia GI pipe medium grade and connected to pole structure/ panel board/earthing test point all as shown in electrical plate No. 3 of SSR Part-I(2009) and testing on completion complete all as specified and directed. Note :- The unit rate quoted shall also include for excavation, earth work in any type of soil, plain cement concrete 1:3:6 mix, Type C1 pit, 40mm thick RCC 1:2:4 mix type B1 cover reinforced with 8mm dia TMT bras @ 150mm C/C both ways, GI funnel with watering pipe, wire mesh, protection pipe, earth strip up to 7.50m long complete in addition to item No. 1(a) to (e) of preamble (Notes) under sub heading earthing, specified in SSR Part II.
S & F mild steel work as in posts, struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire etc, and necessary provision of notch including welding and cutting at bottom etc; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc and similar work conforming to Fe-290 Gde E-165 all as specified and directed by Engineer - in - Charge.
Supply only chain link MS galvanised fencing any size or type all as specified and directed by Engineer - in - Charge.
Fixing only of chain link fencing including line wire, any mesh size and type to any type of standard rails straining bolts etc including provision of binding wire all as specified and directed by Engineer - in - Charge.
M & L 10 mm mild steel round bars Fe-410-W(Gde. E-250) quality-A or Fe 290(Gde-E-165) for securing chain link fencing including forming necessary hook/ bend for tightening with fencing post and the like complete all as specified and shown on drg.
S&F in replacement of MCCB 630 A, 4 pole, 50 KA (Ics =100% Icu) with adjustable thermal & fixed magnetic setting with bus bar spreader links for connecting both incoming and outgoing cables with suitable connections with suitable size of glands etc complete including testing & commissioning all as specified and as directed by the Engineer-in-Charge.
S&F in replacement of MCCB 500 A ,4 pole ,50 KA (Ics =100% Icu) with adjustable thermal & fixed magnetic setting with bus bar spreader links for connecting both incoming and outgoing cables with suitable connections with suitable size of glands etc complete including testing & commissioning all as specified and as directed by the Engineer-in-Charge.
S&F in replacement of MCCB 400 A ,4 pole ,36 KA (Ics =100% Icu) with adjustable thermal & fixed magnetic setting with bus bar spreader links for connecting both incoming and outgoing cables with suitable connections with suitable size of glands etc complete including testing & commissioning all as specified and as directed by the Engineer-in-Charge.
S&F in replacement of MCCB 315/350 A ,4 pole ,36 KA (Ics =100% Icu) with adjustable thermal & fixed magnetic setting with bus bar spreader links for connecting both incoming and outgoing cables with suitable connections with suitable size of glands etc complete including testing & commissioning all as specified and as directed by the Engineer-in-Charge.
S&F in replacement of MCCB 250 A ,4 pole ,36 KA (Ics =100% Icu) with adjustable thermal & fixed magnetic setting with bus bar spreader links for connecting both incoming and outgoing cables with suitable connections with suitable size of glands etc complete including testing & commissioning all as specified and as directed by the Engineer-in-Charge.
S&F in replacement of MCCB 200 A ,4 pole ,36 KA (Ics =100% Icu) with adjustable thermal & fixed magnetic setting with bus bar spreader links for connecting both incoming and outgoing cables with suitable connections with suitable size of glands etc complete including testing & commissioning all as specified and as directed by the Engineer-in-Charge.
S&F in replacement of MCCB 160 A ,4 pole ,36 KA (Ics =100% Icu) with adjustable thermal & fixed magnetic setting with bus bar spreader links for connecting both incoming and outgoing cables with suitable connections with suitable size of glands etc complete including testing & commissioning all as specified and as directed by the Engineer-in-Charge.
S&F as in replacement change over switch ON LOAD type, 415 volt, 50 Hz, AC 4 pole in sheet steel enclosures, capacity 400 Amps rated current manually operated confirming to IS : 13947 or lates edition with hight thermal and dynamic strength to with stand short circuit current level of 80 KA rms complete all as specified and directed by Engr-in-Charge.
S&F as in replacement change over switch ON LOAD type, 415 volt, 50 Hz, AC 4 pole in sheet steel enclosures, capacity 630 Amps rated current manually operated confirming to IS : 13947 or lates edition with hight thermal and dynamic strength to with stand short circuit current level of 80 KA rms complete all as specified and directed by Engr-in-Charge.
M&L as in replacement for GI strip 32 x 6 mm for earthing complete all as specified and directed by Engr-in-Charge.
Supply and fix of Copper strip 20 x 3.15mm with saddles and fixing screws etc for roof conductors and down conductors above ground complete all as specified and as directed by Engr-in-Charge.
Taking down old unserviceable ACB any type and Supply, installation testing and commissioning new LT ACB of 800 Amps four pole mannual draw out with thermal magnetic release based, 415 Volts, 50 Hz suitable for existing location alongwith replacement of burnt aluminum bus bar with connected nut bolts and lugs with new aluminum bus bar /nut bolts/lugs complete all as specified and directed by Engr-in-charge
Taking down old unserviceable ACB any type and Supply, installation testing and commissioning new LT ACB of 1000 Amps four pole mannual draw out with thermal magnetic release based, 415 Volts, 50 Hz suitable for existing location alongwith replacement of burnt aluminum bus bar with connected nut bolts and lugs with new aluminum bus bar /nut bolts/lugs complete all as specified and directed by Engr-in-charge.
Taking down old unserviceable ACB any type and Supply, installation testing and commissioning new LT ACB of 1250 Amps four pole mannual draw out with thermal magnetic release based, 415 Volts, 50 Hz suitable for existing location alongwith replacement of burnt aluminum bus bar with connected nut bolts and lugs with new aluminum bus bar /nut bolts/lugs complete all as specified and directed by Engr-in-charge.
Design, Fabricate, supply, installation and testing in replacement of outdoor type cubical panel board bus bar box with MCCB suitable for 3 phase 4 wire, 50 Hz supply system factory fabricated made out of CRCA sheet steel of 3mm thick for outer shell and 2mm thick for inner shell with front openable door with locking arrangement complete with powder coat painting and suitable packing material for IP-54 degree of protection and including provision of 40mmx40mmx5mm angle iron base frame of suitable size for mounting the panel board at a height of 450mm above GL and grouted in PCC foundation. The size of panel board shall not be less than 500mm x 500mm x 300mm (outer dimensions) accommodating and provision of following switchgears complete and including taking down of old unserviceble panel:- (i) TPN Aluminium bus bar 300 Amps 4 strips provided with heat shrinkable coloured PVC sleeve insulation mounted on insulators suitable for connecting 2 or 3 outgoing cables including provision of suitable glands. (ii) MCCB, 200 A, 4 Pole, 36 KA (Ics=100%Icu), 415 V, 50 Hz, with adjustable thermal - magnetic release - 01 No.
Supply and fixing PVC wiring ducts Type S-3 in standard slots, non flammable, non corrosive and rust proof in grey colour, ISI marked of size 60mm x 40mm complete all as specified and as directed.
Supply and fixing PVC wiring ducts Type S-3 in standard slots, non flammable, non corrosive and rust proof in gray colour, ISI marked of size 100mm x 60mm complete all as specified and as directed .
Supply and fixing PVC wiring ducts Type S-3 in standard slots, non flammable, non corrosive and rust proof in gray colour, ISI marked of size 120mm x 80mm complete all as specified and as directed.
M&L for straight throught joints heat shrinkable for XLPE/PVC insulated and sheathed aluminum conductor under ground cable 1100 volts 3.5 core 400 sqmm to 500 sqmm and testing after jointing complete all as specified and directed.
M&L for straight throught joints heat shrinkable for XLPE/PVC insulated and sheathed aluminum conductor under ground cable 1100 volts 3.5 core 240 sqmm to 300 sqmm and testing after jointing complete all as specified and directed.
M&L for straight throught joints heat shrinkable for XLPE/PVC insulated and sheathed aluminum conductor under ground cable 1100 volts 3.5 core 150 sqmm to 185 sqmm and testing after jointing complete all as specified and directed.
M&L for straight throught joints heat shrinkable for XLPE/PVC insulated and sheathed aluminum conductor under ground cable 1100 volts 3.5 core 70 sqmm to 120 sqmm and testing after jointing complete all as specified and directed.
M&L for straight throught joints heat shrinkable for XLPE/PVC insulated and sheathed aluminum conductor under ground cable 1100 volts 3.5 core 25 sqmm to 50 sqmm and testing after jointing complete all as specified and directed.
Design, supplying, installing, testing and commissioning in replacement of 100 KVAR Automatic Power factor Corrector (APFC) Panel of approx. size of 1800 X1100 X500mm factory made, cubical compartmentalized for each stage, outdoor type, IP 54 degree Protection, dust, vermin and weather proof, made out of CRCA MS Sheet of 3.15mm thickness, front openable with locking arrangement, fixed on 50x50x6mm angle iron base frame and 4 legs structure having 40cm ground clearance, duly grouted in P:C:C (1:2:4) complete panel powder coated with seven tank process from inside and outside, duly prewired with suitable size FRLS PVC insulated multistranded copper conductor wire for capacitor stages, metering & control accessories, earthing straps for connecting earth strips, cable entry from bottom including taking down old unserviceable APFC Panel and comprising the following:-
(a) Bus Bar system- Aluminium bus bars of size 30X10mm for phases and 30 x 5mm for neutral duly provided with colour coded heat shrinkable PVC sleeves. (b) Incomer – MCCB 125 Amp, 4 pole, 36 KA, ICS= 100% ICU, with adjustable thermal magnetic setting alongwith spreader terminals and rotary handle -01 No. (c) MCB, TP 63 Amp, D Series, 415 volts-01 No (d) MCB, TP 40 Amp, D Series, 415 volts-02 Nos (e) MCB, TP 20 Amp, D Series, 415 Volts-01 No. (f) MPP Capacitor, resin filled, heavy duty type for 3 phase 440 Volts & 50 HZ system of 50 KVAR capacity-01 No (g) MPP Capacitor, resin filled, heavy duty type for 3 phase 440 volt & 50HZ system of 25 KVAR capacity-01No
Jai Maa Electrical Works
RAHUL ENTERPRISES
R D Bansal
Vasudeva Trading Co.
Raman Electric Trading Co
HARISH SALES CORPORATION
SABHYATA ELECTRICAL AND MECHANICAL
Bharat Enterprises
JAMDAGNI ENGG WORKS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .