GE NW KARANJA
NAVAL STATION KARANJA, URAN, RAIGAD, MAHARASHTRA
REPAIR REPLACEMENT OF VENTILATORS DOORS WINDOWS AND STRENGTHENING OF COLUMN AND BEAMS OF BUILDING NO P 165 UNDER GE NW KARANJA
2026_MES_793223_1
8425/E8
Open Tender
Civil Works
Item Rate
150 days
GE NW KARANJA
Class D and above and category a (i)
8 documents required · 8 mandatory
₹500
Yes
GE NW KARANJA
₹91,080
Yes
10 Oct 2026
10 Oct 2026
2 Nov 2026
10 Oct 2026
31 Oct 2026
24 Oct 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Chipping , removing carefullly concrete work by low impact hammer ,breakar without damaging the structure & cleaning and disposal of debries out side the premises etc. complete as directed by Engr-in-Charge.
Note:- Hard concrete should not be removed by force. | 650 | Sqm | - | - |
| - | M&L for Clean existing reinforcement with wire/ rotary wire brush, making the surfaces free from loose material dirt etc. complete and applying two coats of alkaline rust converting primer FEOVERT of Krishna Conchem or Roff rust cleaner of Piddilite or Dr. Fixit Rust removal or ShaliRust of STP Ltd. on the rebars, including cleaning the reinforcement, wirebrushing to remove loose rust spalls, wash the rebars with clean water within 3 min and wipe it dry complete all as directed by Engr-in-Charge | 65 | Sqm | - | - |
| - | M&L for applying two coats of Epoxy based Zinc primer in a span of four hours over the treated rebars and allow to dry for six hours. The application shall be done by brush. Epoxy primer for steel of make / brand - Corroseal-ZR of Krishna Conchem or Dr. Fixit Epoxy zinc primer etc. complete all as directed by Engr-in-Charge | 65 | Sqm | - | - |
| - | M&L for cleaning all loose laitance on the concrete substrate and applying one coat of epoxy bonding agent on exposed concrete surface to ensure bond between old concrete & new concrete by brush application complete all as directed by Engr-in-Charge.
Make / brand Monobond SBR of Krishna Conchem or Dr. Fixit epoxy bonding agent or Shalicrete URP of STP Ltd. | 650 | Sqm | - | - |
| - | M&L for Building up the profile of structural members by using latex additives(MONOBOND) modified air cured mortar system (Polymer modified mortar) (1:5:15 = 1 monobond - 5 Cement - 15 sand) -in damaged areas in 30mm thickness including leveling profliling etc complete all as directed by Engr-in-Charge | 450 | Sqm | - | - |
| - | M&L for applying concrete protection coating on finished structural members exposed to atmosphere make or brand IPNET of Krishna Conchem or New Coat from Dr. Fixit complete all as directed by Engr-in-Charge | 650 | Sqm | - | - |
| - | M&L for Drilling and fixing Rohibb Teflon nozzles in RCC members, including drilling holes of 12mm dia, 50 to 100mm deep holes. Works shall be carried out as mentioned below and complete all as directed by Engr-in-Charge :-
(i) Cleaning of holes. Clean the holes by air blower prior to fixing nozzles. (ii) Fixing of nozzles. Insert 12mm dia. Rohibb Teflon nozzles in cleaned holes. External end of nozzles to be machine to receive outlet of grouting gun.Fix it inside the holes by applying thixotropic epoxy putty to ensure complete sealing. Cure the system for min.12 hrs. (iii) Cutting of nozzles. Cut the nozzles by chisel after completion of grouting without damaging structural elements. (iv) In case crack upto 2mm wide, fix the injection nozzels directly over the cracks, at intervals of 6 to 9 inches, using a drilling machine. Fix PVC/MS nozzels in these holes with fast-setting epoxy putty & let it dry for 2 to 3 days. Also, seal the crack between the ports with epoxy putty. (v) In case where the crack is wider than 2mm upto 4 to 5mm, drill holes at the sides of the crack in a staggered fashion, at intervals of 6 inches and affix them with epoxy putty as mentioned above. (vi) Also, seal the face of the crack with a liberal application of the epoxy putty. | 75 | Each | - | - |
| - | M&L for Injecting of site mixed cement slurry grout, mixed in specified proportion containing cement, sand water with addition of plasticizers (approved make) & migratory corrosion inhibitors, water cement ratio shall be varied between 0.5 to 1.0 for each hole, shrinkage compensating cement slurry mixed to a lump free fresh creamy consistency ,Mixing shall be done by mechanical mixer continuously stirring mechanically to keep cement particles in suspension. Injection of approved/specified grout by means of pump at a pressure of 3-5 Kg/cm2 etc complete till the grout mix flows out from the nozzle indicating complete filling of grout in the holes drilled etc. complete all as directed by Engr-in-Charge.
Make / brand of Epoxy grout - Dr. Fixit Epoxy injection or EPCO KP-HP-250 of M/s Krishna Conchem or Shaligrout EI of STP Ltd. | 75 | Each | - | - |
| - | M&L for Injecting low viscosity (3-5cps) high molecular weight monomer by pressure and using mechanized injector gun with accessories till nozzles refuses to accept the grout, Including,Mixing of materialas:Mixing of material components(part a&b) in the required quantities as per manufacturer's instruction by weigh batching.Grouting:Fill the grouting gun with concrete penetrating corrosion inhibitor EPCO-KP-100/Protectsil CIT or Ferogard 903. Maintain desired pressure in the gun by air compressor; maintain the pressureat exit(2 to 3kg/cm2) by monitoring pressure guage at exit.Grout the material through prefixed nozzles in the structural elements@ 100ml per nozzle. Repeat the process for all the nozzles. | 7.5 | Kg | - | - |
| - | M&L for mild TMT steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia orsecuring with clips etc. complete all as specified and directed by Engr-in-Charge.
Note:-Replacement of steel reinforcement with TMT bars of appropriate size where 30% of cross section is reduced including dismantling of rusted steel complete all as specified and directed. | 100 | Kg | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.59 MB
8425TenderDocs.pdf
Tender Documents • 1.10 MB
BOQ_889535.xls
BOQ • 1.34 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .