| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.1 LAccepted-AOC GURU NANAK NAGAR GALI BHATIA DHARAMSHALA WALI SIRSA HARYANA PIN 125055 | SIRSA | HARYANA | 125055 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹15.7 L+₹2,961 (0.19%)Rejected-Finance | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹15.7 L+₹7,499 (0.48%)Rejected-Finance | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹17.6 L+₹1.9 L (12.4%)Rejected-Finance H NO 29 DEVILAL COLONY TCP 2 HISAR CANTT HARYANA | HISAR | HISAR | HARYANA | 125006 | L4 | Rejected-Finance Being L4 | |
| 5 | L5₹22.0 L+₹6.3 L (40.4%)Rejected-Finance RZ 18 260 WEST SAGARPUR NEAR MCD SCHOOL NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L5 | Rejected-Finance Being L5 |
| Sl No | Description | Qty | Unit | KUNAL ENTERPRISES L2 | M/s Devendera construction L4 | P S TRADERS L5 | FOUJI ELECTRIC WORKS L3 | BHATIA ENTERPRISES L1 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Dis-assembling carefully ceiling fans (any make) of 1200mm/14mm sweep, cutting & removing old copper winding wire and rewinding the same with new super enameled copper wire of suitable size / gauge and weight not less than 325 gms including providing insulation varnishing, oiling, greasing, replaceing bearing, flexible wire and gun metal shaft complete reassembling including testing complete.
Note :-
(i) Cost of bearings, shall be measured and paid in this item and nothing extra shall be paid extra on this account.
(ii) Working spaces if required will be provided to the contractor for carrying out necessary rewinding/repair with in AGE E/M store yard premises.
Contd/-................ | 2,500 | EACH JOB | 217 ₹5,42,500 | 220 ₹5,50,000 | 300 ₹7,50,000 | 185 ₹4,62,500 Lowest | 190 ₹4,75,000 |
| 1.10(iii) If winded fan found unserviceable within six month of rewinding, contractor will repair the same without any extra cost. (iv) Cost of Machining work in body of ceiling fan by taking out worn out bush, boring hole to accommodate ball bearings is included in this item and nothing shall be paid extra on this account. (v) Cost of carrying ceiling fan fan from site to the workshop and refixing of the same after repair is included in this item and all T&P and vehicle cost will be born by the contractor in this regard. (vi) Cost of taking down refixing of fan shall be included in this items and nothing will be paid extra on this account. (vii) Cost of shaft shall be paid under relevant item of sch. | ||||||||
| 2.00 | Dis-assembling of exhaust fan of size 250mm/300mm/350mm/450mm/600mm AC 230 Volts, 50 Hz 900/1400 RPM for repair, removing existing burnt winding wire, bearing/bushes, tapes, flexible wire, shaft, check nuts, frame and rewinding with super enameled copper windings wire of suitable size and weight not less than 450gms and replacement of bushes, bearings, tubes, papers, shafts, check nuts, bolts and washers, capacitors, twin core wire of copper conductor flexible cable, greasing, varnishing and reassembling including testing complete.
Note :-
(i) Cost of bearings/bushes, provided shall be measured and paid in this item and nothing extra shall be paid on this account.
(ii) Working spaces if required will be provided to the contractor for carrying out necessary rewinding/repair within AGE E/M store yard premises.
Contd/-............ | 100 | EACH JOB | 377 ₹37,700 | 310 ₹31,000 | 250 ₹25,000 Lowest | 275 ₹27,500 | 300 ₹30,000 |
| 2.10(iii) If winded exhaust fan found unserviceable within six month of rewinding, contractor will repair the same without any extra cost. (iv) Cost of Machining work in body of exhaust fan by taking out worn out bush, boring hole to accommodate ball bearings is included in this item and nothing shall be paid extra on this account. (v) Cost of carrying ceiling exhaust fan from site to the workshop and refixing of the same after repair is included in this item and all T&P and vehicle cost will be born by the contractor in this regard. (vi) Cost of taking down and refixing of fan shall be included in this items and nothing will be paid extra on this account. | ||||||||
| 3.00 | M&L for cutting holes in the wall for fixing exhaust fan of sweep upto 600mm and making good the distrubed surfaces all as per existing complete all as specified and directed. | 2 | EACH JOB | 277 ₹554 | 200 ₹400 | 180 ₹360 Lowest | 500 ₹1,000 | 500 ₹1,000 |
| 4.00 | Supply and fix capacitor 2.5 mfd to 3.15mfd dry type with PVC clamp of ceiling fan make of capacitor Epcos, / Usha, Supreme/ Havells Tebcon. | 2,600 | EACH | 20 ₹52,000 | 30 ₹78,000 | 28 ₹72,800 | 17 ₹44,200 Lowest | 25 ₹65,000 |
| 5.00 | All as per Ser item No 4.00 here-in-before but 4 mfd to 6mfd dry type of exhaust fan make of capacitor Epcos, / Usha, Supreme/ Havells, Tibcon . | 150 | EACH | 27 ₹4,050 | 40 ₹6,000 | 30 ₹4,500 | 20 ₹3,000 Lowest | 26 ₹3,900 |
| 6.00 | Preparation of old painted surfaces of the body, blades, down rod etc of ceiling fans of size 1200/1400mm sweep (any make) complete by rubbing with amery paper and filing in cavities with approved filler and applying one coat of primer spray painting with synthetic enamel paint (Glossy white/ pale cream) on the body, blades, down rods and writing office name (GE Hisar) MES /Fan no with black synthetic enamel paint complete all as specified & directed. | 600 | EACH | 47 ₹28,200 | 25 ₹15,000 | 20 ₹12,000 Lowest | 25 ₹15,000 | 200 ₹1,20,000 |
| 7.00 | Preparation of old painted surfaces of the body, blades, and louvers of exhaust fans of size 380/450mm / 600mm sweep (any make) complete by rubbing with amery paper and filing in cavities with approved filler and applying one coat of primer spray painting with synthetic enamel paint (black/brown) on the body, blades, down rods and writing office name (GE Hisar) MES /Exhaust no with black synthetic enamel paint complete all as specified & directed. | 100 | EACH | 47 ₹4,700 | 30 ₹3,000 | 20 ₹2,000 Lowest | 40 ₹4,000 | 30 ₹3,000 |
| 8.00 | Supply and fix in repair of rubber bush clamp complete with nut bolt, fork hook and spilt pin, washer suitable for existing ceiling fan 1200mm/1400mm sweep. | 900 | EACH | 12 ₹10,800 | 10 ₹9,000 | 15 ₹13,500 | 10 ₹9,000 | 7 ₹6,300 Lowest |
Tender Value
₹28 L
EMD Value
₹56,000
Closing Date
18 Oct 2025, 6:00 pmClosed
GE HISAR
GE HISAR
REPAIR / REWINDING OF CEILING FANS, EXHAUST FANS AND OTHER ITEMS IN OTM ACCN UNDER GE HISAR AT MIL STN HISAR
2025_MES_731316_1
GE(H)-44/2025-26
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
GE HISAR
AS PER NIT
6 documents required · 6 mandatory
₹500
GE HISAR
₹56,000
Yes
29 Nov 2025
18 Sept 2025
28 Oct 2025
18 Sept 2025
18 Oct 2025
3 Oct 2025
Amount
Dis-assembling carefully ceiling fans (any make) of 1200mm/14mm sweep, cutting & removing old copper winding wire and rewinding the same with new super enameled copper wire of suitable size / gauge and weight not less than 325 gms including providing insulation varnishing, oiling, greasing, replaceing bearing, flexible wire and gun metal shaft complete reassembling including testing complete. Note :- (i) Cost of bearings, shall be measured and paid in this item and nothing extra shall be paid extra on this account. (ii) Working spaces if required will be provided to the contractor for carrying out necessary rewinding/repair with in AGE E/M store yard premises. Contd/-................
(iii) If winded fan found unserviceable within six month of rewinding, contractor will repair the same without any extra cost. (iv) Cost of Machining work in body of ceiling fan by taking out worn out bush, boring hole to accommodate ball bearings is included in this item and nothing shall be paid extra on this account. (v) Cost of carrying ceiling fan fan from site to the workshop and refixing of the same after repair is included in this item and all T&P and vehicle cost will be born by the contractor in this regard. (vi) Cost of taking down refixing of fan shall be included in this items and nothing will be paid extra on this account. (vii) Cost of shaft shall be paid under relevant item of sch.
Dis-assembling of exhaust fan of size 250mm/300mm/350mm/450mm/600mm AC 230 Volts, 50 Hz 900/1400 RPM for repair, removing existing burnt winding wire, bearing/bushes, tapes, flexible wire, shaft, check nuts, frame and rewinding with super enameled copper windings wire of suitable size and weight not less than 450gms and replacement of bushes, bearings, tubes, papers, shafts, check nuts, bolts and washers, capacitors, twin core wire of copper conductor flexible cable, greasing, varnishing and reassembling including testing complete. Note :- (i) Cost of bearings/bushes, provided shall be measured and paid in this item and nothing extra shall be paid on this account. (ii) Working spaces if required will be provided to the contractor for carrying out necessary rewinding/repair within AGE E/M store yard premises. Contd/-............
(iii) If winded exhaust fan found unserviceable within six month of rewinding, contractor will repair the same without any extra cost. (iv) Cost of Machining work in body of exhaust fan by taking out worn out bush, boring hole to accommodate ball bearings is included in this item and nothing shall be paid extra on this account. (v) Cost of carrying ceiling exhaust fan from site to the workshop and refixing of the same after repair is included in this item and all T&P and vehicle cost will be born by the contractor in this regard. (vi) Cost of taking down and refixing of fan shall be included in this items and nothing will be paid extra on this account.
M&L for cutting holes in the wall for fixing exhaust fan of sweep upto 600mm and making good the distrubed surfaces all as per existing complete all as specified and directed.
Supply and fix capacitor 2.5 mfd to 3.15mfd dry type with PVC clamp of ceiling fan make of capacitor Epcos, / Usha, Supreme/ Havells Tebcon.
All as per Ser item No 4.00 here-in-before but 4 mfd to 6mfd dry type of exhaust fan make of capacitor Epcos, / Usha, Supreme/ Havells, Tibcon .
Preparation of old painted surfaces of the body, blades, down rod etc of ceiling fans of size 1200/1400mm sweep (any make) complete by rubbing with amery paper and filing in cavities with approved filler and applying one coat of primer spray painting with synthetic enamel paint (Glossy white/ pale cream) on the body, blades, down rods and writing office name (GE Hisar) MES /Fan no with black synthetic enamel paint complete all as specified & directed.
Preparation of old painted surfaces of the body, blades, and louvers of exhaust fans of size 380/450mm / 600mm sweep (any make) complete by rubbing with amery paper and filing in cavities with approved filler and applying one coat of primer spray painting with synthetic enamel paint (black/brown) on the body, blades, down rods and writing office name (GE Hisar) MES /Exhaust no with black synthetic enamel paint complete all as specified & directed.
Supply and fix in repair of rubber bush clamp complete with nut bolt, fork hook and spilt pin, washer suitable for existing ceiling fan 1200mm/1400mm sweep.
Supply and fix in replacement Ceiling fan stator 1200mm sweep with copper winding including thick steel bolt with double nuts and locking pins and high quality rubber bushing to reduce vibration complete all as specified and directed by Engg-in-charge.
Supply and fix in replacement rotor complete with copper winding suitable for 1200mm sweep ceiling fan all as specified and directed by Engg-in-charge
Supply & Fix fan body set upper and lower made of mild steel with two set of bearing duly painted suitable for 1200mm sweep fan and any make complete all as specified and directed by Engg-in-charge.
Supply & Fix PVC canopy set (upper & lower) for ceiling fans of any sweep and make and fixing in position complete.
Supply & Fix of fan blades with screw made of Iron for ceiling fan of sweep 1200mm/1400mm complete.
Supply & Fix MS heavy duty down rod of 15mm dia and 450mm length with necessary cutting / drilling holes and painting for ceiling fans complete all as specified and directed.
Supply & Fix Iron blades with screw of exhaust fan 250/300mm/600mm sweep of any make complete.
Supply & Fix exhaust fan frame including rubber bush and all accessories like 04x legs for holding of exhaust fan etc suitable for exhaust fan of any make complete.
S&F in replacement Wall mounting Fan 400 mm sweep, 230 volts, fixed on wall with suitable size nut, bolts and washers complete all as specified and directed. Make: Crompton/Havells/Bajaj
Supply & Fix shaft with spring for ceiling fan of 1200/1400mm sweep and fixing in position for smooth functioning of ceiling fan complete all as specified and directed.
Supply & Fix in replacement fan motor for exhaust fan motor with copper winding cap-70W and 1400RPM suitable for 300 sweep complete all as specified and directed.
Supply and fix in replacement of exhaust fan motor with copper winding , capacity - 350w and 1400RPM suitable for 450mm sweep and fixing in position for smooth functioning of exhaust fan complete all as specified and directed.
Supply and fix in replacement of exhaust fan motor with copper winding , capacity - 500w and 950RPM suitable for 600mm and fixing in position for smooth functioning of exhaust fan complete all as specified and directed.
S&F in replacement PVC air fresh air Fan 300 mm sweep, 230 volts, with louvers and frame complete fixed on wall with suitable size nut, bolts and washers and connection complete all as specified & directed.
Supply & Fixing in replacement ceiling Fan 1200mm sweep 210 cfm Decoreted type with down rod , canopy, rubber reel etc including provision of three single core 0.5 sqmm copper conductor flexible cable connected from ceiling rose to fan and suitable size MS bolts, nuts for fixing ceiling fan complete all as specified and directed.
Supply & Fixing in replacement PVC flexible 3 core copper cable conductor of size 1.5Sqmm from ceiling rose to fan including connection complete.-
Supply and fixing in replacement PVC clamp holder suitable for ceiling fan/exhaust fan capacitor of superior quality all as specified and directed
Supply and fix in repair Ceiling fan regulator electronic four step type of suitable wattage, 230V suitable for 1200/1400 mm ceiling fan etc complete all as specified and directed. Make : Genric/Schneider/L&T/Legrand/Havells
S&F fan cover plate suitable for fixing on fan hook in ceiling complete all as specified and directed by Engg-in-charge
S&F in replacement of louvers iron with shutters suitable for existing exhaust fan of size 350mm/450mm and shape round/ square as per site reqt complete all as specified and directed by Engg-in-charge
S&F in replacement of louvers iron with shutters suitable for existing exhaust fan of size 600mm and shape round/ square as per site reqt complete all as specified and directed by Engg-in-charge
S&F in replacement post top LED lantern of capacity 40 Watt complete, 230 V AC outdoor type with decorative post for 360 degree indirect light IP-65 protection , die cast alluminium bottom housing and spun alluminium top reflector with decorative clear acrylic diffuser impact and corrosion resistant complete with driver and LED lamp all as specified & as directed.
KUNAL ENTERPRISES (BID ID -3447438)
FOUJI ELECTRIC WORKS (BID ID -3448251)
M/s Devendera construction (BID ID -3448122)
P S TRADERS (BID ID -3448718)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.54 MB
TENDERDOCUMENTS.pdf
Tender Documents • 2.31 MB
BOQ_818791.xls
BOQ • 0.25 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .