| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹11.1 LAccepted-AOC | 1 | Accepted-AOC BEING LOWEST | |
| 2 | 2₹12.8 L+₹1.5 L (13.2%)Rejected-Finance | 2 | Rejected-Finance BEING NOT LOWEST | |
| 3 | 3₹12.9 L+₹1.6 L (14.1%)Rejected-Finance | 3 | Rejected-Finance BEING NOT LOWEST | |
| 4 | 4₹13.4 L+₹2.2 L (19.1%)Rejected-AOC | 4 | Rejected-AOC BEING NOT LOWEST | |
| 5 | 5₹21.6 L+₹10.3 L (91.2%)Rejected-AOC | 5 | Rejected-AOC BEING NOT LOWEST |
Tender Value
Refer Docs
EMD Value
₹32,000
Closing Date
10 Aug 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE (I) Fatehgarh
AGE (I) Fatehgarh Cantt
REPAIR/REPLACEMENT OF INTERNAL ELECTRICATION FITTING AND FIXTURE IN OTM ACCN OF RRC AND MH AT FATEHGARH
2021_MES_459214_1
AGE(I) /FAT/ET-18 OF 2021-2022
Open Tender
Miscellaneous Works
Item Rate
180 days
AGE (I) Fatehgarh
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
AGE (I) Fatehgarh
₹32,000
Yes
14 Sept 2021
13 Jul 2021
12 Aug 2021
13 Jul 2021
10 Aug 2021
28 Jul 2021
13 Jul 2021 - 27 Jul 2021
60 days
Amount
Taking down copper/aluminium point wiring of any discrapation and any position (light, fan, socket or power point) complete, including fixture and fittings such as switches,socket, ceiling rose,lamp holder,pendants, bracket and regulator etc and removing material from site including making good disturbed surface to match with the existing surface complete all as specified and directed.
Taking down Aluminium sub main wiring and making good disturbed surfaces to match with the existing surface roof/wall/floor complete all as specified and as directed.
M&L for point wiring light/fan/exhaust fan point controlled by one switch with 1100 volt grade PVC insulated and unsheathed 1.5 Sq mm (FRLS) multistranded copper conductor cable with continuous earth wire of 1.5 Sq mm (FRLS) multistranded copper conductor cable PVC insulated and unsheathed, drawn in & including concealed PVC rigid conduit of suitable size medium grade with fittings (ISI marked) sunken pressed steel galvanised terminal boxes with top cover ISI marked plastic laminated hylam sheet for housing/ fixing switches etc complete all as specified and directed for the following- Note- (i) The quoted rete is deemed to be included for the chases cutting. (ii) Cutting chases for concealed shall be made good using CM 1:4 and surface finished to match the existing surface & colour.
...ditto as above but for one 5 pin 5 Amp switch socket combination point on an independent board.....ditto....
...ditto as above but for one 5 pin 5 Amp socket point controlled by one switch on same board......ditto....
M&L for point wiring of light/fan/Holder/exhaust fan point controlled by one switch with 1100 volt grade PVC insulated and unsheathed 1.5 Sq mm (FRLS) multistranded copper conductor cable with continuous earth wire of 1.5 Sq mm (FRLS) multistranded copper conductor cable PVC insulated and unsheathed, drawn in & including surface PVC rigid conduit of suitable size medium grade with fittings (ISI marked) sunken pressed steel galvanised terminal boxes with top cover ISI marked plastic laminated hylam sheet for housing/ fixing switches etc complete all as specified and directed.
..ditto as above but for One 5 pin 5 Amp switch socket combination point on an independent board......ditto....
..ditto as above but for One 5 pin 5 Amp socket point controlled by one switch on same board......ditto....
M&L for point wiring of one 15 Amp 6 Pin switch combination independent with 2.5 sqmm FRLS unsheathed copper conductor single core multistranded copper conductor cable with continuous earth wire of 1.5 Sq mm (FRLS) multistranded copper conductor cable PVC insulated and unsheathed, drawn in & including concealed PVC rigid conduit of suitable size medium grade with fittings (ISI marked) sunken pressed steel galvanised terminal boxes with top cover ISI marked plastic laminated hylam sheet for housing/ fixing switches etc complete all as specified and directed for the following- Note- (i) The quoted rete is deemed to be included for the chases cutting. (ii) Cutting chases for concealed shall be made good using CM 1:4 and surface finished to match the existing surface & colour.
S&F switch piano flush type 5 Amp single pole one way complete all as specified and as directed.
Fixing only switch piano flush type 5 Amp single pole one way complete all as specified and as directed.
S&F switch socket combination 2 in 1 flush type 5 Amp 5 Pin complete all as specified and as directed.
Fixing only switch socket combination 2 in 1 flush type 5 Amp 5 Pin complete all as specified and as directed.
S&F switch socket combination 5 in 1, 15 Amp flush type complete all as specified and as directed.
Fixing only switch socket combination 5 in 1, 15 Amp flush type complete all as specified and as directed.
M & L lamp holder PVC/Polycarbonate type insulated body with back plate angle type for batten fittings incl LED lamp of 12W and colour temp 6500K suitable to fix in angle hoder complete all as specified & directed.
Supply and fix electronic fan regulator 5 stepped type complete all as specified and directed.
S&F ceiling rose PVC/Poly carbonate isolated body three terminal AC 230 volts complete all as specified and directed.
M&L for sub main wiring with two single core 6 Sqmm FRLS copper conductor PVC insulated and unsheathed cable including PVC conduit medium grade (appropriate size) concealed in wall for sub main connection including 6 Sqmm FRLS insulated multistranded unsheathed copper conductor used as a earth wire to common earth and connection to earth dolly all as specified. ( Note :- Two runs of 6 sqmm FRLS and one run of 6 sqmm FRLS copper conductor shall be measured as one unit length.)
Supply and fixing in replacement MCB distribution board SPN 240 Volt 12 way with 200 Amp rated bus bar having IP-43 protection and double metal door concealed in wall including connection with copper thimbles as required complete all as specified.
Supply and fixing in replacement MCB distribution board SPN 240 Volt 8 way with 200 Amp rated bus bar having IP-43 protection and double metal door concealed in wall including connection with copper thimbles as required complete all as specified.
Supply and fixing in replacement MCB distribution board SPN 240 Volt 4 way with 200 Amp rated bus bar having IP-43 protection and double metal door concealed in wall including connection with copper thimbles as required complete all as specified.
S&F in replacement of MCB SPN 40-63 Amp 240 volt 'C' curve complete all as specifed and directed.
S&F MCB in replacement of MCB SP 6 to 32 Amp 240 Volt 'C' curve 10 KA complete all as specified and directed.
S&F 20W LED extruded aluminium batten fitting integrated electronic driver suitable for surface complete. (Make :-philips Cat No BN 021C LED20S PSU CW GR S2 or equivalent to specified make)
S&F 10W LED extruded aluminium batten fitting suitable for surface complete all as specified and as directed. (Make :- Philips Cat No BN 021C LED10S-6500 PSU GR S1 or equivalent to specified make )
S&F building security LED light 14 watt with IP-65 including suitable size of GI bracket complete all as specified and directed. (Make: Philips Cat No BRP 042 LED 14 CW MR S1 PSU GR or or equivalent to specified make )
S&F in repair of suspended/surface mounted 30W LED luminaire 4'X1' with diffused optic incl hanging arrangement suitable size of chain/ steel conduit pipe of suitable length as suspended down rod and mounted bracket complete all as specified and directed. (Make :- Philips Cat No SM270C LED30S 6500 PSUWH or equivalent to specified make)
S&F in replacement of surface mounted LED 15W luminair complete all as specified and directed. (Make :- C&S Cat Part No- LTCRSLM15HP LEDRND/W or equivalent to specified make )
S&F in replacement LED 600x600 mm fully diffused recessed LED luminair with high transmitive diffuser 36/37W complete all as specified and directed. (Make :- Philips Cat Part No- RC380B LED36S-6500 G4 L60 W60 PSU OD or equivalent to specified make )
Supply and fixing in replacement of VTPN DB suitable for Mounting MCCB as Incomer of rating 100 Amp Vertical distribution board 4 way with suitable rated bus bar having IP-43 protection and double metal door concealed in wall including MCCB 100 Amp, 16KA, 4 Pole complete electrical connection with aluminium thimbles as required complete all as specified.
S&F in repair Busbar chamber in sheet metal enclosure 100 Amp, 8 way TPN 415 Volt of aluminium busbar drilled holes including cadmium coated nuts, bolts, washer etc fixed on wall complete all as specified and directed. (Make: Havells Cat No: IHBC010008 or equivalent to specified make )
S&F in replacement of Busbar chamber in sheet metal enclosure 200 Amp, 8 way TPN 415 Volt of aluminium busbar drilled holes including cadmium coated nuts, bolts, washer etc fixed on wall complete all as specified and directed. (Make: Havells Cat No: IHBC020008 or equivalent to specified make )
S&F in replacement metal clad plug & socket with metal plug top enclosure with a two pin and earth plug top and socket suitable for one single pole MCB 32 Amp complete all as specified and directed.
Disconnecting and taking down old existing UNSV tube light fitting of any description and in any postion down with point wiring including connection complete with all accessories and down rod all complete all as specified and directed.
M&L for earthing complete with galvanised steel earth plate electrode 600 x 600 x 6 mm thick, burried directly into the ground (earth pit not less than 2.25 mtr below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to GI earth wire 4 mm dia by means of bolts, nuts, check nuts, and washers of galvanised iron or steel all as shown iln electrical plate No - 3 connected to earthing test point all as specified or indicated including excavation and connected earth work, PCC chamber and cover, watering pipe, funnel wire mesh but without earth lead protection pipe and test on completion after dismantling unserviceable erthing (above GL only) complete all as directed incl dismantling of exsisting earthing. Note :- On testing after completion if desired earth resistence is not obtained, the earthing will be redone at no extra cost.
S B ENTERPRISES
M/S YASHCON CONSTRUCTIONS
M/S J.B.AND SONS
M/S JAI JAGDAMBEY TRADERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .